| Plan Review Stops For Permit 03120833 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-07-22 |
Time |
08:35 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-07-22 |
Time |
08:35 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-16 |
Time |
16:20 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-06-08 |
Time |
16:22 |
Sent To |
PC |
|
| Notes |
| 2004-06-08 00:00:00 | REVISION# 1 5/25/04JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
15:40 |
Rev Time |
0.76 |
| Received By |
jwitmer |
Date |
2004-05-10 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-27 |
Time |
08:13 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2004-04-27 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2004-04-27 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03120833 | | | ADD: 314 CLEMATIS ST | | | CONT:SHAWE-AGER CONSTRUCTION | | | TEL: (561)248-6411 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT# 1 FROM FIRST REVIEW: | | | SHEET A2.1 SHOWS THE RECONFIGURATION OF | | | THE FRONT ENTRY STAIR. | | | 1006.1.1 EXIT STAIRWAYS BETWEEN FLOORS | | | SHALL BE ENCLOSED IN OR SEPERATED BY | | | FIRE RESISTANCE CONSTRUCTION IN ACCORD- | | | ANCE WITH 705.2AND TABLE 705.1.2. | | | | | | THE ISSUE NOT BEING ADDRESSED ON THE | | | FRONT EXIT STAIRWAY FROM PREVIOUS | | | REVIEWS IS THERE ARE (2) REQUIRED MEANS | | | OF EGRESS, THE STAIRWAY SHAFT OR STAIR | | | ENCLOSURE,(EXIT) 1006.1.4 THERE SHALL | | | BENO ENCLOSED USABLE SPACE WITHIN AN | | | EXIT ENCLOSURE. 1006.1.3 A STAIRWELL | | | ENCLOS- URE SHALL NOT BE USED FOR ANY | | | OTHER PUR-POSE OTHER THAN A MEANS OF | | | EGRESS. | | | OPENINGS IN EXIT ENCLOSURES OTHER THAN | | | UNEXPOSED EXTERIOR OPENINGS SHALL BE | | | LIMITED TO THOSE NECESSARY FOR THE EXIT | | | ACCESS TO THE ENCLOSURE FROM NORMALLY | | | OCCUPIABLE OR HABITABLE ROOMS AND FOR | | | EGRESS FROM THE ENCLOSURE. | | | | | | 2) COMMENT# 4 FROM 1ST REVIEW: | | | PRIVATE BATHROOMS, 11-4.1.3(11) PRIVATE | | | BATHROOMS ARE TO BE ADAPTABLE. THIS | | | WILL MEAN TO BE ADAPTABLE THE 5'-0" | | | TURNING RADIUS IS IN AFFECT, BATHROOM | | | 235 APPEARS TO MAKE THIS REQUIREMENT | | | INDICATE THE 5'-0" CLEAR TURNING RADIUS | | | FOR BATHROOM 210. PROVIDE THE REQUIRED | | | BACKING FOR AN ADAPTABLE BATHROOM | | | (11-4.16.4) BACKING FOR GRAB BARS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-02 |
Time |
08:12 |
Rev Time |
2.66 |
| Received By |
jwitmer |
Date |
2004-03-01 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 03120833 | | | ADD: 314 CLEMATIS ST | | | CONT: RAPP CONSTRUCTION | | | TEL: (561)248-6411 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT# 1 FROM FIRST REVIEW: | | | SHEET A-2.1 SHOWS A RECONFIGURATION OF | | | THE FRONT ENTRY STAIR. THE 2ND FLOOR | | | DEMO SHEET ALSO INDICATES A DOOR | | | REMOVED FROM HALLWAY 228. THIS RECONFIG- | | | URATION WITH RECEPTION AREA ELIMINATES | | | THE 1HR RATING OF THE "STAIRWELL SHAFT". | | | 1006.1.1 EXIT STAIRWAYS BETWEEN FLOORS | | | SHALL BE ENCLOSED IN OR SEPERATED BY | | | FIRE RESISTANT CONSTRUCTION IN ACCORD- | | | ANCE WITH 705.2 AND TABLE 705.1.2. | | | TABLE 705.1.2 REQUIRES A 1HR RATED WALL | | | AND 1 HR OPENING PROTECTIVES. | | | 705.1.3.41HR DOORS ARE TO BE USED IN | | | STAIRWAYS. AVERAGE TEMP RISE DEVELOPED | | | ON THE UNEXPOSED SIDE SHALL NOT EXCEED | | | 450 DEGREES F AT THE END OF 30 MINUTES | | | OF STANDARD FIRE TEST EXPOSURE. | | | TABLE 705.1.3.6 | | | WINDOWS IN SHAFTS, 705.2.3.5 OPENINGS | | | IN SHAFT ENCLOSURES SHALLBE PERMITTED | | | WHEN LIMITED TO THOSE NECESSARY FOR THE | | | PURPOSE OF THE SHAFT. PERMITTED OPENINGS | | | INSHAFT ENCLOSURES SHALL BE PROTECTED | | | WITH OPENING PROTECTIVES HAVING A FIRE | | | RESISTANCE IN ACORDANCE WITH 705.1.2. | | | WINDOWS 1HR SEE TABLE 705.1.3.6 FOR | | | WIRED GLASS PANELS USE 1HR RATING SIZE | | | MAX100 SQ IN, 33"X12". | | | | | | 705.2.2 DOES HAVE AN EXCEPTION TO THE | | | SHAFT ENCLOSURE REQUIREMENT 705.2.2(2) | | | BUT"ALL 6 REQUIREMENTS MUST BE MET", | | | (1) IT IS A PART OF A MEANS OF EGRESS. | | | PLANS ALSO INDICATE THAT (2) MEANS OF | | | EGRESS ARE REQUIRED AS DOES 1004.1.4. | | | THE SECOND ISSUE IS 1006.1.4 THERE | | | SHALL BE NO ENCLOSED USABLE SPACE WITHIN | | | AN EXIT ENCLOSURE. THERE MUST BE SEPERA- | | | TION (1HR) BETWEEN THE ENCLOSED STAIR | | | AND LOBBY OR SITTING ROOM! REVISE INDI- | | | CATING RATED DOORS WINDOWS USAGE AS WELL | | | AS PENETRATIONS INTO AND THROUGH A | | | STAIRWELL ENCLOSURE 1006.1.3.1. | | | | | | 2) NOTE# 3 FROM 1ST REVIEW: | | | CORRECT, RAMPS 6" OR LESS DO NOT NEED TO | | | MEET THE HANDRAIL REGULATIONS BUT THE | | | SLOPE AND LANDING REQUIREMENTS OF: | | | 11.4.8.2 SLOPE & RISE | | | 11.4.8.4(2) LANDINGS **SEE BOTTOM LAND- | | | ING 72"X36" MINIMUM.11-4.3.3 MINIMUM | | | WIDTH OF AN ACCESSIBLE ROUTE IS 36". | | | | | | 3) COMMENT# 4 FROM 1ST REVIEW: | | | PRIVATE BATHROOMS, 11-4.1.3(11) | | | PRIVATE BATHROOMS SHALL BE ADAPTABLE. | | | TO BE ADAPTABLE THE SIZE REGULATIONS ARE | | | IN AFFECT, AND BACKING REQUIRED. THESE | | | REQUIREMENTS AFFECT ROOMS 210 & 235. | | | | | | 4) COMMENT# 7 FROM 1ST REVIEW: | | | WILL NEED TO APPLY FOR VARIANCE TO THE B | | | OARD OF AJUSTMENT & APPEAL FOR VARIANCE | | | TO USE DELUGE CURTIAN. | | | THE VARIANCE SHOULD BE FOR A TYPE V | | | BUILDING 0-3' FROM PROPERTY LINE REQUIR- | | | ING THREE HR WALLS (ZERO % OPENINGS) TO | | | ALLOW OPENINGS AT WHAT PERCENT? THE | | | WATER CURTAIN SHOULD BE DESIGNED AS THE | | | EQUAVALENT FOR A 3HR WALLAS PER NFPA 13 | | | WATER CURTAIN 5-13.4. | | | | | | 5) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) IMPACT FIXED WINDOWS | | | *********IMPORTANT************** | | | *********IMPORTANT************** | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-14 |
Time |
12:51 |
Rev Time |
2.75 |
| Received By |
jwitmer |
Date |
2004-01-14 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03120833 | | | ADD: 314 CLEMATIS ST. | | | CONT: RAPP CONSTRUCTION | | | TEL: (561)248-6411 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST BUILDING REVIW | | | ACTION: DENIED | | | | | | 1) SHEET A-2.1 SHOWS A RECONFIGURATION | | | OF THE FRONT ENTRY STAIR. THE 2ND FLOOR | | | DEMO SHEET ALSO INDICATES A DOOR REMOVED | | | FROM HALLWAY 228. THIS RECONFIGURATION | | | WITH RECEPTION AREA ELIMINATES THE 1 HR | | | RATING OF THE STAIRWELL. | | | 1006.1.3.1 PENETRATIONS INTO AND | | | THROUGH A STAIRWAY ENCLOSURE ASSEMBLY | | | ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, DUCTWORK AND EQUIPMENT NECESSARY | | | FOR THE INDEPENDENT STAIR PRESSURIZATION | | | SPRINKLER PIPING, STANDPIPES AND ELECTRI | | | CALCONDUIT SERVING THE STAIRWAY AND | | | TERMINATING AT A STEEL BOX NOT EXCEEDING | | | 16 SQ IN. SUCH PENETRATIONS SHALL BE PRO | | | TECTED IN ACCORDANCE WITH 705.4 | | | 1006.1.4 THERE SHALL BE NO ENCLOSED | | | USEABLE SPACE WITHIN AN EXIT ENCLOSUE, | | | INCLUDING UNDER STAIRS. | | | | | | 2)1012.1.2 EGRESS DOORS SHALL BE SIDE | | | SWINGING TYPE. DOORS SHALL SWING IN THE | | | DIRECTION OF EGRESS FOR THE FOLLOWING: | | | DOUBLE DOORS LEADING TO THE REAR EXIT | | | STAIRS. | | | | | | 3) SERVER ROOM 216: RAMP, | | | 11-4.8.2 SLOPE & RISE. THE LEAST | | | POSSIBLE SLOPE SHALL BE USED FOR ANY | | | RAMP. THE MAXIMUM SLOPE FOR A RAMP IN | | | NEW CONSTRUCTION SHALL BE 1 TO 12. THE | | | MAXIMUM RISE FOR RUN SHALL BE 30" (SEE | | | FIGURE 16). | | | 11-4.8.4.(2) LANDINGS. ALL LANDINGS | | | ON RAMPS SHALL NOT BE LESS THAN 60" | | | CLEAR, & THE BOTTOM OF EACH RAMP SHALL | | | HAVE NOT LESS THAN 72" OF STRAIGHT & | | | LEVEL CLEARENCE. | | | 11.4.8.5. HANDRAILS: IF A RAMP HAS | | | A RISE GREATER THAN 6" OR A HORIZONTAL | | | PROJECTION GREATER THAN 72", THEN IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 4) PRIVATE BATHROOM 210, INSWING DOOR: | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 5) THE DOORSCHEDULE DOESN"T INDICATE | | | THE RATED DOORS FOR EXIT ACCESS COORIDOR | | | OR EXITS. TABLE 705.1.2 | | | | | | 6) THE 1/4" DIAMOND WIRE GLASS, PROVIDE | | | RATING ON THE GLAZING AND FRAME.SEE | | | TABLE 705.1.3.6/ SEC 705.1.3.6.2. | | | SEE A-5.1 DETAIL "03", SIZE LIMITATION | | | OF 54" VERTICAL TABLE 705.1.3.6. | | | | | | 7) SHEET A2.1 NOTE# 7 NEW WINDOWS AND | | | DELUGE CURTAIN. | | | 705.1.1.2 EVERY EXTERIOR WALL WITHIN | | | 15 FT. OF THE PROPERTY LINE SHALL BE | | | EQUIPPED WITH OPENING PROTECTIVES. THE | | | DELUGE SYSTEM WILL REQUIRE GOING TO THE | | | BOARD OF ADJUSTMENT & APPEAL FOR A VAR- | | | IANCE UNDER ALTERNATE MEANS AND METHODS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
P |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-10 |
Time |
09:12 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-10 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-21 |
Time |
08:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-01-21 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-08 |
Time |
13:40 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-08 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-08 |
Time |
08:15 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-10-08 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2004-10-08 00:00:00 | ********* UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE TITLE BLOCK TO BE | | | REVISED TO CORRELATE WITH NAME ON RECORD | | | WITH STATE. APPEARS TO BE A MISPRINT | | | FROM AN OLD CAD? | | | | | | ELECTRICAL OK, NO NEED FOR ELECTRICAL | | | CORRECTIONS. | | | STAMPED IN ERROR AND VOIDED ELECTRICAL | | | SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-06 |
Time |
14:52 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-09-14 |
Time |
20:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
N |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-16 |
Time |
20:11 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-16 |
Time |
20:10 |
Sent To |
|
|
| Notes |
| 2004-09-16 00:00:00 | REV FOR FIRE ALARM. N/A | | | NEEDS TO BE UNDER FA PERMIT. 04060806 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-25 |
Time |
15:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-03 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
11:19 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2004-05-08 00:00:00 | *** REVISED E-2 ONLY** | | | SHEET E-4 IS STILL REDLINED PER NEC | | | 230.76,230.79, 230.72, 110.27 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-17 |
Time |
13:20 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-17 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2004-04-17 00:00:00 | REVISED SHEETS E-1, E-2 ONLY. | | | E-4 STILL REDLINED FOR 230.72,230.76, | | | 230.79, 110.27. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-02 |
Time |
07:56 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-02-02 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2004-02-02 00:00:00 | **** REDLINED NOTES *** | | | | | | ATS, REQ'D TO HAVE A MEANS OF DISC TO | | | MEET 230.76,230.79 AND 110.27. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-02 |
Time |
10:00 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-12-29 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | *************** UNSAT *************** | | | | | | 1)NOTE: PLEASE PROVIDE MORE INFORMATION | | | ON GENERATOR. | | | PLEASE PROVIDE MEANS OF DISC PER 230.72 | | | 230.76,230.79. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATING FOR | | | NEW SERVICE MAIN. SHOWN FOR PANELS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-09-20 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-09-20 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2004-09-20 00:00:00 | REVISION SHOULD BE UNDER FIRE ALARM | | | PERMIT 04060806 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-11 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-11 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | PREVIOUSLY APPROVED BY FIRE RESCUE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-06 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-06 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2004-04-06 00:00:00 | 1) ENSURE THAT EMERGENCY LIGHTING | | | EQUIPMENT IS PRESENT IN THE STAIRWAYS. | | | | | | 2) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR FIRE SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-01-29 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-01-29 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-02 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-02 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) PLEASE PROVIDE MORE DETAILS FOR | | | NEW EMERGENCY GENERATOR PLANNED FOR | | | THE ROOF. | | | | | | 3) PLEASE PROVIDE MORE DETAILS ON | | | DELUGE FIRE SPRINKLER HEADS, ITEM # 18 | | | ON PAGE A.1. | | | | | | 4) THE DOUBLE DOORS FOR THE EXISTING | | | EGRESS STAIR VESTIBULE APPEARS TO | | | SWING IN THE WRONG DIRECTION. SHOULD | | | THEY NOT SWING IN THE DIRECTION OF | | | EXIT TRAVEL. | | | | | | 5) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FM 200 RELOCATION FROM EXISTING | | | LOCATION TO THE NEW LOCATION. | | | | | | 6) PLEASE EXPLAIN WHY STAIR NEAR | | | WAITING 200 IS NOT SEPARATED FROM ALL | | | PORTIONS OF THE BUILDING. | | | | | | 7) TACTILE SIGNAGE IS REQUIRED AT | | | STAIRWAYS. | | | | | | 8) ALL SHAFTWAYS THAT ARE LARGE ENOUGH | | | FOR PERSONS TO FALL INTO MUST BE | | | MARKED SHAFTWAY WITH 6" HIGH LETTERS. | | | | | | 9) DOOR FROM RECEPTION 241 MAY SWING | | | TOO FAR INTO CORRIDOR. | | | | | | 10) PLEASE PROVIDE PRODUCT APPROVALS | | | FOR DIAMOND WIRE GLASS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-07 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-07 |
Time |
09:36 |
Sent To |
E |
|
| Notes |
| 2005-02-07 00:00:00 | TO DPALMER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:23 |
Sent To |
E |
|
| Notes |
| 2004-10-05 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-31 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-31 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2004-08-31 00:00:00 | TO COMM BD#20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-25 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-25 |
Time |
15:52 |
Sent To |
E |
|
| Notes |
| 2004-08-25 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
09:12 |
Sent To |
M |
|
| Notes |
| 2004-08-16 00:00:00 | TO PK DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-26 |
Time |
11:19 |
Sent To |
E |
|
| Notes |
| 2004-07-26 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-26 |
Time |
11:07 |
Sent To |
M |
|
| Notes |
| 2004-07-26 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-16 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-16 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2004-07-16 00:00:00 | TO JW DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-07-14 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-07-14 |
Time |
12:30 |
Sent To |
B |
|
| Notes |
| 2004-07-14 00:00:00 | SENT TO JW DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
15:40 |
Sent To |
B |
|
| Notes |
| 2004-06-03 00:00:00 | TO JW DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | TO COMM BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-02 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-05 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2004-04-02 00:00:00 | TO COMM BD#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-28 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-28 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-16 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | TO COMM BD#15 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-24 |
Time |
13:01 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-08-24 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
09:12 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-08-04 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
11:07 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-12 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2004-05-12 00:00:00 | PROVISO: | | | PLAN SHEET M-1 INDICATES A FLEX DUCT | | | PENETRATING A FIRE RESISTANCE RATED | | | ASSEMBLY.PER 2001 603.5.5 FLEXIBLE | | | DUCTS ARE PROHIBITED THROUGH A FIRE | | | RATED ASSEMBLY. FIRE DAMPER IS NOT | | | REQUIRED IF IT COMPLIES WITH SECTION | | | 607.1.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-20 |
Time |
11:13 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-04-20 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2004-04-20 00:00:00 | RESUB/CHANGE TO PLAN SHEET M-1 ONLY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-02 |
Time |
09:45 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-02-02 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2004-02-24 00:00:00 | PASSED ON 2-2-04 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-31 |
Time |
14:17 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2003-12-31 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2003-12-31 00:00:00 | DENIED: | | | 1.PLAN SHEET M-1, PLEASE CLARIFY 8 X 8 | | | DUCT IN THE WAITING ROOM 200, IS THIS | | | DUCT RUNNING THROUGH A EGRESS STAIRWAY? | | | | | | 2.PLAN SHEET M-2 EXISTING MECHANICAL | | | ROOM.DOES THIS SPACE HAVE ANY TYPE | | | OF EXISTING VENTILATION? | | | | | | 3.M-2 INDICATES DETAIL FOR A FIRE | | | DAMPER INSTALLATION FOR "WALL TYPE" | | | PLEASE PROVIDE DETAIL FOR THE FIRE | | | DAMPERS INSTALLED IN THE FLOOR. | | | | | | 4.PLAN SHEET M-2 INDICATES NEW | | | EMERGENCY GENERATOR, WILL THIS WORK BE | | | DONE AT THIS TIME OR FUTURE?PLEASE | | | PROVIDE ADDITIONAL INFORMATION.PLEASE | | | PROVIDE MANUFACTURER SUBMITTAL DATA OR | | | CUT SHEETS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-12 |
Time |
18:34 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-05-12 |
Time |
18:34 |
Sent To |
|
|
| Notes |
| 2004-05-12 00:00:00 | SEPARATE GAS PERMIT REQUIRED - FIELD | | | VERIFY BTU'S AND LISTING FOR EXISTING | | | GAS GENERATOR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-12 |
Time |
07:59 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-12 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2004-04-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | | | | 1) SHTS A2.1, A2.2, A2.5 & A5.2 PROVIDE | | | DETAILS FOR ADAPTABILITY FOR ROOMS #210 | | | AND #235. RESPONSE NOTED, BUT DETAILS | | | STILL NEEDED ARE 11-4.16.2 CLEAR FLOOR | | | SPACE, 11-4.16.4 BACKING FOR GRAB BARS, | | | 11-4.19.3 CLEAR FLOOR SPACE, 11-4.21.3 | | | BACKING FOR SEAT, 11-4.21.4 BACKING FOR | | | GRAB BARS, 11-4.21.5 CONTROL LOCATION, | | | 11-4.21.7 CURBS, AND 11-4.23.3 TURNING A | | | AREA. - SEE COMMENT #2 FROM PREVIOUS RE- | | | VIEW | | | 2) THIS IS THE THIRD REJECTION AND A 4 | | | TIMES THE FEE MAY BE APPLIED FOR PLAN | | | REVIEW PER FS 533.80(2)(B). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-05 |
Time |
17:04 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-02-05 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHTS A2.1, A2.2, & A5.2 DETAIL #13. | | | ROOM #235 SHALL BE ACCESSIBLE. PROVIDE | | | DETAIL FOR 11-4.16 W/C'S, (SEE FIGS. 28 | | | & 29), 11-4.19 LAVS, (SEE FIGS. 31, & 32 | | | ), 11-4.21 SHOWERS, (SEE FIGS. 35, 36, & | | | 37), AND 11-4.23 SHOWER ROOMS. ALSO SHOW | | | ALL SUBSECTIONS FOR EACH SECTION. 11-4.3 | | | .1(11) - RESPONSE NOTED, BUT BATHROOM # | | | 235 IS NOT ADJACENT TO OFFICE #208. | | | OFFICES #234 & #236 ARE ADJACENT TO THIS | | | BATHROOM AND ONLY PRIVATE BATHROOMS OF | | | ONE OFFICE SHALL BE ADAPTABLE. | | | 2) SHTS A2.1, A2.2, & A5.2 DETAIL #9. | | | ROOM #210 SHALL BE ADAPTABLE. PROVIDE | | | DETAILS SHOWING BACKING FOR GRAB BARS, | | | CLEAR FLOOR SPACE, TURNING AREA, SHOWER | | | CONTROLS, CURB, BACKING FOR SHOWER GRAB | | | BARS, ECT. SECTIONS 11-4.1.3(11), 11-4.2 | | | 1 (FIGS 35, 36, 37). - RESPONSE NOTED, | | | BUT BATHROOM #210 IS ADJACENT TO OFFICE | | | #208 AND CAN BE ADAPTABLE BUT DETAILS | | | ARE REQUIRED. | | | 3) SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 4) THESE ARE COMMENTS FROM FIRST REVIEW | | | THAT ARE BEING REQUIRED FOR THE SECOND | | | REVIEW. SEE ATTACHED SHEET CONCERNING | | | FS 533.80(2)(B) DESIGN PROFESSIONAL DOC- | | | UMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-06 |
Time |
12:03 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-01-06 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2004-01-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHTS A2.1, A2.2, & A5.2 DETAIL #13. | | | ROOM #235 SHALL BE ACCESSIBLE. PROVIDE | | | DETAIL FOR 11-4.16 WATER CLOSETS, (SEE | | | FIGS. 28 & 29), 11-4.19 LAVS, (SEE FIGS. | | | 31 & 32), 11-4.21 SHOWERS, (SEE FIGS. 35 | | | 36, & 37), AND 11-4.23 SHOWER ROOMS. | | | ALSO SHOW ALL SUBSECTIONS FOR EACH SECT- | | | ION. 11-4.3.1(11). | | | 2) SHTS A2.1, A2.2, & A5.2 DETAIL #9. | | | ROOM #210 SHALL BE ADAPTABLE. PROVIDE | | | DETAIL SHOWING BACKING FOR GRAB BARS, | | | CLEAR FLOOR SPACE, TURNING AREA, LAV | | | HEIGHT, OPENING FOR WATER CLOSET, SHOWER | | | CONTROLS, CURB, BACKING FOR SHOWER GRAB | | | BARS ECT. 11-4.1.3(11). | | | 3) SHTS A2.1, A2.2, & A5.2 DETAIL #11. | | | BREAK ROOM SINK SHALL COMPLY WITH SECT- | | | ION 11-4.24 AND ALL SUBSECTIONS. PROVIDE | | | A DETAIL. | | | 4) SHT P-1 WATER ISOMETRIC AT DRINKING | | | FOUNTAIN. AIR CHAMBERS ARE NOT APPROVED. | | | DELETE FROM DIAGRAM. | | | 5) SHT P-1 SUBMIT WATER & SANITARY ISO- | | | METRICS FOR BREAK ROOM SINK. SECTION | | | 104.3.1.1. WATER HAMMER ARRESTOR REQUIR- | | | ED FOR DISHWASHER. SECTION 604.9 | | | 6) SHT P-1 PLUMBING NOTES: #12 AIR | | | CHAMBERS ARE NOT APPROVED. DELETE REF- | | | ERENCE. | | | 7) SHT P-2 FOLLOWING INFORMATION REQUIR- | | | ED FOR APPLICATION FOR GAS PERMIT. | | | SEPARATE PERMIT REQUIRED FOR GAS. | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | C. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). | | | D. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | | SECS. 502 THRU 506. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|