| Plan Review Stops For Permit 03120422 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-01-15 |
Time |
09:59 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-01-15 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-15 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-31 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | 3. A NOTICE OF COMMENCEMENT MUST BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-18 |
Time |
09:10 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-18 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
14:26 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-19 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2004-03-19 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} AN EQUIPMENT GROUND PER 250.122 IS | | | REQUIRED FROM PANEL "A" TO THE SUB- | | | PANEL. | | | | | | 2} THE SUB PANEL FEEDER ON THE PANEL"A" | | | SCHEDULE IS LISTED AS #14 ON A 15AMP | | | SINGLE POLE BREAKER. THE PREVIOUSLY | | | SUBMITTED PLAN WAS RETURNED TO THE | | | ARCHITECT WITH A COMMENT ABOUT THIS | | | FEEDER BEING A 2 POLE 20AMP. PEASE | | | INDICATE THE CORRECT OCP AND FEEDER | | | SIZE ON PLANS. | | | | | | 3} VERIFY THE LOCATION OF THE POOL | | | PANEL(SUB PANEL). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:27 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-02-23 |
Time |
07:30 |
Sent To |
P |
|
| Notes |
| 2004-02-23 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE ORIGINAL REDLINED | | | NOTES. | | | PLEASE CORRELATE PANEL SCHEDULES WITH | | | RISER DIAGRAM. 200A PANEL SHOWS A 2P20A | | | BRKR FEEDING 60A SUB PANEL? | | | PLEASE SEE LOAD. | | | | | | 2)NOTE: PLEASE REVISE LOAD CALCULATIONS | | | TO INCLUDE NEW LOADS. | | | LOADS WERE NOT ADDED TO 200A PANEL/SERV. | | | | | | 3)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM 200A PANEL | | | TO 60A SUB PANEL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
11:02 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-12-11 |
Time |
15:36 |
Sent To |
M |
|
| Notes |
| 2003-12-11 00:00:00 | REDLINED PLANS | | | | | | CORRELATE RISER DIAGRAM AND PANEL | | | SCHEDULE FOR SUB PANEL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-08 |
Time |
14:26 |
Sent To |
E |
|
| Notes |
| 2004-04-08 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
11:27 |
Sent To |
E |
|
| Notes |
| 2004-03-11 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-17 |
Time |
11:01 |
Sent To |
E |
|
| Notes |
| 2004-02-17 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-13 |
Time |
14:02 |
Sent To |
M |
|
| Notes |
| 2004-01-13 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-09 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-08 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2003-12-09 00:00:00 | TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-15 |
Time |
09:05 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-15 |
Time |
09:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:02 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-12-30 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | DENIED: | | | RETURN AIR JUMPERS NOT SIZED PROPERLY. | | | SEE ATTACHED SCHEDULE FOR PROPER SIZING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-26 |
Time |
18:44 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-02-26 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2004-02-26 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-23 |
Time |
07:30 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2003-12-10 |
Time |
17:46 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-09 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-09 |
Time |
11:51 |
Sent To |
I |
|
| Notes |
|
|