| Plan Review Stops For Permit 03121021 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-06 |
Time |
16:09 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-04-06 |
Time |
16:09 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-22 |
Time |
10:52 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2004-02-20 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-27 |
Time |
12:07 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2004-01-27 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2004-01-27 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03121021 | | | ADD: 1016 CLARE AVE # 5 | | | CONT: SPRADLEY | | | TEL: (561)301-1004 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | SECOND REVIEW | | | ACTION: DENIED | | | | | | COMMENTS NOT ADDRESSED FROM FIRST | | | REVIEW. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-14 |
Time |
15:39 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2004-01-14 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03121021 | | | ADD: 1016 CLARE AVE | | | CONT: SPRADLEY CONST | | | TEL: (561)301-1004 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST BUILDING REVIEW | | | ACTION: DENIED | | | | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | 4HR RATED WALL BETWEEN UNITS 4 & 5. THE | | | PLANS INDICATE THE USE OF ROLL UP DOOR? | | | EXPLAINOR PROVIDE RATING ON DOOR? | | | | | | 2) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) GLASS BLOCK, WALL THICKNESS MAY | | | REQUIRE STORM SHUTTERS. | | | B) NEW ROLL UP DOOR. | | | C) NEW STOREFRONT GLASS | | | D) TELLAR STYLE STEEL DOOR | | | | | | 3)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4)11-4.8.2 SLOPE & RISE. THE LEAST | | | POSSIBLE SLOPE SHALL BE USED FOR ANY | | | RAMP. THE MAXIMUM SLOPE FOR A RAMP IN | | | NEW CONSTRUCTION SHALL BE 1 TO 12. THE | | | MAXIMUM RISE FOR RUN SHALL BE 30" (SEE | | | FIGURE 16). | | | | | | 5)11-4.8.4.(2) LANDINGS. ALL LANDINGS | | | ON RAMPS SHALL NOT BE LESS THAN 60" | | | CLEAR, & THE BOTTOM OF EACH RAMP SHALL | | | HAVE NOT LESS THAN 72" OF STRAIGHT & | | | LEVEL CLEARENCE. | | | | | | 6)11.4.8.5. HANDRAILS: IF A RAMP HAS | | | A RISE GREATER THAN 6" OR A HORIZONTAL | | | PROJECTION GREATER THAN 72", THEN IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 7)1204.2 SURROUNDING MATERIALS; | | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | | ROOMS SHALL BE LINED WITH NONABSORBANT | | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | | FLOOR. | | | | | | 8) PLANS INDICATE A SECOND AND THIRD | | | FLOOR, PLEASAE HOW EXITING. | | | | | | 9) 1016.2.1 EMERGENCY LIGHTING , PROVIDE | | | LAYOUT SHOWING STORAGE AREAS AND EGRESS | | | ROUTES, PLANS INDICATE A THIRD FLOOR BUT | | | NO INFORMATION PROVIDED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-20 |
Time |
06:34 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-04-20 |
Time |
06:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
13:06 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-03-31 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2004-03-31 00:00:00 | | | | PLEASE NOTE THAT THE BUILDING PLAN HAS | | | CHANGED. THERE CAN BE NO ELECTRICAL | | | PLANS SUBMITTED FOR REVIEW PRIOR TO THE | | | BUILDING PLAN BEING SUBMITTED FOR | | | REVIEW. | | | ALL PLANS MAY BE SUBMITTED TOGETHER TO | | | EXPEDITE THE REVIEW PROCESS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE NOTE THAT OFFICE AREAS ARE TO | | | BE CALCULATED PER 220.3(A). | | | | | | 2} PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER: | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.2(A)(1),210.19(A)(1) & | | | 210.20(A). | | | | | | 3} PANEL "A" CALCULATION REMAINS THE | | | SAME AS ON THE PERMITED SET OF PLANS, | | | BUT ACCORDING TO THE REVISION SET THERE | | | ARE IS LIGHTING AND RECEPTACLE LOADS | | | ADDED, PLEASE CORRECT. | | | | | | 4} PANEL "B" HAD A ROLLUP DOOR REMOVED | | | FROM THE PANEL , PLEASE INDICATE WHERE | | | IT IS BEING FED FROM, INCLUDE IT ON A | | | SCHEDULE AND IN THE LOAD CALC'S. | | | | | | 5} PANEL "C" IS BEING FED FROM THE MAIN | | | PANEL ON THE RISER DIAGRAM, BUT IS NOT | | | ON THAT PANEL.SCHEDULE, NO OCP OR WIRE | | | SIZE LISTED. PLEASE SHOW HOW FED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
11:11 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-01-26 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-30 |
Time |
08:51 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-12-30 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | *************** UNSAT ************ | | | | | | 1)NOTE: PLEASE CORRELATECIRCUITS #'S | | | ON PLANS AND PANEL SCHEDULES. | | | | | | 2)NOTE: PLEASE SEE THAT MEANS OF EGRESS | | | LIGHTING CONTROL MUST ALSO HAVE A MEANS | | | CONTROL FOR STAIRWAYLIGHTING FROM | | | SECOND FLR. LS101 5-8 | | | | | | 3)NOTE: PLEASE SEE FIRE REVIEW NOTES AS | | | THEY WILL HAVE A DIRECT AFFECT ON | | | ELECTRICAL PLANS. | | | | | | 4)NOTE: PLEASE CLARIFYSERVICE, SHOWN | | | AS NEW, BUT IF SERVICE EXSITING PLEASE | | | NOTE AS EXISTING. | | | | | | 5)NOTE: PLEASE CLARIFY WORK SHOP, WHAT | | | WILL BE THIS ROOM BE USED FOR. PLEASE | | | SHOW ANY CLASS LOCATIONS, IF ANY. | | | | | | 6)NOTE; PLEASE SEE 600.5 , IF BLDG WILL | | | HAVE ANY PUBLIC TRAFFIC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-04-01 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-04-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | REVISIONS DATED 3-19-04 AND 3-29-04 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-22 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-29 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-29 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2003-12-29 00:00:00 | 1) NO EXIT SIGNS DIRECTING PERSONS | | | TO THE DOOR THAT LEADS TO THE EXISTING | | | HC RAMP AND EXIT DOOR. | | | | | | 2) PLEASE EXPLAIN PURPOSE AND FUNCTION | | | FOR NEW ROLL UP DOORS. | | | | | | 3) PLEASE PROVIDE DETAILS ON EXISTING | | | EXTERIOR STAIR FROM SECOND FLOOR. | | | PLEASE INDICATE STAIR RISE AND RUN, | | | TREAD SIZE AND HANDRAIL INFORMATION. | | | | | | 4) NO EMERGENCY LIGHTING SHOWN IN | | | EXISTING HC RAMP AND EXIT AREA. | | | | | | 5) PLEASE EXPLAIN SINGLE EXIT RATIONALE | | | FROM SEVERAL OF THE ROOMS IN SPACE #5. | | | | | | 6) FOR LARGE AREAS OF THE SPACE, THERE | | | APPEARS TO BE TOO FEW EMERGENCY | | | LIGHT FIXTURES. | | | | | | 7) EXISTING ROLL-UP DOORS APPEAR TO | | | REMAIN. PLEASE INDICATE RATING, AND | | | WILL THEY BE UP OR DOWN. | | | | | | 8) NO FIRE EQUIPMENT SHOWN ON PLANS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-14 |
Time |
13:06 |
Sent To |
E |
|
| Notes |
| 2004-04-14 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-30 |
Time |
11:11 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-22 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-22 |
Time |
10:52 |
Sent To |
B |
|
| Notes |
| 2004-03-22 00:00:00 | TO JW DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-21 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-21 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2004-01-21 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-17 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2003-12-17 00:00:00 | TO COMM BD#64 |
|
|