| Plan Review Stops For Permit 03120609 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-23 |
Time |
13:38 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-03-23 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-19 |
Time |
12:14 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-03-22 |
Time |
08:18 |
Sent To |
P |
|
| Notes |
| 2004-03-22 00:00:00 | DENIED | | | | | | 1. FORM 600C REQUIRED.SUBMIT 2 COPIES | | | | | | 2. ORIGONAL PERMIT APPLICATION MISSING | | | INCLUDE WITH PLANS. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
msmith |
Date |
2004-03-09 |
Time |
15:43 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-02-27 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2004-02-27 00:00:00 | DENIED | | | 1.SUTTER PRODUCT APPROVAL MISSING. | | | PREMDOR ENTRY DOOR NOT LISTED ON FBC | | | PRODUCT APPROVAL SITE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 1A.SUBMIT 2 COPIES OF PRODUCT | | | APPROVALS PER WPB AMMENDMENTS TO THE | | | FBC104.2.1 TWO COPIES OF SPECIFICATIONS | | | AND OF DRAWINGS DRAWN TO SCALE WITH | | | SUFFICIENT CLARITY AND DETAIL TO | | | INDICATE THE NATURE OF THE WORK. | | | | | | 2.SUBMIT DRAWING FOR REAR STEPS. | | | DRAWING SHALL COMPLY WITH WPB AMMENDMENT | | | TO THE FBC SECTION 104.2.1.3 QUALITY | | | OF BUILDING PLANS. | | | | | | 3. SUBMIT ENERGY CALCULATIONS. | | | | | | ANY QUESTIONS CONTACT | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-23 |
Time |
13:34 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2004-01-29 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | UNSTAT | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | 2.FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE | | | INSTALLATIONSCHEDULE SUMMARIZING & | | | IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL | | | PRES-SURE ZONES, SLAT TYPES, ETC., | | | SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | 3. SUBMIT PRODUCT APPROVALS FOR WINDOWS | | | EXTERIOR DOORS AND SHUTTERS. | | | 4.NOTE... BATHROOM WINDOWS SHALL | | | COMPLY WITH FBC 2405.2.1 | | | 5.SUBMIT A DETAIL FOR STEPS AT REAR | | | DOOR.THAY SHALL COMPLY WITH FBC | | | 1007.3.1 | | | 7.SUBMIT ENERGY CALCULATIONS AND | | | WINDOW PRESSURES. | | | 8.SHOW DETAIL HOW NEW ADDITION IS | | | BEING ATTACHED TO EXISTING STRUCTURE. | | | 9.FBC 3401.7.2.6 WHEN REPAIRS AND | | | ALTERATIONS ARE MADE DURING ANY 12 | | | MONTH PERIOD EXCEED 50 PERCENT OF THE | | | VALUE OF THE EXISTING BUILDING. | | | STRUCTURE SHALL BE MADE TO CONFORM TO | | | REQUIREMENTS FOR A NEW BUILDING. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
09:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-01-27 |
Time |
16:14 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-19 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-19 |
Time |
12:13 |
Sent To |
B |
|
| Notes |
| 2004-03-19 00:00:00 | TO AL DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
msmith |
Date |
2004-03-09 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
msmith |
Date |
2004-03-09 |
Time |
15:42 |
Sent To |
B |
|
| Notes |
| 2004-03-09 00:00:00 | SENT TO ART LANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-12 |
Time |
15:00 |
Sent To |
P |
|
| Notes |
| 2004-02-12 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-27 |
Time |
09:44 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-23 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-11 |
Time |
16:17 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-22 |
Time |
09:47 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-03-22 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | NO MECHANICAL PLANS SUBMITTED WITH | | | BUILDING PERMIT.PLEASE PROVIDE | | | INFORMATION WITH MECHANICAL PERMIT | | | APPLCIATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-23 |
Time |
13:34 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-02-23 |
Time |
13:27 |
Sent To |
B |
|
| Notes |
| 2004-02-23 00:00:00 | DENIED:2ND REQUEST | | | PER PLAN REVIEW DATED 1-28-04: | | | PROVIDE A COMPLETED FORM 600C AS R | | | REQUIRED PER 2001 FBC CHAPTER 13 SUB | | | CHAPTER 600.NO MECHANICAL PLANS | | | SUBMITTED FOR REVIEW.PLEASE PROVIDE | | | PLANS WITH MECHANICAL PERMIT APPLICATION | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-18 |
Time |
07:32 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-01-28 |
Time |
13:53 |
Sent To |
B |
|
| Notes |
| 2004-01-28 00:00:00 | DENIED: | | | PLEASE PROVIDE A COMPLETED FORM 600C AS | | | REQUIRED PER 2001 FBC CHAPTER 13 SUB | | | CHAPTER 600.NO MECHANICAL PLANS | | | SUBMITTED FOR REVIEW.PLEASE PROVIDE | | | PLANS WITH MECHANICAL PERMIT APPLICATION | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-22 |
Time |
09:57 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-03-22 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | SANITARY RISER DIAGRAM SHALL BE SUBMITT- | | | ED WITH PLUMBING PERMIT. - RISER DIAGRAM | | | SHALL BE SIGNED AND SEALED BY ENGINEER | | | OF RECORD AND SHALL HAVE APPROPRIATE | | | TITLE BLOCK INFORMATION REQUIRED BY FAC | | | 61G15-002(2) AND FS 471.025 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-22 |
Time |
08:50 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-02-18 |
Time |
07:29 |
Sent To |
M |
|
| Notes |
| 2004-02-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | A) COMMENTS FROM PREVIOUS REVIEW HAVE | | | NOT BEEN ADDRESSED. SEE ATTACHED SHEET | | | WITH COMMENTS FROM FIRST REVIEW. | | | B) SEE ATTACHED SHEET CONCERNING FLORIDA | | | STATUTE 533.80(2)(B). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
15:00 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-27 |
Time |
18:21 |
Sent To |
M |
|
| Notes |
| 2004-01-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT N-2 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS, NOR DOES IT | | | REFLECT THE FLOOR PLAN: | | | A) WASH MACHINE REQUIRES A TRAP AND A | | | CLEANOUT. 1002.1 & 708.10 | | | B) TUB NOT VENTED AND W/C SHALL CONNECT | | | DOWNSTREAM OF THE LAV. 901.2.1 AND | | | 104.2.1.1. | | | 2) SEE RED LINE CORRECTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-23 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-23 |
Time |
11:09 |
Sent To |
I |
|
| Notes |
| 2004-01-23 00:00:00 | MUST MEET THE 10FT SEPERATION FOR | | | CURRIE CORRIDOR MIXED USE DISTRIT (CMUD) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-23 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-23 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | DENIED, NEED TO MAKE SURE THEY MEET SIDE | | | SETBACKS OF 10F SEPERATION BETWEEN | | | EXISTING & NEW BUILDING CALLED CONTR | | | LEFT MSG FILE R MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-11 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-16 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | NEED TO PROVIDE 2 COPY OF SURVEY CALLED | | | LEFT MSG MM |
|
|