Plan Review Details - Permit 03120428
Plan Review Stops For Permit 03120428
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-22 Cont ID  
Sent By csiegber Date 2004-10-25 Time 10:30 Rev Time 1.00
Received By lsmith Date 2004-01-22 Time 07:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-31 Cont ID  
Sent By hmoser Date 2004-01-21 Time 16:53 Rev Time 2.00
Received By lsmith Date 2003-12-31 Time 08:59 Sent To  
Notes
2003-12-31 00:00:00BUILDING PLANS REVIEW NOTES: FAILED:
  
 1. SURVEY SHOWS HOUSE IS TO BE A ONE
 STORY BUT PLANS SHOW 2 STORY MODEL.
  
 2) IMPACT FEES. THE PLANS SHALL BE
 TAKENTO PALM BEACH COUNTY BUILDING
 DEPARTMENTFOR IMPACT FEE ASSESSMENT.
 THEY SHALL BE STAMPED AT THAT OFFICE
 AND A COPY OF THE PAID RECEIPT SUBMITTED
 TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 4) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-19 Cont ID  
Sent By btrobaug Date 2004-03-19 Time 07:45 Rev Time 0.50
Received By btrobaug Date 2004-03-19 Time 07:38 Sent To  
Notes
2004-03-19 00:00:00 
 PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CLARITY AND INCLUDE WHEN SUBMITTING
 "AS-BUILT" DRAWINGS.
  
 1} LOCATION OF ADDED PANEL"B".
  
 2} INDICATE COMPLIANCE WITH 250.122 EQ.
 GROUND BETWEEN PANEL "A"AND"B".
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-12-12 Cont ID  
Sent By csiegber Date 2004-03-11 Time 11:32 Rev Time 0.33
Received By dpalmer Date 2003-12-12 Time 06:36 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-10-25 Cont ID  
Sent By csiegber Date 2004-10-25 Time 10:30 Rev Time 0.00
Received By csiegber Date 2004-10-25 Time 10:30 Sent To  
Notes
2004-10-25 00:00:00TO RYAN NUQUIST/RE INSPECTION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-11 Cont ID  
Sent By csiegber Date 2004-03-11 Time 11:32 Rev Time 0.00
Received By csiegber Date 2004-03-11 Time 11:32 Sent To E
Notes
2004-03-11 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 11:14 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 11:13 Sent To M
Notes
2004-01-21 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-31 Cont ID  
Sent By mmclean Date 2003-12-09 Time 11:47 Rev Time 0.00
Received By csiegber Date 2003-12-08 Time 12:38 Sent To  
Notes
2003-12-09 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-21 Cont ID  
Sent By hmoser Date 2004-01-21 Time 17:13 Rev Time 0.50
Received By hmoser Date 2004-01-21 Time 17:13 Sent To  
Notes
2004-01-21 00:00:00PASS PRIVISO
 RETURNAIR DUCT IN MASTER MUST BE 18 IN.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 11:14 Rev Time 0.25
Received By hmoser Date 2003-12-30 Time 14:29 Sent To B
Notes
2003-12-30 00:00:00DENIED:
 AHU #2 MISSING DUCT SIZE FROM THE AHU TO
 THE DISTRIBUTION TRIANGLE TO THE MASTER
 BEDROOM.RETURN AIR JUMPER IS NOT SIZED
 PROPERLY FOR THE MASTER BEDROOM.ALL
 SUPPLY AIR TO BE INCLUDED FOR THE TOTAL
 CALCULATION PER 2001 FBC(M) 601.4 #1.
 SEE THE ATTACHED SCHEUDLE FOR PROPER
 SIZING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-10 Cont ID  
Sent By jleech Date 2003-12-10 Time 18:55 Rev Time 0.25
Received By jleech Date 2003-12-10 Time 18:55 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-09 Cont ID  
Sent By mmclean Date 2003-12-09 Time 11:46 Rev Time 0.00
Received By mmclean Date 2003-12-09 Time 11:46 Sent To I
Notes
***NONE***