| Plan Review Stops For Permit 03120591 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-02 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-30 |
Time |
15:08 |
Sent To |
PC |
|
| Notes |
| 2005-08-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03120591 | | | ADD: 533 CLEMATIS ST. | | | CONT: SHAKMAN | | | TEL: (561)239- 9018 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | SUBMITTAL SHOP DRAWINGS REVIEW | | | ACTION: REVIEWED/ PROVISO | | | AUGUST 02/05 | | | 1) PLANS DO NOT INDICATE THE SIZE OF THE | | | FORMED BY THE TRIANGULAR AREA FORMED BY | | | THE TREAD, RISER AND BOTTOM OF GUARD | | | RAIL. 1015.6 (1)A 6 INCH (152 MM) | | | SPHERE SHALL NOT PASS THROUGH THE | | | TRIANGULAR OPENING FORMED BY A TREAD, | | | RISER AND BOTTOM OF A GUARDRAIL. | | | | | | 2) PLANS DO NOT INDICATE HANDRAILS OR | | | EXTENTIONS: 11-4.9.4(2) IF HANDRAILS ARE | | | NOT CONTINUOUS, THEY SHALL EXTEND AT | | | LEAST 12 INCHES (305 MM) BEYOND THE | | | TOP RISER AND AT LEAST 12 INCHES | | | (305 MM) PLUS THE WIDTH OF ONE TREAD | | | BEYOND THE BOTTOM RISER.AT THE | | | TOP, THE EXTENSION SHALL BE PARALLEL | | | WITH THE FLOOR OR GROUND SURFACE. | | | AT THE BOTTOM, THE HANDRAIL SHALL | | | CONTINUE TO SLOPE FOR A DISTANCE OF | | | THE WIDTH OF ONE TREAD FROM THE | | | BOTTOM RISER; THE REMAINDER OF THE | | | EXTENSION SHALL BE HORIZONTAL (SEE | | | FIGURE 11-19(C) AND | | | FIGURE 11-19(D)).HANDRAIL | | | EXTENSIONS SHALL COMPLY WITH 11-4.4. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-22 |
Time |
10:27 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-07-22 |
Time |
10:27 |
Sent To |
PC |
|
| Notes |
| 2005-07-22 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03120591 | | | ADD: 533 CLEMATIS ST. | | | CONT: SHAKMAN | | | TEL: (561)239- 9018 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | SUBMITTAL SHOP DRAWINGS REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS DO NOT INDICATE THE SIZE OF THE | | | FORMED BY THE TRIANGULAR AREA FORMED BY | | | THE TREAD, RISER AND BOTTOM OF GUARD | | | RAIL. 1015.6 (1)A 6 INCH (152 MM) | | | SPHERE SHALL NOT PASS THROUGH THE | | | TRIANGULAR OPENING FORMED BY A TREAD, | | | RISER AND BOTTOM OF A GUARDRAIL. | | | | | | 2) PLANS DO NOT INDICATE HANDRAILS OR | | | EXTENTIONS: 11-4.9.4(2) IF HANDRAILS ARE | | | NOT CONTINUOUS, THEY SHALL EXTEND AT | | | LEAST 12 INCHES (305 MM) BEYOND THE | | | TOP RISER AND AT LEAST 12 INCHES | | | (305 MM) PLUS THE WIDTH OF ONE TREAD | | | BEYOND THE BOTTOM RISER.AT THE | | | TOP, THE EXTENSION SHALL BE PARALLEL | | | WITH THE FLOOR OR GROUND SURFACE. | | | AT THE BOTTOM, THE HANDRAIL SHALL | | | CONTINUE TO SLOPE FOR A DISTANCE OF | | | THE WIDTH OF ONE TREAD FROM THE | | | BOTTOM RISER; THE REMAINDER OF THE | | | EXTENSION SHALL BE HORIZONTAL (SEE | | | FIGURE 11-19(C) AND | | | FIGURE 11-19(D)).HANDRAIL | | | EXTENSIONS SHALL COMPLY WITH 11-4.4. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-27 |
Time |
08:54 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2005-01-27 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-18 |
Time |
08:47 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2005-01-18 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2005-01-18 00:00:00 | 01-18-05 REVISION SUBMIT WINDOW, MULLION | | | & EXTERIOR DOOR REVISIONS PLUS SHEET | | | S-4. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-11-23 |
Time |
08:03 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2004-11-23 |
Time |
08:02 |
Sent To |
PC |
|
| Notes |
| 2004-11-23 00:00:00 | 11-23-04 CERTIFICATION OF CODE | | | COMPLIANCE (WELD CERTIFICATION)JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-10-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-10-22 |
Time |
12:57 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-10-22 |
Time |
12:41 |
Sent To |
PC |
|
| Notes |
| 2004-10-22 00:00:00 | 10-22-04 REV: 9-07-04/ 9-22-04JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-10-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:51 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2004-10-04 |
Time |
13:33 |
Sent To |
PC |
|
| Notes |
| 2004-10-04 00:00:00 | REVISION STOREFRONT ARCH ALUMINIUMJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
14:53 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-08-25 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2004-08-25 00:00:00 | REVISIONS A) LETTER FOR 2X8 FLOOR JOIST | | | B) FOOTER & COLUMN REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-20 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-01-27 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-06-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-19 |
Time |
08:35 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2004-06-19 |
Time |
08:14 |
Sent To |
PC |
|
| Notes |
| 2004-06-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03120591 | | | ADD: 533 CLEMATIS ST | | | CONT: SHAKMAN CONSTRUCTION | | | TEL: (561)756-0540 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | NOTE: THIS REVIEW IS THE RESULTS OF A | | | MEETING WITH SHERRY PILAND/ NEIL MELICK | | | AS TO WHAT PARTS OF THE BUILDING WILL | | | FALL UNDER THE HISTORIC PERVIEW AND | | | WHAT | | | PARTS WILL FALL UNDER BUILDING FOR | | | REVIEW. | | | | | | 1) COMMENT# 4 FROM PREVIOUS REVIEW: | | | 903.8.1 BUILDINGS 3 STORIES OR MORE. | | | ANY | | | BUILDING 3 STORIES SHAL BE EQUIPPED | | | WITH | | | AN APPROVED AUTOMATIC FIRE SPRINKLER | | | SYSTEM INSTALLED IN ACCORDANCE WITH | | | 903.1 | | | RESPONCE: EXISTING SYSTEM, GC TO SUBMIT | | | FIRE SPRINKLER DRAWINGS AS PART OF THIS | | | SUBMITTAL. | | | NO FIRE SPRINKLER PLANS WERE SUBMITTED! | | | | | | 2) COMMENT# 14 FROM PREVIOUS REVIEW: | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: STOREFRONT SYSTEM | | | RESPONCE: GC SHALL SUBMIT THE TEST | | | REPORTS REQUIRED FOR THESES ITEMS. | | | NO PRODUCT TESTING REPORTS SUBMITTED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3) COMMENT #20 FROM PREVIOUS REVIEW | | | DEALS WITH REINFORCED AREAS FOR | | | ADAPTABLE BATHROOMS THERE IS NO | | | INFORMA- | | | TION FOR BACKING FOR THE SHOWER, TAKEN | | | FROM FLORIDA ACCESSIBILITY CODE AND THE | | | FAIR HOUSING CODE. | | | | | | 4) COMMENT #21 FROM PREVIOUS REVIEW: | | | DEALS WITH THE FIRST FLOOR ENTRY DOORS. | | | SHEET A-0 INDICATES THAT THERE IS A | | | 2'-6" SET BACK, SHEET A2.1 INDICAES A | | | PAIR OF 3'-0" OVERHANGING INTO THE | | | RIGHT OF WAY 6". | | | | | | 5) GUIDELINES FOR REHABILITING HISTORIC | | | BUILDINGS, FLORIDA BUILDING CODE,APPX. | | | D | | | THE SAME MEETING BETWEEN NEIL MELICK, | | | SHERRY PILAND AND MYSELF, IT WAS | | | DISCUSS | | | ED THAT THE WINDOWS WOULD NOT BE | | | REPLACED, HISTORIC RECOMMENDATIONS. THE | | | TOPIC OF ENERGY RETROFITTING WAS | | | DISCUSS | | | ED. SINCE THE WINDOWS WERE NOT TO BE | | | RE- | | | PLACED IT WAS DETERMINED TO HELP MAKE | | | THE BUILDING MORE ENERGY EFFICIENT AND | | | WORK ING WITH THE EXISTING WINDOWS, TO | | | IMPROVE THERMAL EFFICIENCY WITH | | | WEATHER- | | | STRIPPING, CAULKING, INTERIOR SHADES, | | | AND IF HISTORICLLY APPROPRIATE, BLINDS | | | AND AWNINGS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-13 |
Time |
13:34 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2004-01-13 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 03120591 | | | ADD: 533 CLEMATIS STREET | | | CONT: SHAKMAN CONSTRUCTION | | | TEL: (561)239-9018 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST BUILDING REVIEW: | | | ACTION: DENIED | | | NOTE: | | | 3401.7.2.6 WHEN REPAIRS AND ALTERA- | | | TIONS AMOUNTING TO MORE THAN 50% OF THE | | | VALUE OF THE EXISTING BUILDING ARE MADE | | | DURING ANY 12 MONTH PERIOD, THE BUILDING | | | OR STRUCTURE SHALL BE MADE TO CONFORM TO | | | THE REQUIREMENTS FOR A NEW BUILDING OR | | | STRUCTURE OR BE ENTIRELY DEMOLISHED. | | | | | | | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | A SURVEY OR PLOT PLAN INDIATING THE PROP | | | ERTY LINES, AND THE DISTANCE AWAY FROM | | | THE PROPERTY LINE?THE DISTANCE THE | | | BUILDING STEPS BACK AT THE 2ND AND 3RD | | | FLOORS? WINDOW SIZES VS WALL %/ FLOOR. | | | 705.1.1.2 EVERY EXTERIOR WALL WITHIN | | | 15' OF A PROPERTY LINE SHALL BE EQUIPPED | | | WITH APPROVED OPENING PROTECTIVES. | | | | | | 2)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | STAIR# 2, IS THIS A FIRE ESCAPE OR CON- | | | SIDERED A EXTERIOR STAIR? A EXTERIOR | | | STAIR SHALL COMPLY WITH 1006.2.4, WITH | | | OPENING PROTECTIVES. | | | | | | 3) STAIR# 2 EXIT DOOR ON THE 2ND & 3RD | | | FLOORS, 1012.1.4 DURING ITS SWING, ANY | | | DOOR IN A MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED AT LEAST 1/2 OF THE | | | REQUIRED WIDTH OF LANDING. | | | | | | 4) 903.8.1 BUILDINGS 3 STORIES OR MORE. | | | ANY BUILDING 3 STORIES OR MORE IN HEIGHT | | | SHALL BE EGUIPPED WITH AN APPROVED AUTO- | | | MATIC SPRINKLER SYSTEMINSTALLED IN | | | ACCORDANCE WITH 903.1. A STRAIGHT | | | NFPA 13 SYSTEM WILL BE REQUIRED. | | | | | | 5) EXISTING STAIRS, 1007.1.1(3) EXTERIOR | | | AND INTERIOR EXIT STAIRWAYS SHALL BE CON | | | STRUCTED OF NONCOMBUSTIBLE MATERIALS | | | THROUGHOUT IN THE FOLLOWING BUILDINGS: | | | (3) ALL OTHER BUILDINGS 3 STORIES OR | | | MORE IN HEIGHT OR OCCUPIED BY MORE THAN | | | 40 PERSONS ABOVE OR BELOW THE LEVEL OF | | | EXIT DISCHARGE. | | | | | | 6) DISCREPANCY, SHEET A2.0 NOTE 11 INDI- | | | CATES THAT THIS FLOOR WILL REMAIN A WOOD | | | FLOOR SYSTEM VS S1,NOTE THIS AREA TO | | | REMAIN "EXPOSED EARTH SLAB"? | | | | | | 7) SHEET A-2.0 DEMO NOTES, INDICATE THE | | | USE OF CALCULTED FLOOR ASSEMBLIES | | | 709.6.2.1, WHAT THE PLANS DO NOT INDI- | | | CATE IS THE FASTENING SCHEDULE FOR THE | | | 3 LAYERS OF DRYWALL. | | | | | | 8) DRAFTSTOPPING 2305.2.2(2) FLOOR/ | | | CEILING ASSEMBLIES,(2) MULTIFAMILY, | | | TWO OR MORE UNITS R2, IN THE FLOOR/ | | | CEILING ASSEMBLIES ABOVE AND IN LINE | | | WITH THE TENANT SEPAERATION, WHEN TENANT | | | SEPERATION WALLS DO NOT EXTEND TO THE | | | FLOOR SHEATHING ABOVE. | | | | | | 9) SHEET S-2 INDICATES A DETAIL# 4, WOOD | | | JOIST TO WALL CONNECTION, WHERE IS THIS | | | USED? PLANS INDICATE THE REMOVAL OF | | | THREE COURSES (FACE SHELL) HOW WILL THE | | | REMAINDER OF THE WALL BE HELD IN PLACE? | | | | | | 10) SHEET S-2 DETAIL# "CONNECTION A" | | | THIS DETAIL INDICATES THE USE OF HILTI | | | HIT SYSTEM, IS THIS TO GO INTO THE | | | TERRA COTTA BLOCK, THE REMOVAL OF THE | | | FACE SHELL IS DESIGNATED FOR THE OPPO- | | | SITE SIDE OF THE WALL, ALSO HOW MANY | | | COURSES ABOVE AND BELOW THIS SYSTEM? | | | | | | 11) SHEET S-2 INDICATES HOW THE ELEVATOR | | | PENTHOUSE IS TO BE BUILT, SIDEWALLS, | | | PLYWOOD, TYPE V BUILDING SIDEWALLS ARE | | | TO BE NONCOMBUSTIBLE. | | | | | | 12) S-3 INDICATES THE LIVE LOADS FOR THE | | | 2ND & 3RD STORY AS 80 LBS FOR LIVE, | | | STAIRS ARE TO BE 100 LBS/ SQ FT. | | | | | | 13) STAIRWELL PROTECTION. | | | SHEET M.2.1 3RD FLOOR STAIR WELL HAS A | | | 12"X12" RA RUNNING THROUGH THE STAIRWELL | | | 1006.1.3.1 PENETRATIONS INTO & | | | THROUGH A STAIRWELL ENCLOSURE ASSEMBLY | | | ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, DUCTWORK & EQUIPMENT FOR INDE- | | | PENDENT STAIR PRESSURIZATION, SPRINKLER | | | PIPING, STANDPIPES AND ELECTRICAL CON- | | | DUIT SERVING THE STAIRWAY AND TERMINAT- | | | ING AT A STEEL BOX NOT EXCEEDING 16 SQ | | | INCHES. | | | | | | 14)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: FRONT ENTRY DOORS | | | | | | 15) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 16)1503.4.2 OVERFLOW DRAINS SHALL BE | | | THE SAME SIZE AS ROOF DRAINS, INSTALLED | | | WITH THE INLET FLOW LINE LOCATED 2" | | | ABOVE THE LOWEST POINT OF THE ROOF LINE. | | | OVERFLOW SCUPPERS SHALL BE A MINIMUM OF | | | 4"IN HEIGTH AND SHALL BE PLACED IN WALLS | | | OR PARARETS WITH THE INLET FLOW LINE | | | NOT LESS THAN 2" ABOVE THE ROOF SURFACE. | | | | | | 17) 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 18)1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE | | | MECHANICAL EQUIPMENT, APPLIANCES AND SUP | | | PORTS THAT ARE EXPOSED TO WIND SHALL BE | | | DESIGNED AND INSTALLED TO RESIST THE | | | WIND PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 19) FAIR HOUSING ACCESSIBLE ROUTE 4.3 | | | SHOW AN ACCESSIBLE ROUTE FOR THE SITE. | | | INDICATE THE HANDICAPPED PARKING, ACCESS | | | ISLES, AND ROUTE TO THE ELEVATOR. ALSO | | | PROVIDE INFORMATION FOR ROUTE FOR PUBLIC | | | TRANSPORTATION. | | | INDICATE ALL SIDEWALKS, RAMPS, | | | STAIRS, AND CURB CUTS.4.4/ 4.5 | | | | | | 20) SHEET A2.5 WATER CLOSET GRAB BARS, | | | THE DETAIL INDICATES A 24" SIDE GRAB BAR | | | BUT FIG 604.5.1 INDICATES A MINIMUM OF | | | 42" PLUS 12" FROM THE BACK WALL. | | | | | | 21) SHEET A-6.1 FIRST FLOOR FRONT ENTRY | | | DOORS VS PROPERTY LINE NOT GIVEN. | | | 3203.1 DOORS SHALL NOT OPEN OR | | | PROJECT UPON PUBLIC PROPERTY. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-18 |
Time |
19:30 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-08-18 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2005-08-18 00:00:00 | REDLINED 620.23 AND 620.24 | | | LTS FOR BOTH STILL SHOWN ON ONE CIRCUIT | | | FOR LIGHTING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-11 |
Time |
14:04 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-08-11 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2005-08-11 00:00:00 | ********** PROVISO *********** | | | | | | 1)NOTE: PLEASE SEE ELEVATRO MACHINE ROOM | | | AND PIT REQUIRES EACH A SEPARATE BRANCH | | | CIRCUIT FOR LIGHTING AND RECEPTS. | | | PLEASE ALSO SEE MISSING GFI RECEPT TO BE | | | LOCATED ON ELEVATOR MACHINE RM. | | | 620.23,620.24 | | | | | | 2)NOTE: PLEASE SEE EM LTS AND EXT LTS | | | REFERENCE TO A NOTE #2 TYP. | | | PLEASE SEE NOTE #2 ON "FIRST AND SECOND | | | FLR NOTES"REFERS TO ALL EM/EXT LTS TO | | | BE WIRED AHEAD OF APT UNIT LIGHTING | | | SWITCHES. | | | PLEASE SEE 210.25, COMMON AREA BRANCH | | | CIRCUITS MAY NOT BE CIRCUITED TO | | | DWELLING/APT UNITS. | | | PLEASE SEE PLANS FOR COMMON AREA APPEAR | | | TO BE CIRCUITED CORRECTLY TO A HOUSE | | | PANEL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION. | | | NOTE #1 TO BE REVISED ON PLANS,CAN BE 8 | | | 1/2 X 11'S FOR REVISED PANEL SCHEDULE | | | AND ELEV RM LAYOUTS. | | | NOTE #2 CAN BE REVISED IN LTR FORM. | | | | | | PLEASE SUBMIT BEFORE FINAL/CO. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-31 |
Time |
08:53 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-01-31 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-25 |
Time |
15:52 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-25 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-07 |
Time |
14:15 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-06-07 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2004-06-07 00:00:00 | *************** UNSAT ************** | | | | | | 1)NOTE: IN RESPONSE TO PREVIOUS NOTES, | | | A CERTIFICATE OF AUTHORIZATION # WAS ADD | | | -ED TO SHEETS. THE FIRM NAME CORRESPOND- | | | ING TO THAT CA# HAS NOW CHANGED. | | | PLEASE SEE SOME SHEETS STILL CONTAIN | | | OTHER FIRM NAME AND PLEASE SEE TITLE | | | BLOCK ALSO CONTAINS OLD FIRM NAME EVEN | | | ON REVISED SHEETS. | | | OLD SHEETS WERE NOT CORRECTED. | | | PLEASE SEE FS 471.023/ FAC 61G15-23.002 | | | THIS IS REQUIRED ON ALL SHEETS WHEATHER | | | OR NOT COMMENT IS MADE FROM OTHER REVIEW | | | -ERS. | | | | | | | | | | | | 2)NOTE: PLEASE SEE NEW ELECTRICAL SHEETS | | | ARE NOW SEALED BY A NEW ENGINEER AND OLD | | | SHEETS CONTAIN A DIFFERENT ENGINEER? | | | PLEASE SEE FS 471.025 WHICH REQUIRES A | | | "SIGNATURE". THIS SIGNATURE MUST BE AS | | | SHOWN ON SEAL. NEW ENGINEERFIRST NAME | | | ONLY CONTAINS AN INITIAL. PLEASE SIGN | | | W/ LEGAL SIGNATURE. | | | | | | 3)NOTE: NOTE: ARC FAULT PROTECTION WILL | | | BE REQ'D FOR SD'S IN SLEEPING AREAS | | | PER 210.12 EVEN IF ON KITCHEN LT CIRCUIT | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLYINSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS MAY BE SUBMITTED | | | FOR REFERENCE. SOME REVIEWS MAY REQUIRE | | | THIS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-03 |
Time |
11:29 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-03-03 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE PLUMB COMMENTS ON FIRST | | | REVIEW. TITLE BLOCKS ARE REQ'D TO HAVE | | | ALL LICENSE #'S AS REQ'D UNDER | | | FS 471.023 BE LISTED. THIS IS REQ'D FOR | | | ALL SHEETS AND ALL TRADES. COMMENT WAS | | | NOT MADE BY ELECTRICAL REVIEW DUE TO | | | PLUMB MAKING COMMENT. | | | PLEASE NOTE: COMMENT IS NOW BEING MADE | | | BY ELECTRICAL AND NOT PLUMB HOWEVER | | | THIS IS REQ'D PER FAC 61G15-23.002 FOR | | | ALL. | | | | | | 2)NOTE: PLEASE SEE PLANS NOW SHOW CIR- | | | -CUITING AS REQUESTED ON FIRST REVIEW. | | | PLEASE SEE 210.11C1, PLANS SHOW ONLY | | | ONE SMALL APPLIANCE CIRCUIT. | | | | | | 3)NOTE: PLEASE SEE 220.16A FOR MIN LOAD | | | TO BE IN LOAD CALCULATIONS. | | | SHOWN AS 1 KVA? | | | | | | 4)NOTE: PLEASE CORRELATE CIRCUITS ON | | | PLANS WITH PANEL SCHEDULE. PLEASE SEE | | | SD'S AND STILL SHOWN ON WITH KITCHEN | | | LTS? CIRCUIT # SEEMS TO AHVE BEEN | | | CHANGED ON PLAN, BUT NOT PANEL SCHEDULES | | | | | | 5)NOTE: PLEASE SEE EQUIPMENT GROUNDING | | | CONDUCTORS HAVE NOW BEEN ADDED, HOWEVER | | | PLEASE SEE 250.24. EQUIPMENT GROUNDING | | | CONDUCTORS ARE ONLY INSTALLED AFTER THE | | | FIRST MEANS OF DISC. AS SHOWN PARALLELS | | | THE NEUTRAL. 250.6 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-23 |
Time |
13:19 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-12-23 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | *************** UNSAT ************** | | | | | | PLEASE SEE COMMENTS FROM OTHER PLANS | | | REVIEWERS, AS THEY MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | 1)NOTE: PLEASE SEE 210.52 FOR RECEPT | | | SPACING. SEE W/IN 6' OF EDGE OF WALL AND | | | 2' OF WALL. | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS. PLEASE SEE SOME MISSING. | | | APT 2-1, APT 2-2. | | | | | | 3)NOTE: PLEASE SEE 700.12E FOR CIRCUIT- | | | -ING OF EM/EXT LTS. | | | | | | NOTE # 2 NOT PERMITTED. | | | 4)NOTE: PLEASESHOWS SD'S AS REQUIRED | | | PER NFPA-8-1. | | | PLEASE ALSO SEE 210.12 FOR CIRCUITING | | | OF SD'S. PANEL SCHEDULE SHOWS SD'S W/ | | | KITCHEN LTS. | | | | | | 5)NOTE: PLEASE SEE 250.24 FOR PLACEMENT | | | OF EQUIPMENT GROUNDING CONDUCTOR. | | | NONE UNTIL AFTER THE FIRST MEANS OF | | | DISC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-9717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-02-14 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-02-14 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2005-02-14 00:00:00 | REVISION DATED 01-20-05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-07-08 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-07-08 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-02-20 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-02-20 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2004-02-20 00:00:00 | PLANS ARE APPROVED PROVISO IF ACCEPTED | | | BY THE CONSTRUCTION SERVICES DEPT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-18 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-18 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2003-12-18 00:00:00 | 1) TACTILE SIGNAGE IS REQUIRED AT | | | STAIRWELL DOORS. | | | | | | 2) ALL SHAFTWAYS THAT ARE LARGE ENOUGH | | | FOR PERSONS TO FALL INTO MUST BE MARKED | | | "SHAFTWAY" WITH 6" HIGH LETTERS. | | | | | | 3) NO FIRE SPRINKLER PLANS PROVIDED | | | WITH DRAWINGS. | | | | | | 4) PLEASE INDICATE ON THE PLANS, THE | | | REQUIRED EMERGENCY LIGHTS WITHIN STAIRS | | | 1 & 2. | | | | | | 5) PLEASE PROVIDE MORE DETAILS FOR | | | NOTE # 4 ON PAGE A-6.1. | | | | | | 6) A KNOX-BOX WILL BE REQUIRED FOR | | | THE BUILDING. | | | | | | 7) ELEVATOR WARNING SIGNS ARE REQUIRED | | | FOR THE BUILDING AT EACH ELEVATOR | | | OPENING. | | | | | | 8) NO ELEVATION DRAWINGS PROVIDED WITH | | | PLANS. | | | | | | 9) WHY ARE THE JANITOR'S CLOSET AND | | | LAUNDRY ROOM DOORS NOT FIRE RATED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-07 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-07 |
Time |
08:40 |
Sent To |
M |
|
| Notes |
| 2005-09-07 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-31 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-31 |
Time |
10:54 |
Sent To |
P |
|
| Notes |
| 2005-08-31 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
17:22 |
Sent To |
E |
|
| Notes |
| 2005-08-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
| 2005-07-06 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2005-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-19 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-19 |
Time |
15:56 |
Sent To |
B |
|
| Notes |
| 2005-04-19 00:00:00 | TO "LMARTINEZ" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-01 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-01 |
Time |
16:14 |
Sent To |
M |
|
| Notes |
| 2005-03-01 00:00:00 | TO "M"BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-22 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-22 |
Time |
16:16 |
Sent To |
M |
|
| Notes |
| 2005-02-22 00:00:00 | TO "M" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-25 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-25 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2005-01-25 00:00:00 | TO "COMM BD#47"/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2004-12-29 00:00:00 | TO "JW" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-19 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-19 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2004-11-19 00:00:00 | TO JW DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
16:51 |
Sent To |
B |
|
| Notes |
| 2004-10-20 00:00:00 | TO JW DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-22 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2004-09-22 00:00:00 | TO JW DESK/SUBMITTAL | | | STOREFRONT PA & STOREFRONT SHO DRAWINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-20 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-20 |
Time |
11:36 |
Sent To |
B |
|
| Notes |
| 2004-08-20 00:00:00 | TO JW DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2004-06-25 00:00:00 | TO COMM BD#39 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-24 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-24 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | TO COMM BD #51 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-19 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-19 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2004-02-19 00:00:00 | TO COMM BD#16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-19 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-11 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2003-12-11 00:00:00 | TO COMM BD#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-07 |
Time |
10:57 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-09-07 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-04 |
Time |
07:40 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-03-04 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | PROVISO: | | | 1.A MINIMUM OF 4" AROUND THE AHU IS | | | REQUIRED PER 2001 FBC(M)603.1.3. | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 | | | FBC(M)307.2.3. | | | 3.DRYER EXHAUST SHALL TERMINATE | | | OUTSIDE THE BUILDING AND BE NON-SCREENED | | | WITH A BACKDRAFT DAMPER PER 2001 | | | FBC(M)504.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-03 |
Time |
07:11 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-02-03 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2005-02-03 00:00:00 | DENIED: | | | 1.PLAN SHEET M2.1 SECOND AND THIRD | | | FLOOR, AHU2-3 & 3-3,THE OUTSIDE AIR | | | APPEARS TO TERMINATE IN THE KITCHEN. | | | OUTSIDE AIR IS TO BE DUCTED TO A CLOSE | | | PROXIMITY OR INTO THE RETURN AIR SO THE | | | OUTSIDE AIR WILL BE CIRCULATED THROUGH | | | THE AHU. | | | | | | 2.RETURN AIR TO RTU-1 IS NOT SIZED | | | PROPERLY.PER 2001 FBC(M)601.4, | | | BALANCED RETURN REQUIRED. | | | | | | 3.RETURN AIR GRILLE TO RTU-1 IS | | | TERMINATING AT A RATED WALL BUT A FIRE | | | DAMPER IS NOT INDICATED. | | | | | | 4.PLANS DO NOT INDICATE THE VENTING | | | OR TERMINATION OF THE DRYER EXHAUST. | | | PLEASE CLARIFY. | | | | | | PLEASE NOTE, LOUVERED DOOR IS PART OF | | | THE RETURN AIR PLENUM AND SHALL BE NON | | | COMBUSTIBLE PER 2001 FBC(M)602.2.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-01 |
Time |
15:44 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-07-01 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2004-07-01 00:00:00 | PROVISO: | | | 1.PER FAIR HOUSING ACT; SEE PLAN SHEET | | | A2.4 FIGURE 2 FOR HEIGHT REQUIREMENTS | | | FOR ENVIRONMENTAL CONTROLS AND SWITCHES. | | | | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-10 |
Time |
12:20 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-06-10 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | DENIED: | | | SEE COMMENT #1 BY DEWEY PALMER, | | | ELECTRICAL PLAN REVIEW.PLANS ARE | | | OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-04 |
Time |
07:01 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-03-04 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | DENIED: | | | 1.REFERENCE RESPONSE LETTER, | | | MECHANICAL; COMMENT/RESPONSE #2 - | | | OUTSIDE AIR PROVIDED THROUGH HALLWAY. | | | PER 2001 FBC(M) 403.2.1 #1 VENTILATION | | | AIR SHALL NOT BE RECIRCULATED FROM ONE | | | DWELLING TO ANOTHER OR DISSIMILAR | | | OCCUPANCIES. | | | | | | 2.REFERENCE RESPONSE LETTER, | | | MECHANICAL - RESPONSE TO COMMENT #5, | | | VERTICAL RUNS MOVERD TO A FIRE RATED | | | SHAFT WEST OF THE ELEVATOR.PLANS DO | | | NOT INCLUDE A DETAIL OR UL # FOR THE | | | SHAFT ASSEMBLY.PLEASE PROVIDE DETIALS | | | FOR THE CONSTURCTION OF THE SHAFT. | | | | | | 3.COMMENT/RESPONSE #7, REFRIGERANT | | | LINES MOVED INTO SHAFT.PLEASE NOTE | | | SHAFT ENCLOSURE SHALL BE FIRE-RESISTANT | | | AND VENTED TO THE OUTSIDE OR TO THE | | | SPACE SERVED BY THE SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-29 |
Time |
12:44 |
Rev Time |
1.35 |
| Received By |
pkrauss |
Date |
2003-12-29 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2003-12-29 00:00:00 | DENIED: | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | 1.OUTSIDE AIR CALCULATIONS PER 2001 | | | FBC(M) TABLE 403.3. | | | | | | 2.INDICATE LOCATION OF THE OUTSIDE AIR | | | DUCT TO THE AHU'S LOCATED ON THE 2ND | | | FLOOR. | | | | | | 3.PROVIDE MINIMUM VENTILATION REQUIRE- | | | MENTS FOR THE 1ST FLOOR PER 403.4.1. | | | | | | 4.PLAN SHEET M2.1 INDICATES THE SUPPLY | | | AND RETURN DUCTS FROM RTU-1 PENETRATING | | | THROUGH A STAIR WELL ENCLOSURE.PER | | | 2001 FBC 1006.1.3.1, DUCTWORK IS NOT | | | ALLOWED TO PENETRATE A STAIRWAY | | | ENCLOSURE, PLEASE CLARIFY. | | | | | | 5.PLAN SHEET M2.1 DUCTWORK FROM RTU-1, | | | DUCTS PENETRATING ONLY ONE FLOOR OF A | | | BUILDING REQUIRING THE PROTECTION OF | | | VERTICAL OPENINGS SHALL HAVE A FIRE | | | DAMPER.DUCTS THAT PENETRATE MORE THAN | | | ONE FLOOR SHALL BE PROTECTED BY A SHAFT | | | ENCLOSURE PER 2001 FBC(M) 607.1.2 #3 & | | | 607.4 RESPECTIVELY. | | | | | | 6.PLAN SHEET M6.1 CONDENSING UNIT | | | DETAIL, HEIGHT REQUIREMENT FROM THE | | | ROOF SURFACE TO THE BOTTOM OF THE | | | SUPPORT RAIL SHALL COMPLY WITH 2001 FBC | | | 1511.7. | | | | | | 7.REFRIGERANT PIPING SHALL COMPLY WITH | | | 15-1992 SUB SECTION 11.12.3(B) & 11.12.4 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-30 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-30 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2005-09-30 00:00:00 | REVISION, WATER HAMMER ARRESTORS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-09-20 |
Time |
13:41 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-09-20 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2005-09-20 00:00:00 | REVISION #8 APPROVED FOR SHEETS P2.1, | | | P2.2, P5.1, & P5.2. SHEET P5.3 REVISION | | | DENIED. REMOVED ALL REQUIRED WATER | | | HAMMER ARRESTORS FROM RISER DIAGRAMS. | | | SECTION 604.9 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-08 |
Time |
11:50 |
Rev Time |
3.50 |
| Received By |
kstevens |
Date |
2004-07-08 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-15 |
Time |
17:43 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-06-15 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-28 |
Time |
10:08 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-02-28 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2004-02-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | A) COMMENT #4 FROM PREVIOUS REVIEW NOT | | | COMPLETLY ANSWERED. SHT P5.2 REMOVAL OF | | | HUB DRAIN AND CONDENSATE LINE DRAINING | | | IN TO IT IS NOT DELETED AS SUGGESTED. | | | B) COMMENT #5 FROM PREVIOUS REVIEW: | | | WORK SHEET FROM RODNEY COMPO REQUIRED AT | | | TIME OF PERMIT ISSUANCE. PLEASE SUBMIT. | | | C) COMMENT #6 FROM PREVIOUS REVIEW RE- | | | SPONSE NOTED, BUT AIR CHAMBERS ARE STILL | | | SHOWN ON WATER RISER DIAGRAMS. ALSO THE | | | WATER HAMMER ARRESTORS SHALL BE SHOWN ON | | | THE RISER DIAGRAM AT THE W/M, D.W. & THE | | | ICE MAKER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-22 |
Time |
14:13 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-12-22 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2003-12-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) SHT A2.2 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106, AND 1107 WITH ALL SUBSEC- | | | TIONS FOR EXISTING ROOF. SHOW 1/2 AREA | | | OF ALL VERTICAL WALLS & AREA OF ROOFS | | | THAT DRAIN DOWN TO THE ROOF FROM ABOVE. | | | INDICATE SIZE OF DOWNSPOUTS & SUBMIT A | | | DETAIL FOR ALL OPENINGS IN THE PARAPET | | | WALLS SHOWING ALL DIMENTIONS. IF PRIMARY | | | AND SECONDARY DRAINS DRAIN THROUGH THE | | | SAME OPENING, THE OPENING SHALL BE SIZED | | | ACCORDINGLY. | | | 2) SHT P0.1 GENERAL SPECIFICATIONS #2, & | | | PLUMBING LEGEND. AIR CHAMBERS ARE NOT | | | APPROVED, DELETE FROM PLANS. 604.9 | | | 3) SHT P0.1 DEMO NOTES: ALL CAPPED AND | | | ABANDONED PLUMBING LINES SHALL BE INSP- | | | ECTED PRIOR TO COVERING. | | | 4) SHT P2.1 HUB DRAIN IN SPRINKLER CON- | | | TROL ROOM #103 SHOWS 1" CONDENSATE | | | DRAINING INTO IT. CONDENSATE SHALL DRAIN | | | SEPARATELY OUTSIDE OF THE BLDG. AND TIE | | | INTO STORM, A CATCH BASIN, OR A DRY WELL | | | A RELIEF VENT IS REQUIRED AS CONDENSATE | | | EXITS THE BLDG. SAFE WASTE'S ARE NOT | | | APPROVED. SECTION 90-125(5) CITY CODE. | | | 5) GREASE INTERCEPTOR SHALL BE SIZED BY | | | UTILITY DEPT. CONTACT RODNEY COMPO, EN- | | | VIRONMENTAL COMPLIANCE, INDUSTRIAL PRE- | | | TREATMENT WASTE ORD. 2938-96 (561) 837- | | | 4074. | | | 6) SHT P5.3 ALL WATER RISER DIAGRAMS, | | | AIR CHAMBERS ARE NOT APPROVED, DELETE | | | FROM RISERS. WATER HAMMER ARRESTORS RE- | | | QUIRED BY 604.9 (ICE MAKERS/WASHMACHINES | | | & DISH WASHERS), SHALL BE LOCATED NEAR | | | THE FIXTURES IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AT THE TOP OF THE DROPS. | | | 7) SHTS P5.3 & P0.1 SUBMIT MANUF. SPECS. | | | SHEETS FOR TANKLESS WATER HEATER. MUST | | | SHOW LISTING FOR W/H. | | | 8) IF PRACTICING THROUGH A DULY AUTHOR- | | | IZED ENGINEERING BUSINESS, ENGINEERS | | | SHALL INDICATE THEIR CERTIFICATE OF | | | AUTHORIZATION ON THE TITLE BLOCK OF EACH | | | SHEET. 61G15-23.002(2) & FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|