| Plan Review Stops For Permit 03120429 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-13 |
Time |
12:34 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2003-12-18 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2003-12-18 00:00:00 | BUILDING PASSED BUT CAN NOT SIGN OFF | | | UNTIL PLUMBING & ELECTRICAL ARE | | | CORRECTED. LS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-13 |
Time |
12:34 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-01-13 |
Time |
12:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-01-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-13 |
Time |
12:22 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-01-12 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2004-01-12 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~` | | | PER 104.2.1 FBC (ATTACHED) THE | | | ELECTRICAL DRAWING MUST BEAR THE NAME | | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-10 |
Time |
15:18 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-12-17 |
Time |
15:40 |
Sent To |
P |
|
| Notes |
| 2003-12-17 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | THERE ARE NO ELECTRICAL SCHEMATIC OR | | | DRAWINGS SUBMITTED FOR REVIEW. | | | | | | NOTE: PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATED AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | INITIALED SEALS DO NOT MEET THE INTENT | | | PER FBPE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-29 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-29 |
Time |
14:48 |
Sent To |
P |
|
| Notes |
| 2003-12-29 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-12 |
Time |
09:26 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-08 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-08 |
Time |
14:18 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-13 |
Time |
12:22 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-13 |
Time |
12:22 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-10 |
Time |
15:18 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-10 |
Time |
15:17 |
Sent To |
E |
|
| Notes |
| 2004-01-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) COMMENT #5 FROM PREVIOUS REVIEW HAS | | | NOT BEEN ADDRESSED. ENGINEERS SHALL | | | SIGN THEIR SIGNATURE ON THEIR SEAL PER | | | FAC 61G15-23.002(1) & FS 471.025. RULING | | | BY THE FLORIDA BORD OF PROFESSIONAL | | | ENGINEERS STATES THAT THE SIGNATURE IS | | | REQUIRED AND INITIALS ARE NOT ACCEPTABLE | | | 2) PLEASE REMOVE ALL OLD PAGES AND IN- | | | SERT NEW SHEETS AND SUBMIT 2 SETS OF | | | PLANS FOR REVIEW. 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-29 |
Time |
14:48 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-12-18 |
Time |
10:22 |
Sent To |
B |
|
| Notes |
| 2003-12-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 242.2 SWIMMING POOLS | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 424.2.7.2 PUMPS AND EQUIP- | | | MENT SHALL BE MOUNTED ON A SUBSTANTIAL | | | BASE IN A MANNER THAT WILL ELIMINATE | | | STRAIN ON PIPING. SLAB SHALL BE A NOMIN- | | | AL 4" THICK. (DETAIL) | | | 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | | ORD. #2853-95, BACKFLOW REQUIRED ON | | | WATER SERVICE. (ADD TO NOTES) | | | 3) FBC-2001 424.2.12.1 PRESSURE TESTS. | | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | 4) FBC-2001 424.2.13.2JOINTS AND CON- | | | NECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | | NOTES) | | | 5) ENGINEERS SHALL SIGN THEIR NAME ON | | | THEIR SEAL PER FAC 61G15-23.002(1) AND | | | FS 471.025. RULING BY FBPE STATES THAT | | | THE MINIMUM OF A FIRST AND LAST NAME | | | REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-08 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-11 |
Time |
16:43 |
Sent To |
P |
|
| Notes |
|
|