Plan Review Details - Permit 03121470
Plan Review Stops For Permit 03121470
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-03-24 Cont ID  
Sent By jgomez Date 2004-03-24 Time 13:17 Rev Time 0.33
Received By jgomez Date 2004-03-24 Time 13:17 Sent To PC
Notes
2004-03-24 00:00:00ENGINEER LETTER TO ADDRESS PROVISO ITEMS
 .

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-01 Cont ID  
Sent By jgomez Date 2004-03-01 Time 10:52 Rev Time 0.50
Received By jgomez Date 2004-03-01 Time 10:51 Sent To E
Notes
2004-03-01 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE FLORIDA/LOCAL PRODUCT APPROVAL
 FOR ALL DOORS, WINDOWS, ROOF TILE,
 WINDOW MULLIONS, GLASS BLOCK AND ALL
 STRUCTURAL CONNECTORS PRIOR TO INSTA-
 LLATION.
 2-GARAGE BUCK DETAIL E/4 AND RESIDENTIAL
 NOTES ON SHEET #2 DON'T MATCH. CLARIFY
 SPACING OF FASTENER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-23 Cont ID  
Sent By csiegber Date 2004-02-27 Time 14:20 Rev Time 1.00
Received By jgomez Date 2004-01-23 Time 17:45 Sent To PC
Notes
2004-01-23 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-SOME DRAWINGS ARE MISSING INFORMATION
 REQUIRED BY ARCHITECT TO BE INCLUDED
 IN ALL PLANS. CHAPTER 481 FL STATUTES.
 NAME OF ARCHITECT AND DATE OF SEALING.
 2-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC
 PRODUCT APPROVAL FOR WINDOWS, DOORS,
 GLASS BLOCK, ROOF TILE, MULLIONS AND
 STRUCTURAL CONNECTORS.
 3-GARAGE BUCK DETAIL AND NOTES ON DWG #2
 DON'T MATCH. CHECK FASTENER SIZE.
 4-TRUSS ANCHOR SCHEDULE: PROVIDE CALCS
 FOR TYPE/NUMBER OF FASTENERS OTHER
 THAN THOSE TESTED AND PUBLISHED BY USP
 TO COMPLY WITH SEC. 1609.4.3 FBC 2001.
 5-DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENERS. SEC. 104.2.1.1 CITY
 AMENDMENTS TO FBC 2001 AND SECTION
 1606.3 FBC 2001.
 6-REVISE WINDOW BUCK DTAIL. SEE SECTION
 1707.4.4.2 FBC 2001 FOR PROPER BUCK
 INSTALLATION.
 7-SHEET #3: A)REVISE/CLARIFY EXTERIOR
 OPENING DESIGN PRESSURES ACCORDING TO
 SIZE AND LOCATION. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 B)PROVIDE ENGINEERING CALCS FOR SYMPSON
 EG7 CONNECTOR FASTENERS, SINCE THEY'RE
 DIFFEENT THAN THOSE TESTED & PUBLISHED
 TO COMPLY WITH SEC. 1609.4.3 FBC 2001.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-01-16 Time 16:41 Rev Time 2.00
Received By jgomez Date 2004-01-15 Time 13:54 Sent To PC
Notes
2004-01-15 00:00:00BUILDING REVIEW CHECKLIST:
 1-ARCHITECT TO COMPLY WITH ALL REQUIRE-
 MENTS OF CHAPTER 481 FLORIDA STATUTES
 WHEN SUBMITTING DWGS FOR PUBLIC RECORD
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC
 PRODUCT APPROVAL FOR: ALL DOORS/WINDOW
 TYPE, GLASS BLOCK MULLIONS, ROOF TILE
 AND STRUCTURAL CONNECTORS.
 4-PROVIDE SPECIFIC UL LISTING FOR ONE HR
 FIRE RATED GLASS BLOCK ASSEMBLY AND
 REVISE DETAIL TO MATCH AL COMPONENTS
 ON SUCH ASSEMBLY. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 5-GARAGE BUCK DETAIL AND NOTES ON DWG #2
 DON'T MATCH. CHECK FASTENER SIZE.
 6-A)UPDATE TRUSS ANCHOR SCHEDULE AND ALL
 DETAILS THAT ARE AFFECTED BY SECTION
 1609.4.3 FBC REGARDING STEEL STRESS.
 NEED ENGINEERING CALCS FOR DIFFERENT
 VALUES AND FASTENERS OTHER THAN THOSE
 PUBLISHED ON REVISED CATALOGUES.
 B)SPECIFY SIZE OF USP RT STRAPS. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 7-DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENERS. SEC. 104.2.1.1 CITY
 AMENDMENTS TO FBC 2001.
 8-REVISE WINDOW BUCK DETAIL. SEE SEC.
 1707.4.4.2 FBC 2001 FOR PROPER BUCK
 INSTALLATION.
 9-A)DESIGN PRESSURES FOR EXTERIOR OPG'S
 DON'T MATCH TABLES 1606.2B & 1606.2E
 FBC 2001 ACCORDING TO SIZE/LOCATION.
 PROVIDE CALCULATIONS FOR PRESSURES
 THAT AREN'T CLOSE TO ABOVE TABLES. SEC
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 B)PROVIDE CALCULATIONS TO SHOW SIMPSON
 EG-7 CONNECTOR COMPLIANCE WITH SECTION
 1609.4.3 FBC 2001 SINCE FASTENERS ARE
 DIFFERENT FROM THOSE ALREADY TESTED &
 PUBLISHED BY SIMPSON. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-03 Cont ID  
Sent By btrobaug Date 2004-03-03 Time 15:57 Rev Time 0.33
Received By btrobaug Date 2004-03-03 Time 15:40 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-02 Cont ID  
Sent By jgomez Date 2004-03-01 Time 10:58 Rev Time 0.33
Received By dpalmer Date 2004-01-02 Time 14:54 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 14:20 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 14:20 Sent To B
Notes
2004-02-27 00:00:00TO JG DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:19 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 12:19 Sent To B
Notes
2004-02-27 00:00:00TO JG DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-11 Cont ID  
Sent By csiegber Date 2004-02-11 Time 16:02 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 16:02 Sent To B
Notes
2004-02-11 00:00:00TO JG DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-23 Cont ID  
Sent By csiegber Date 2004-01-16 Time 16:41 Rev Time 0.00
Received By jgomez Date 2004-01-16 Time 16:41 Sent To PC
Notes
2004-01-16 00:00:00TO JG DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-15 Cont ID  
Sent By mmclean Date 2004-01-15 Time 14:16 Rev Time 0.00
Received By jgomez Date 2003-12-24 Time 10:26 Sent To PC
Notes
2003-12-29 00:00:0012/24/03TO Z
 12/29/03 TO E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-10 Cont ID  
Sent By pkrauss Date 2004-03-09 Time 16:44 Rev Time 0.25
Received By pkrauss Date 2004-03-09 Time 16:43 Sent To  
Notes
2004-03-09 00:00:00PROVISO:
 PLAN SUBMITTED FOR RESTAMP IS NOT THE
 SAME AS THE APPROVED SET OF PLANS.THE
 RETURN AIR JUMPER FROM THE MASTER
 BEDROOM & BEDROOM #3 ARE NOT SIZED
 PROPERLY.THE RETURN FOR THE MASTER
 BEDROOM SHALL BE A MINIMUM OF 14" &
 BEDROOM #3 SHALL BE A MINIMUM OF 9".
  
 SUBMITTED A REVISED MECHANICAL PLAN
 SHOWING PROPER SIZE FOR THE
 AFOREMENTIONED ROOMS PRIOR TO FINAL
 INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-05 Cont ID  
Sent By dpalmer Date 2004-01-02 Time 14:54 Rev Time 0.33
Received By pkrauss Date 2004-01-05 Time 07:49 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-10 Cont ID  
Sent By btrobaug Date 2004-03-03 Time 15:57 Rev Time 0.33
Received By kstevens Date 2004-01-10 Time 06:54 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-24 Cont ID  
Sent By csiegber Date 2003-12-29 Time 11:00 Rev Time 0.00
Received By mmclean Date 2003-12-24 Time 14:51 Sent To I
Notes
***NONE***