| Plan Review Stops For Permit 03120536 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-03 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-03 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-20 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-20 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2004-10-20 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN | | | THE ENERGY CALC. FORMS. | | | | | | 4) SUBMIT PRODUCT APPROVALS FOR THE | | | OUTSWING ENTRY AND GARAGE DOORS. THE | | | PRODUCT APPROVAL THAT WAS SUBMITTED IS | | | FOR INSWING DOORS. | | | | | | 5) SUBMIT PRODUCT APPROVALS FOR THE | | | DOUBLE OUTSWING GLAZED FRENCH DOORS AT | | | THE FAMILY ROOM. | | | | | | 6)THE PRODUCT APPROVAL DRAWING SUBMITTED | | | FOR THE 9'X 7' OVERHEAD GARAGE DOOR HAS | | | A NEGATIVE DESIGN PRESSURE OF -36.2 PSF | | | AND THE PLANS SPECIFY A NEGATIVE OF | | | -39.8 PSF. SUBMIT DRAWINGS WITH DESIGN | | | PRESSURES EQUAL TO OR GREATER THAN THE | | | PRESSURES SPECIFIED ON PLANS. | | | | | | 7) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE TYPE OF MOUNT, ANCHOR TYPE AND | | | SPACING. THIS IS REQUIRED TO BE | | | SUBMITTED AT TIME OF PERMIT OR A | | | SEPARATE PERMIT AND FEES WILL BE | | | REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-15 |
Time |
18:22 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
2004-01-23 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2004-01-23 00:00:00 | DENIED | | | | | | 1) COMMENTS FROM FIRST REVIEW HAVE NOT | | | BEEN ADDRESSED. PLEASE MAKE CORRECTIONS | | | AND SUBMIT REQUESTED ITEMS. | | | NOTE: IN ORDER TO EXPEDIATE PLAN REVIEW | | | PLEASE SUBMIT THE OLD PLAN SHEETS WHEN | | | REVISED PLANS ARE RESUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-21 |
Time |
16:59 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-01-14 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | DENIED | | | | | | 1) PROVIDE COPY OF PAPERWORK FOR LOT | | | SUBDIVISION APPROVED BY CITY ZONING | | | DEPARTMENT AND NEW PCN FROM PALM BEACH | | | COUNTY. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) REVISE THE TYPE OF CONSTRUCTION FROM | | | TYPE V TO TYPE VI. BASED ON FBC TABLE | | | 600, THE PERCENT OF WALL ALLOWED AS | | | OPENINGS IS EXCEEDED AND THE EXTERIOR | | | WALLS WOULD HAVE TO HAVE A 2 HOUR FIRE | | | RATING IF IT TYPE V UNPROTECTED | | | CONSTRUCTION. | | | | | | 5) THE MAXIMUM PRESSURES FOR OPENINGS | | | LISTED ON SHEET 1 ARE INCORRECT. SEE FBC | | | TABLE 1606.2B, WALL ZONE 5, 140MPH WIND | | | SPEED AND 10 SQFT EFFECTIVE WIND AREA. | | | FOR GARAGE DOOR SEE FBC TABLE 1606.2E | | | FOR A 9'X7' DOOR AND ROOF ANGLE GREATER | | | THAN 10 DEGREES. | | | | | | 6) DETAIL 10 ON SHEET 3 FOR THE TIE BEAM | | | DETAIL SPECIFIES ONE #5 TOP AND BOTTOM, | | | BUT THE DRAWING SHOWS 2. PLEASE CORRECT. | | | | | | 7) SPECIFY THE SPACING OF THE WEDGE | | | ANCHORS FOR THE GARAGE DOOR BUCKS IN THE | | | DETAIL ON SHEET 5. THE DIAMETERS OF THE | | | WEDGE ANCHORS ARE GIVEN AS 1/2" AND 3/8" | | | PLEASE INDICATE WHICH ONE IS CORRECT. | | | | | | 8) PROVIDE A BUCK DETAIL FOR THE SIDE | | | SWING DOORS. | | | | | | 9) STRUCTURAL NOTE #11 ON SHEET 5 CALLS | | | FOR THE ROOF SHEATHING TO BE NAILED WITH | | | 10D NAILS WHICH CONFLICTS WITH THE OTHER | | | NOTES REQUIRING 8D NAILS. PLEASE CORRECT | | | | | | 10) THE OWNER/AGENT IS REQUIRED TO SIGN | | | AND DATE THE ENERGY CALC. FORM. | | | | | | 11) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | SUBMIT FOR ALL WINDOWS, DOORS, ROOFING, | | | STORM PANELS AND TRUSS CONNECTORS. | | | | | | 12) SUBMIT THE DRAWINGS FOR THE SINGLE | | | HUNG WINDOWS WHICH ARE MISSING FROM THE | | | PRODUCT APPROVAL. | | | | | | 13) SUBMIT PRODUCT APPROVALS FOR THE | | | SINGLE OUTSWING DOORS AND DOUBLE | | | OUTSWING GLAZED FRENCH DOORS. | | | | | | 14) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. INDICATE | | | THE TYPE OF MOUNT, TYPE OF ANCHORS AND | | | ANCHOR SPACING. THIS INFORMATION IS | | | REQUIRED AT TIME OF APPLICATION OR A | | | SEPARATE PERMIT AND FEE WILL BE REQUIRED | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-22 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-22 |
Time |
18:50 |
Sent To |
PC |
|
| Notes |
| 2006-02-22 00:00:00 | REVISED RISER OK, STAMPED RISER. | | | | | | SUBMITTED REVISED PANEL SCHEDULE AND | | | LOAD CALCS RETURNED TO CONTRACTOR, CODE | | | COMMENTS NOT APPLIED TO THIS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-25 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-25 |
Time |
16:00 |
Sent To |
PC |
|
| Notes |
| 2006-01-25 00:00:00 | **********UNSAT ********* | | | | | | 1)NOTE: PLEASE SEE ADDRESSING NEEDS TO | | | BE CORRECTED AS OUR SYSTEM IS SHOWING | | | 414 MADDOCK, THE PLANS IN FILE INDICATE | | | 414 ALSO, HOWEVER LTR IN FILE MENTIONS | | | 410 AND REV COVER SHEET INDICATES 408. | | | PLEASE KNOW, ALL PLANS ON FILE CONTAIN | | | 414 IN THE TITLE BLOCK WHERE FAC | | | 61G15-23.002, 61G1-16.004 REQUIRES THE | | | CORRECT ADDRESS FOR PROJECT TO BE ON THE | | | TITLE BLOCKS FOR JOB. | | | | | | 2)NOTE: PLEASE SEE RISER DIAGRAM | | | INDICATES THE INSIDE PANEL (GARAGE) | | | BEING FED BACK THROUGH THE METER CAN | | | SHOWING LINE AND LOAD IN THE METER. | | | PLEASE SEE THIS IS NOT PERMITTED.250.6 | | | ETC . | | | | | | 3)NOTE: PLEASE SEE SERVICE IS SHOWING A | | | MCB PANEL LOCATED OUTSIDE , HOWEVER IT | | | IS HAS COME TO THE ATTENTION OF THIS | | | OFFICE THAT THERE IS NO PANEL LOCATED | | | OUTSIDE , AND ONLY A MAIN DISCONNECT? | | | PLEAS CONFIRM AND REVISE ACCORDINGLY. | | | | | | 4)NOTE: PLEASE PROVIDE REVISED PANEL | | | SCHEDULE AS, SERVICE IS NOW SHOWN BEING | | | DOWNGRADED TO 150A'[S WHEN ORIG PLANS | | | CALLED FOR 200A'S, PLEASE PROVIDE ANY | | | UPDATED CHANGES IN LOADS OR CIRCUITING. | | | 215.5 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-09-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-23 |
Time |
13:47 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-09-23 |
Time |
13:46 |
Sent To |
P |
|
| Notes |
| 2004-09-23 00:00:00 | OWES RE-SUB FEE, THIS IS THIRD REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-20 |
Time |
07:30 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-01-21 |
Time |
16:59 |
Sent To |
B |
|
| Notes |
| 2004-01-21 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE THAT NO NOTES WERE | | | ADDRESSED FROM THE ORIGINAL REVIEW. | | | SAME PLANS CAME BACK IN W/OUT ANY CHANGE | | | -S??? | | | | | | PLEASE SEE COPY OF FS 553.80 (2)(B) | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
10:07 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-12-23 |
Time |
07:00 |
Sent To |
M |
|
| Notes |
| 2003-12-23 00:00:00 | *************** UNSAT ************ | | | | | | 1)NOTE: PLEASE PROVIDE AIC RATING FOR | | | MAIN/ PANEL. 110.9 MAINS/PANELS/BRKRS | | | ARE ALL TO BE RATED FOR THE AVAILABLE | | | FAULT CURRENT. | | | | | | 2)NOTE: PLEASE SEE NOTES ABOVE RISER | | | DIAGRAM. PLEASE SEE NEC 680.22A5 FOR | | | GFI'S AROUND POOL AREA. 20' NOT 15' | | | PLEASE ALSO SEE 210.8A6 FOR GFI PROTECT- | | | ION FOR RECEPTS SERVING KITCHEN COUNTER- | | | SPACE IN KITCHENS. 6' RULE CHANGED | | | | | | 3)NOTE: PLEASE SEE THAT A GARAGE DOOR | | | OPENER CIRCUIT ON PANEL SCHEDULE AND | | | LOAD, HOWEVER PLANS DO NOT SHOW/INDICATE | | | THIS RECEPT IN GARAGE. | | | | | | 4)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPT IN BEDROOM? | | | | | | 5)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | | ON PLANS. | | | | | | 6)NOTE: PLEASE SEE 210.52C3 FOR MISSING | | | RECEPT AT PENINSULAR. | | | | | | 7)NOTE: PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE PER 210.12. PLEASE ALSO SEE | | | THE 2002 NEC AS THIS HAS CHANGED FROM | | | THE 1999 NEC | | | | | | 8)NOTE: THIS IS ONLY A NOTE: PLEASE SEE | | | THAT "PHONE" IS ONLY SHOWN IN KITCHEN | | | AND ONE BEDROOM. PLEASE SHOW ALL | | | LOCATIONS OF LV AT THIS TIME. IF NOT | | | THNE REVISED PLANS WOULD HAVE TO BE | | | SUBMITTED AT A LATER DATE. THIS IS JUST | | | A NOTE; SPEAKER WIRING ETC. | | | | | | 9)NOTE: PLEASE SEE BOTH SMALL BEDROOMS | | | SHOW A J-BOX IN CEILING W/ NO MEANS | | | OF CONTROL? THIS IS ALSO JUST A NOTE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-17 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-17 |
Time |
11:30 |
Sent To |
E |
|
| Notes |
| 2006-02-17 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:19 |
Sent To |
E |
|
| Notes |
| 2006-01-22 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-01 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-01 |
Time |
12:13 |
Sent To |
B |
|
| Notes |
| 2004-11-01 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-20 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-20 |
Time |
07:30 |
Sent To |
E |
|
| Notes |
| 2004-09-20 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-20 |
Time |
10:07 |
Sent To |
E |
|
| Notes |
| 2004-01-20 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-16 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-15 |
Time |
16:28 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-14 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-03 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | 12/10/03TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-23 |
Time |
07:04 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-12-30 |
Time |
18:41 |
Sent To |
P |
|
| Notes |
| 2003-12-30 00:00:00 | NO PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-15 |
Time |
18:22 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-10-15 |
Time |
18:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-23 |
Time |
13:47 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-01-03 |
Time |
06:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-20 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-12 |
Time |
16:21 |
Sent To |
B |
|
| Notes |
| 2004-10-20 00:00:00 | VARIANCE APPROVED ON 3/12/04 CASE# 3102 | | | BY JOHN ROACH, PLANNER 822/1448 MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-16 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-16 |
Time |
14:26 |
Sent To |
I |
|
| Notes |
| 2004-01-16 00:00:00 | OK TO PASS ON TO BLDG PER SHIRLEY GRAHAM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-15 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-14 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | DENIED, NEED TO APPLY FOR A VARIANCE OR | | | SHOW PROOF OF SUBDIVSION CALL CONTR FILE | | | A FOR PICK UP MM |
|
|