| Plan Review Stops For Permit 03120955 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-07 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-07 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2005-02-07 00:00:00 | PROVISO | | | | | | 1) REVISIONS TO SHEETS A2, A4 AND A5 ARE | | | OK. HOWEVER STRUCTURAL SHEET S1 WILL | | | HAVE TO BE REVISED TO SHOW REVISED | | | POURED CELL LOCATIONS AND SHEET S4 TO | | | SHOW REVISED LINTEL SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-06-16 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-06-16 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2004-06-16 00:00:00 | REVISION TO CHANGE TO R-4.2 FOIL | | | INSULATION IS OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-04-28 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | BUILDING PROVISO | | | | | | 1) SUBMIT (2)SIGNED AND SEALED COPIES OF | | | THE SOIL REPORT PER FAC 61G15-35 AND | | | CITY AMENDMENTS TO FBC 1804.2.2. | | | | | | 2) SUBMIT (2) SIGNED AND SEALED COPIES | | | OF THE SURVEY. | | | | | | 3) SUBMIT STATE PRODUCT APPROVALS FOR | | | THE FOLLOWING: | | | - ARCHED FIXED GLASS WINDOWS | | | - DOUBLE INSWING ENTRY DOORS | | | - SINGLE OUTSWING STEEL PANEL DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-28 |
Time |
15:15 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-04-09 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2004-04-09 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT A SIGNED AND SEALED COPY OF | | | THE SOIL REPORT. SEE 61G15-35 FAC AND | | | CITY AMENDMENTS TO FBC 1804.2.2. | | | | | | 3) PROVIDE AT LEAST ONE FULL BATH ROOM | | | WITH A DOOR THAT HAS A 29" CLEAR OPENING | | | AS REQUIRED BY FBC 11-4.22.2. A 32" WIDE | | | DOOR IS NEEDED. | | | | | | 4) THE FOOTPRINT OF THE STRUCTURE ON THE | | | SURVEY DOES NOT MATCH THE PLANS. SUBMIT | | | A NEW SURVEY. | | | | | | 5) THE HEIGHT ADJUSTMENT COEFFICIENTS | | | LISTED IN THE TABLE ON S4 ARE INCORRECT | | | FOR EXPOSURE B AT 20',30'AND 50'. PLEASE | | | CORRECT. | | | | | | 6) SHEET A5 HAS NOTES THAT REFERENCE | | | CODE SECTIONS OF THE FBD. THIS SHOULD BE | | | FBC (FLORIDA BUILDING CODE). PLEASE | | | CORRECT. | | | | | | 7)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT | | | PRODUCT APPROVALS FOR THE FOLLOWING: | | | - SINGLE HUNG WINDOWS | | | - ONE HOUR FIRE RATED GLASS BLOCK | | | - FIXED GLASS WINDOWS | | | - ARCHED TOP WINDOWS | | | - MULLIONS | | | - OVERHEAD GARAGE DOORS | | | - DOUBLE INSWING ENTRY DOORS | | | - EXTERIOR PANEL DOOR | | | - SLIDING GLASS DOORS | | | - TRUSS CONNECTORS | | | - HURRICANE PANELS | | | | | | 8) IN ADDITION TO THE PRODUCT APPROVALS | | | FOR THE HURRICANE PANELS, SUBMIT KEY | | | PLANS AND INSTALLATION SCHEDULES. | | | SPECIFY THE MOUNT TYPE, FASTENER TYPE | | | AND FASTENER SPACING. | | | | | | 9) A SEPARATE PERMIT WILL BE REQUIRED | | | FOR ROOFING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-08 |
Time |
12:54 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-02-25 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT A SIGNED AND SEALED COPY OF | | | THE SOIL REPORT. 61G15-35 FAC AND CITY | | | AMENDMENTS TO FBC 1804.2.2. | | | | | | 3) THE FLOOR PLAN ON SHEET A2 SPECIFIES | | | GLASS BLOCK IN BATH #3 AND THE LEFT SIDE | | | ELEVATION ON A5 SHOWS A 2650 SH WINDOW. | | | PLEASE CORRECT. | | | | | | 4) THE MINIMUM SIZE FOR ATTIC ACCESS IS | | | 20"X 36" PER FBC 2309.6. PLEASE REVISE | | | DIMENSIONS ON THE PLAN. | | | | | | 5) PROVIDE AT LEAST ONE FULL BATHROOM | | | WITH A DOOR THAT HAS A 29" CLEAR OPENING | | | AS REQUIRED BY FBC CHAPTER 11. A 32" | | | WIDE DOOR IS NEEDED. | | | | | | 6) THE INFORMATION SUBMITTED FOR THE | | | GAS BBQ IS NOT ADEQUATE. THE PRODUCT | | | LISTING AND SPECS ARE REQUIRED. | | | | | | 7) THE FOOTPRINT OF THE STRUCTURE ON THE | | | SURVEY DOES NOT MATCH THE PLANS. SUBMIT | | | A REVISED SURVEY. | | | | | | 8) PROVIDE DETAILS (DRAWINGS) OF THE | | | CUSTOM WALL BRACKETS (ID# 4,4A & 4B) | | | SPECIFIED IN THE CONNECTOR SCHEDULE ON | | | S3. | | | | | | 9) SPECIFY THE MAXIMUM UPLIFT CAPACITY | | | OF THE STEEL COLUMN ON SHEET S4. | | | | | | 10) SOME OF THE ADJUSTMENT COEFFICIENTS | | | FOR EXPOSURE B HAVE INCORRECT VALUES IN | | | THE TABLE ON SHEET S4. | | | | | | 11) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT | | | PRODUCT APPROVALS FOR THE FOLLOWING: | | | - ONE HOUR FIRE RATED GLASS BLOCK | | | - SINGLE HUNG WINDOWS | | | - FIXED GLASS WINDOWS | | | - ARCHED TOP WINDOWS | | | - MULLIONS | | | - OVERHEAD GARAGE DOORS | | | - DOUBLE INSWING ENTRY DOORS | | | - EXTERIOR PANEL DOOR | | | - SLIDING GLASS DOORS | | | - TRUSS CONNECTORS | | | - HURRICANE PANELS | | | | | | 22) IN ADDITION TO THE PRODUCT APPROVALS | | | FOR THE HURRICANE PANELS, SUBMIT KEY | | | PLANS AND INSTALLATION SCHEDULES. | | | SPECIFY THE MOUNT TYPE, FASTENER TYPE | | | AND FASTENER SPACING. | | | | | | 23) A SEPARATE PERMIT WILL BE REQUIRED | | | FOR ROOFING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-23 |
Time |
11:31 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2004-01-20 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2004-01-20 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT A SIGNED AND SEALED COPY OF | | | THE SOIL REPORT. CITY AMENDMENTS TO FBC | | | 1804.2.2. | | | | | | 4) ONE HOUR FIRE RATED GLASS BLOCK IS | | | REQUIRED WITHIN 3 FEET OF THE PROPERTY | | | LINE PER FBC TABLE 600. SPECIFY THIS ON | | | THE PLANS. | | | | | | 5) GLASS BLOCK WITHIN THREE FEET OF A | | | TUB OR SHOWER ARE REQUIRED TO HAVE A | | | MINIMUM UNIFORM FACE THICKNESS OF 0.25" | | | PER FBC 2405.2. SPECIFY ON THE PLANS. | | | | | | 6) WINDOWS WITHIN THREE FEET OF A TUB OR | | | SHOWER ARE REQUIRED TO HAVE SAFETY | | | GLAZING PER FBC 2405.2. SPECIFY ON PLANS | | | THAT THE WINDOWS IN MASTER BATH ARE | | | TEMPERED. | | | | | | 7) SPECIFY THE SIZE OF THE GLASS BLOCK | | | OPENINGS. | | | | | | 8) SPECIFY THE TYPE AND SIZES OF THE | | | EGRESS WINDOWS IN THE GUEST BEDROOM. | | | | | | 9) INDICATE THE SIZES OF ALL OF THE | | | TRANSOM AND FIXED GLASS WINDOWS. | | | | | | 10) SPECIFY THE SIZE OF THE ATTIC ACCESS | | | ON THE PLANS. SEE FBC 2309.6. | | | | | | 11) PROVIDE AT LEAST ONE FULL BATH WITH | | | A DOOR THAT HAS A 29" CLEAR OPENING AS | | | REQUIRED BY FBC CHAPTER 11. | | | | | | 12) SUBMIT MANUFACTURER'S SPECS. AND | | | UL LISTING INFORMATION FOR THE GAS BBQ. | | | | | | 13) THE FOOT PRINT OF THE STRUCTURE ON | | | THE SURVEY DOES NOT MATCH THE PLANS. | | | SUBMIT CORRECTED SURVEY. | | | | | | 14) THE ROOF SHEATHING IS REQUIRED TO BE | | | NAILED AT 4"OC AT THE EDGES AND 6"OC | | | INTERMEDIATE IN ZONE 3 PER CITY AMEND. | | | TO FBC TABLE 2306.1. THE CORNERS OF HIP | | | ROOFS ARE ZONE 3. PLEASE REVISE THE NOTE | | | ON A6. | | | | | | 15) SPECIFY THE FOUNDATION FOR THE 5' | | | WALL AT THE GARDEN COURT ON S1. | | | | | | 16) PROVIDE DETAILS OF THE CUSTOM WALL | | | BRACKETS SPECIFIED IN THE CONNECTOR | | | SCHEDULE ON S3. | | | | | | 17)1609.4.3 LOAD REDUCTION. | | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | | 1609.4.1 OR 1609.4.2, THE COMBINED | | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | | FROM THE LOAD COMBINATION OF THE DEAD | | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | | EFFECTS. INCREASEIN ALLOWABLE STRESS SPE | | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | | CODE OR A REFRENCED STANDARD SHALL NOT | | | BE USED WITH THESE LOAD COMBINATIONS | | | EXCEPT THAT A DURATION OF LOAD INCREASE | | | SHALL BE PERMITTED IN ACCORDANCE WITH | | | CHAPTER 23. REVISE THE CONNECTOR | | | SCHEDULE ON S3 ACCORDINGLY. SEE NOTES ON | | | THE PLAN. | | | | | | 18) UPDATE THE USP HC 10/10-2 WHICH ARE | | | NO LONGER LISTED IN THE USP CATALOG. | | | | | | 19) SPECIFY THE WELD TYPES AND UPLIFT | | | CAPACITIES FOR THE STEEL COLUMNS ON S4. | | | | | | 20) CORRECT THE HEIGHT AND EXPOSURE | | | COEFFICIENT VALUES IN TABLE 1606.2D ON | | | S4. SEE MARKS ON THE PLAN. | | | | | | 21) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SUBMIT | | | PRODUCT APPROVALS FOR THE FOLLOWING: | | | - ONE HOUR FIRE RATED GLASS BLOCK | | | - SINGLE HUNG WINDOWS | | | - FIXED GLASS WINDOWS | | | - ARCHED TOP WINDOWS | | | - MULLIONS | | | - OVERHEAD GARAGE DOORS | | | - DOUBLE INSWING ENTRY DOORS | | | - PANEL DOORS | | | - SLIDING GLASS DOORS | | | - TRUSS CONNECTORS | | | - STORM PANELS | | | | | | 22) IN ADDITION TO THE PRODUCT APPROVALS | | | FOR THE STORM PANELS, SUBMIT KEY PLANS | | | AND AN INSTALLATION SCHEDULE. SPECIFY | | | THE MOUNT TYPE AND FASTNER TYPE & | | | SPACINGS THAT WILL BE USED. THIS INFO | | | IS REQUIRED PRIOR TO ISSUANCE OF THIS | | | PERMIT OR A SEPARATE PERMIT AND FEES | | | WILL BE REQUIRED. | | | | | | NOTE: NO BUTT GLASS OR STOREFRONTS ARE | | | INDICATED ON THE PLANS. PLEASE REMOVE | | | THESE PRODUCT APPROVALS FORM SUBMITTAL. | | | | | | 23) THERE WAS NO ROOFING CONTRACTOR | | | SIGNED ON THE PERMIT APPLICATION WHEN IT | | | WAS SUBMITTED. THEREFORE, A SEPARATE | | | PERMIT AND FEES WILL BE REQUIRED. | | | PRODUCT APPROVALS WILL BE REQUIRED AT | | | THAT TIME. PLEASE REMOVE THE PRODUCT | | | APPROVALS FOR THE ROOF TILES FROM THIS | | | SUBMITTAL. | | | | | | IN ORDER TO AID PLAN REVIEW TIME, PLEASE | | | SUBMIT OLD PLAN SHEETS THAT HAVE BEEN | | | REMOVED AND REPLACED BY REVISED SHEETS. | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-21 |
Time |
10:17 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-21 |
Time |
10:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-08 |
Time |
17:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-08 |
Time |
17:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-07 |
Time |
14:23 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-07 |
Time |
14:16 |
Sent To |
PC |
|
| Notes |
| 2005-06-07 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} SMOKE DETECTORS ARE REQUIRED PER | | | 905.2.2 FBC, 8-1.4.1.6.2 NFPA-72. | | | | | | 2} FRONT AND REAR GFI RECEPTACLES ARE | | | REQUIRED PER 210.8(A)(3, 210.52(E). | | | | | | 3} THE DISCONNECTS FOFR THE CONDENSING | | | UNITS MOVED FROM THE REVIEWED PLAN AND | | | ARE NOW IN VIOLATION OF 110.26. | | | | | | 4} MICROWAVE IN LOAD CALCS NOT ON PANEL | | | SCHEDULE. PLEASE CORRELATE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-11 |
Time |
12:03 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-05-11 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2005-05-11 00:00:00 | **** REVISIONUNSAT ***** | | | | | | 1)NOTE: PLEASE SEE 210.52C1 AND 210.52C3 | | | FOR MISSING GFI RECEPTS ALONG KITCHEN | | | COUNTERSPACE AND PENINSULAR. | | | PLEASE ALSO SEE 210.8A6 | | | | | | 2)NOTE: PLEASE SEE RECEPTS SHOWN W/IN | | | 6'IF WET BAR SINK REQUIRED TO BE GFI. | | | 210.8A3 | | | | | | 3)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPT ALONG WALL SPACE. PLEASE SEE IF | | | THIS AREA IS CONSIDERED A "HALLWAY" THEN | | | RECEPT WILL NOT BE REQUIRED. | | | | | | 4)NOTE: PLEASE CORRELATE LOAD | | | CALCULATIONS AND PANEL SCHEDULES. | | | PLEASE SEE MICROWAVE SHOWN ON LOAD | | | CALCS, BUT NOT ON PANEL SCHEDULE. | | | PLEASE SEE LOAD/AMPS FOR FRIG AND | | | DISHWASHER BOTH SHOWN AT 19A'S??PLEASE | | | SEE MAX LOAD ON A 20A BRANCH CIRCUIT IS | | | 16A'SHOWEVER THESE DO NOT CORRELATE WITH | | | LOAD CALCULATIONS WHICH SHOWS A MUCH | | | LESSER LOAD. | | | 240.24,310.16,210.11 ETC. | | | | | | 5)NOTE: PLEASE SEE CONNECTED AMPS FOR | | | DRYER IS SHOWN AT 40A'S, HOWEVER CIRCUIT | | | SHOWN IS 30A'S AND KW LOAD ON LOAD | | | CALCS, ONLY INDICATE 5KW?? | | | PLEASE CORRLEATE. | | | 240,215.5,310.16 ETC. | | | | | | 6 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 7)NOTE: PLEASE VERIFY POOL PUMP MOTOR | | | SIZE. PANEL SCHEDULE SHOWS #8AWG, 40A | | | OCP FOR 1HP MOTOR?? | | | PLEASE ALSO CORRELATE WITH LOAD CALCS. | | | | | | 8)NOTE: PLEASE INCLUDE LOAD ON SUB PANEL | | | "B". 215.5 220 | | | | | | PLEASE SEE ONE SET OF PLANS HAS ABOVE | | | ITEMS REDLINED AT AREAS OF NOTES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-28 |
Time |
16:25 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-04-28 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-21 |
Time |
18:19 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-04-21 |
Time |
17:59 |
Sent To |
P |
|
| Notes |
| 2004-04-21 00:00:00 | *************UNSAT 4TH REVIEW ****** | | | | | | 1)NOTE: PLEASE SEE 4X FEE WAS DUE ON | | | LAST PLAN REVIEW DUE TO THREE REVIEWS | | | WITH SAME COMMENTS. NOTICE WAS GIVEN IN | | | NOTES ON 2ND AND 3RD REVIEW FOR THIS | | | UNDER FS 553.80(2)(B). A COPY OF THE FS | | | WAS ALSO ATTACHED TO NOTES. | | | PLEASE SEE BZ #240163 IN THE AMOUNT OF | | | $4032.00 WAS DUE BEFORE RESUBMITTING | | | ON 4/20. BZ IS NOW ATTACHED. | | | PLEASE ALSO SEE NOTES BELOW THAT HAVE | | | STILL HAVE NOT BEEN ADDRESSED FROM | | | FIRST 3 REVIEWS AND NOW THE 4TH REVIEW. | | | PER FS 553.80(2)(B), A 4X FEE IS ACCESS- | | | ED FOR EACH ONE REVIEW IF ANY OF THE | | | SAME COMMENTS ARE NOT ADDRESSED FOR CODE | | | COMPLIANCE. | | | PLEASE SEE ADDITIONAL BZ ATTACHED FOR | | | THIS 4XFEE REVIEW.BZ#240164 WHICH MUST | | | BE PAID BEFORE SUBMITTING PLANS. | | | PLANS WILL NOT BE PERMITTED TO BE RE- | | | -SUBBED UNTIL FEES ARE PAID. PER FS. | | | PLEASE NOTE: IF PLANS COME BACK FOR 5TH | | | REVIEW AND ANY OF THE SAME COMMENTS FROM | | | FIRST FOUR REVIEWS ARE NOT ADDRESSED. | | | WE WILL BE REQ'D TO TURN PLANS INTO | | | DBPR/ BOARD OF ARCH'S FOR REVIEW PER | | | BLDG OFFICIAL. | | | ONE SET OF EACH PLAN IS NOW BEING | | | RETAINED FOR FILE. | | | PLEASE SEE COMMENTS BELOW FROM PREVIOUS | | | REVIEW THAT STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE RISER, STILL SHOWS | | | AN EQUIPMENT GROUNDING CONDUCTOR BEING | | | INSTALLED BETWEEN METER AND FIRST MEANS | | | OF DISCONNECT. PLEASE REMOVE PER 250.6 | | | 250.24. | | | | | | 2)NOTE: PLEASE SEE RECEPT SPACING ON | | | KITCHEN COUNTERSPACE PER 210.52C1 | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 4)NOTE: PLEASE SEE OCP SHOWN FOR OVENS/ | | | COOKTOP ETC. STILL BEING SHOWN AS 1-POLE | | | BRKRS. PLEASE SEE OTHER 220V UNITS. | | | | | | 5)NOTE:PLEASE SHOW LOAD CALCULATIONS | | | FOR A RESIDENTIAL DWELLING AS SETFORTH | | | IN 2002 NEC. 220. 215.5 | | | | | | 6)NOTE: PLEASE INCLUDE REQ'D LICENSE # | | | ON TITLE BLOCK. REQ'D PER FAC 61G1-16.- | | | 004. PLEASE SEE FS 481.219 FOR REQ'D | | | CERTIFICATE OF AUTHIRIZATION #. | | | THIS IS REQ'D | | | | | | 7)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | | SYSTEM PER 250.50, SIZE PER 250.66 | | | | | | NEW COMMENT: | | | PLANS HAVE HAD CHANGES TO THEM TO MEET | | | NEC 210.12.HOWEVER, ALL THESE ARTS | | | ARE REFERENCING THE FBC? PLEASE CORRECT. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. MY # AND E-MAIL ADDRESS | | | WAS PRINTED AND GIVEN ON PREVIOUS | | | REVIEWS AS WELL AS BILL TROBAUGH. | | | AS OF TODAY I HAVE NOT RECEIVED ANY | | | CALLS FOR ANY QUESTIONS ON THE ABOVE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
12:34 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-04-08 |
Time |
12:18 |
Sent To |
B |
|
| Notes |
| 2004-04-08 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW.ALSO NOTE THAT THESE COMMENTS | | | ARE FROM THE FIRST TWO REVIEWS AND WERE | | | NOT ADDRESSED. THE DESIGN PROFESSIONAL | | | IS THEREFORE RESPONSIBLE FOR THE FEES | | | IMPOSSED UNDER FS. 553.80(2)(B), | | | ATTACHED. | | | | | | 1} THE EQUIPMENT GROUNDING CONDUCTOR IN | | | THE FEEDER TO THE FIRST MEANS OF | | | DISCONNECT IS IN VIOLATION OF 250.24 & | | | 250.6. | | | | | | 2} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALL-ED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BERATED FOR THE AVAILABLE FAULT | | | CURRENT PER110.9,110.10 & 215.5. | | | | | | 3} THERE ARE STILL RECEPTACLES MISSING | | | FROM THE KITCHEN COUNTERTOPS PER | | | 210.52(C)(1). | | | | | | 4} NOTE #9 INDICATES MINIMUM WIRE SIZE | | | @ #12 AWG, THE PANEL SCHEDULES LISTS #14 | | | BEING USED ON SEVERAL CIRCUITS. PLEASE | | | CORRELATE. | | | | | | 5} THERE IS NO RECEPTACLE AT THE FRONT | | | OF THE RESIDENCE, VIOLATION OF | | | 210.52(E). | | | | | | 6} THE GROUNDING ELECTRODE SYSTEM MUST | | | COMPLY WITH 250.50 ALL THAT APPLY, | | | INCLUDE BUILDING STEEL. | | | | | | 7} SHOW THE LOCATION OF THE SERVICE | | | EQUIPMENT ON THE PLAN, INCLUDING METER | | | AND MAIN DISCONNECT. | | | | | | 8} VERIFY THE OCP FOR THE COOKTOP AND | | | WALL OVEN. SEE NOTE #9, COMMENTS. | | | | | | 9} SHOW LOADS IN CALCLATION PER ARTICLE | | | 220 NEC. INDICATE METHOD (ARTICLE) USED. | | | | | | 10} RECEPTACLES ARE STILL MISSING IN THE | | | BREAKFAST ROOM AND BEDROOM #3 IN | | | VIOLATION OF 210.52(A)(2). | | | | | | 11} THERE ARE 2 ROOMS DESIGNATED BEDROOM | | | #3. PLEASE CORRELATE WITH ARCHITECTURAL | | | PLANS. | | | | | | 12} THE RECEPTALE IN THE BAR MUST BE GFI | | | PROTECTED PER 210.8(A)(7). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-02-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
14:42 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-02-13 |
Time |
15:30 |
Sent To |
P |
|
| Notes |
| 2004-02-13 00:00:00 | ************* UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE ALL NOTES FROM FIRST | | | REVIEW. PLEASEE SEE THAT NO NOTES WERE | | | ADDRESSED FOR NOTES??? | | | PLEASE SEE COPY OF FS 553.80(2)(B) WITH | | | RESPECT TO DESIGN PROFESSIONAL. | | | PLEASE ADDRESS ALL COMMENTS. | | | | | | 2)NOTE: PLEASE SEE FAC 61G1-16.004, | | | TITLE BLOCK IS REQ'D TO INCLUDE ALL | | | INFORMATION SET FORTH. | | | PER FS 481 | | | PLEASE SEE THAT PLANS ARE REQ'D TO BE | | | SIGNED WITH A COMPLETE SIGNATURE AS | | | REQ'D UNDER FS 481.221. PER FS, INITIALS | | | ARE NOT PERMITTED. PLEASE SEE SOME | | | SHEETS ARE SIGNED WITH COMPLETE SIGNAT- | | | -URE AS REQ'D AND SOME ARETHE INITIALS | | | T.E.D. PLEASE KNOW, WE HAVE BEEN | | | NOTIFIED BY THE STATE THIS IS REQ'D. | | | PLEASE SEE THE ABOVE IS REQ'D FOR ALL | | | SHEETS WEATHER OR NOT COMMENT IS MADE | | | BY OTHER REVIEWERS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
14:43 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-12-30 |
Time |
14:00 |
Sent To |
M |
|
| Notes |
| 2003-12-30 00:00:00 | ************ UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE THAT AN EQUIPMENT | | | GROUNDING CONDUCTOR IS NOT INSTALLED | | | BETWEEN METER AND FIRST MEANS OF DISC. | | | 250.24. PLEASE REMOVE. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATING FOR ALL | | | SERVICE EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS AND BRKRS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FUALT CURRENT. | | | PER 110.9/ 215.5 | | | IT IS NOTED THAT AIC RATING IS NOTED | | | FOR BRANCH BRKRS IN PANELS. | | | | | | 3)NOTE: PLEASE SEE MISSING RECEPTS FOR | | | KITCHEN COUNTERSPACE PER 210.52C1 | | | | | | 4)NOTE: PLEASE SHOW LOAD CALCULATIONS | | | WITH MIN LOADS REQ'D AS SETFORTH IN ART | | | 220 OF THE NEC. | | | | | | 5)NOTE: PLEASE SEE NOTE #9, MENTIONS | | | MIN AWG TO BE #12, PANEL SCHEDULE DOES | | | NOT CORRELATE WITH THIS. PLEASE | | | CORRELATE. | | | | | | 6)NOTE: PLEASE LIST ALL THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS PER 210.12 | | | 2002 NEC. | | | | | | 7)NOTE: PLEASE CORRELATE FEEDERS FOR | | | SUB PANEL 'B'. RISER SHOWS #3/0'S AND | | | PANEL "A" SHOWS #3. | | | | | | 8)NOTE: PLEASE SEE 210.52E FOR FRONT | | | AND REAR RECEPTS. MISSING FRONT. | | | | | | 9)NOTE: PLEASE INCLUDE FOOTER STEEL, | | | COLD WATER PER 250.50 ON RISER DIAGRAM | | | FOR GROUNDING ELECTRODE SYSTEM. | | | | | | 10)NOTE: PLEASE SEE MISSING RECEPT ON | | | 2' OF WALL MASTER BR. 210.52 | | | | | | 11)NOTE: PLEASE SHOW SERVICE ON PLANS/ | | | LOCATION OF METER AND MAIN. | | | | | | 12)NOTE: PLEASE VERIFY OCP FOR BOTH | | | COOKTOP AND WALL OVEN. SHOWN AS 60A?? | | | PLEASE SEE THAT THIS IS NOT A COMMON | | | SIZE, PLEASE VERIFY. | | | | | | 13)NOTE: PLEASE SEE 220.16B FOR MIN KVA | | | OF WASHER/LAUNDRY CIRCUIT. SHOWN WITH | | | LOAD @ 10A'S??. PLEASE SEE NOTE #4 | | | | | | 14)NOTE: PLEASE SEE MISSING RECEPTS | | | IN BR#3 AND BRKFST AREA PER 210.52 | | | PLEASE ALSO SEE RECEPT SPACING IN DINING | | | RM AND ANY OTHER AREAS. DINING RM HAS | | | RECEPT IN CENTER OF DOORWAY (MISPRINT). | | | | | | 15)NOTE: PLEASE SEE THAT THERE ARE TWO | | | ROOMS SHOWN AS BEDROOM #3. PLEASE ADJUST | | | | | | 16)NOTE: PLEASE SEE 210.8 FOR GFI | | | PROETCTION REQ'D IN BAR AREA. LOCAL | | | AMENDMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-16 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-16 |
Time |
14:04 |
Sent To |
E |
|
| Notes |
| 2005-06-16 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2005-06-08 00:00:00 | TO 'BT' DESK./REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-05-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-25 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-25 |
Time |
14:03 |
Sent To |
E |
|
| Notes |
| 2005-05-25 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-09 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-09 |
Time |
15:36 |
Sent To |
E |
|
| Notes |
| 2005-05-09 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-07 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-07 |
Time |
09:07 |
Sent To |
B |
|
| Notes |
| 2005-02-07 00:00:00 | TO R.MCDOUGA DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
| 2004-06-11 00:00:00 | TO RM DESK/REV/INSULATION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-20 |
Time |
12:34 |
Sent To |
E |
|
| Notes |
| 2004-04-20 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-30 |
Time |
14:42 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
14:43 |
Sent To |
E |
|
| Notes |
| 2004-02-11 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2003-12-17 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2003-12-22 00:00:00 | TO SFD RACK/E | | 2003-12-17 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-02-18 |
Time |
09:23 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-02-23 |
Time |
11:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-30 |
Time |
14:38 |
Rev Time |
0.75 |
| Received By |
hmoser |
Date |
2003-12-30 |
Time |
17:35 |
Sent To |
P |
|
| Notes |
| 2003-12-30 00:00:00 | PASS PRIVISO | | | NEED RETURNAIR IN DEN/STUDY | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-06-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-06-25 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-06-25 |
Time |
10:45 |
Sent To |
PC |
|
| Notes |
| 2005-06-25 00:00:00 | REVISION: | | | ADDED BIDET TO ISOMETRIC.PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-08 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-04-28 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-21 |
Time |
18:32 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-02-18 |
Time |
09:23 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-12-30 |
Time |
17:36 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-01-03 |
Time |
06:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-28 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-28 |
Time |
15:15 |
Sent To |
B |
|
| Notes |
| 2004-04-28 00:00:00 | APPROVED REVISION.GIVEN TO ROBERT M |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-19 |
Time |
15:06 |
Sent To |
I |
|
| Notes |
|
|