Plan Review Details - Permit 03121380
| Plan Review Stops For Permit 03121380 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-01-05 |
Time |
15:30 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-01-05 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-05 |
Time |
14:34 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2003-12-30 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | DENIED | | | 1.FBC 1503.4 ROOF DRAINAGE-UNLESS | | | ROOFS ARE SLOPED TO DRAIN OVER ROOF | | | EDGES, ROOF DRAINS SHALL BE INSTALLED AT | | | EACH LOW POINT OF THE ROOF.WHERE | | | REQUIRED FOR ROOF DRAINAGE, SCUPPERS | | | SHALL BE PLACED LEVEL WITH THE ROOF | | | SURFACE IN A WALL OR PARAPET.THE | | | SCUPPER SHALL BE LOCATED AS DETERMINED | | | BY THE ROOF SLOPE AND CONTRIBUTING ROOF | | | AREA. | | | 2. FBC 1511.6.4.2 A SCUPPER SHALL BE | | | SIZED IN ACCORDANCE WITH THE FBC | | | 3.FPC 1503.4.4DOWNSPOUTS SHALL | | | DISTCHARGE AT LEAST 1 FOOT AWAY FROM | | | THE STRUCTURE SIDEWALL, WHETHER BY | | | UNDERGROUND PIPING, TAIL EXTENTIONS, OR | | | SPLASH BLOCKS.GUTTERS WITH DOWNSPOUTS | | | ARE REQUIRED ON ALL BUILDINGS WITH EAVES | | | OF LESS THAN 6" HORIZONTAL PROJECTION | | | EXCEPT FOR GABLE END RAKES OR A ROOF | | | ABOVE ANOTHER ROOF. | | | 4.SUBMIT CALC'S FOR PRIMARY AND | | | SECONDARY ROOF DRAINS. | | | 5.SUBMIT SOUTH ELEVATION DRAWING | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-22 |
Time |
15:50 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-12-23 |
Time |
07:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-05 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-05 |
Time |
14:34 |
Sent To |
B |
|
| Notes |
| 2004-01-05 00:00:00 | TO AL DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-22 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-22 |
Time |
15:40 |
Sent To |
E |
|
| Notes |
|
|
|