| Plan Review Stops For Permit 03121414 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-05 |
Time |
08:36 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-03-05 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-04 |
Time |
16:56 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2004-02-19 |
Time |
10:15 |
Sent To |
Z |
|
| Notes |
| 2004-02-19 00:00:00 | DENIED | | | WEST PALM BEACH AMMENDMENT TO THE FBC | | | 104.6.5BUILDING PERMIT VALUATION | | | TOTAL PERMIT FEES PAID ARE FOR $25,000 | | | NUMBERS 6,7,8,9 AND 10 ARE NOT INCLUDED | | | IN THE PERMIT VALUE. ADDITIONAL VALUE | | | OF $15,000 NEEDS TO BE APPLIED BEFORE A | | | PERMIT WILL BE ISSUED. | | | | | | FBC 3401.7.2.6WHEN REPAIRS AND | | | ALTERATIONS AMOUNTING TO MORE THAN 50% | | | OF THE VALUE OF THE EXISTING STRUCTURE | | | ARE MADE DURING ANY 12 MONTH PERIOD, | | | THE STRUCTURE SHALL BE MADE TO CONFORM | | | TO THE REQUIREMENTS FOR A NEW STRUCTURE. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-13 |
Time |
08:43 |
Rev Time |
1.75 |
| Received By |
alange |
Date |
2004-01-16 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | 1. DIFFERENT ENGINEERS USED FROM FIRST | | | PLAN TO REVISED PLAN.HAVE FIRST | | | ENGINNER SIGN OFF PROJECT TO NEW | | | ENGINEER. | | | 2.SHOW NEW STAIR FRAMING DETAIL. | | | 3.SHOW INTERIOR BEARING WALL FRAMING | | | DETAILS. | | | 4.SUBMIT PRODUCT APPROVALS FOR EXTERIOR | | | DOORS,WINDOWS, AND IMPACT PROTECTION. | | | 5. SLEEPING ROOMS SHALL COMPLY WITH SEC. | | | 1005.0 FBC EMERGENCY EGRESS | | | REQUIREMENTS. | | | 6.GLASS SHALL BE IN ACCORDANCE WITH | | | SECTION FBC 2405.2.1 HAZARDOUS | | | LOCATIONS. | | | 7.A E-1 CLEARANCE BETWEEN WOOD AND | | | GROUND FBC 2304.2.5MIN. 6" CLEARANCE | | | UNLESS PRESERVATIVE-TREATED WOOD IS | | | USED. | | | 8.SHOW INSULATION DETAILS. | | | 9.FBC. 104.6.5 BUILDING PERMIT VALUATI | | | ON TOO LOW. SEE ATTACHED CODE SECTION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-12-23 |
Time |
13:53 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2003-12-23 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | PROJECT VALUE TOO LOW.AFTER DISCUSSING | | | PROJECT WITH ROBERT BROWN AND BILL | | | TROBAUGH PROJECT VALUE WAS DECREASED TO | | | $5000 AFTER OUR RECOMMENDATIONS TO | | | INCREASE IT TO A FAIR VALUE. | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-03-18 |
Time |
13:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-03-18 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-04 |
Time |
13:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-04 |
Time |
12:39 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-03 |
Time |
09:37 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-02-09 |
Time |
11:41 |
Sent To |
P |
|
| Notes |
| 2004-02-09 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALL-ED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BERATED FOR THE AVAILABLE FAULT | | | CURRENT. | | | PER 110.9/215.5 | | | | | | 2} PLEASE SUBMIT PANEL SCHEDULES FOR ALL | | | PANELS SO THAT CODE COMPLIANCE OF | | | CIRCUITS CAN BE DETERMINED. | | | | | | 3} PLEASE SHOW PANEL "A" LOCATION ON | | | PLAN. | | | | | | 4} PLEASE SEE RECEPTS SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5.COUNTERTOP SPACING | | | IS INCORRECT. | | | | | | 5} THE BATHROOM OFF THE KITCHEN IS | | | REQUIRED TO HAVE A GFI RECEPTACLE PER | | | 210.52(D) & COMLPY WITH 210.11(C)(3). | | | | | | 6} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | | | | | | | 2)NOTE: PLEASE SEE BLDG PLAN REVIEW | | | NOTES. PLEASE CORRELATE PLANS/PAPERWORK | | | FOR COTTAGES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
11:44 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2004-01-08 |
Time |
12:13 |
Sent To |
P |
|
| Notes |
| 2004-01-08 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | ON THE PLAN FOR CODE COMPLIANCE AS | | | NOTED. | | | | | | 1} THE RISER DIAGRAM SHOWS THE 200 AMP | | | PANEL AS NEW AND LISTS IT AS EXISTING | | | ON THE NOTE.IT IS AGAIN LISTED AS "NEW" | | | AT THE SITE LOCATION.PLEASE CORRELATE. | | | | | | 2} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALL-ED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BERATED FOR THE AVAILABLE FAULT | | | CURRENT. | | | PER 110.9/215.5 | | | | | | 3} THE PANEL SCEDULE APPEARS TO HAVE THE | | | BREAKER AND BREAKER AMPSINCORRECT FOR | | | THEIR EQUIPMENT SERVED. | | | | | | 4} THE #6 WIRE SHOWN ON A 100 AMP | | | BREAKER (COND UNITS) DOES NOT COMPLY | | | WITH 310.16. | | | | | | 5} THE NEUTRAL FEEDING PANEL "B" IS | | | SHOWN AS #3/0,PLEASE VERIFY. | | | | | | 6} PLEASE SUBMIT PANEL SCHEDULES FOR ALL | | | PANELS SO THAT CODE COMPLIANCE OF | | | CIRCUITS AND OCP CAN BE DETERMINED. | | | | | | 7} PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210.52C 1,2,3,4,AND 5. | | | | | | 8} PLEASE SEE MISSING RECEPTS FOR | | | FRONT AND/OR REAR OF DWELLING. | | | 210.52E | | | | | | 9} PLEASE SEE MISSING RECEPT REQ'D | | | FOR A/C EQUIPMENT. 210.63 | | | | | | 10} PLEASE ADD THE SMOKE DETECTOR ON THE | | | FIRST FLOOR AT THE STAIR TO COMPLY WITH | | | 905.2.2 FBC AND NFPA-72 | | | | | | 11} INCREASE THE BUILDING PERMIT | | | VALUATION PER 104.6.5 CWPB AMMENDMENTS | | | TO THE FBC, ATTACHED. | | | | | | 12} ONLY ONE SET OF DRAWINGS ARE SEALED | | | BY THE ENG. ON SHEET E-1.ALSO NOTE THAT | | | SHEETS A-1 & A-2 ARE NOT SIGNED AND | | | SEALED BY THE ENGINEER OF RECORD. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-03 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-03 |
Time |
09:37 |
Sent To |
E |
|
| Notes |
| 2004-03-03 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-20 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
11:44 |
Sent To |
E |
|
| Notes |
| 2004-02-06 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-20 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-29 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2004-02-20 00:00:00 | TO BT DESK/RESUB | | 2003-12-29 00:00:00 | TO BT DESK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-10 |
Time |
06:03 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-04 |
Time |
16:55 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-03-04 |
Time |
16:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-04 |
Time |
13:27 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-02-12 |
Time |
14:30 |
Sent To |
B |
|
| Notes |
| 2004-02-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | 1) SHT A-2 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENT. TUB IN MASTER | | | BATH NOT VENTED. SEE RED LINE FOR | | | CORRECT VENTING. | | | | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-02-09 |
Time |
12:09 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-09 |
Time |
18:50 |
Sent To |
M |
|
| Notes |
| 2004-01-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT E-1 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS, NOR DOES IT | | | REFLECT THE FLOOR PLAN. | | | A) BATH #2 SHOWS A TUB ON FLOOR PLAN. | | | BUT SHOWS SHOWER ON RISER. | | | B) BATH #2 TUB AND LAV NOT VENTED. | | | C) MASTER BATH LAVS NOT VENTED AND NOT | | | IN M/BATHROOM. | | | D) MASTER BATH TUB NOT VENTED. | | | 2) SEE RED LINE CORRECTIONS AND EXAMPLE | | | FOR MASTER BATH RISER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-02-19 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-20 |
Time |
15:22 |
Sent To |
I |
|
| Notes |
|
|