| Plan Review Stops For Permit 03120255 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-03-10 |
Time |
13:21 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2004-03-10 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2004-03-10 00:00:00 | BUILDINGPROVISO | | | 03120255 | | | 4065 N HAVERHILL | | | CHINA STAR RESTRAUNT | | | | | | FIRE SPRINKLERED BUILDINGS!!!!!!!!! | | | 2603.5.1.2(4) WHERE THE COOLER OR | | | FREEZER IS WITHIN A FIRE SPRINKLERED | | | BUILDING, BOTH THE COOLER AND FREEZER | | | AND PART OF THE BUILDING IN WHICH IT IS | | | LOCATED SHALL BE SPRINKLERED. | | | A SEPERATE PERMIT WITH PLANS SHALL BE | | | REQUIRED BEFORE A CERTIFICATE OF | | | OCCUPANCY SHALL BE ISSUED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-15 |
Time |
16:12 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-01-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03120255 | | | ADD: 4065 N HAVERHILL | | | CONT: QUALITY MAINENCE | | | TEL: (321)432-5666 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | BUILDING | | | 1SR REVIEW | | | | | | ACTION: DENIED | | | | | | 1) COMMENT# 2 FROM FIRE DEPARTMENT TO BE | | | VARIFIED. FIRE SPRINKLERED BUILDINGS | | | THAT CONTAIN WALK IN COOLERS ALSO RE- | | | QUIRE FIRE SPRINKLERS. | | | 2603.5.1.2(4) WHERE THE COOLER OR | | | FREEZER IS WITHIN A BUILDING, BOTH THE | | | COOLER AND FREEZER AND PART OF THE BUILD | | | ING IN WHICH IT IS LOCATED SHALL BE | | | SPRINKLERED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-10 |
Time |
08:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-10 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:25 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
21:34 |
Sent To |
|
|
| Notes |
| 2004-04-23 00:00:00 | ********** UNSAT 5TH TIME *********** | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004, | | | AND FS 481.219. PLEASE SEE TITLE BLOCK | | | STILL CONTAINS THE FICTITIOUS NAME OF | | | "PALM TREE DESIGN" | | | IF THIS NAME IS GOING TO REMAIN ON | | | TITLE BLOCK, THEN A CERTIFICATE OF | | | AUTHORIZATION # IS REQ'D. | | | PLEASE ALSO SEE ELECTRICAL SHEET IS NOW | | | SEALED OVER A COPY OF ARCH'S INITIALS/ | | | SIGNATURE. | | | PLANS MUST CONTAIN ORIGINAL SIGNATURE | | | AS REQ'D BY FS 481.221. | | | | | | PLEASE SEE THAT ONE SET OF PLANS ARE | | | NOW BEING RETAINED TO BE SENT INTO | | | DBPR/BOARD OF ARCH'S FOR REVIEW OF | | | SAID VIOLATIONS UNDER FS/FAC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-04-23 |
Time |
17:21 |
Rev Time |
0.26 |
| Received By |
dpalmer |
Date |
2004-04-19 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2004-04-19 00:00:00 | ******** UNSAT ********* | | | | | | 1)NOTE: PLEASE SEE NO NEW ELECTRICAL | | | SHEETS WERE SUBMITTED TO ADDRESS COMMENT | | | -S GIVEN ON 3/4/04. | | | PLEASE SEE FS 481.219 FOR REQ'D CERTIF- | | | -ICATE OF AUTHORIZATION #. | | | PLEASE SEE 61G1-16.004, ALL LICENSE | | | #'S ARE REQ'D TO BE ON TITLE BLOCK. | | | | | | 2)NOTE: PLEASE CORRECT CIRCUITING FOR | | | EM LTS WHEN REVISING SHEET. 700.12E | | | LETTER FROM ARCH WAS NOTED. | | | | | | COMMENT # 1 MUST BE ADDRESSED. | | | | | | **PLEASE REMOVE ALL OLD/ VOIDED SHEETS | | | AND INSERT NEW CORRECT SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-04-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
11:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-04-03 |
Time |
09:12 |
Sent To |
P |
|
| Notes |
| 2004-04-03 00:00:00 | | | | AS PER THE PREVIOUS REVIEWS THE | | | ARCHITECT FAILED TO RECIRCUIT THE | | | EMERGENCY/EXIT LIGHTS TO MEET THE | | | INTENT OF ARTICLE 700.12(E), ATTACHED. | | | THE EM/EXIT LIGHTS MUST BE FED FROM THE | | | LOCAL BRANCH LIGHTING CIRCUIT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
11:41 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-03-04 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | ************ UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004 FOR | | | ALL REQ'D LICENSE #'S ON TITLE BLOCK. | | | PLEASE SEE FS 481.219 FOR LICENSE'S | | | REQ'D. | | | | | | 2)NOTE: PLEASE SEE 700.12E FOR CIRCUIT- | | | -ING OF EM/ EXT LTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-01-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-07 |
Time |
06:28 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-07 |
Time |
06:28 |
Sent To |
|
|
| Notes |
| 2004-01-07 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE PROVIDE ALL LICENSE #`S | | | ON TITLE BLOCK FOR FIRM. PER FAC 61G1- | | | 16.004. PER FS 481 | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH A PANEL SCHED- | | | -ULE. IF SOME ARE EXISTING, PLEASE LABEL | | | AS "E" IF NEW ,,,,, | | | PLEASE SHOW WITH OCP/AWG ON PANEL SCHED- | | | -ULE. | | | | | | 3)NOTE: PLEASE SEE 700.12E FOR EM/EXT | | | LTS. PLEASE SEE FIRE REVIEW COMMENTS. | | | | | | 4)NOTE: PLEASE SEE EQUIPMENT SCHEDULE, | | | SHOWS "MR WINTER" WALK-IN COOLER AS 220V | | | , ELECTRICAL SERVICE IS SHOWN AS 208V, | | | PLEASE VERFIY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-02-27 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-02-27 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-02 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-02 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR NEW HOOD, DUCT, AND SUPPRESSION | | | SYSTEM. | | | | | | 2) PLANS INDICATE THAT THE PROPOSED | | | SPACE IS NOT FIRE SPRINKLER PROTECTED. | | | ACCORDING TO FIRE RESCUE PERSONNEL, | | | THE SPACE IS FIRE SPRINKLER PROTECTED. | | | PLEASE ADVISE. | | | | | | 3) NO EMERGENCY LIGHTS SHOWN ON PLANS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-02 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-02 |
Time |
08:37 |
Sent To |
M |
|
| Notes |
| 2004-08-02 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
15:25 |
Sent To |
E |
|
| Notes |
| 2004-05-04 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-04-23 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2004-04-23 |
Time |
17:21 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-14 |
Time |
11:31 |
Sent To |
E |
|
| Notes |
| 2004-04-14 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-30 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-30 |
Time |
11:41 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | TO COMM BD#25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-30 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-30 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | TO COMM BD#57 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-02 |
Time |
08:37 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-03-04 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | HVAC EXISTING REVISED O.A. CALCS ON PLAN | | | SHEET 2 OF 4.SEPARATE PERMIT REQUIRED | | | FOR THE HOOD, FIRE SUPPRESSION & | | | WALK-IN COOLERS. | | | | | | PLEASE NOTE - EXHAUST TERMINATION FOR | | | THE GREASE DUCT SHALL BE A MINIMUM OF | | | 10 FT FROM ADJACENT PROPERTY LINES, | | | CONTINGUOUS BUILDINGS AND AIR INTAKES. | | | 2001 FBC(M) 506.3.14.3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-08 |
Time |
07:12 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2004-01-08 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | DENIED: | | | PLEASE CLARIFY THAT THE MECHANICAL | | | CONTRACTOR SIGNED ON THE PERMIT | | | APPLICATION WILL BE DOING THE HVAC, | | | GREASE HOOD/GREASE DUCT AND WALK-IN | | | COOLER.SEPARATE PERMITS REQUIRED IF | | | OTHER CONTRACTORS ARE TO PERFORM WORK. | | | SEPARATE PERMIT REQUIRED FOR | | | SUPPRESSION, PLEASE PROVIDE PLANS WITH | | | PERMIT APPLICATION. | | | | | | HVAC: | | | 1.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS PER 2001 FBC(M) 403.3. | | | | | | 2.NOTE ON PLAN SHEET 2 OF 4 REFERS TO | | | SHEET 4 FOR AS-BUILT DRAWING.SHEET 4 | | | INDICATES GREASE DUCT. | | | | | | HOOD/GREASE DUCT: | | | 1.PLEASE INDICATE TERMINATION OF | | | GREASE DUCT IN RELATION TO THE PROPERTY | | | LINES, AND ADJACENT OR CONTINGUOUS | | | BUILDINGS. | | | | | | 2.EXHAUST FAN TO BE HINGED UPBLAST | | | TYPE PER NFPA 96 4-8.2.1 (E). | | | | | | 3.INDICATE SIZE OF GREASE DUCT ON | | | PLAN. | | | | | | 4.SUBMITTAL REQUIRED FOR THE FIRE | | | WRAP IF USED FOR CLEARANCE REDUCTION. | | | | | | WALK-IN COOLER: | | | PROVIDE MANUFACUTER SUBMITTAL DATA WITH | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-07 |
Time |
18:31 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-04-07 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2004-04-07 00:00:00 | PASSED PLUMBING ONLY | | | | | | MANUF. SPECIFICATION SHEETS FOR GAS | | | APPLIANCES REQUIRED AT TIME OF GAS PER- | | | MIT APPLICATION - INFORMATION REQUIRED | | | FOR LOCATION OF L-P TANK/TANKS - SUBMIT | | | A SITE PLAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-03 |
Time |
09:49 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-02-28 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2004-02-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | COMMENTS NOT ADDRESSED FROM FIRST REVIEW | | | NUMBERS TO REMAIN THE SAME FOR CLAIRITY. | | | 3) CONTACT RODNEY COMPO, ENVIRONMENTAL | | | COMPLIANCE FOR SIZING OF GREASE INTER- | | | CEPTOR. WASTE ORD #2938-96 (561) 837- | | | 4074. NEED COPY OF APPROVAL SHEET REC'D | | | FROM R. COMPO. | | | 4) SHT 3 OF 4 FLOOR SINK STILL REQUIRED | | | FOR ITEM #10. CHANGE WAS MADE TO MOP | | | SINK NOT SLOP SINK (#10). | | | 5) SHT 3 OF 4 GREASE RISER DIAGRAM, A | | | VENT IS REQUIRED FOR THE MOP SINK, SECT- | | | ION 901.2.1 - VENT CAN NOT COME OUT OF | | | DRAIN AS SHOWN. SEE RED LINE CORRECTION | | | FOR PROPER VENTING. | | | 6) FIRM LICENSE NUMBER REQUIRED PER FAC | | | 61G1-16.004(2) & FS 481.219 (SEE SHEETS | | | 1 OF 4 & 2 OF 4 - PINE TREE DESIGN) - | | | CERTIFICATE OF AUTHORIZATION NUMBERS ARE | | | REQUIRED FOR ALL FICTICIOUS BUSINESSES. | | | 7) THE FOLLOWING INFORMATION IS REQUIRED | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. (SECTION OF PIPE BETWEEN | | | THE RISE TO #7 STEAM TABLE AND #2 FIRST | | | FRYER HAS NO LENGTH SHOWN) - SUBMIT A | | | NEW SHEET WITH NEW RISER ON PLAN AND NOT | | | TAPED ON EXISTING SHEET. | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 - THE | | | MANUF. SHEET FOR THE RICE COOKER AND THE | | | WATER HEATER HAVE NOT BEEN SUBMITTED. | | | THE MANUF. SHEETS FOR THE STEAM TABLE, | | | THE SALAMANDER, & DEEP FRYERS DO NOT | | | SHOW THE BTU'S/HR REQUIRED TO VERIFY | | | PIPE SIZE. | | | F. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. - A | | | SITE PLAN FOR THIS SPACE IS REQUIRED TO | | | SHOW LOCATION AS REQUIRED. - MORE INFOR- | | | MATION THAN SUBMITTED IS REQUIRED. | | | G. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58.IF NEAR THE | | | PARKING AREA OR ROAD WAY PROTECTION OF | | | THE TANKS IS REQUIRED. SUBMIT DETAILS. | | | H. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. - NO UNION | | | IS SHOWN ON RISER DIAGRAM. | | | ********NEW COMMENT FOR GAS PERMIT****** | | | INFORMATION FOR GAS PERMIT CAN BE SUB- | | | MITTED AT TIME OF GAS PERMIT APPLICATION | | | AND CAN BE OMITTED FROM THESE PLANS IF | | | REQUESTED. - THE RISER DIAGRAM AND ALL | | | MANUF SHEETS ECT WILL BE REQUIRED WHEN | | | APPLYING FOR GAS PERMIT. OTHERWISE ALL | | | INFORMATION WILL BE REQUIRED AT TIME OF | | | RESUBMITTING PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-16 |
Time |
16:35 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-01-16 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) SHT 1 OF 4, SPECIFICATION WORKSHEETS | | | REFERED TO ON THE DEPT. OF BUSINESS REG- | | | ULATION STAMP, COMMENT #3, SHALL BE SUB- | | | MITTED WITH PLANS FOR REVIEW. SECTION | | | 104.2.1. | | | 2) AN RPZ BACKFLOW IS REQUIRED ON WATER | | | SERVICE TO SPACE. SECTION 608.13.2. | | | 3) CONTACT RODNEY COMPO, ENVIRONMENTAL | | | COMPLIANCE FOR SIZING OF GREASE INTER- | | | CEPTOR. WASTE ORD. #2938-96. (561) 837- | | | 4074. | | | 4) SHT 3 OF 4 FLOOR SINKS ARE REQUIRED | | | FOR ITEMS 9 & 10, (3 COMP. SINK & SLOP | | | SINK). HUB DRAINS ARE APPROVED FOR | | | CLEAR WATER WASTE ONLY. SECTION 802.3 | | | 5) SHT 3 OF 4 GREASE RISER DIAGRAM, A | | | VENT IS REQUIRED FOR THE MOP SINK, SECT- | | | ION 901.2.1 | | | 6) FIRM LICENSE NUMBER REQUIRED PER FAC | | | 61G1-16.004(2) & FS 481. | | | 7) FOLLOWING INFORMATION REQUIRED FOR | | | GAS PERMIT APPLICATION. | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. TYPE OF GAS, (LP OR NATURAL) | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | D. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. SHEETS | | | SHALL SHOW A LISTING FROM AN APPROVED | | | TESTING AGENCY. | | | F. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | G. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | H. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|