Plan Review Details - Permit 03121378
Plan Review Stops For Permit 03121378
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-02-19 Cont ID  
Sent By lmartine Date 2004-02-19 Time 12:05 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2004-02-19 00:00:00 
 PROVISO
 -------
  
 SUBMIT NEW PRODUCT TEST REPORT FOR
 IMPACT RATED GLAZING.
  
 REVISE WALL SECTION DETAIL, 1/2'
 PLYWOOD NOT PERMITED PER FIRE DISTRICT
 REGULATIONS.
  
  
  
  
  
  
 LUIS MARTINEZ
 8056710

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-14 Cont ID  
Sent By jwitmer Date 2004-01-14 Time 14:38 Rev Time 1.10
Received By jwitmer Date 2004-01-14 Time 14:38 Sent To  
Notes
2004-01-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03121378
 ADD: 2161 PALM BEACH LAKES BLVD
 CONT: JANIS SERVICES
 TEL: (561)540-8977
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
 REFILE NOC, WHEN WORK HAS NOT STARTED
 WITHIN 90 DAYS OF FILINGNOC HAS TO BE
 RERECORDED.
  
 2)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 DISCREPANCY, SQUARE FOOT AREA, PERMIT
 APP 1565 VS 829 ON PLANS AREA AFFECTED.
 USING THE 829 THE EXITING MEETS CODE,
 IF THE 1565 IS USED 2 MEANS OF EGRESS
 ARE REQUIRED.
  
 3) THE PRODUCT TESTING REPORTS ARE MISS-
 ING THE FLORIDA PRODUCT APPROVAL COVER
 SHEET.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-29 Cont ID  
Sent By btrobaug Date 2004-03-29 Time 17:36 Rev Time 0.50
Received By btrobaug Date 2004-03-29 Time 17:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-05 Cont ID  
Sent By dpalmer Date 2004-01-05 Time 06:01 Rev Time 0.33
Received By dpalmer Date 2004-01-05 Time 05:59 Sent To  
Notes
2004-01-05 00:00:00PASSED PENDING FIRE REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-02-05 Cont ID  
Sent By nmccray Date 2004-02-05 Time 16:02 Rev Time 0.00
Received By nmccray Date 2004-02-05 Time 16:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-01-08 Cont ID  
Sent By nmccray Date 2004-01-08 Time 10:20 Rev Time 0.00
Received By nmccray Date 2004-01-08 Time 10:20 Sent To  
Notes
2004-01-08 00:00:00************DENIED**********************
 WHAT WILL BE THE OCCUPANT LOAD IN THIS
 OUTSIDE BAR WITH STANDING AND WAITING
 AREA. A SECOND EXIT GATE MAYBE REQUIRED.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-16 Cont ID  
Sent By csiegber Date 2004-03-16 Time 16:34 Rev Time 0.00
Received By csiegber Date 2004-03-16 Time 16:34 Sent To P
Notes
2004-03-16 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-04 Cont ID  
Sent By csiegber Date 2004-02-04 Time 10:43 Rev Time 0.00
Received By csiegber Date 2004-02-04 Time 10:43 Sent To  
Notes
2004-02-04 00:00:00TO COMM BD#29

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-19 Cont ID  
Sent By csiegber Date 2004-02-19 Time 12:14 Rev Time 0.00
Received By lmartine Date 2003-12-22 Time 15:38 Sent To  
Notes
2004-01-02 00:00:0012/22/03 TO Z
 TO COMM BD#42

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-01-07 Cont ID  
Sent By pkrauss Date 2004-01-07 Time 12:24 Rev Time 0.15
Received By pkrauss Date 2004-01-07 Time 12:24 Sent To  
Notes
2004-01-07 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-03-20 Cont ID  
Sent By kstevens Date 2004-03-20 Time 07:21 Rev Time 0.50
Received By kstevens Date 2004-03-20 Time 07:21 Sent To  
Notes
2004-03-20 00:00:00REVISION OK - ADDED FLOOR DRAIN

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-02-06 Cont ID  
Sent By csiegber Date 2004-03-16 Time 16:35 Rev Time 0.50
Received By kstevens Date 2004-02-06 Time 17:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-01-14 Cont ID  
Sent By kstevens Date 2004-01-14 Time 07:37 Rev Time 0.50
Received By kstevens Date 2004-01-14 Time 07:37 Sent To  
Notes
2004-01-14 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SPECIFICATION SHEETS FROM HOTEL &
 RESTURANT DIVISION SHALL BE SUBMITTED ON
 EACH SET OF PLANS.
 2) ADDITIONAL SQUARE FOOTAGE MAY REQUIRE
 ADDITIONAL PLUMBING FACILITIES. INDICATE
 EXISTING SQUARE FOOTAGE OF SPACE AND
 SHOW EXISTING TOILET FACILITIES.
 3) DRAINAGE SHALL CONNECT TO BLDG. DRAIN
 OR BRANCH LINE NOT FLOOR DRAIN AS STATED
 ON SHT A2.0
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-02 Cont ID  
Sent By csiegber Date 2003-12-22 Time 15:39 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***