Plan Review Details - Permit 03121588
| Plan Review Stops For Permit 03121588 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-02-27 |
Time |
09:43 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-02-27 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-23 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-01-10 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2004-01-20 00:00:00 | 1.PRODUCT APPROVALS NOT LISTED ON THE | | | PRODUCT APPROVAL SITE. SUBMIT THE | | | FOLLOWING INFORMATION. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 2. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | 3.PROJECT VALUE TO LOW.RESUBMIT WITH | | | A CORRECT PROJECT VALUE. | | | ANY QUESTIONS CALL ME. | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-19 |
Time |
06:10 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-02-19 |
Time |
06:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
11:01 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-01-06 |
Time |
14:34 |
Sent To |
M |
|
| Notes |
| 2004-01-06 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE NOTE #2, WE ARE NOW | | | UNDER THE 2002 NEC. | | | | | | 2)NOTE: PLEASE SEE NOTE #17, MENTIONS | | | 210.12 REQUIREMENT. WE ARE NOW UNDER | | | THE 2002 NEC WHICH CHANGED 210.12. | | | PLEASE ADJUST. | | | | | | 3)NOTE: PLEASE VERIFY OCP SHOWN FOR | | | 5 KW AHU. SHOWN EXCEEDING MAX OCP. | | | | | | 4)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS. SPACING TO MEET 2',6',12' RULE. | | | | | | 5)NOTE: PLANS SHOWS, A NEW 60A J-BOX?? | | | PLEASE CLARIFY?? | | | | | | 6)NOTE: PLEASE NOTE, WATER HEATER IS | | | SHOWN BEING INSTALLED IN EXIST CLOSET, | | | PLEASE PROVIDE NOTE TO MEET 422.17 | | | | | | 7)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS | | | A 200A MAIN DISC AND A 200A MCB PANEL? | | | PLEASE SEE THAT THIS IS PERMNITTED BY | | | CODE , HOWEVER IT IS NOT REQ'D. IF SHOWN | | | , THEN IT WILL BE REQ'D TO BE INSTALLED. | | | SAME COMMENT FOR FOOTER STEEL AS PART | | | OF GE SYSTEM. EXISTING BLDG ARE NOT | | | REQ'D TO HAVE FOOTER STEEL , BUT IF | | | SHOWN, THEN FOOTER WILL BE REQD'. | | | | | | 8)NOTE: PLEASE ADJUST VALUE FOR SCOPE | | | OF WORK SHOWN AND APPLIED FOR. PER | | | 104.6.5 FBC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW, IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-12 |
Time |
11:01 |
Sent To |
E |
|
| Notes |
| 2004-02-12 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-29 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-29 |
Time |
09:06 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-23 |
Time |
14:04 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-02-23 |
Time |
13:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-19 |
Time |
06:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-01-09 |
Time |
07:40 |
Sent To |
P |
|
| Notes |
| 2004-01-09 00:00:00 | DENIED: | | | RETURN AIR JUMPER FROM THE BEDROOM AREAS | | | IS NOT SIZED IN ACCORDANCE WITH THE | | | REVISION TO THE 2001 FBC(M) 601.4 | | | EFFECTIVE JUNE 30,2003.SEE THE | | | ATTACHED SCHEDULE FOR PROPER SIZING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-09 |
Time |
07:59 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-01-10 |
Time |
11:32 |
Sent To |
B |
|
| Notes |
| 2004-01-10 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|
|