Plan Review Details - Permit 03120429
Plan Review Stops For Permit 03120429
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-12-18 Cont ID  
Sent By btrobaug Date 2004-01-13 Time 12:34 Rev Time 0.50
Received By lsmith Date 2003-12-18 Time 15:42 Sent To  
Notes
2003-12-18 00:00:00BUILDING PASSED BUT CAN NOT SIGN OFF
 UNTIL PLUMBING & ELECTRICAL ARE
 CORRECTED. LS

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-01-13 Cont ID  
Sent By btrobaug Date 2004-01-13 Time 12:34 Rev Time 0.33
Received By btrobaug Date 2004-01-13 Time 12:25 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-01-12 Cont ID  
Sent By kstevens Date 2004-01-13 Time 12:22 Rev Time 0.33
Received By btrobaug Date 2004-01-12 Time 14:01 Sent To  
Notes
2004-01-12 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~`
 PER 104.2.1 FBC (ATTACHED) THE
 ELECTRICAL DRAWING MUST BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-12-17 Cont ID  
Sent By kstevens Date 2004-01-10 Time 15:18 Rev Time 0.33
Received By btrobaug Date 2003-12-17 Time 15:40 Sent To P
Notes
2003-12-17 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 THERE ARE NO ELECTRICAL SCHEMATIC OR
 DRAWINGS SUBMITTED FOR REVIEW.
  
 NOTE: PLEASE NOTE THAT ALL PLANS
 DRAWN BY AN ARCHITECT/ENGINEER CONTAIN-
 ING A TITLE BLOCK, MUST BE SIGNED,
 DATED AND SEALED BY THE ARCH/ENGINEER OF
 RECORD. PER FS/FAC 481.221 & 471.025
 INITIALED SEALS DO NOT MEET THE INTENT
 PER FBPE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-29 Cont ID  
Sent By csiegber Date 2003-12-29 Time 14:48 Rev Time 0.00
Received By csiegber Date 2003-12-29 Time 14:48 Sent To P
Notes
2003-12-29 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-12 Cont ID  
Sent By csiegber Date 2003-12-12 Time 09:26 Rev Time 0.00
Received By csiegber Date 2003-12-12 Time 09:26 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-08 Cont ID  
Sent By csiegber Date 2003-12-08 Time 14:18 Rev Time 0.00
Received By csiegber Date 2003-12-08 Time 14:18 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-01-13 Cont ID  
Sent By kstevens Date 2004-01-13 Time 12:22 Rev Time 0.50
Received By kstevens Date 2004-01-13 Time 12:22 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-01-10 Cont ID  
Sent By kstevens Date 2004-01-10 Time 15:18 Rev Time 0.33
Received By kstevens Date 2004-01-10 Time 15:17 Sent To E
Notes
2004-01-10 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FLA. ADMIN. CODE
 FLA. STATUTES
  
 1) COMMENT #5 FROM PREVIOUS REVIEW HAS
 NOT BEEN ADDRESSED. ENGINEERS SHALL
 SIGN THEIR SIGNATURE ON THEIR SEAL PER
 FAC 61G15-23.002(1) & FS 471.025. RULING
 BY THE FLORIDA BORD OF PROFESSIONAL
 ENGINEERS STATES THAT THE SIGNATURE IS
 REQUIRED AND INITIALS ARE NOT ACCEPTABLE
 2) PLEASE REMOVE ALL OLD PAGES AND IN-
 SERT NEW SHEETS AND SUBMIT 2 SETS OF
 PLANS FOR REVIEW. 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-12-18 Cont ID  
Sent By csiegber Date 2003-12-29 Time 14:48 Rev Time 0.50
Received By kstevens Date 2003-12-18 Time 10:22 Sent To B
Notes
2003-12-18 00:00:00DENIED
 REFERENCE: FBC-2001 242.2 SWIMMING POOLS
 FLA. ADMIN. CODE
 FLA. STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 5) ENGINEERS SHALL SIGN THEIR NAME ON
 THEIR SEAL PER FAC 61G15-23.002(1) AND
 FS 471.025. RULING BY FBPE STATES THAT
 THE MINIMUM OF A FIRST AND LAST NAME
 REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-11 Cont ID  
Sent By csiegber Date 2003-12-08 Time 14:18 Rev Time 0.00
Received By mmclean Date 2003-12-11 Time 16:43 Sent To P
Notes
***NONE***