| Plan Review Stops For Permit 03111168 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-02-09 |
Time |
08:37 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-02-09 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-05 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-12-24 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2003-12-24 00:00:00 | BUILDING PLAN REVIEW: | | | | | | 1.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | A SAMPLE OF A PRODUCT APPROVAL IS | | | ATTACHED FOR THE BENCHMARK EXTERIOR | | | DOORS. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AND A COPY SUBMITTED BEFORE A | | | PERMIT CAN BE PICKED UP. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-17 |
Time |
13:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-17 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-03 |
Time |
15:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
11:31 |
Sent To |
E |
|
| Notes |
| 2004-03-11 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-23 |
Time |
14:30 |
Sent To |
M |
|
| Notes |
| 2004-01-23 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-12 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-12 |
Time |
09:17 |
Sent To |
M |
|
| Notes |
| 2004-01-12 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-25 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-21 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2003-11-26 00:00:00 | TO SFD RACK/E | | 2003-11-21 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-05 |
Time |
15:15 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-02-05 |
Time |
15:15 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
14:30 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-01-16 |
Time |
07:55 |
Sent To |
B |
|
| Notes |
| 2004-01-16 00:00:00 | DENIED: | | | MECHANICAL FLOOR PLAN (1ST FLOOR) DOES | | | NOT MATCH THE BUILDING FLOOR PLAN. | | | PLEASE REVISE PLANS TO REFLECT THE | | | BUILDING FLOOR PLAN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-12 |
Time |
09:17 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-12-10 |
Time |
17:36 |
Sent To |
B |
|
| Notes |
| 2003-12-10 00:00:00 | PLAN DENIED | | | 1) REFER TO SECTION 307.2.3 AUXILIARY | | | DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE | | | INSTALLED UNDER ALL COILS ON WITCH | | | CONDENSATION WILL OCCUR. | | | 2) RETURN AIR REQUIREMENTS TO COMPLY | | | WITH THE FLORIDA BUILDING CODE (M) 2003 | | | CHANGES.CHANGES WENT INTO EFFECT JULY 1 | | | 2003 | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-12-06 |
Time |
09:05 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-12-06 |
Time |
09:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-11-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-25 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-11-25 |
Time |
14:51 |
Sent To |
I |
|
| Notes |
|
|