Plan Review Details - Permit 03111176
Plan Review Stops For Permit 03111176
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-29 Cont ID  
Sent By rmcdouga Date 2004-01-29 Time 15:26 Rev Time 2.00
Received By rmcdouga Date 2004-01-29 Time 15:25 Sent To  
Notes
2004-01-29 00:00:00BUILDING PROVISO
  
 1) SUBMIT SOIL BORING TEST REPORT PRIOR
 TO POURING THE FOUNDATION.
  
 2) SUBMIT PRODUCT APPROVALS FOR THE
 FOLLOWING:
 - OVERHEAD GARAGE DOOR
 - DOUBLE OUTSWING ENTRY DOOR
 - SINGLE OUTSWING GLAZED DOOR (WITHOUT
 SIDELITES)

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-17 Cont ID  
Sent By hmoser Date 2004-01-28 Time 15:44 Rev Time 2.50
Received By rmcdouga Date 2003-12-17 Time 10:11 Sent To  
Notes
2003-12-17 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) FBC* 1804.2.2AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 4) SAFETY GLAZING IS REQUIRED WITHIN
 3' HORIZONTALLY OF A TUB OR SHOWER PER
 FBC 2405.2. SPECIFY ON THE PLANS THAT
 WINDOW (U) BESIDE THE TUB IN THE SECOND
 FLOOR BATH #2 IS TEMPERED.
  
 5) SPECIFY THE FASTENERS (LENGTH/EMBED)
 FOR ATTACHING THE TRUSS BUCKETS TO THE
 WALL. SEE SHEET A7.
  
 6) INDICATE ON THE COLUMN BASE DETAILS
 ON A7 TO REFER TO THE DETAIL ON A13 FOR
 ANCHORING DETAIL.
  
 7) FBC 1015.3 REQUIRES THE BOTTOM RAIL
 ON A GUARDRAIL TO REJECT A 2" SPHERE.
 PLEASE CORRECT THE RAILING DETAIL ON A12
  
 8) THE WALL SECTIONS ON A12 SPECIFY A
 ATTIC INSULATION WITH A MINIMUM OF R-30
 AND THE ENERGY CALCS. LISTS R-19.
 PLEASE CORRECT.
  
 9) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL PER FAC
 RULE 9B-72. SEE FORM ATTACHED.
  
 10) THE DESIGN PRESSURES ON THE PRODUCT
 APPROVAL FOR THE OVERHEAD GARAGE DOOR
 DOES NOT MEET THE PRESSURES LISTED ON
 THE PLANS.
  
 11) THE PRODUCT APPROVAL SUBMITTED FOR
 THE GLAZED EXTERIOR DOOR IS FOR A DOOR
 WITH SIDELITES, THE DOOR ON THE PLANS
 DOES NOT HAVE SIDELITES. SUBMIT THE
 APPROPRIATE PRODUCT APPROVAL. NOTE THE
 ONE SUBMITTED DOES NOT MEET THE REQUIRED
 PRESSURES LISTED IN THE SCHEDULE ON A1.
  
 12) THE KEY PLAN AND SCHEDULE SUBMITTED
 FOR THE STORM PANELS DOES NOT MATCH THE
 PLANS (SECOND FLOOR). SUBMIT REVISED
 KEY AND SCHEDULE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-08-03 Cont ID  
Sent By dpalmer Date 2004-08-03 Time 12:07 Rev Time 0.25
Received By dpalmer Date 2004-08-03 Time 12:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-06-09 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:22 Rev Time 0.33
Received By dpalmer Date 2004-06-09 Time 12:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-27 Cont ID  
Sent By csiegber Date 2004-06-04 Time 16:46 Rev Time 0.33
Received By dpalmer Date 2004-04-27 Time 18:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-03-27 Cont ID  
Sent By csiegber Date 2004-04-26 Time 09:23 Rev Time 0.50
Received By btrobaug Date 2004-03-27 Time 06:29 Sent To  
Notes
2004-03-27 00:00:00 
 THE REVISION SUBMITED REFERS TO A "60
 AMP SUB PANEL FOR THE SECOND FLOOR",BUT
 THE ADDED 60 AMP PANEL ON THE PLAN HAS
 POOL CIRCUITS ON ITS SCHEDULE.
  
 THERE ARE FOUR ITEMS ON THE LIST
 SUBMITTED WITH THIS REVISION THAT REFER
 TO ITEMS ON THE SECOND FLOOR, BUT NO
 SECOND FLOOR DRAWING WAS SUBMITTED FOR
 REVIEW.
  
 PLEASE CLARIFY THESE ITEMS AND REMOVE
 COMMENTS OR ADD SHEETS AS NECESSARY.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-12-09 Cont ID  
Sent By csiegber Date 2004-03-19 Time 10:30 Rev Time 0.50
Received By dpalmer Date 2003-12-09 Time 07:11 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:22 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 08:22 Sent To E
Notes
2004-07-29 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-04 Cont ID  
Sent By csiegber Date 2004-06-04 Time 16:46 Rev Time 0.00
Received By csiegber Date 2004-06-04 Time 16:46 Sent To E
Notes
2004-06-04 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-04-26 Time 09:23 Rev Time 0.00
Received By csiegber Date 2004-04-26 Time 09:23 Sent To E
Notes
2004-04-26 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-19 Cont ID  
Sent By csiegber Date 2004-03-19 Time 10:30 Rev Time 0.00
Received By csiegber Date 2004-03-19 Time 10:30 Sent To E
Notes
2004-03-19 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-22 Cont ID  
Sent By csiegber Date 2004-01-22 Time 16:28 Rev Time 0.00
Received By csiegber Date 2004-01-22 Time 16:27 Sent To M
Notes
2004-01-22 00:00:00TO PK DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-17 Cont ID  
Sent By mmclean Date 2004-05-05 Time 16:13 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 12:36 Sent To  
Notes
2003-12-04 00:00:0011/26/03TO Z
 12/4/03TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-28 Cont ID  
Sent By hmoser Date 2004-01-28 Time 15:34 Rev Time 0.50
Received By hmoser Date 2004-01-28 Time 15:22 Sent To B
Notes
2004-01-28 00:00:00PASS PRIVISO
 1)REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6734

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-28 Cont ID  
Sent By csiegber Date 2004-01-22 Time 16:28 Rev Time 0.50
Received By hmoser Date 2003-12-10 Time 19:18 Sent To B
Notes
2003-12-10 00:00:00PLAN DENIED
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-13 Cont ID  
Sent By jleech Date 2003-12-13 Time 05:50 Rev Time 0.33
Received By jleech Date 2003-12-13 Time 05:50 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-03 Cont ID  
Sent By csiegber Date 2003-11-26 Time 15:53 Rev Time 0.00
Received By mmclean Date 2003-12-03 Time 09:24 Sent To I
Notes
***NONE***