| Plan Review Stops For Permit 03111139 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-05-28 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-05-28 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | ADDITIONAL RATIONAL ANALYSIS REVIEWED. | | | REQUIREMENT FOR STRUCTURAL MULLION RED- | | | LINED. | | 2004-05-28 00:00:00 | BUILDING PLAN REVIEW | | | ***REVISION DENIED*** | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED 5/26/04 PROPOSING | | | ALTERNATIVE STOREFRONT AND DOOR PRODUCTS | | | | | | 1) KAWNEER STOREFRONT PRODUCT APPROVAL, | | | FL627.DRAWING SHEET 1 OF THE MIAMI- | | | DADE PRODUCT APPROVAL NOA #02-0220.01 | | | SHOWS A MAXIMUM FRAME HEIGHT OF 114" | | | WHICH IS LESS THAN THE 131" PROPOSED ON | | | THOMAS TWOMEY, P.E. DRAWING SHEET 2. | | | SUBMIT A PRODUCT APPROVAL FOR AN | | | APPROPRIATE HORIZONTAL MULLION. | | | | | | 2) KAWNEER STOREFRONT PRODUCT APPROVAL, | | | FL627.DRAWING SHEET 1 OF THE MIAMI- | | | DADE PRODUCT APPROVAL NOA #02-0220.01 | | | SHOWS A MAXIMUM PANEL WIDTH OF 48" WHICH | | | IS LESS THAN THE 55" WIDTH OF WINDOW | | | TYPES D AND E PROPOSED ON THOMAS | | | TWOMEY, P.E. DRAWING SHEET 2.THAT 48" | | | WIDTH COMBINED WITH THE SPECIFIED 96" | | | HEIGHT IS ALSO OUTSIDE THE SCOPE OF THE | | | SUBMITTED RATIONAL ANALYSIS CALCULATION. | | | SUBMIT ALTERNATIVE PRODUCT APPROVAL. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-02-24 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2004-02-24 00:00:00 | SITE-SPECIFIC AND LOCAL PRODUCT APPROVAL | | | DOCUMENTATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-02-12 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-02-12 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2004-02-12 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | A) MODIFIED BITUMEN ROOF SYSTEM. PAGE 15 | | | OF THE SUBMITTED MIAMI-DADE PRODUCT | | | APPROVAL NOA# 01-0524.13 STATES THAT THE | | | MAXIMUM DESIGN PRESSURE IS -45 PSF AND | | | REFERS TO GENERAL LIMITATION #9 | | | (PAGE 23) WHICH DOES NOT PERMIT RATIONAL | | | ANALYSIS OR EXTRAPOLATION FOR ENHANCED | | | FASTENINGS AT PERIMETERS AND CORNERS. | | | THE UPLIFT PRESSURES ON THE ROOF FRAMING | | | PLAN (SHEET S-2.0) EXCEED THE MAX DESIGN | | | PRESSURE.SUBMIT A PRODUCT APPROVAL FOR | | | A ROOFING SYSTEM WITH SUFFICIENT UPLIFT | | | CAPACITY.NOTE THAT THE ROOFING SYSTEM | | | IS REQUIRED BE CLASS A OR B AS THE | | | BUILDING IS IN THE FIRE DISTRICT. | | | | | | B) BARREL ALHAMBRA CLAY TILE.FROM THE | | | SUBMITTED MIAMI-DADE PRODUCT APPROVAL | | | NOA# 02-0603.04 IT IS NOTED THAT THE | | | PROPOSED TILE REQUIRES ADHESIVE SET OR | | | MORTAR SET ATTACHMENT.THEREFOR THE | | | UNDERLAYMENT WILL BE REQUIRED TO RESIST | | | THE UPLIFT PRESSURES STATED ON THE ROOF | | | FRAMING PLAN (SHEET S-2.0).SEE COMMENT | | | (A) ABOVE. | | | | | | C) ALUMINUM STOREFRONT.THE SUBMITTED | | | MIAMI-DADE PRODUCT APPROVALS | | | NOA# 02-1011.03 AND 02-1011.04 WERE | | | MISSING DRAWING SHEETS 1 TO 8 AND 1 TO 6 | | | RESPECTIVELY, THESE HAVE BEEN PRINTED | | | FROM THE MIAMI-DADE WEBSITE AT | | | WWW.MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH | | | _APP.ASP AND INSERTED.BY REFERING TO | | | DRAWING SHEET 1 IT IS NOTED THAT THE | | | ROUGH OPENING HEIGHTS AT DOOR TYPES I, | | | IV, V AND VI ALL EXCEED THE MAXIMUM | | | HEIGHT ALLOWED BY THE PRODUCT APPROVAL. | | | ALSO, THE WIDTHS OF WINDOW TYPES B, C, | | | D AND E ALL EXCEED THE MAXIMUM WIDTH | | | (VERTICAL MULLION SPACING) ALLOWED BY | | | THE PRODUCT APPROVAL.SUBMIT A PRODUCT | | | APPROVAL FOR A STOREFRONT/FIXED WINDOW | | | SYSTEM THAT IS APPLICABLE TO THE OPENING | | | SIZES PROPOSED. | | | | | | D) HOLLOW METAL DOORS AND FRAMES.THE | | | DOCUMENT SUBMITTED FOR PRODUCT APPROVAL | | | APPEARS TO BE A CECO DOOR PRODUCTS | | | DOCUMENT BEING USED TO CERTIFY DOORS | | | MANUFACTURED BY CECO DOOR PRODUCTS. | | | FL. ADMIN CODE RULE 9B-72 REQUIRES THAT | | | AN APPLICATION FOR PRODUCT APPROVAL | | | INCLUDE THE NAME, ADDRESS, REPORTS AND | | | REPORT NUMBERS OF THE TESTING ENTITY, | | | THE EVALUATION ENTITY OR THE | | | CERTIFICATION ENTITY.THAT INFORMATION/ | | | DOCUMENTATION HAS NOT BEEN PROVIDED. | | | | | | NOTE: | | | | | | THE PRODUCT APPROVAL SHEETS SHALL BE | | | MARKED, AS APPROPRIATE, TO IDENTIFY | | | WHICH PRODUCT OPTIONS/MATERIALS/SIZES | | | ARE TO BE USED. | | | | | | FOR PRODUCTS WHICH DO NOT HAVE STATEWIDE | | | PRODUCT APPROVAL, LOCAL PRODUCT APPROVAL | | | CAN BE ACHIEVED IF THERE IS A QUALITY | | | ASSURANCE PROGRAM IN PLACE WITH A STATE | | | APPROVED QUALITY ASSURANCE ENTITY.IF | | | NEITHER IS APPLICABLE, THEN SITE | | | SPECIFIC APPROVAL IS REQUIRED.LOCAL | | | PRODUCT APPROVAL WILL ALLOW A PRODUCT TO | | | BE USED, IN ACCORDANCE WITH THE TEST | | | CRITERIA, THROUGHT THE JURISDICTION OF | | | WEST PALM BEACH.SITE SPECIFIC PRODUCT | | | APPROVAL WILL ALLOW A PRODUCT TO BE | | | USED ONLY ON THE PROJECT FOR WHICH THAT | | | SITE SPECIFIC APPROVAL IS GRANTED. | | | LOCAL AND SITE SPECIFIC PRODUCT APPROVAL | | | APPLICATION FORMS ARE AVAILABLE FROM | | | THIS OFFICE.APPROVED QUALITY ASSURANCE | | | ENTITIES ARE LISTED ON THE DCA WEBSITE: | | | WWW.FLORIDABUILDING.ORG/COMMON/C_ORG_ | | | REGI_SRCH.ASP | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-02-05 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-02-05 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | IMPACT FEES.SUBMITTAL OF AN ESTIMATE, | | | FROM PALM BEACH COUNTY, OF IMPACT FEES | | | DUE, IS NOTED. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | FBC 13-103.1.2SHEET 2 OF THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | FL ADMIN CODE RULE 9B-72. PRODUCT APPR. | | | A SEARCH AT THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | SHOWS NO MATCHING STATEWIDE PRODUCT | | | APPROVAL FOR THE 'U.S. ALUMINUM CORP.' | | | STOREFRONT (NOA# 02-1011.04)) OR THE | | | 'STEELCRAFT' HOLLOW METAL DOOR (NOA# | | | 01-0129.12) THAT HAVE BEEN REFERENCED ON | | | SHEET A-6.0. | | | SPECIFY AN ALTERNATIVE THAT HAS | | | STATEWIDE OR LOCAL PRODUCT APPROVAL. | | | THE PRODUCT APPROVAL SHEETS SHALL BE | | | MARKED, AS APPROPRIATE, TO IDENTIFY | | | WHICH PRODUCT OPTIONS/MATERIALS/SIZES | | | ARE TO BE USED. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-05 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-05 |
Time |
16:14 |
Sent To |
Z |
|
| Notes |
| 2004-01-05 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) THE SUBMITTED SITE SURVEY STATES THE | | | PROPERTY ADDRESS AS 5709 S. DIXIE HWY. | | | AMEND TO 5705 S. DIXIE HWY. | | | | | | 3) THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.SUBMIT A COPY OF THE 'UNITY | | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | | | | 4) FBC 11-4.6.3SHEET A-1.0RAMPS FROM | | | ACCESSIBLE PARKING TO SIDEWALK.CURB | | | RAMPS MUST BE LOCATED OUTSIDE OF THE | | | PARKING ACCESS AISLE.THE RAMP AS SHOWN | | | ENCROACHES ON THE 5' WIDE PARKING ACCESS | | | AISLE.AMEND THE PLAN. | | | | | | 5) FBC 13-101.1.6SHELL BUILDINGS. | | | THE WHOLE BUILDING (INCL. FUTURE TENANT | | | SPACE) SHALL BE CONSIDERED.SHELL | | | BUILDINGS SHALL BE SHOWN TO COMPLY WITH | | | METHOD B (SEE SUB-CHAPTER 4).ALL | | | ASSUMPTIONS MADE ABOUT SYSTEMS, NOT | | | SHOWN ON THE CURRENT PLANS, SHALL BE | | | LISTED AND APPENDED TO THE FORM 400B FOR | | | SUBMITTAL.THIS WILL BE COMPARED TO THE | | | ACTUAL SYSTEMS PROPOSED, AT A LATER, FOR | | | INSTALLATION BY THE TENANT(S).THE | | | ASSUMPTIONS LISTED ON THE APPENDIX SHEET | | | SHALL BE AT LEAST THE MINIMUM STANDARD | | | (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE | | | BUILDING TO BE OCCUPIED FOR IT'S | | | INTENDED PURPOSE. | | | | | | 6) FBC 13-103.1.2THE SUBMITTED ENERGY | | | CODE COMPLIANCE FORMS WERE NOT SIGNED | | | BY EITHER THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | ALSO THE ARCHITECT'S REGISTRATION NUMBER | | | WAS NOT ENTERED ON SHEET TWO.ADDRESS | | | THESE ITEMS TOGETHER WITH COMMENT 5. | | | | | | 7) FBC 1403.3MASONRY VENEER.ANNOTATE | | | THE PLANS GIVE THE SPECIFICATION FOR | | | ATTACHMENT OF THE MASONRY VENEER. | | | | | | 8) FBC 2309.7ATTIC VENTILATION. | | | SHEET A-5.0, SECTION 1.ATTIC SPACE | | | SHALL BE VENTILATED. AMEND THE "UNVENTED | | | ATTIC" ANNOTATION ON SECTION 1. | | | | | | 9) SHEET S-2.2, DETAIL 10, TYPICAL WALL | | | SECTION AT ROOF EAVES.THE STATED | | | 1515 LB UPLIFT CAPACITY OF THE HETAL 16 | | | TRUSS ANCHOR EXCEEDS THE UPLIFT GIVEN IN | | | THE 2003 SIMPSON CATALOGUE FOR 1-PLY | | | TRUSS APPLICATION.AMEND THE DETAIL. | | | | | | 10) SHEET S-2.2, DETAIL 12, GIRDER TRUSS | | | CONNECTION TO STEEL BEAM.THE STATED | | | 2310 LB UPLIFT CAPACITY OF THE LTTI31 | | | TENSION TIE EXCEEDS THE UPLIFT GIVEN IN | | | THE 2003 SIMPSON CATALOGUE.AMEND THE | | | DETAIL. | | | | | | 11) FBC 704.3SHEET S-2.2, DETAILS 4, 6 | | | AND 7.SUBMIT JUSTIFICATION (UL LISTING | | | OR EQUIVALENT) FOR THE PROPOSED USE OF | | | 2X8 FIRE TREATED PLATE IN THE TENANT | | | FIRE SEPARATION WALL OR AMEND THE DETAIL | | | | | | 12) FBC 1606.1.7WIND LOAD.THE PLANS | | | SHALL STATE EXTERIOR COMPONENT AND | | | CLADDING DESIGN WIND PRESSURES FOR THE | | | DOORS AND WINDOWS AND FOR THE ROOF. | | | | | | 13) FBC* 2306.1ROOF SHEATHING NAIL | | | SPACING.AMEND THE PLANS TO SPECIFY | | | THE FASTENER TYPE AND SPACING. | | | | | | 14) SUBMIT PRODUCT APPROVALS FOR THE | | | WINDOWS, EXTERIOR DOORS AND ROOF. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-26 |
Time |
15:57 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-26 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-04 |
Time |
11:04 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-12-04 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2003-12-04 00:00:00 | ******** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SIGN PLANS WITH A MIN | | | SIGNATURE CONATINING FIRST AND LAST NAME | | | AS SIGNED WITH THE FBPE'S. | | | THIS OFFICE HAS RECEIVED NOTICE AND HAS | | | BEEN DIRECTED FROM THE STATE BORAD OF | | | PE`S THAT INITIALS ARE NOT ACCEPTABLE. | | | PLANS ARE REQ'D TO BE SIGNED. | | | | | | | | | PLEASE SEE THAT THIS IS THE ONLY COMMENT | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2004-02-10 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-02-10 |
Time |
09:40 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-02-10 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2004-02-10 00:00:00 | PASSED WITH PROVISOS: | | | 1. THE APPLICANT (G.C.) TO COMPLY WITH | | | REVIEW COMMENTS BY PUBLIC UTILITIES & | | | ENGINEERING SERVICES, SHEET 1 OF 3. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-05 |
Time |
12:27 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-01-26 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2004-01-26 00:00:00 | FAILED: | | | 1. PLEASE NOTE THAT ONLY ONE SET OF | | | CIVIL PLANS IS PROVIDED, BOTH SETS OF | | | PERMIT PLANS SHOULD HAVE CIVIL INCLUDED. | | | 2. PLEASE INCLUDE POLLUTION/EROSION | | | CONTROL DESIGN IN CIVIL PLAN, IT MUST BE | | | INSTALLED IN FIELD PRIOR TO ANY EARTH- | | | WORK. | | | 3. ALL OFF STREET PARKING STALLS MUST BE | | | PAINTED WITH DOUBLE 4" WIDE STRIPES PER | | | CITY REQUIREMENTS. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-01-06 |
Time |
13:42 |
Rev Time |
5.00 |
| Received By |
mamini |
Date |
2004-01-06 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2004-01-06 00:00:00 | FAILED: | | | 1. PLEASE SUBMIT CIVIL PLANS FOR OUR | | | REVIEW AND APPROVAL, PLANS MUST INCLUDE | | | DRAINAGE SYS AND MUST BE DESIGNED PER | | | CITY OF WPB CRITERIA AND REQUIREMENTS. | | | 2. PLEASE SUBMIT CIVIL PLANS TO THE | | | PUBLIC UTILITIES AND ENGINEERING FOR ALL | | | THE CONNECTION TO CITY SERVICES AND FOR | | | THE LOCATION OF METER, BACKFLOWS, ETC. | | | ATT; MANNY GONZALEZ 659-8040, PLANS MUST | | | BE STAMPED PRIOR TO SUBMITTING TO | | | COSTRUCTION SERVICES FOR PERMITTING. | | | 3. PLEASE INCLUDE PERVIOUS AND | | | IMPERVIOUS AREA IN DRANAGE CALCULATION | | | FOR THE ENTIRE SITE. | | | 4. PLEASE INCLUDE POLLUTION PREVENTION | | | PLANS, PLANS MUST INSTALLED IN FIELD | | | PRIOR TO ANY CONSTRUCTION/ EARTH WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-22 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-22 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-08 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-08 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2003-12-08 00:00:00 | 1) FIRE LIMITS CERTAIN RESTRICTIONS WILL | | | APPLY. ALL WOOD SHALL BE FIRE | | | RETARDANT. | | | | | | 2) BATHROOM DOOR IN SPACE # 2 OPENS | | | INTO AN AREA THAT DOES NOT ALLOW THE | | | REQUIRED 44" AISLE. SPACE # 7 IS ALSO | | | THE SAME. | | | | | | 3) PLEASE INDICATE EXIT DISCHARGE. | | | EXIT DISCHARGE SHALL BE AT LEAST | | | TEN FEET HIGH, TEN FEET WIDE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-15 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-15 |
Time |
16:36 |
Sent To |
P |
|
| Notes |
| 2004-10-15 00:00:00 | TO KS DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-24 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-24 |
Time |
15:53 |
Sent To |
P |
|
| Notes |
| 2004-08-24 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-08-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-06 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-06 |
Time |
15:49 |
Sent To |
P |
|
| Notes |
| 2004-08-06 00:00:00 | TO KS BOX/SUBMITTAL - PROVISO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-27 |
Time |
09:24 |
Sent To |
B |
|
| Notes |
| 2004-05-27 00:00:00 | TO RB DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-05 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-05 |
Time |
12:27 |
Sent To |
ENG |
|
| Notes |
| 2004-02-05 00:00:00 | SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-21 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-21 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2004-01-21 00:00:00 | TO COMM BD#32 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-09 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-21 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-11-21 00:00:00 | TO COMM BD#43 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-02 |
Time |
08:29 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-02-02 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2004-02-02 00:00:00 | PROVISO: | | | CONDENSING UNIT STANDS SHALL COMPLY WITH | | | 2001 FBC 1511.7 FOR MINIMUM HEIGHT | | | REQUIREMENT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-09 |
Time |
14:03 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-12-09 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2003-12-09 00:00:00 | PROVISO: PERMIT IS FOR THE SHELL ONLY | | | | | | PLEASE NOTE, PLAN SHEET M-1 DETAIL C.U. | | | SUPPORT DETAIL INDICATES 18". 18" SHALL | | | BE FROM THE ROOF SURFACE TO THE BOTTOM | | | OF THE SUPPORT RAIL. | | | | | | FRESH AIR INTAKES SHALL BE A MINIMUM OF | | | 10 FT FROM EXHAUST. | | | | | | PLEASE PROVIDE EQUIPMENT SCHEDULE & O.A | | | AND ENERGY CALCULATIONS WITH PERMIT | | | APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-15 |
Time |
18:04 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-15 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2004-10-15 00:00:00 | REVISION APPROVED | | | | | | CHANGED MATERIAL OF COLLECTOR HEAD AND | | | DOWNSPOUT OF ROOF DRAIN FROM COPPER TO | | | ALUMINIUM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-15 |
Time |
16:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-07 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2004-10-07 00:00:00 | REVISION OK - DELETED AUTOMATIC FILL FOR | | | FOUNTAIN - ADDED DRAIN TO FOUNTAIN - | | | SHEETS SK-1, SK-2, SK-3. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2004-09-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-18 |
Time |
07:59 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-09-18 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2004-09-18 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATUTES | | | | | | THE ENGINEER OF RECORD SHALL SIGN AND | | | SEAL ALL REVISIONS TO A SIGNED AND SEAL- | | | ED SET OF PLANS THAT WERE PREPARED BY | | | THE ENGINEER OF RECORD. | | | | | | THE ARCHITECT SHALL NOT SIGN AND SEAL | | | DRAWINGS WHICH WERE NOT PREPARED BY THE | | | ARCHITECT. FS 481.221(4) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-24 |
Time |
15:53 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-08-16 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2004-08-16 00:00:00 | SUBMITTALS APPROVED FOR FOUNTAIN. - THE | | | REVISIONS FOR SANT. AND WATER HAVE BEEN | | | DENIED. REVISIONS TO A SIGNED/SEALED SET | | | OF PLANS SHALL SIGNED/SEALED/DATED BY | | | THE ARCH./ENG. OF RECORD. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-06 |
Time |
15:49 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-02-24 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2004-02-24 00:00:00 | PASSED/PROVISO | | | | | | FOUNTAIN SHALL DRAIN TO SANITARY. | | | PROVIDE A REVISION SHOWING PIPING FOR | | | FOUNTAIN DRAIN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-17 |
Time |
08:57 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-26 |
Time |
18:54 |
Sent To |
|
|
| Notes |
| 2004-01-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | | | | 1) WATER SUPPLY TO FOUNTAIN REQUIRES | | | BACKFLOW PROTECTION. 608.13.2 | | | 2) FOUNTAIN REQUIRES A DRAIN AND OVER- | | | FLOW. SUBMIT DETAILS - DRAIN TO SANITARY | | | AND OVERFLOW TO STORM OR DRYWELL | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-13 |
Time |
14:55 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-12-13 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2003-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) PROVIDE INFORMATION AND DETAIL FOR | | | UPPER ROOFS ON SHT A1.0 SHOWING PRIMARY | | | AND SECONDARY ROOF DRAINS, ROOF SIZE | | | AND 1/2 AREA OF PARAPET WALLS, DRAIN | | | SIZE ECT. SECTIONS 1106, AND 1107 AND | | | ALL SUBSECTIONS. | | | 2) 3" SECONDARY DRAIN SHOWN ON SHT A1.0 | | | ARE NOT ACCEPTABLE. SECTION 1107.3 - | | | MINIMUM OPENING FOR OVERFLOW SCUPPERS | | | SHALL BE 3 TIMES THE CROSS SECTIONAL | | | AREA OF PRIMARY DRAINS. (22"). THE | | | OVERFLOW SCUPPER WILL HAVE TO BE A | | | MINIMUM OF 6", OR A 6X4 RETANGLE. | | | 3) SEPARATE PLANS/PERMIT REQUIRED FOR | | | FOUNTAIN. SHOW WATER SUPPLY, DRAIN, AND | | | OVERFLOW LINES FOR FOUNTAIN. 104.2.1 | | | 4) ENGINEER'S SIGNATURE REQUIRED ON SEAL | | | PER FAC 61G15-23.002(1) & FS 471.025 | | | INITALS ON ACCEPTABLE PER FBPE & BLDG. | | | OFFICIAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-05 |
Time |
17:43 |
Rev Time |
0.50 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | MONUMENT SIGN NOT APPROVED AS PART OF TH | | | IS PERMIT. | | | CITY COMMISSION MUST DESIGNATE ALLEY AS | | | ONE-WAY OR ACCESS EASEMENT SHALL BE PROV | | | IDED PRIOR TO C.O. |
|
|