Plan Review Details - Permit 03121023
Plan Review Stops For Permit 03121023
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-03-24 Cont ID  
Sent By alange Date 2004-03-24 Time 10:01 Rev Time 0.66
Received By alange Date 2004-03-24 Time 10:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-03-03 Cont ID  
Sent By csiegber Date 2004-03-23 Time 15:21 Rev Time 1.50
Received By alange Date 2004-03-03 Time 10:02 Sent To  
Notes
2004-03-03 00:00:00DENIED
 1. NOC EXPIRED FS. 713 SUBMIT A NEW NOC
 THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
 2.PROJECT VALUATION TOO LOW SUBMIT A
 SIGNED CONTRACT VERIFYING WORK TO BE
 COMPLETED ALONG WITH TOTAL AMOUNT OF
 PROJECT INCLUDED.
  
 ANY QUESTIONS CALL ME.
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-02-02 Cont ID  
Sent By kstevens Date 2004-02-27 Time 08:48 Rev Time 1.00
Received By alange Date 2004-02-02 Time 11:18 Sent To  
Notes
2004-02-02 00:00:00DENIED
 1.SHUTTER PRODUCT APPROVALS SUBMITTED
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 2.IMPACT PROTECTION REQUIRED FOR
 SKYLIGHT.PRODUCT APPROVAL DOES NOT
 SPECIFY THAT IT IS IMPACT RESISTANT.
 3.ACCORDING TO THE WEST PALM BEACH
 CODE SEC. 94-546 PROVISIONS FOR FLOOD
 HAZARD REDUCTION.SUBSTANTIAL
 IMPROVEMENTS REQUIRE ENTIRE BUILDING TO
 BE BROUGHT UP TO FLOOD ZONE REQUIREMENTS
 FOR THE CODE.
 CALCULATION OF ALL WORK DONE DURING
 ANY 12 MONTH PERIOD.YOUR STILL OVER
 THE 50% THRESHOLD.
 4.SUBMIT FINISH FLOOR ELEVATATION.
 FINISH FLOOR ELEVATION IN THIS ZONE IS
 7FT. 6IN.
 ANY QUESTONS PLEASE CALL
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-16 Cont ID  
Sent By pkrauss Date 2004-01-05 Time 15:04 Rev Time 3.00
Received By alange Date 2004-01-16 Time 11:50 Sent To  
Notes
2004-01-16 00:00:001.SKYLIGHT PRODUCT APPROCALS NOT ON
 THE FBC PRODUCT APPROVAL SITE.
 COMPLETETHE ATTACHED FORM FOR SITE
 SPECIFIC
 INFORMATION.
 2.IMPACT PROTECTION REQUIRED FOR
 SKYLIGHT.
 3.ACCORDING TO THE WEST PALM BEACH
 CODE SEC. 94-546 PROVISIONS FOR FLOOD
 HAZARD REDUCTION.SUBSTANTIAL
 IMPROVEMENTS REQUIRE ENTIRE BUILDING TO
 BE BROUGHT UP TO FLOOD ZONE
 REQUIREMENTS OF THE CODE.
 4.SUBMIT FINISH FLOOR ELEVATION.
 FINISH FLOOR ELEVATION IN THIS ZONE IS
 7 FT. 6" .
 ANY QUESTIONS PLEASE CALL
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-02-25 Cont ID  
Sent By dpalmer Date 2004-02-25 Time 12:35 Rev Time 0.50
Received By dpalmer Date 2004-02-25 Time 12:34 Sent To P
Notes
2004-02-25 00:00:00NOC HAS EXPIRED SINCE WORK HAS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING
 NOC.FS 713

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-02-02 Cont ID  
Sent By csiegber Date 2004-02-17 Time 16:26 Rev Time 0.75
Received By dpalmer Date 2004-02-02 Time 09:12 Sent To  
Notes
2004-02-02 00:00:00**************** UNSAT **************
  
 1)NOTE: PLEASE SEE 310.15B6 FOR SIZING
 OF SEC'S. PLANS MENTION 350A SERVICE AND
 310.15B6 SHOWS 250MCM RATED FOR 300A'S??
 PLEASE ADJUST.
  
 2)NOTE: PLEASE SEE OCP AND AWG FOR AHU
 SHOWN @ 10KW. PLEASE SEE 424.3 FOR MIN
 OF 125% FOR OCP.
  
 3)NOTE: PLEASE SEE 210.52 FOR RECEPT
 MISSING 2ND FLR, 2' OF WALL SPACE.
  
 4)NOTE: PLEASE SEE 210.52E FOR MISSING
 RECEPT IN FRONT OF DWELLING.
  
 5)NOTE: PANEL SCHEDULE NOW SHOWS ARC
 FAULT PROTECTION FOR MAST BEDRM AND
 BATH(S). MASTER BEDROOM IS REQ'D BUT NO
 OTHER BEDROOMS ARE LISTED?? PLEASE ALSO
 NOTE: 210.12 DOES NOT REQUIRE ARC FAULT
 PROTECTION FOR BATHS BUT HOWEVER MAY BE
 INSTALLED. PLEASE LIST ALL BEDROOMS.
  
 6)NOTE: PLEASE SEE AWG AND OCP FOR
 DRYER, SHOWN AS 40A AND #8 FOR 5KW.MAX
 OCP IS 150% FOR WATER HEATER.
  
 7)NOTE: PLEASE SEE ORIG PLANS, REQ'D
 TURQUOISE ENG TO PROVIDE CA # ON TITLE
 BLOCK AND REQ'D A COMPLETE SIG. NOW
 PLANS DO NOT HAVE TITLE BLOCK AT ALL??
 PLEASE SEE THAT THIS COMMENT STILL STAND
 -S FOR ALL PLANS AND ALL TRADES, WEATHER
 OR NOT COMMENT IS MADE BY OTHER REVIEWER
 -S. PLEASE SEE FS 471.023 FOR REQ'D
 CA#. PLEASE SEE THAT WE REVIEWED RECORDS
 WITH FBPE'S AND HAVE FOUND NO LICENSE
 # FOR TURQUOISE ENG. IF INDEED SAID
 ENGINEERING FIRM IS LICENSED, THEN
 PLEASE PROVIDE ALL LICENSE INFORMATION
 ON REQ'D TITLE BLOCK AS REQ'D UNDER
 FSAND FAC 61G15-23.002.
 IF THERE ARE ANY QUESTIONS ON THIS,
 PLEASE CALL.
  
 8)NOTE: PLEASE SEE 210.63 FOR RECEPT
 REQ'D IN ATTIC FOR AHU.
  
 9)NOTE: PLEASE SEE COPY OF FS 553.80(2)
 (B) ALSO GIVEN BY PLUMB PLAN REVIEW.
  
 10)NOTE: PLEASE REMOVE ALL OLD/VOIDED
 SHEETS AND INSERT ANY NEW SHEETS INTO
 TWO COMPLETE SETS FOR REVIEW AND STAMP-
 -ING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-12-31 Cont ID  
Sent By kstevens Date 2004-01-29 Time 12:10 Rev Time 0.75
Received By dpalmer Date 2003-12-31 Time 11:56 Sent To M
Notes
2003-12-31 00:00:00************** UNSAT *****************
  
 1)NOTE: PLEASE SEE THAT PLANS SHOW
 EXISTING PANEL "A" INSIDE AND NEW/FUTURE
 150A PANEL OUTSIDE. PLEASE SEE THAT PER
 230.72 THIS IS NOT/WILL NOT BE PERMITTED
 MAINS ARE REQ'D TO BE GROUPED.
  
 2)NOTE: PLEASE ALSO SEE/ NOTE, NO MORE
 -THAN 8' OF UNPROETCTED CONDUCTORS ARE
 PERMITTED INSIDE HOUSE. 230.70
  
 3)NOTE: PLEASE SEE 210.52 FOR RECEPT
 SPACING. THERE ARE A FEW MISSING.
  
 4)NOTE: PLEASE SEE NFPA-72 8-1.4.2 FOR
 MISSING SD INSIDE AND OUTSIDE ALL
 SLEEPING ROOMS AND ON EACH LEVEL OF A
 MULTI-LEVEL RESIDENCE.
  
 5)NOTE: PLEASE SEE 210.52E FOR MISSING
 RECEPTS.
  
 6)NOTE:PLEASE LIST THE REQ'D ARC FAULT
 PROTECTED CIRCUITS PER 210.12 ON A
 SUBMITTED PANEL SCHEDULE. (TO BE SUBMITT
 -ED). PLEASE SHOW ALL MIN REQ'D CIRCUITS
 , OCP, AWG PER 2002 NEC.
  
 7)NOTE: PLEASE SEE THAT WATER HEATER
 IS NOT PERMITTED IN CLOTHES CLOSET PER
 422.17.
  
 8)NOTE: PLEASE SEE BOTTOM OF LOAD
 CALCUALTIONS, SHOWS SERVICE TO BE 150A
 AND YET SERVICE IS SHOWN AS POSSIBLE
 350A'S. PLEASE SEE 310.15B6 FOR MIN
 SIZE FOR SERVICE ENT CONDUCTORS.
 SIZED TO BE MIN 350 MCM.
 PLEASE ALSO SEE 250.66 FOR MIN SIZE
 OF GROUNDING ELECTRODE CONDUCTOR PER
 SEC'S.
  
 9)NOTE: PLEASE LIST THE REQ'D DEDICATED
 BATH CIRCUITS PER 210.52D/210.11C3
 ON SUBMITTED PANEL SCHEDULE.
  
 10)NOTE: PLEASE SEE FAC 61G15-23.002
 FOR LICENSE #'S AND ALL INFORMATION
 REQ'D ON TITLE BLOCK. PER FS 471
 PLEASE ALSO NOTE, A COMPLETE SIGNATURE
 MUST BE ON PLANS ALSO. INITIALS ARE
 NOT ACCEPTABLE PER FBPE'S.
 MUST BE SIGNED AS WAS ON LICENSE.
  
 11)NOTE: PLEASE SHOW A/C EQUIPMENT ON
 PLANS AND REQ'D DISC'S PER 440.11.
 PLEASE ALSO SEE 210.70 AND 210.63 FOR
 LTS/ RECEPT FOR EQUIPMENT.
  
 PLEASE SEE THAT ELECTRICAL PLANS HAVE
 BEEN VOIDED. PLEASE SUBMIT THE ABOVE
 INFORMATION FOR REVIEW. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-12-23 Cont ID  
Sent By kstevens Date 2003-12-31 Time 11:28 Rev Time 0.50
Received By btrobaug Date 2003-12-23 Time 12:00 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-12-14 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 14:18 Rev Time 0.00
Received By mjacobs Date 2004-12-14 Time 14:12 Sent To P
Notes
2004-12-14 00:00:00SENT TO "P" BOX./RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 15:21 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 15:21 Sent To B
Notes
2004-03-23 00:00:00TO AL DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-17 Cont ID  
Sent By csiegber Date 2004-02-17 Time 16:26 Rev Time 0.00
Received By csiegber Date 2004-02-17 Time 16:26 Sent To E
Notes
2004-02-17 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-01-27 Time 12:41 Rev Time 0.00
Received By csiegber Date 2004-01-27 Time 12:40 Sent To P
Notes
2004-01-27 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-23 Cont ID  
Sent By csiegber Date 2003-12-23 Time 10:27 Rev Time 0.00
Received By csiegber Date 2003-12-23 Time 10:27 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-17 Cont ID  
Sent By mmclean Date 2003-12-22 Time 16:53 Rev Time 0.00
Received By csiegber Date 2003-12-17 Time 16:14 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-01 Cont ID  
Sent By pkrauss Date 2004-03-01 Time 07:16 Rev Time 0.10
Received By pkrauss Date 2004-03-01 Time 07:16 Sent To  
Notes
2004-03-01 00:00:00NO CHANGES FROM 1ST SUBMITTAL/PLANS
 APPROVED 1/5/04

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-05 Cont ID  
Sent By kstevens Date 2004-02-27 Time 08:48 Rev Time 0.33
Received By pkrauss Date 2004-01-05 Time 13:23 Sent To B
Notes
2004-01-05 00:00:00PROVISO:
 WHEN CALCULATING THE RETURN AIR FROM THE
 MASTER BEDROOM, INCLUDE THE TOTAL SUPPLY
 AIR TO THE MASTER BEDROOM AREA PER 2001
 FBC(M) 601.4 EXCEPTION #1 (SEE BELOW)

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-02-27 Cont ID  
Sent By kstevens Date 2004-02-27 Time 08:46 Rev Time 0.33
Received By kstevens Date 2004-02-27 Time 08:46 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-01-29 Cont ID  
Sent By dpalmer Date 2004-02-25 Time 12:35 Rev Time 0.50
Received By kstevens Date 2004-01-29 Time 11:55 Sent To E
Notes
2004-01-29 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMIN. CODE
 FLORIDA STATUTES
  
 1) ONLY ONE SET OF PLANS RESUBMITTED AND
 NEW SHEETS A4 & A5 NOT INSERTED INTO THE
 PLANS. REMOVE OLD SHEETS FROM PLANS AND
 INSERT NEW SHEETS. SUBMIT TWO COMPLETE
 SETS OF PLANS FOR REVIEW. SEC. 104.2.1.
 2) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN, NOR DOES IT MEET
 CODE REQUIRMENTS. FIRST FLOOR TUB AND
 SHOWER ARE NOT VENTED. 901.2.1 AND LAY-
 OUT OF FIXTURES DOES NOT REFLECT THE
 FLOOR PLAN. (SEE ATTACHED SHEET FOR AN
 EXAMPLE OF A CORRECT RISER SECTION OF
 FIRST FLOOR BATHROOMS THAT REFLECT THE
 FLOOR PLAN AND MEET CODE REQUIREMENTS.
 3) PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
  
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
  
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS471.023
 4) ALL SHEETS SHALL BE SIGNED NOT JUST
 SHEETS A4 & A5.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-12-31 Cont ID  
Sent By csiegber Date 2004-01-27 Time 12:41 Rev Time 0.50
Received By kstevens Date 2003-12-31 Time 11:00 Sent To E
Notes
2003-12-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLA. ADMIN. CODE
 FLA. STATUTES
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE COMPLIANCE, NOR DOES DOES IT RE-
 FLECT THE FLOOR PLAN. SECOND FLOOR MAST-
 ER BATH TUB AND SHOWER ARE NOT VENTED.
 FLOOR PLAN SHOWS W/C, TUB ON RIGHT SIDE
 WITH LAV ON LEFT SIDE FIRST BATH ON THE
 FLOOR PLAN, BUT THE RISER SHOWS A LAV
 FIRST, WITH A W/C ON THE LEFT SIDE.
 THE SECOND BATH SHOWS A LAV, WITH A
 SHOWER ON THE RIGHT SIDE AND A W/C ON
 THE LEFT SIDE UPSTREAM OF THE FIRST BATH
 ROOM, WHEREAS THE RISER DOES NOT SHOW
 A LAV AND THE W/C AND SHOWER ARE ON THE
 SAME SIDE. PLEASE SUBMIT A RISER DIAGRAM
 THAT REFLECTS THE FLOOR PLAN.
 2) IF PRACTICING THROUGH A DULY AUTHROI-
 ZED ENGINEERING BUSINESS, ENGINEERS
 SHALL LEGIBLY INDICATE THEIR NAME AND
 LICENSE NUMBER, AS WELL AS, THE NAME,
 ADDRESS AND CERTIFICATE OF AUTHORIZATION
 NUMBER OF THE ENGINEERING BUSINESS ON
 EACH SHEET. 61G15-23.002(2)
 3) THE SIGNATURE OF THE ENGINEER SHALL
 BE AFFIXED TO THE SEAL WITH THE DATE.
 PER FBPE RULING, INITALS ARE NOT ACCEPT-
 ABLE. 61G15-23.002(1) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-22 Cont ID  
Sent By csiegber Date 2003-12-17 Time 16:14 Rev Time 0.00
Received By mmclean Date 2003-12-22 Time 16:53 Sent To I
Notes
***NONE***