Plan Review Details - Permit 03110934
Plan Review Stops For Permit 03110934
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-31 Cont ID  
Sent By pkrauss Date 2003-12-08 Time 13:22 Rev Time 1.50
Received By alange Date 2003-12-31 Time 09:26 Sent To  
Notes
2003-12-31 00:00:001.NOT ALL PRODUCT APPROVALS ARE LISTED
 FBC SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 3. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
 4.SLEEPING ROOMS SHALL COMPLY WITH
 SEC. 1005.4 FBC EMERGENCY EGRESS
 REQUIREMENTS AND SEC. 1005.4.3 MAXIMUM
 HEIGHT FROM FLOOR 44".
 SHOW HEIGHT FROM FLOOR FOR EGRESS
 WINDOWS.
 5.BUILDING IS IN A FLOOD ZONE.SUBMIT
 A SOILS REPORT.
 ART LANGE
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-12-01 Cont ID  
Sent By btrobaug Date 2003-12-01 Time 12:56 Rev Time 0.50
Received By btrobaug Date 2003-12-01 Time 11:33 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-31 Cont ID  
Sent By mmclean Date 2003-11-24 Time 11:42 Rev Time 0.00
Received By csiegber Date 2003-11-20 Time 11:36 Sent To  
Notes
2003-11-25 00:00:00TO E
2003-11-20 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-12-08 Cont ID  
Sent By jleech Date 2003-12-06 Time 12:31 Rev Time 0.35
Received By pkrauss Date 2003-12-08 Time 13:02 Sent To B
Notes
2003-12-08 00:00:00DENIED:
 1.RETURN AIR REQUIRED FROM BEDROOM AREAS
 PER REVISED 2001 FBC(M) 601.4 EFFECTIVE
 JUNE 30, 2003 - SIZING SHALL BE AS
 FOLLOWS:
 DUCTED RETURN SHALL BE EQUAL TO THE
 SUPPLY.
  
 TRANSFER DUCTS SHALL BE 1 1/2 TIMES THE
 SUPPLY AIR.MASTER BEDROOM SHALL
 INCLUDE ALL SUPPLY AIR.
  
 TRANSFER GRIILES SHALL USE 50 SQ INCHES
 PER 100 CFM OF SUPPLY AIR.
  
 2.AUXILIARY DRAIN PAN REQUIRED PER 2001
 FBC(M) 307.2.
  
 PLEASE REVISE PLANS TO REFLECT CODE
 COMPLIANCE.

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-12-06 Cont ID  
Sent By btrobaug Date 2003-12-01 Time 13:05 Rev Time 0.50
Received By jleech Date 2003-12-06 Time 12:30 Sent To M
Notes
2003-12-06 00:00:00DENIED;
 RISER DIAGRAM NOT TO CODE, OR FLOOR PLAN
 W/M VENT MISSING FROM RISER DIAGRAM. W/C
 AND SHOWER ARE NOT VENTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH

Review Stop Z ZONING
Rev No 1 Status P Date 2003-11-24 Cont ID  
Sent By csiegber Date 2003-11-20 Time 11:36 Rev Time 0.00
Received By mmclean Date 2003-11-24 Time 11:42 Sent To I
Notes
***NONE***