Plan Review Details - Permit 03121401
Plan Review Stops For Permit 03121401
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-06-30 Cont ID  
Sent By jwitmer Date 2004-06-30 Time 12:55 Rev Time 0.55
Received By jwitmer Date 2004-06-30 Time 12:54 Sent To PC
Notes
2004-06-30 00:00:00TRUSS DRAWINGSOK

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2004-06-29 Cont ID  
Sent By jwitmer Date 2004-06-29 Time 16:52 Rev Time 0.55
Received By jwitmer Date 2004-06-29 Time 16:52 Sent To PC
Notes
2004-06-29 00:00:00SHOP DRAWINGS GREAT DANE PETROLEUM
 STEEL JOISTOK JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-06-18 Cont ID  
Sent By csiegber Date 2004-06-28 Time 09:17 Rev Time 0.50
Received By jwitmer Date 2004-06-18 Time 14:51 Sent To PC
Notes
2004-06-18 00:00:00WIND LOAD STEEL POLESJW

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-05-05 Cont ID  
Sent By jwitmer Date 2004-05-05 Time 13:37 Rev Time 0.55
Received By jwitmer Date 2004-05-05 Time 13:37 Sent To  
Notes
2004-05-05 00:00:00ROOF SLAB HOLLOW CORE PLANKING SHOP DRAW
 INGSOK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-05-04 Time 14:50 Rev Time 2.25
Received By jwitmer Date 2004-04-26 Time 12:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-18 Cont ID  
Sent By jwitmer Date 2004-03-18 Time 15:02 Rev Time 3.00
Received By jwitmer Date 2004-03-18 Time 15:02 Sent To  
Notes
2004-03-18 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03121401
 ADD: 1921 OKEECHOBEE BLVD
 CONT: GREAT DANE PETROLEUM
 TEL: (954)214-7530
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
 ACTION: DENIED
  
 1) PRODUCT APPROVAL REQUIRED UNDER THE
 STATEWIDE SYSTEM REQUIRE THE CORRECT
 REPORT AND COVERSHEET FROM THE STATE.
  
 A) STORM SHUTTERS- TOWN AND COUNTRY,
 COVERPAGE FROM STATE WEBSITE IS FOR A
 "SBCCI REPORT" SUBMITTED METRO-DADE.
 B) ROOFTILE- HANSON,
 COVERPAGE FROM STATE WEBSITE IS FOR A
 "SBCCI REPORT" SUBMITTED METRO-DADE.
  
 EITHER SUBMIT THE CORRESPONDING REPORT
 TO COVER PAGE OR SUBMIT FOR A LOCAL
 PRODUCT REPORT. SEE FLORIDA WEB SITE:
 WWW.FLORIDABUILDING.ORG
  
 2) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-04 Cont ID  
Sent By jwitmer Date 2004-02-04 Time 09:57 Rev Time 6.00
Received By jwitmer Date 2004-02-03 Time 16:25 Sent To PC
Notes
2004-02-04 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03121401
 ADD: 1921 OKEECHOBEE BLVD
 CONT: GREAT DANE PETROLEUM CONTRACT
 TEL: (954)214-7530
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) FIRE DISTRICT NO TYPE VI BUILDINGS
 ALLOWED IN FIRE DISTICT. SHEET A-5.1
 DETAILS FOR MANSARD AND GRAND ENTRY TO
 BE OF NONCOMBUSTIBLE CONSTRUCTION .
 F102.1
  
 2) F102.2.4 ROOF COVERINGS IN THE FIRE
 DISTRICT SHALL CONFORM TO THE REQUIRE-
 MENTS OF A CLASS A OR CLASS B ROOF
 COVERING AS DEFINED IN 1505.
  
 3) F102.2.6 EXTERIOR WALLS OF TYPE IV
 BUILDINGS SHALL HAVE A FIRE RESISTANCE
 RATING OF 2 HRS OR MORE WHEN SUCH WALLS
 ARE LOCATED WITHIN 30 FT OF A COMMON
 PROPERTY LINE OR AN ASSUMED PROPERTY
 LINE. INDICATE COMPLIANCE WITH BLOCK
 EQUIVALENT THICKNESS SEE TABLE 709.3.1.
  
 4) F102.2.7 ARCHITECTURAL TRIM ON BUILD-
 INGS LOCATED IN THE FIRE DISTRICT SHALL
 BE CONSTRUCTED OF APPROVED NONCOMBUST-
 IBLE MATERIALS OR FIRE TREATED WOOD.
  
 5) F102.2.8 PERMANENT CANOPIES MAY
 EXTEND OVER ADJACENT OPEN SPACES PRO-
 VIDED, THE CANOPY AND ITS SUPPORTS SHALL
 BE OF NONCOMBUSTIBLE MATERIAL, FIRE RE-
 TARDANT TREATED WOOD, WOOD OF TYPE III
 SIZES OR OF 1-HR RESISTANT CONSTRUCTION.
  
 6) F102.2.11.EXTERIOR PLASTIC VENEER IS
 NOT PERMITTED IN THE FIRE DISTRICT.
  
 7) 2603.5.1.3 WALK IN COOLERS. IN
 UNSPRINKLERED BUILDINGS, FOAM PLASTIC
 HAVING A THICKNESS THAT DOES NOT EXCEED
 4INCHES AND A MAXIMUM FLAME SPREAD OF 75
 IS PERMITTED IN WALK-IN COOLERS OR
 FREEZER UNITS WHERE THE AGGREGATE FLOOR
 AREA DOES NOT EXCEED 400 SQ FT AND THE
 FOAM PLASTIC IS COVERED BY A METAL FAC-
 ING NOT LESS THAN 0.032" THICK ALLUMIN-
 IUM OR CORROSION-RESISTANT STEEL HAVING
 A MINIMUM BASE METAL THICKNESS OF
 0.016".
 THE TOTAL OR AGGREGATE SQ. FOOTAGE IS
 APPROXIMATELY 518 SQ. FT. REQUIRING THE
 BUILDING TO BE FIRE SPRINKLERED.
 ALSO SEE 2603.5.1.2(4).
  
 8) A SEPERATE PERMIT WILL BE REQUIRED
 FOR THE CANOPY, ONLY SHEET IN THE PLANS
 IS "CP-1" NO INFORMATION ON THE STRUC-
 TURAL SYSTEMS OF THE CANOPY. CANOPIES
 SHALL COMPLY WITH 404.3.2.
  
 9) 404.3.6 PUMP MOTORS SHALL BE ACTIVATE
 D BY A SWITH THAT CANNOT BE ENERGIED UN-
 TIL AFTER THE HOSE NOZZLE BEEN REMOVED F
 ROM ITS BOOT.
  
 10) 404.3.7 INDICATE WHERE THE MASTER
 PUMP SWITCH IS LOCATED. INDICATE WHERE
 THE SIGN MASTER PUMP SWITCH WILL BE AND
 READILY ACCESSIBLE TO THE STSTION
 ATTENDANT.
  
 11)1503.4.2 OVERFLOW DRAINS SHALL BE
 THE SAME SIZE AS ROOF DRAINS, INSTALLED
 WITH THE INLET FLOW LINE LOCATED 2"
 ABOVE THE LOWEST POINT OF THE ROOF LINE.
 OVERFLOW SCUPPERS SHALL BE A MINIMUM OF
 4"IN HEIGTH AND SHALL BE PLACED IN WALLS
 OR PARARETS WITH THE INLET FLOW LINE
 NOT LESS THAN 2" ABOVE THE ROOF SURFACE.
  
 12) 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 13)1511.7 ROOF MOUNTED MECHANICAL UNIT
 S SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGHT IN ACCORDANCE WITH TABLE 1511.7.
 MECH. 301.13 WIND RESISTANCE
 MECHANICAL EQUIPMENT, APPLIANCES AND SUP
 PORTS THAT ARE EXPOSED TO WIND SHALL BE
 DESIGNED AND INSTALLED TO RESIST THE
 WIND PRESSURES ON THE EQUIPMENT & THE
 SUPPORTS AS DETERMINED IN ACCORDANCE
 WITH THE FL BLD CODE. THIS MAY BE ACCOMP
 LISHED BY DESIGN OR BY APPLICATION OF
 SECTION 301.13.1.
  
 14) FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 15)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.MISSING REPORTS:
 A) ROOFING ASSEMBLIES
  
 16) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 17)PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 18) FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 19)FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL I
 S NOT DEFINITEY KNOWN, OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL P
 ROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 20)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 21)PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2004-06-16 Cont ID  
Sent By dpalmer Date 2004-06-16 Time 14:02 Rev Time 0.25
Received By dpalmer Date 2004-06-16 Time 14:02 Sent To  
Notes
2004-06-16 00:00:00REV FOR WIND LOADING ON POLES SENT TO
 BLDG FOR REVIEW.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-17 Cont ID  
Sent By csiegber Date 2004-06-09 Time 15:57 Rev Time 0.50
Received By dpalmer Date 2004-04-17 Time 12:45 Sent To  
Notes
2004-04-17 00:00:00STAMPED ELECTRICAL SHEETS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-03-09 Cont ID  
Sent By dpalmer Date 2004-03-09 Time 05:27 Rev Time 0.50
Received By dpalmer Date 2004-03-09 Time 05:27 Sent To  
Notes
2004-03-09 00:00:00************** UNSAT ****************
  
 1)NOTE: PLEASE SEE PANEL 'CW' IS STILL
 NOT SHOWN ON RISER DIAGRAM.
 PLEASE SEE PANEL "CW" IS SHOWN AS HAVING
 A 225A MCB NOTED AS BEING MOUNTED ON
 OUTSIDE OF BLDG. PANEL IS SHOWN HAVING
 A 116A LOAD.THE OCP FEEDING 'CW' PANEL
 FROM MDP IS SHOWN AS 100A? PLEASE
 CORRELATE.
  
 2)NOTE: PLEASE HAVE PLANS SIGNED WITH A
 COMPLETE 'SIGNATURE" . INITIALS ARE NOT
 ACCEPTABLE TO FS / FBPE'S.
 FS 471.025
  
 3)NOTE: PLEASE CORRELATE LOAD ON LOAD
 SUMMARY WITH PANELS.
  
 ** NEW NOTE**
 4)NOTE: PLEASE SEE LOAD SHOWN FOR PANEL
 "D" IS SHOWN AT 71A'S, PANEL "A" SHOWS
 A 3P 60 FEEDING PANEL "D".
 PLEASE CORRELATE.
  
 5)NOTE: PLEASE VERIFY ANY EQUIPMENT
 GROUNDING CONDUCTORS MISSING PER 250.110
 , SIZE PER 250.122. PANEL CW,
  
 PLEASE SEE FIRE REVIEW COMMENTS.
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-13 Cont ID  
Sent By dpalmer Date 2004-01-13 Time 07:51 Rev Time 1.00
Received By dpalmer Date 2004-01-13 Time 07:44 Sent To  
Notes
2004-01-13 00:00:00************* UNSAT *********
  
 1)NOTE: PLEASE SEE FIRE REVIEW NOTES, AS
 THEY WILL HAVE AN AFFECT ON ELECTRICAL
 PLANS.
  
 2)NOTE: PLEASE HAVE PLANS "SIGNED " WITH
 A COMPLETE 'SIGNATURE AS REQUIRED UNDER
 FS 471.025. FAC 61G15-23.002
 THIS OFFICE HAS RECEIVED INFORMATION
 FROM FBPE'S THAT INITIALS ARE NOT
 PERMITTEDAND/OR SIGNATURE SHOULD
 CORRELATE WITH NAME AND SIGNATURE ON
 SAID LICENSE. CONTAING A MIN OF VISABLE
 FIRST AND LAST NAME. AS ON SEAL.
  
 3)NOTE: PLEASE SHOW/IDENTIFY PANELS ON
 PLANS (LOCATIONS). PLEASE SHOW PANEL
 "CW" ON PLANS.
  
 4)NOTE: PLEASE CLARIFY/SHOW CWP AS PART
 OF THE GROUNDING ELECTRODE SYSTEM.
 250.50
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2004-03-04 Cont ID  
Sent By mamini Date 2004-03-04 Time 09:15 Rev Time 1.00
Received By mamini Date 2004-03-04 Time 09:15 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2004-01-07 Cont ID  
Sent By mamini Date 2004-01-07 Time 15:55 Rev Time 1.00
Received By mamini Date 2004-01-07 Time 15:55 Sent To  
Notes
2004-01-07 00:00:00FAILED:
 1. DUMPSTER ENCLOSURE MUST HAVE A 12'-6"
 MIN. OPENING BETWEEN THE POSTS, IF TO BE
 PICKED UP BY THE CITY.
 2. ALL PARKING STALLS MUST BE PAINTED
 WITH DOUBLE 4" WIDE PER CITY OF WPB
 REQUIREMENT.
 3. PLEASE CONTACT RODNEY COMPO AT
 837-4051 EXT. 4074 FOR INSTALLATION AND
 REQUIREMENT OF THE PROPOSED OIL,GREASE
 WATER SEPARATOR AND RECLAIM WATR SYS.
 4. PLANS SHOW EXISTING METERS AND BACK-
 FLOW PREVENTERS, ARE THEY TO BE REMOVED/
 ABANDONED?
 5. PLEASE SUBMIT CIVIL PLANS ONLY TO
 PUBLIC UTILITIES AND ENGINEERING FOR
 THEIR REVIEW ATT; MANNY GONZALEZ
 659-8040 EXT. 2306.
 6. SHEET GR-1 DRANAGE PLAN, SHOW INLET
 CONNECTIONS AND 110 LF OF EXFILTRATION.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2004-04-26 Cont ID  
Sent By nmccray Date 2004-04-26 Time 11:44 Rev Time 0.00
Received By nmccray Date 2004-04-26 Time 11:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2004-04-08 Cont ID  
Sent By mcarsill Date 2004-04-08 Time 14:51 Rev Time 0.00
Received By mcarsill Date 2004-04-08 Time 14:51 Sent To  
Notes
2004-04-08 00:00:00COULD NOT LOCATE INFORMATION
 REGARDING PREVIOUS COMMENTS MADE BY
 THE FIRE RESCUE DEPARTMENT. THIS
 WRITER EXAMINED CHART G1 AND COULD
 NOT LOCATE INFORMATION.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2004-03-02 Cont ID  
Sent By mcarsill Date 2004-03-02 Time 13:08 Rev Time 0.00
Received By mcarsill Date 2004-03-02 Time 13:08 Sent To  
Notes
2004-03-02 00:00:001) PLEASE CONTACT PALM BEACH COUNTY
 DERM 233-2400 AND HAVE THE PLANS
 STAMPED WITH REGARDS TO THE REMOVAL
 OF THE OLD FUEL TANKS AND THE
 INSTALLATION OF THE NEW ONES.
  
 2) SEPARATE PLANS AND PERMITS REQUIRED
 FOR THE HOOD, DUCT, AND EXTINGUISHING
 SYSTEM PLANNED FOR USE.
  
 3) PLEASE INDICATE MAXIMUM LENGTHS OF
 DISPENSING HOSES AND INDICATE THIRD
 PARTY LISTING.
  
 4) PLEASE INDICATE VERBAGE FOR
 EMERGENCY STOP BUTTON. COULD NOT
 LOCATE INFORMATION.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-01-09 Cont ID  
Sent By mcarsill Date 2004-01-09 Time 12:37 Rev Time 0.00
Received By mcarsill Date 2004-01-09 Time 12:37 Sent To  
Notes
2004-01-09 00:00:001) ALL RENOVATION, CONSTRUCTION, AND
 DEMOLITION TO COMPLY WITH NFPA 241.
  
 2) FUEL TANKS AND APPURTENANT EQUIPMENT
 PLANNED FOR AND INSTALLATION SHALL
 COMPLY WITH NFPA 30A.
  
 3) SEPARATE PLANS AND PERMITS REQUIRED
 FOR REMOVAL AND INSTALLATION OF FUEL
 TANKS.
  
 4) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILINGS.
  
 5) BUILDING ADDRESS REQUIRED. SIX INCH
 NUMBERS ARE REQUIRED.
  
 6) PLEASE INDICATE LOCATION OF EMERGENCY
 STOP BUTTON AND APPROPRIATE SIGNAGE
 FOR FUEL PUMPS.
  
 7) PLEASE INDICATE WARNING SIGNAGE
 LANGUAGE AT THE FUEL PUMPS.
  
 8) PLEASE INDICATE LOCATIONS OF
 FIRE EXTINGUISHERS AT FUEL PUMPS.
  
 9) PROPOSED LOCATION MAY BE LOCATED
 IN THE CITY FIRE LIMITS. CERTAIN
 RESTRICTIONS MAY APPLY. PLEASE SEE
 APPENDIX TO THE FLORIDA BUILDING CODE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2004-10-27 Cont ID  
Sent By csiegber Date 2004-10-27 Time 15:16 Rev Time 0.00
Received By csiegber Date 2004-10-27 Time 15:16 Sent To M
Notes
2004-10-27 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-07-12 Cont ID  
Sent By csiegber Date 2004-07-12 Time 15:41 Rev Time 0.00
Received By csiegber Date 2004-07-12 Time 15:41 Sent To P
Notes
2004-07-12 00:00:00TO KS BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-06-28 Cont ID  
Sent By csiegber Date 2004-06-28 Time 09:17 Rev Time 0.00
Received By csiegber Date 2004-06-28 Time 09:17 Sent To B
Notes
2004-06-28 00:00:00TO JW DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-06-28 Cont ID  
Sent By csiegber Date 2004-06-28 Time 09:15 Rev Time 0.00
Received By csiegber Date 2004-06-28 Time 09:15 Sent To B
Notes
2004-06-28 00:00:00TO JW DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-09 Cont ID  
Sent By csiegber Date 2004-06-09 Time 15:57 Rev Time 0.00
Received By csiegber Date 2004-06-09 Time 15:57 Sent To E
Notes
2004-06-09 00:00:00TO DP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-05-04 Time 14:50 Rev Time 0.00
Received By csiegber Date 2004-05-04 Time 14:50 Sent To B
Notes
2004-05-04 00:00:00TO JW DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-01 Cont ID  
Sent By csiegber Date 2004-04-01 Time 11:02 Rev Time 0.00
Received By csiegber Date 2004-04-01 Time 11:02 Sent To  
Notes
2004-04-01 00:00:00TO COMM BD#60

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-03-01 Time 10:34 Rev Time 0.00
Received By csiegber Date 2004-03-01 Time 10:34 Sent To  
Notes
2004-03-01 00:00:00TO COMM BD#39

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-04 Cont ID  
Sent By jwitmer Date 2004-02-04 Time 12:58 Rev Time 0.00
Received By jwitmer Date 2003-12-23 Time 13:11 Sent To  
Notes
2004-01-05 00:00:00TO COMM BD#35
2003-12-23 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2004-11-10 Cont ID  
Sent By pkrauss Date 2004-11-10 Time 16:40 Rev Time 0.40
Received By pkrauss Date 2004-11-10 Time 16:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-04-10 Cont ID  
Sent By csiegber Date 2004-10-27 Time 15:16 Rev Time 1.00
Received By pkrauss Date 2004-04-10 Time 12:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-03-12 Cont ID  
Sent By pkrauss Date 2004-03-12 Time 15:22 Rev Time 0.55
Received By pkrauss Date 2004-03-11 Time 13:47 Sent To  
Notes
2004-03-12 00:00:00FUEL TANK REMOVAL AND REPLACEMENT MUST
 BE APPROVED & STAMPED BY DERM.PLEASE
 SUBMIT PLANS AT 3323 BELVEDERE RD,
 BUILDING #502 OR CONTACT CHIP GREEN AT
 233-2400.
  
 PROVISO:
 PLAN SHEET M-1 DETAIL OF THE AIR HANDLER
 MOUNTING - PLAN INDICATES SECONDARY
 DRAIN TO TERMINATE TO THE EXTERIOR
 LANDSCAPE.PER 2001 FBC(M) 307.2.3,
 AUXILIARY DRAIN LINE TO TERMINATE AT A
 CONSPICUOUS POINT TO SERVE AS AN ALARM
 THAT THE PRIMARY DRAIN IS RESTRICTED.
  
 PLEASE SEE TABLE 1511.7 (BELOW) FOR
 HEIGHT REQUIREMENT FOR CONDENSING UNIT
 STANDS LOCATED ON THE ROOF.
  
 PLANS CAN BE APPROVED WHEN SUBMITTED
 WITH DERMS' APPROVAL STAMP.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-23 Cont ID  
Sent By pkrauss Date 2004-01-23 Time 15:50 Rev Time 1.00
Received By pkrauss Date 2004-01-23 Time 15:50 Sent To  
Notes
2004-01-23 00:00:00DENIED:
 1.PLANS FOR THE UNDERGROUND FUEL TANKS
 TO BE SUBMITTED TO THE PALM BEACH COUNTY
 D.E.R.M. FOR APPROVAL. SUBMIT PLANS
 AT 3323 BELVEDERE RD BUILDING #502, CHIP
 GREENE.
  
 PLEASE NOTE ADDITIONAL PERMITS REQUIRED
 FOR THE FUEL OIL AND WALK-IN COOLERS.
 WALK-IN COOLER PLANS SUBMITTED WITH
 BUILDING PLANS.
  
 2.STANDS FOR CONDENSING UNITS SHALL
 COMPLY WITH 2001 FBC 1511.7.SEE THE
 ATTACHED SCHEDULE FOR HEIGHT REQUIREMENT
 FOR STANDS.
  
 3.AUXILIARY DRAIN LINE SHALL TERMINATE
 AT A CONSPICUOUS POINT TO SERVE AS AN
 ALARM.PLEASE REVISE PLANS TO HAVE
 AUXILIARY DRAIN LINE TERMINTE TO COMPLY
 WITH 2001 FBC(M) 307.1.3.
  
 4.FAN SHUTDOWN BY DUCT SMOKE DETECTOR
 WITH NOTIFICATION TO ALARM/STROBE IN
 NORMALLY OCCUPIED AREAS REQUIRED PER
 NFPA 90A 4-4.4.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-07-12 Time 15:41 Rev Time 0.50
Received By kstevens Date 2004-04-26 Time 12:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-04-10 Cont ID  
Sent By kstevens Date 2004-04-10 Time 14:46 Rev Time 1.00
Received By kstevens Date 2004-04-10 Time 14:46 Sent To  
Notes
2004-04-10 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FROM PREVIOUS REVIEW: SHTS L-1, L-2, &
 L-3 SEAL SHALL BE PRESSED HARD ENOUGH TO
 BE ABLE TO READ REQUIRED INFORMATION ON
 THE SEAL. FAC 61G1-16.001 - FS 481.221
 UNABLE TO GLEAN ANY INFORMATION FROM THE
 IMPRESSIONS ON ALL BUT ONE SHEET AND ON
 THAT SHEET ALL INFORMATION WAS NOT
 TOTAL.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-03-09 Cont ID  
Sent By kstevens Date 2004-03-09 Time 10:38 Rev Time 1.00
Received By kstevens Date 2004-03-06 Time 14:45 Sent To  
Notes
2004-03-09 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT A-1 WOMEN'S AND MEN'S TOILET
 ROOMS. THE TURNING AREA SHALL BE UNOB-
 STRUCTED PER SECTION 11-4.22.3. THE
 WATER CLOSETS SHALL NOT BE IN TURNING
 AREAS.
 2) SHT P-1 THE FLOOR SINKS ARE STILL
 SAFE WASTED INTO THE FLOOR DRAINS. THIS
 IS NOT APPROVED. SEE RED LINE CORRECTION
 AND CORRECT.
 3) SHT L-2 ALL HAND DRAWN CORRECTIONS OF
 A SIGNED AND SEALED PLAN SHALL BE DATED
 AND SIGNED BY ARCHITECT OF RECORD. SEE
 CONTROLLER & RAIN SENSOR.
 4) SHTS L-1, L-2, & L-3 SEAL SHALL BE
 PRESSED HARD ENOUGH TO BE ABLE TO READ
 THE INFORMATION REQUIRED ON SEAL.
 5) ALL APPLICABLE SHEETS, INITIALS ARE
 NOT APPROVED ON SEALS. A SIGNATURE IS
 REQUIRED PER FAC 61G15-23.002 & FAC
 61G1-16.003 - FS 471.025 & FS 481.221
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-01-23 Cont ID  
Sent By kstevens Date 2004-01-23 Time 08:21 Rev Time 1.50
Received By kstevens Date 2004-01-22 Time 18:45 Sent To  
Notes
2004-01-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SHT U-1 GREASE INTECEPTOR AND OIL
 INTECEPTOR SHALL BE SIZED BY RODNEY
 COMPO, ENVIRONMENTAL COMPLIANCE PER
 WASTE ORDINANCE #2938-96. CONTACT HIM AT
 (561) 837-4074.
 2) SHT A-1 WOMEN'S AND MEN'S TOILET
 ROOMS ARE NOT LARGE ENOUGH. MINIMUM 5'3"
 WIDE ROOM REQUIRED. SEC. 405.3.1 AND
 FIGURE 28 IN CHAPTER 11.
 3) SHT A-7 CALLS FOR 3 HAND SINKS, (#10)
 AND ONLY ONE SHOWN. PLEASE CLAIRFY.
 SEC 104.2.1
 4) SHT P-1 SANITARY SEWER ISOMETRIC,
 SAFE WASTES ARE NOT APPROVED. INDIRECT
 WASTE SHALL DRAIN INTO A FLOOR SINK OR
 A HUB DRAIN. SEC 802.3 OR 802.3.2.
 5) SHT P-1 WATER RISER DIAGRAM, WATER
 HAMMER ARRESTORS SHALL BE LOCATED NEAR
 THE FIXTURES IN AN "EFFECTIVE RANGE" NOT
 IN THE CEILING AS SHOWN. PDI-WH 201 AND
 MANUF. INSTALLATION INSTRUCTIONS.
 6) L-2 UNABLE TO LOCATE RAIN BIRD TIME
 CONTROLLER AND TORO RAIN SENSOR SWITCH.
 PLEASE INDICATE LOCATION ON PLANS. SEC.
 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-04-07 Cont ID  
Sent By ajones Date 2004-04-07 Time 13:40 Rev Time 0.25
Received By ajones Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-01-05 Cont ID  
Sent By ajones Date 2004-01-05 Time 09:23 Rev Time 0.25
Received By ajones Date   Time   Sent To  
Notes
***NONE***