Plan Review Details - Permit 03120124
Plan Review Stops For Permit 03120124
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2004-11-17 Cont ID  
Sent By rmcdouga Date 2004-11-17 Time 15:02 Rev Time 0.00
Received By rmcdouga Date 2004-11-17 Time 15:00 Sent To  
Notes
2004-11-17 00:00:00SUBMITTAL FOR ROYALL INSPECTIONS IS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-11-17 Cont ID  
Sent By rmcdouga Date 2004-07-13 Time 09:02 Rev Time 0.00
Received By rmcdouga Date 2004-07-13 Time 10:38 Sent To  
Notes
2004-07-13 00:00:00SENT TO KSTEVENS DESK
2004-05-21 00:00:00BUILDING PROVISO
  
 1) SEPARATE PERMIT IS REQUIRED FOR STORM
 PANELS.
 2) INSPECTION REPORT FROM THRESHOLD
 INSPECTOR FOR ROYALL WALL SYSTEM IS
 REQUIRED BEFORE C.O.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-04-15 Cont ID  
Sent By csiegber Date 2004-05-17 Time 14:58 Rev Time 3.00
Received By rmcdouga Date 2004-04-15 Time 16:33 Sent To  
Notes
2004-04-15 00:00:00DENIED
  
 1)THE ENGINEER'S TITLE BLOCK INFORMATION
 IS ILLEGIBLE ON SOME SHEETS OF THE
 PLANS, WHERE STAMPED ON TOP OF OTHER
 INFORMATION. PLEASE CORRECT.
  
 2) FBC SECTION 2319.17 REFERENCED UNDER
 WOOD CONSTRUCTION NOTES ON SHEET 7 ONLY
 APPLIES IN THE HIGH VELOCITY HURRICANE
 ZONE. THIS DOES NOT APPLY IN THE CITY OF
 WPB WHICH IS NOT LOCATED IN THE HVHZ.
 PLEASE REMOVE THIS FROM THE PLAN.
  
 3) THE USP TA16 CONNECTOR REQUIRES (9)
 10D NAILS FOR 1205# OF UPLIFT. CORRECT
 THIS ON THE ANCHOR SCHEDULE ON RF-1.
  
 4) THE TRUSS ANCHOR SCHEDULES ON RF-1
 AND SD2 CONTAIN CONFLICTING INFORMATION.
 THE UPLIFT VALUES ARE DIFFERENT FOR THE
 SAME ID TAGS. PLEASE REMOVE ONE OF THEM
 FROM THE PLANS.
  
 5) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL FOR THE WEATHERGUARD STORM
 PANELS. SPECIFY THE CONNECTION TYPE AND
 FASTENERS THAT WILL BE USED BY CIRCLING
 OR HIGHLIGHTING THE APPROPRIATE ITEMS ON
 THE PRODUCT APPROVALS.
  
 6)PLEASE SUBMIT THE FOLLOWING ADDITIONAL
 INFORMATION REQUIRED FOR THE ROYAL WALL
 SYSTEM. SUBMIT ENGINEERING CALCULATIONS
 FOR THE PANELS. SUBMIT A LETTER FROM A
 LICENSED THRESHOLD INSPECTOR STATING
 THAT AN INSPECTION WILL BE MADE AT THE
 MANUFACTURED SITE OF THE JOB SPECIFIC
 COMPONENTS TO VERIFY CONSTRUCTION
 COMPLIANCE OF THE COMPONENTS WITH THE
 ENGINEERED DESIGN. SEE ATTACHED MEMO.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-12 Cont ID  
Sent By csiegber Date 2004-04-14 Time 10:13 Rev Time 3.00
Received By rmcdouga Date 2004-01-12 Time 13:51 Sent To  
Notes
2004-01-12 00:00:00DENIED
  
 1) THE STRUCTURAL PLANS AND THE SURVEY
 ARE REVERSED. PLEASE REVISE.
  
 2) THE NOTE ON SHEET 2 REFERS TO THE
 1997 STANDARD GAS CODE. PLEASE UPDATE TO
 2001 FBC FUEL GAS CODE.
  
 3) WINDOWS WITH THE BOTTOM EDGE WITHIN
 18" OF THE FLOOR AND INDIVIDUAL PANE
 SIZE OF AT LEAST 9 SQUARE FEET ARE
 REQUIRED TO BE SAFETY GLASS PER FBC
 2405.2.1 (4). LIVING ROOM AND DINING
 ROOM WINDOWS APPEAR TO FALL UNDER THIS
 REQUIREMENT. SPECIFY ON THE PLANS.
  
 4)A MEAN ROOF HEIGHT OF 25'-35' REQUIRES
 THE ROOF SHEATHING TO BE NAILED WITH 8D
 RING SHANKED NAILS IN ZONE 3 PER CITY
 AMENDMENTS TO FBC TABLE 2306.1. REVISE
 ROOF SHEATHING NAILING NOTE ON SHEET 4.
  
 5) UPDATE THE REFERENCES TO HUGHES
 CONNECTORS ON SHEET 3. HUGHES WAS
 PURCHASED BY USP. REFERENCE CONNECTORS
 FROM A CURRENT MANUFACTURER WITH STATE
 OF FLORIDA PRODUCT APPROVAL.
  
 6) LIST THE ENGINEER'S FIRM LICENSE
 NUMBER IN THE TITLE BLOCK ON ALL SHEETS
 SIGNED AND SEALED BY HIM. THE NUMBER
 THAT IS ON 2 OF THE SHEETS DOES NOT
 MATCH THE LICENSE # FOR PERMIT ENGINEER-
 ING SERVICES LISTED BY THE FBPE. PLEASE
 CORRECT.
  
 7) THE WOOD CONSTRUCTION NOTES ON SHEET7
 SITES FBC 3218.17. THERE IS NO SUCH CODE
 SECTION IN THE 2001 FBC. PLEASE CORRECT.
  
 8) THE USP TA16 CONNECTOR RTEQUIRES (9)
 10D NAILS PER 2003 USP CATALOG. PLEASE
 REVISE THE ANCHOR SCHEDULE ON RF-1.
  
 9) CLARIFY THE NOTE IN THE CENTER OF
 SHEET 1 OF THE ROYAL WALL SYSTEM PLANS
 FOR THE 10'-2" WALLS.
  
 10) TWO CONFLICTING UPLIFT ANCHOR
 SCHEDULES ARE GIVEN ON RF-1 AND SD2.
 PLEASE CORRECT.
  
 11) PROVIDE STATE OF FLORIDA PRODUCT
 APPROVAL OR SITE SPECIFIC LOCAL PRODUCT
 APPROVAL AS REQUIRED BY STATE LAW (SEE
 WWW.FLORIDABUILDING.ORG. AND RULE 9B-72,
 F.A.C.) FOR THE ROYAL WALL SYSTEM,
 SLIDING GLASS DOORS, SINGLE HUNG WINDOWS
 ENTRY DOOR, GARAGE DOOR, FIXED WINDOWS,
 MULLIONS, GLASS BLOCK, ROOF TILE AND
 TRUSS ANCHORS.
  
 12) SAFEGUARD IS NO LONGER IN BUSINESS.
 SUBMIT STATE PRODUCT APPROVAL FOR STORM
 PANELS, KEY PLAN AND INSTALLATION
 SCHEDULE. REVISE KEY PLAN AND SCHEDULE
 TO INDICATE IMPACT GLASS AT DEN WINDOW
 FOR EGRESS WHICH WILL NOT BE SHUTTERED.
 NOTE: DOORS TO DEN MUST NOT BE LOCKABLE.
  
 13) AFFINITI TITLE BLOCK SHOULD BE
 REMOVED FROM PLAN. THEY ARE NOT THE
 DESIGNER OF RECORD.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-12-11 Cont ID  
Sent By jleech Date 2003-12-10 Time 16:38 Rev Time 0.33
Received By dpalmer Date 2003-12-11 Time 07:31 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 11:31 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 11:31 Sent To B
Notes
2004-11-12 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-17 Cont ID  
Sent By csiegber Date 2004-05-17 Time 14:58 Rev Time 0.00
Received By csiegber Date 2004-05-17 Time 14:58 Sent To B
Notes
2004-05-17 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 10:13 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 10:13 Sent To B
Notes
2004-04-14 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-12 Cont ID  
Sent By mmclean Date 2003-12-04 Time 12:16 Rev Time 0.00
Received By rmcdouga Date 2003-12-02 Time 13:53 Sent To  
Notes
2003-12-04 00:00:00TO SFD RACK/E
2003-12-02 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-12-16 Cont ID  
Sent By dpalmer Date 2003-12-11 Time 07:31 Rev Time 0.50
Received By rregueir Date 2003-12-16 Time 17:31 Sent To B
Notes
2003-12-16 00:00:00PROVISO:
 ATTIC ACCESS OPENING SHALL BE NO LESS
 THAN 30" X 22" AS PER 2001 FBC(M) 306.3
  
 2001 FBC CHAPTER 13 610.1.ABC.3.5.2 -
 1. THE SERVICE PANEL OF THE EQUIPMENT IS
 LOCATED WITHIN 6 FT OF AN ATTIC
 ACCESS.
 2. A DEVICE IS INSTALLED TO ALERT THE
 OWNER OR SHUT DOWN WHEN THE
 CONDENSATE DRAIN IS NOT WORKING
 PROPERLY.
 4. A NOTICE IS POSTED ON THE ELECTRIC
 SERVICE PANEL INDICATING TO THE
 HOMEOWNER THAT THE AIR HANDLER IS
 LOCATED IN THE ATTIC.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-07-20 Cont ID  
Sent By jleech Date 2004-07-20 Time 17:31 Rev Time 0.33
Received By jleech Date 2004-07-20 Time 17:31 Sent To  
Notes
2004-07-20 00:00:00REVISED RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-21 Cont ID  
Sent By rmcdouga Date 2004-05-21 Time 11:02 Rev Time 0.00
Received By rmcdouga Date 2004-05-21 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-10 Cont ID  
Sent By jleech Date 2003-12-10 Time 16:38 Rev Time 0.33
Received By jleech Date 2003-12-10 Time 16:38 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-04 Cont ID  
Sent By csiegber Date 2003-12-02 Time 13:53 Rev Time 0.00
Received By mmclean Date 2003-12-04 Time 12:15 Sent To I
Notes
***NONE***