| Plan Review Stops For Permit 03120697 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-14 |
Time |
09:05 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-01-14 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | RESTAMP OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-05 |
Time |
09:40 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-04-05 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-19 |
Time |
08:28 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-03-19 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2004-03-19 00:00:00 | DENIED | | | 1.NONE OF THE CORRECTIONS HAVE BEEN | | | MADE TO THE 2-18-04 BUILDING PLAN | | | REVIEW.SEE ATTACHED REVIEW. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-18 |
Time |
12:29 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2004-02-18 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2004-02-18 00:00:00 | DENIED | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | | OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | 2.SUBMIT 2 COPIES OF ALL PRODUCT | | | APPROVALS REQUIRED.CARADCO NOT LISTED | | | ON THE FBC PRODUCT APPROVAL SITE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 3.ENERGY CALCULATIONS NOT SIGNED. | | | 4.BUILDING IN IN FLOOD ZONE "A" | | | SUBMIT AN ELEVATION CERTIFICATE. | | | 5.FBC 3401.7.2.6WHEN ALTERATIONS | | | AMOUNTING TO MORE THAN 50% OF THE VALUE | | | OF THE EXISTING BUILDING DURING A 12 | | | MONTH PERIOD, THE BUILDING SHALL BE | | | MADE TO CONFORM TO THE REQUIREMENTS FOR | | | A NEW BUILDING. | | | IMPROVED VALUE 90,498 PROJECT | | | VALUE 97,000 | | | ART LANGE | | | BUIDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-05-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-12 |
Time |
13:33 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-12 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-07 |
Time |
10:01 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-04-07 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2005-04-07 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} ANY REVISIONS MADE TO AN ENGINEERED | | | SET OF WRAWINGS MUST BE MADE BY THE | | | DESIGNER OF RECORD. F.S.471. | | | | | | 2} CU #2 NEEDS A DISCONNECT. | | | | | | 3} 210.63 RECEP @CU EQUIP. | | | | | | 4} COMPLY WITH 210.52(E). | | | | | | 5} COMPLY WITH 905.2.2 FBC RE: SD'S @ | | | STAIRWELLS. | | | | | | 6} 210.52(D) SECOND FLOOR BATH. | | | | | | 7} 905.2.2 2ND FLOOR STAIRS. | | | | | | PLEASE SEE APPROVED PLANS AND CORRELATE | | | WITH REVISIONS BEFORE RESUBMITTING. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2004-04-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-03 |
Time |
07:58 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-04-03 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2004-04-03 00:00:00 | ROUTED TO ELEC IN ERROR./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
09:55 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-17 |
Time |
13:57 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
12:32 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-02-09 |
Time |
12:56 |
Sent To |
P |
|
| Notes |
| 2004-02-09 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE RISER DIAGRAM SHOWS #3/0 FEEDERS | | | TO PANEL "A",THE PANEL SCHEDULE | | | INDICATES #2/0,PLEASE CORRELATE. | | | | | | 2} PLEASE CHECK ELECTRICAL NOTES. #16 | | | SPECS.#12 WIRE,BUT PANEL SCHEDULE SHOWS | | | #14. #37 SHOULD REFER TO 250.66 FOR GEC | | | ART. | | | | | | 3} THE OVERHEAD RISER WOULD APPEAR TO BE | | | IN VIOLATION OF 230.9(A) AND/OR (B).SEE | | | SHEET A-4 ELEVATION. INDICATE | | | COMPLIANCE. | | | | | | 4} PLEASE SEE RECEPTS SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5 | | | | | | 5} PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6',12' RULE.SEVERAL LOCATIONS | | | DO NOT COMPLY, SEE REVIEWED SET. | | | | | | 6} THE CONDENSER DISCONNECTS DO NOT | | | APPEAR TO COMPLY WITH 110.26. | | | | | | 7} SMOKE DETECTORS AT THE STAIRWELLS TO | | | COMPLY WITH 905.2.2 FBC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-05-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-05 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-05 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2005-05-05 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-31 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-31 |
Time |
13:35 |
Sent To |
E |
|
| Notes |
| 2005-03-31 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-10 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-10 |
Time |
12:12 |
Sent To |
B |
|
| Notes |
| 2005-01-10 00:00:00 | TO "AL" DESK/RESTAMP. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
13:42 |
Sent To |
M |
|
| Notes |
| 2004-10-25 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-30 |
Time |
09:55 |
Sent To |
E |
|
| Notes |
| 2004-03-30 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
12:32 |
Sent To |
E |
|
| Notes |
| 2004-03-11 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
10:48 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-03 |
Time |
16:41 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-05 |
Time |
09:03 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-11-05 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
13:43 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-02-11 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-18 |
Time |
12:29 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-03-18 |
Time |
12:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-17 |
Time |
14:13 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-02-09 |
Time |
16:07 |
Sent To |
M |
|
| Notes |
| 2004-02-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-3 SANT. RISER DIAGRAM, MASTER | | | BATH SHOWER SHALL BE MINIMUM OF 2" PIPE | | | TABLE 709.1 | | | 2) SHT P-3 SANT. RISER DIAGRAM, WASH | | | MACHINE REQUIRES A STANDPIPE, AND THE | | | CLEANOUT SHALL BE LOCATED MINIMUM OF 4 | | | FEET ABOVE FLOOR. 406.3 - 708.10 | | | 3) SHT P-3 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED. 604.9 PLEASE | | | DELETE FROM RISER. | | | 4) SHT P-3 WATER HEATER DETAIL, WATER | | | HEATERS INSTALLED ABOVE THE GROUND FLOOR | | | SHALL BE INSTALLED IN A PAN. 804.5 | | | 5) SHT P-3 WATER HEATER DETAIL, THERMAL | | | EXPANSION CONTROL REQUIRED IF THERE IS A | | | RPZ BACKFLOW ON THE WATER SERVICE TO THE | | | RESIDENCE. 607.3.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-05 |
Time |
10:47 |
Sent To |
I |
|
| Notes |
| 2004-02-06 00:00:00 | PER MM STAMPED PLANS/DEE |
|
|