| Plan Review Stops For Permit 03121470 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-03-24 |
Time |
13:17 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2004-03-24 |
Time |
13:17 |
Sent To |
PC |
|
| Notes |
| 2004-03-24 00:00:00 | ENGINEER LETTER TO ADDRESS PROVISO ITEMS | | | . |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-03-01 |
Time |
10:52 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2004-03-01 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2004-03-01 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE FLORIDA/LOCAL PRODUCT APPROVAL | | | FOR ALL DOORS, WINDOWS, ROOF TILE, | | | WINDOW MULLIONS, GLASS BLOCK AND ALL | | | STRUCTURAL CONNECTORS PRIOR TO INSTA- | | | LLATION. | | | 2-GARAGE BUCK DETAIL E/4 AND RESIDENTIAL | | | NOTES ON SHEET #2 DON'T MATCH. CLARIFY | | | SPACING OF FASTENER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:20 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2004-01-23 |
Time |
17:45 |
Sent To |
PC |
|
| Notes |
| 2004-01-23 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-SOME DRAWINGS ARE MISSING INFORMATION | | | REQUIRED BY ARCHITECT TO BE INCLUDED | | | IN ALL PLANS. CHAPTER 481 FL STATUTES. | | | NAME OF ARCHITECT AND DATE OF SEALING. | | | 2-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC | | | PRODUCT APPROVAL FOR WINDOWS, DOORS, | | | GLASS BLOCK, ROOF TILE, MULLIONS AND | | | STRUCTURAL CONNECTORS. | | | 3-GARAGE BUCK DETAIL AND NOTES ON DWG #2 | | | DON'T MATCH. CHECK FASTENER SIZE. | | | 4-TRUSS ANCHOR SCHEDULE: PROVIDE CALCS | | | FOR TYPE/NUMBER OF FASTENERS OTHER | | | THAN THOSE TESTED AND PUBLISHED BY USP | | | TO COMPLY WITH SEC. 1609.4.3 FBC 2001. | | | 5-DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENERS. SEC. 104.2.1.1 CITY | | | AMENDMENTS TO FBC 2001 AND SECTION | | | 1606.3 FBC 2001. | | | 6-REVISE WINDOW BUCK DTAIL. SEE SECTION | | | 1707.4.4.2 FBC 2001 FOR PROPER BUCK | | | INSTALLATION. | | | 7-SHEET #3: A)REVISE/CLARIFY EXTERIOR | | | OPENING DESIGN PRESSURES ACCORDING TO | | | SIZE AND LOCATION. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | B)PROVIDE ENGINEERING CALCS FOR SYMPSON | | | EG7 CONNECTOR FASTENERS, SINCE THEY'RE | | | DIFFEENT THAN THOSE TESTED & PUBLISHED | | | TO COMPLY WITH SEC. 1609.4.3 FBC 2001. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-16 |
Time |
16:41 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-01-15 |
Time |
13:54 |
Sent To |
PC |
|
| Notes |
| 2004-01-15 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-ARCHITECT TO COMPLY WITH ALL REQUIRE- | | | MENTS OF CHAPTER 481 FLORIDA STATUTES | | | WHEN SUBMITTING DWGS FOR PUBLIC RECORD | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | | 3-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC | | | PRODUCT APPROVAL FOR: ALL DOORS/WINDOW | | | TYPE, GLASS BLOCK MULLIONS, ROOF TILE | | | AND STRUCTURAL CONNECTORS. | | | 4-PROVIDE SPECIFIC UL LISTING FOR ONE HR | | | FIRE RATED GLASS BLOCK ASSEMBLY AND | | | REVISE DETAIL TO MATCH AL COMPONENTS | | | ON SUCH ASSEMBLY. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 5-GARAGE BUCK DETAIL AND NOTES ON DWG #2 | | | DON'T MATCH. CHECK FASTENER SIZE. | | | 6-A)UPDATE TRUSS ANCHOR SCHEDULE AND ALL | | | DETAILS THAT ARE AFFECTED BY SECTION | | | 1609.4.3 FBC REGARDING STEEL STRESS. | | | NEED ENGINEERING CALCS FOR DIFFERENT | | | VALUES AND FASTENERS OTHER THAN THOSE | | | PUBLISHED ON REVISED CATALOGUES. | | | B)SPECIFY SIZE OF USP RT STRAPS. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 7-DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENERS. SEC. 104.2.1.1 CITY | | | AMENDMENTS TO FBC 2001. | | | 8-REVISE WINDOW BUCK DETAIL. SEE SEC. | | | 1707.4.4.2 FBC 2001 FOR PROPER BUCK | | | INSTALLATION. | | | 9-A)DESIGN PRESSURES FOR EXTERIOR OPG'S | | | DON'T MATCH TABLES 1606.2B & 1606.2E | | | FBC 2001 ACCORDING TO SIZE/LOCATION. | | | PROVIDE CALCULATIONS FOR PRESSURES | | | THAT AREN'T CLOSE TO ABOVE TABLES. SEC | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | B)PROVIDE CALCULATIONS TO SHOW SIMPSON | | | EG-7 CONNECTOR COMPLIANCE WITH SECTION | | | 1609.4.3 FBC 2001 SINCE FASTENERS ARE | | | DIFFERENT FROM THOSE ALREADY TESTED & | | | PUBLISHED BY SIMPSON. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-03 |
Time |
15:57 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-03-03 |
Time |
15:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-03-01 |
Time |
10:58 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-02 |
Time |
14:54 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
14:20 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO JG DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:19 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO JG DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:02 |
Sent To |
B |
|
| Notes |
| 2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-16 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-01-16 |
Time |
16:41 |
Sent To |
PC |
|
| Notes |
| 2004-01-16 00:00:00 | TO JG DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-15 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2003-12-24 |
Time |
10:26 |
Sent To |
PC |
|
| Notes |
| 2003-12-29 00:00:00 | 12/24/03TO Z | | | 12/29/03 TO E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-09 |
Time |
16:44 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-03-09 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | PROVISO: | | | PLAN SUBMITTED FOR RESTAMP IS NOT THE | | | SAME AS THE APPROVED SET OF PLANS.THE | | | RETURN AIR JUMPER FROM THE MASTER | | | BEDROOM & BEDROOM #3 ARE NOT SIZED | | | PROPERLY.THE RETURN FOR THE MASTER | | | BEDROOM SHALL BE A MINIMUM OF 14" & | | | BEDROOM #3 SHALL BE A MINIMUM OF 9". | | | | | | SUBMITTED A REVISED MECHANICAL PLAN | | | SHOWING PROPER SIZE FOR THE | | | AFOREMENTIONED ROOMS PRIOR TO FINAL | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-02 |
Time |
14:54 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-05 |
Time |
07:49 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-03 |
Time |
15:57 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-10 |
Time |
06:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-29 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-24 |
Time |
14:51 |
Sent To |
I |
|
| Notes |
|
|