| Plan Review Stops For Permit 03111027 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-08-09 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-08-09 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2004-08-09 00:00:00 | REVISION SUBMITTED 7/28/04 FOR SHEETS | | | A-1.0, A-1.1, A-3.0 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-06-28 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-06-28 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2004-06-28 00:00:00 | REVISION SUBMITTED ON 6/11/04.SHEETS | | | A-1.0, A-2.0 AND TI-1 STAMPED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-06-02 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-06-02 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-04-29 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-04-29 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | BEFORE A PERMIT CAN BE ISSUED: | | | | | | A) IT IS NOTED THAT THE GENERAL | | | CONTRACTOR WILL HAVE THE NOTICE OF | | | COMMENCEMENT RECORDED. | | | THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | B) THE OWNER SHALL CONFIRM WHAT THE | | | ADDRESS IS FOR THIS PROJECT.THE PLANS | | | AND ENERGY CODE COMPLIANCE FORM STATE | | | '221 CLEMATIS ST' WHICH IS NOT A VALID | | | 'TENANT ADDRESS' AT 225 CLEMATIS ST. | | | 225 CLEMATIS ST IS THE ADDRESS THAT | | | IS REFERENCED FOR THIS PROPERTY CONTROL | | | NUMBER ON PALM BEACH COUNTY PROPERTY | | | APPRAISERS RECORDS.OUR RECORDS SHOW A | | | NUMBER OF 'TENANT ADDRESSES' FOR THIS | | | PROPERTY CONTROL NUMBER (SEE ATTACHED | | | SHEET).CONFIRM WHICH IS THE CORRECT | | | ADDRESS FOR THIS PROJECT AND AMEND THE | | | DOCUMENTS ACCORDINGLY. | | | | | | C) FBC* F102.2.7FIRE DISTRICT.SHEET | | | A-1.1, KEYED NOTE 2 REFERS TO TWO | | | OPTIONS FOR THE OBSERVATION DECK | | | CONSTRUCTION.ARCHITECTURAL TRIM ON | | | BUILDINGS IN THE FIRE DISTRICT SHALL BE | | | CONSTRUCTED OF APPROVED NON-COMBUSTIBLE | | | MATERIALS OR FIRE RETARDANT TREATED WOOD | | | ANNOTATE THE PLANS ACCORDINGLY. | | | | | | D) FBC* F102.2.4ROOF COVERING IN THE | | | FIRE DISTRICT.SHEET A-1.1, ROOFING | | | SPECIFICATION SHALL INCLUDE THE | | | REQUIREMENT FOR THE ROOFING TO CONFORM | | | TO CLASS A OR B AS DEFINED IN FBC 1505. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-23 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-23 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2) FBC 1004.1.5EGRESS FROM OBSERVATION | | | DECK.THE TRAVEL DISTANCE FROM THE MOST | | | REMOTE POINT ON THE OBSERVATION DECK TO | | | DOOR E1 IS APPROX. 70 FT.ANNOTATE THE | | | PLANS TO STATE THAT THE EXISTING STAIR | | | BEYOND DOOR E1 IS A PROTECTED 'EXIT' | | | STAIR WITH 2-HOUR FIRE-RATED WALLS AND | | | 90-MINUTE RATED DOORS ALONG THE ENTIRE | | | ROUTE TO EXIT DISCHARGE. | | | | | | 3) FBC 1007.3.1 (EXCEPTION 1)STAIR | | | TREADS AND RISERS.IT IS NOTED THAT THE | | | THE NEW STAIR HAS 9.47" TREADS AND | | | 7.625" RISERS. ANNOTATE/DETAIL THE PLANS | | | TO ENSURE THAT THE TREADS (LESS THAN | | | 10") HAVE AN EFFECTIVE PROJECTION OF | | | APPROX. 1" OVER THE TREAD BELOW.NOTE | | | THAT FIRE PLAN REVIEWER HAS ALSO | | | COMMENTED ON THE STAIR. | | | | | | 4) FBC 1603OBSERVATION DECK DEAD LOAD. | | | SHEET A-4.0 SHOWS THE SAME DEAD LOAD | | | (25 PSF) FOR BOTH THE 'ROOFTOP DECK | | | LOAD' AND THE 'ROOF LOAD'.SHEET A-1.1, | | | KEYED NOTE 2 SPECIFIES TWO DECKING | | | OPTIONS FOR THE OBSERVATION DECK AREA, | | | BUT THE ABOVE DEAD LOADS DO NOT SHOW ANY | | | DIFFERENCE BETWEEN 'ROOF' AND 'ROOFTOP | | | DECK' TO ACCOUNT FOR THE WORST CASE DECK | | | SYSTEM LOAD.AMEND/ANNOTATE THE PLANS. | | | | | | 5) FBC 1608.2.1THE HANDRAIL SHALL BE | | | DESIGNED AND CONSTRUCTED FOR A | | | CONCENTRATED LOAD OF 200 LB APPLIED AT | | | ANY POINT, AND IN ANY DIRECTION, TO | | | PRODUCE MAXIMUM STRESS IN EACH OF THE | | | COMPONENTS OR SUPPORTS.AMEND/ANNOTATE | | | THE PLANS.THE GUARDRAIL DESIGN | | | CRITERIA STATED ON SHEET A-4.0 HAS | | | ALREADY BEEN NOTED. | | | | | | 6) 61G15-23.002(2)FL. ADMIN. CODE. | | | PLANS SIGNED & SEALED BY A PROFESSIONAL | | | ENGINEER SHALL INCLUDE EITHER THE NAME, | | | AND LICENSE NUMBER OF THE ENGINEER. | | | UNDER THE ENGINEER'S SEAL ON THE | | | MECHANICAL, ELECTRICAL AND PLUMBING | | | SHEETS IN THE BOX PROVIDED FOR THE SEAL, | | | THE NAME AND LICENSE NUMBER OF | | | MICHAEL J. KRAVIT SHALL BE STRUCK OUT, | | | AND THE NAME AND LICENSE NUMBER OF THE | | | ENGINEER SEALING THE MECHANICAL AND | | | PLUMBING SHEETS OR THE ELECTRICAL SHEETS | | | SHALL BE PRINTED. | | | | | | 7) FBC 13-103.1.1.1SHEET 2 OF THE | | | SUBMITTED ENERGY CODE COMPLIANCE FORM | | | SHALL INCLUDE THE NAME AND LICENSE # | | | OF THE ARCHITECT, AND THE ENGINEERS | | | RESPONSIBLE FOR THE DESIGN OF THE | | | ELECTRICAL, LIGHTING, MECHANICAL AND | | | PLUMBING SYSTEMS, TO CERTIFY COMPLIANCE. | | | | | | 8) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-18 |
Time |
09:15 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-01-18 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2005-01-18 00:00:00 | SUB LTRS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-02 |
Time |
16:54 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-02 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-17 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2004-06-17 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | SEAL ON DRAWINGS IS NOT LEGALPER DP JL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-06-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-01 |
Time |
13:46 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-01 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-03 |
Time |
11:50 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-03 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2004-05-03 00:00:00 | **********UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE NOTE FOR ARC FAULT | | | PROTECTION IS FROM THE 99 NEC. | | | PLEASE SEE 210.12 2002 NEC FOR CORRECT- | | | -ION OF NOTE. PLEASE ALSO SEE NOTE | | | PERTAINING TO SD'D BEING WIRED FROM | | | KIT/BATH LTS. IS THIS IS DONE AFCI WILL | | | BE REQ'D ON THOSE ITEMS ALSO. | | | | | | 2)NOTE: PLEASE CORRELATE ADDRESS ON PLAN | | | -S/ APPLICATION W/ WHAT SHOWS AS PARCEL | | | FILE. ONE SHOWS 219,221, 225, ETC. | | | PLEASE SEE BLDG REVIEW COMMENTS FOR | | | | | | 3)NOTE: PLEASE PROVIDE COPY OF ENGINEERS | | | SIGNATURE FROM LICENSE/DRIVERS LICENSE. | | | THESE WILL BE HELD IN FILE FOR ANY | | | FUTURE REFERENCE. | | | ANY PERSONEL INFORMATION MAY BE CROSSED | | | OUT/ADDRESS ETC. | | | FS 471.025, COMPLETE SIGNATURE IS REQ'D | | | PLEASE CALL FOR ANY QUESTIONS. | | | | | | 4)NOTE: PLEASE SEE LOADS FOR A/C UNITS | | | ARE SHOWN AS XXX. ?? PLEASE SHOW AND | | | CORRELATE WITH A/C MECH PLANS. MECH PLAN | | | -S SHOW 5.3 KW?? | | | | | | 5)NOTE: PLEASE CLARIFY METHOD OF CONTROL | | | FOR LTS TO ROOF AREA FROM BOTH LEVELS? | | | 210.70/ LS 101 5-8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2003-11-24 |
Time |
13:25 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2003-11-24 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-08-12 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-08-12 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | 1) NEW METAL PAN STAIRS WILL BE | | | UNDER SEPARATE PERMIT. THEY ARE TO | | | BE BUILT TO CODE AND THE OBSERVATION | | | DECK WILL ALSO BE UNDER SEPARATE | | | PERMIT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-06-21 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-06-21 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2004-06-21 00:00:00 | REVISION DATED 6-09-04 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-29 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-29 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | 1) BE ADVISED THAT THE LOCATION IS | | | LOCATED WITHIN THE CITY FIRE LIMTS. | | | CERTAIN RESTRICTIONS WILL APPLY. | | | PLEASE SEE APPENDIX F, LOCAL AMENDMENTS | | | TO THE FLORIDA BUILDING CODE. THE TYPES | | | OF WOOD ALLOWED IN THE FIRE LIMTS | | | IS RESTRICTED. | | | | | | 2) A PORTABLE FIRE EXTINGUISHER WILL | | | BE REQUIRED IN THE LIVE/WORK LOFT. | | | A MINIMUM OF A 2A 10BC FIRE EXTINGUISHER | | | WITH A CURRENT SERVICE TAG WILL BE | | | REQUIRED. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE FIRE SPRINKLER AND FIRE ALARM | | | SYSTEM REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-11 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-11 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2003-12-11 00:00:00 | 1) NO EMERGENCY LIGHTING SHOWN IN | | | STAIRWAY. | | | | | | 2) STAIR SECTION INDICATES 9 TREADS | | | @ 9.47". STAIR TREADS SHALL BE AT | | | LEAST 11". RISERS ARE AT 7 5/8". RISERS | | | SHALL NOT EXCEED 7". | | | | | | 3) PLEASE PROVIDE PRESCRIPTIVE | | | REQUIREMENTS FOR HANDRAILS AND | | | GUARDRAILS. | | | | | | 4) PLANS INDICATE FIRE SPRINKLER | | | PROTECTION, HOWEVER NO FIRE SPRINKLER | | | PLANS ARE PROVIDED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-14 |
Time |
15:46 |
Sent To |
E |
|
| Notes |
| 2005-01-14 00:00:00 | TO "DP" DESK/LETTERS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-25 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-25 |
Time |
10:27 |
Sent To |
M |
|
| Notes |
| 2004-08-25 00:00:00 | TO HM DESK/PER KM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-28 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-28 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | TO COMM BD#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-29 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-29 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | TO COMM BD#29 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2004-06-11 00:00:00 | TO COMM BD#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-24 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-24 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | TO COMM BD. #13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-16 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2004-04-16 00:00:00 | TO COMM BD# |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-23 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-19 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2003-11-19 00:00:00 | TO COMM BD#55 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-08-25 |
Time |
14:12 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-08-25 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-25 |
Time |
10:27 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-06 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-23 |
Time |
07:35 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-23 |
Time |
07:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-05 |
Time |
08:17 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-05 |
Time |
07:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-12-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-02 |
Time |
07:54 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2003-12-02 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-09 |
Time |
16:24 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-08-09 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2004-08-09 00:00:00 | REVISION OK - CHANGED W/H TO INSTA-HOT | | | DOOR SWING - LAV. VANITY - VENT FOR W/M |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-09 |
Time |
15:07 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-09 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2004-07-09 00:00:00 | SUBMITTAL FORM ENGINEER SHOWING APPROVAL | | | FOR HANGING WATER HEATER FROM BOTTOM OF | | | BAR JOISTS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-23 |
Time |
08:33 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-06-23 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2004-06-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHTS A2.0 AND P-1 SHEET P-1 REVISION | | | INDICATES THAT FIXTURES HAVE SHIFTED. | | | REVIEW OF PLANS SHOWS NO CHANGE OR SHIFT | | | SHT A2.O MEASURMENTS BETWEEN FIXTURES ON | | | DETAIL 01 ELEVATION "C" ARE THE SAME AS | | | THE STAMPED SET AND NO SHIFTING OF FIX- | | | TURES IS EVIDENT. PLEASE CLARIFY AND | | | CORRELATE DETAIL ON SHT A2.0 WITH SHT | | | P-1 REVISION. | | | 2) SHT P-1 PROVISO INDICATES THAT A TRAP | | | AND A STANDPIPE ARE REQUIRED AT THE WASH | | | MACHINE. ALSO A VENT IS REQUIRED FOR THE | | | WASH MACHINE. REVISE THE SANT. RISER | | | DIAGRAM TO REFLECT THESE REQUIREMENTS. | | | SECTION 104.2.1- SECTIONS 1002.1/802.4 | | | - SECTION 901.2.1 - SECTION 708.10 | | | SHOW CLEANOUT 4' ABOVE FLOOR AT WASH | | | MACHINE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-28 |
Time |
18:04 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-04-28 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | PASSED/PROVISO | | | | | | P-TRAP AND STANDPIPE REQUIRED FOR W/M |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-13 |
Time |
10:37 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2003-12-13 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2003-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FC-2001 CHAPTER 11 | | | | | | 1) SHT A-2.0 BATHROOM SHALL BE ACCESS- | | | IBLE, SUBMIT DETAILS FOR W.C. 11-4.16, | | | LAV 11-4.19, BATHTUB 11-4.20, AND BATH- | | | ROOM 11-4.23 AND ALL SUBSECTIONS. | | | 2) PER TABLE 403.1 A DRINKING FOUNTAIN | | | AND A WASH MACHINE CONNECTION ARE REQ- | | | UIRED. (ALSO SEE SECTION 410.1). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|