| Plan Review Stops For Permit 03111029 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-08-17 |
Time |
14:54 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2004-08-17 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2004-08-17 00:00:00 | REVISION# 2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-07-15 |
Time |
16:21 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2004-07-15 |
Time |
16:21 |
Sent To |
PC |
|
| Notes |
| 2004-07-15 00:00:00 | REVISIONS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-28 |
Time |
12:17 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2004-04-28 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-12-19 |
Time |
13:03 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2003-12-19 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2003-12-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03111029 | | | ADD: 219/ 221 CLEMATIS ST | | | CONT: L. DAVIS CONSTRUCTION | | | TEL: (561)718-8161 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | ACTION: DENIED | | | | | | 1) SHEET A-1.0/ A-1.1 REMOVE REFRENCES | | | OF THE SBC (STANDARD BUILDING CODE) AND | | | INSERT THE 2001 FLORIDA BUILDING CODE | | | 2002 REVISIONS. | | | | | | 2) BACK STAIRWELL, THE DOOR SWINGS INTO | | | THE CLEAR FLOOR SPACE OF THE STAIRWELL? | | | | | | 3) SHEET A-1.0 NOTE# 4, INDICATES NEW | | | A/C WORK WITHIN THE STAIR VESTIBULE. | | | 1006.1.3.1 SEE APPROVED PENETRATIONS IN- | | | TO STAIRWELL, PLANS ARE NOT CLEAR AS TO | | | WHAT WORK THAT WILL BE ACCOMPLISHED. | | | | | | 4) PLANS INDICATE THIS BUILDING IS FIRE | | | SPRINKLERED, IS THIS FIRE SPRINKLER | | | SYSTEM SUPERVISED? IF SO THEN A AREA OF | | | RESCUE ASSISTANCE IS NOT REQUIRED. | | | | | | 5) DETAIL SHEET A-2.0, THE PLANS INDI- | | | CATE DIRECTLY BEHIND THE W. C. A GRAB | | | BAR 3'-0" OVERALL DIMENSION FROM THE | | | CORNER. SEE 11-4.17.6 THE DETAIL SHEETS | | | INDICATE A MAXIMUM OF 6" FROM THE CORNER | | | THEN A 36" BAR. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-21 |
Time |
11:55 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-10-20 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2004-10-21 00:00:00 | REV FOR 1200A MAIN AND CONCRETE ENCASED | | | FEEDERS FROM FPL. | | 2004-10-20 00:00:00 | SITE TO BE INSPECTED TO VERIFY | | | CLEARENCE FOR EGRESS OF STAIRWELL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-19 |
Time |
11:36 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-02 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-18 |
Time |
09:14 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-05-18 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
08:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-21 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2004-04-21 00:00:00 | ************** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 | | | FOR ALL INFORMATION REQ'D ON TITLE | | | BLOCK. NAMEAND LICENSE # OF ENGINEER | | | SIGNING PLANS. PLEASE SEE NEW SHEET | | | E-1. THIS HAS NOW BEEN SIGNED AND SEALED | | | BY A DIFFERENT ENGINEER THAN IS NAMED | | | ON TITLE BLOCK. | | | PLEASE ALSO SEE 61G15-23.002 FAC AND | | | FS 471.023. CERTIFICATE OF AUTH IS REQ'D | | | PER ABOVE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2003-11-24 |
Time |
10:19 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2003-11-24 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2003-11-24 00:00:00 | NEED NEW PANEL SCHEDULE AND LOCATION | | | BEFORE 1ST INSPECTIONJL11-24=03 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-08-12 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-08-12 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-29 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-29 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | 1) APPROPRIATE SIGNAGE IS REQUIRED | | | AT STAIRS THAT HAVE BEEN ENCLOSED AT | | | THE BOTTOM AS NOTED ON PAGE A-1.1. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-08 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-08 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2003-12-08 00:00:00 | 1) COULD NOT LOCATE ANY EMERGENCY LIGHTS | | | ON SECOND FLOOR ELECTRICAL PLAN. | | | | | | 2) COULD NOT LOCATE ELECTRICAL PLANS | | | FOR THE FIRST FLOOR. | | | | | | 3) PLEASE EXPLAIN WHY DOOR SWINGS OUT | | | ON STAIR SHOWN ON PAGE A-1.2. | | | | | | 4) PLEASE PROVIDE MORE DETAILS ON LIVE | | | WORK LOFT. | | | | | | 5) WHY DOES THE STAIR DOOR ON THE 4TH | | | FLOOR SWING OUT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-10-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-19 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-19 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
| 2004-10-19 00:00:00 | TO DP DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-28 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-28 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | TO COMM BD#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2004-06-11 00:00:00 | TO COMM BD#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-17 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-17 |
Time |
08:34 |
Sent To |
E |
|
| Notes |
| 2004-05-17 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-16 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2004-04-16 00:00:00 | TO COMM BD#34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-19 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2003-11-19 00:00:00 | TO COMM BD#29 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-23 |
Time |
07:14 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-06-23 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-24 |
Time |
09:25 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-04-24 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2004-04-24 00:00:00 | PROVISO: | | | PER 2001 FBC(M) 607.4, DUCTS EXTENDING | | | THROUGH MORE THAN ONE FLOOR SHALL BE | | | ENCLOSED IN A FIRE RATED SHAFT.DUCTS | | | THAT PENETRATE ONLY ONE FLOOR SHALL BE | | | PROTECTED WITH A FIRE DAMPER AT THE | | | FLOOR PENETRATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-05 |
Time |
07:44 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-12-05 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2003-12-05 00:00:00 | DENIED: | | | 1.PLANS SHEET M2.1 KEYNOTES #6 SHOULD | | | THIS READ 1 & #3 IS INIDICATED AS 7. | | | PLEASE CORRELATE. | | | | | | 2.KEYNOTE 6 INDICATES FIRE DAMPERS | | | AT THE 3RD AND 1ST FLOORS.PLEASE | | | CLARIFY IF THIS DUCT IS IN A SHAFT AND | | | THE LOCATION OF THE FIRE DAMPERS ARE | | | AT THE PENETRATION INTO THE SHAFT OR | | | AT THE FLOOR.PLEASE NOTE PER 2001 | | | FBC(M) 607.4 & NFPA 90A 3-3.4.1. | | | | | | 3.NEW EQUIPMENT STANDS INDICATED ON | | | PLAN SHEET A-1.3 SHALL COMPLY WITH | | | 2001 FBC 1511.7. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-09 |
Time |
18:29 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-08-09 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2004-08-09 00:00:00 | REVISION OK - ADDED INSTA HOT FOR HEATER | | | CHANGED DOOR SWING - CHANGED VANITY CAB, | | | ADDED VENT TO W/M |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-28 |
Time |
13:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-28 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTORS TO BE LOCATED | | | NEAR THE FIXTURE - NOT IN CEILING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-12 |
Time |
14:45 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-12-09 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2003-12-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) SHT A-2.0 SHOW ACCESSIBLE W/C TO BE | | | 18" OFF WALL TO CENTER OF FIXTURE. | | | CHAPTER 11 FIGURE 28. | | | 2) SHT A-2.0 SHOW DETAILS & MEASURMENTS | | | FOR FOL. 11-4.16.3 W/C HEIGHT, 11-4.22 | | | .3 CLEAR FLOOR SPACE, CLEARANCE 11-4.19. | | | 2, EXPOSED PIPES AND SURFACES 11-4.19.4, | | | DRINKING FOUNTAIN SPOUT HEIGHT 11-4.15.2 | | | TURNING SPACE 11-4.23.3. | | | 3) SHT P-1, GENERAL SPECIFICATIONS: #22 | | | AIR CHAMBERS ARE NOT APPROVED. DELETE | | | REFERENCE. | | | 4) SHT P-2 DOMESTIC WATER RISER, WATER | | | HAMMER ARRESTORS, WHEN USED SHALL BE | | | LOCATED NEAR THE FIXTURE IN AN "EFFECT- | | | IVE RANGE" NOT IN THE CEILING AS SHOWN. | | | PDI-WH 201 AND MANUF. INSTALL. INSTRUCT- | | | IONS. | | | 5) IF PRACTICING THROUGH A DULY AUTHOR- | | | IZED ENGINEERING BUSINESS, ENGINEERS | | | SHALL LEGIBLY INDICATE THEIR NAME AND | | | LICENSE NUMBER, AS WELL AS, THE NAME, | | | ADDRESS AND CERTIFICATE OF AUTHORIZATION | | | ON THE ENGINEERING BUSINESS ON EACH | | | SHEET. 61G15-23.002(2) & FS 471.025. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|