| Plan Review Stops For Permit 03111103 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-22 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-22 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-01-21 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-23 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2) FBC 704 & FBC 705WALL AND DOOR FIRE | | | RESISTANCE.SHEET A.2.THE WALLS AT | | | DOORS 01, 27 AND 31 SHALL BE 1-HOUR | | | FIRE-RESISTANT. AMEND THE LEGEND.ALSO, | | | DOORS 01, 27 AND 31 (AND DOOR 26) ARE | | | NOT SHOWN ON THE DOOR SCHEDULE | | | (SHEET A-11) AS FIRE-RATED.AMEND THE | | | DOOR SCHEDULE. | | | | | | 3) FBC 2405.2SAFETY GLAZING. REFERENCE | | | NOTE K, ON SHEET A-11, SPECIFYING | | | TEMPERED GLASS IN DOORS, SIDELIGHTS AND | | | VISION PANELS IS NOTED.THE GLAZING IN | | | THE SEMINAR AND CONFERENCE ROOM WALLS IS | | | ALSO IN A 'HAZARDOUS LOCATION' AND IS | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 4) FBC 11-4.24.3PANTRY SINK | | | ACCESSIBILTY.SHEET A-8, ELEVATION 6 | | | AND SHEET A-10, SECTION 1.KNEE | | | CLEARANCE THAT IS AT LEAST 27" HIGH, | | | 30" WIDE AND 19" DEEP SHALL BE PROVIDED | | | UNDERNEATH THE SINK.AMEND THE PLANS. | | | | | | 5) FBC 11-4.13.6MANEUVERING CLEARANCES | | | AT DOOR 27. ANNOTATE SHEET A-2 TO ENSURE | | | 18" CLEARANCE BETWEEN THE STRIKE EDGE OF | | | THE DOOR AND THE ADJACENT WALL, ON THE | | | PULL-SIDE OF THE DOOR. | | | | | | 6) FBC 11.4.1.3(10)DRINKING FOUNTAIN. | | | DOES THE PROPOSED WORK AFFECT THE | | | DRINKING FOUNTAIN PROVISION FOR THIS | | | FLOOR?AMEND THE PLAND TO SHOW THE | | | LOCATION OF THE DRINKING FOUNTAIN(S). | | | IF A NEW DRINKING FOUNTAIN IS TO BE | | | PROVIDED, SUBMIT DETAILD TO DEMONSTRATE | | | COMPLIANCE WITH FBC 11-4.15. | | | | | | 7 ) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-26 |
Time |
15:47 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-26 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
15:26 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-01-09 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2004-01-09 00:00:00 | ******** UNSAT ******* | | | | | | 1)NOTE: PLEASE SEE E4.1, FA 0.1,2.1 | | | NEEDS SIGNATURE. | | | PLEASE SIGN BOTH SETS. | | | 471.025/61G15-23.002 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2003-11-26 |
Time |
10:56 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2003-11-26 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-29 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-29 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-09 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-09 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2004-01-09 00:00:00 | APPROVED PROVISO: | | | | | | FIRE ALARM NOTES # 17 IS STILL | | | INCORRECT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-08 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-08 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2003-12-08 00:00:00 | 1) FIRE ALARM NOTES # 17 IS INCORRECT. | | | FIRE ALARM CIRCUITS SHALL BE CLASS A, | | | STYLE D, NOT CLASS B, STYLE C. | | | | | | 2) ANY CHANGES TO FIRE SPRINKLER | | | SYSTEM. SEPARATE PLANS AND PERMITS. | | | | | | 3) DOORS IN RECEPTION SWING IN. WHY | | | DONT THEY SWING OUT DUE TO OCCUPANT | | | LOAD. | | | | | | 4) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-23 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2004-01-23 00:00:00 | TO COMM BD#39 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-08 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-08 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | TO COMM BD#56 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-30 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-24 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2003-11-24 00:00:00 | TO COMM BD#51 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-29 |
Time |
08:09 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-01-29 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-01-21 |
Time |
16:29 |
Rev Time |
1.00 |
| Received By |
hmoser |
Date |
2004-01-21 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2004-01-21 00:00:00 | PASS PRIVISO | | | REFER TO SECTION 307.2.4 SECONDARY DRAIN | | | SYSTEM.WHERE AN AUXILIARY DRAIN CANNOT | | | BE INSTALLED UNDER UNITS. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-15 |
Time |
07:54 |
Rev Time |
0.55 |
| Received By |
hmoser |
Date |
2003-12-15 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | DENIED: | | | EQUIPMENT ROOM #126 AND THE ALCOVE NEAR | | | CORRIDOR #147 ARE INDICATED AS A NEW | | | FIRE RATED PARTITION.PLANS DO NOT | | | INDICATE FIRE DAMPERS ON THE MECHANICAL | | | PLANS. | | | | | | 2001 FBC(M) 607.6, SPECIFIC LOCATIONS | | | AND INSTALLATION DETAILS SHALL BE | | | SHOWN AND IDENTIFIED ON THE BUILDING | | | PLANS.PLEASE PROVIDE A NOTE SHOULD | | | ANY OF THE PENETRATIONS COMPLY WITH | | | THE EXCEPTIONS UNDER 607.1.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-28 |
Time |
18:53 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-01-28 |
Time |
18:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-17 |
Time |
15:03 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-01-17 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2004-01-17 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) - PER FBPE | | | RULING, INITIALS ARE NOT ACCEPTABLE. | | | SIGNATURE REQUIRED ON ALL SHEETS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-13 |
Time |
13:11 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-12-13 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2003-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) SHT P0.1 WATER ISOMETRIC, WATER HAM- | | | MER ARRESTOR SHALL BE LOCATED NEAR THE | | | FIXTURE IN AN "EFFECTIVE RANGE" NOT IN | | | THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALL. INSTRUC. (SEE NOTE #13) | | | 2) ENGINEERS SIGNATURE REQUIRED ON SEAL. | | | 61G15-23.002(1) & FS 471.025 PER FBPE & | | | BLDG OFFICIAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|