| Plan Review Stops For Permit 03110799 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-03-25 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-03-25 |
Time |
18:34 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | STRUCTURAL REVISION SUBMITTED 3/22/04 | | | FOR SOIL STABILIZATION PROCEDURE AND | | | PLAN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-23 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-22 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-13 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-13 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | A) EACH CORRECTION/ALTERATION ADDED TO | | | THE PLANS AFTER PRINTING, SIGNING AND | | | SEALING MUST BE SIGNED AND DATED BY THE | | | ARCHITECT OF RECORD.ALTERNATIVELY, | | | THE CORRECTIONS SHOULD BE ADDED TO THE | | | PLANS PRIOR TO PRINTING, SIGNING AND | | | SEALING. | | | | | | B) 61G1-16.004FL. ADMIN. CODE.PLANS | | | PREPARED BY A REGISTERED ARCHITECT SHALL | | | INCLUDE THE FIRM'S LICENSE NUMBER ON | | | EACH SHEET. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-16 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-16 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) 61G1-16.004FL. ADMIN. CODE.THE | | | ARCHITECTURAL SHEETS MUST BE SIGNED, | | | DATED AND SEALED BY KERMIT C. WHITE. | | | | | | 2) FBC 2405.2SHEET A1.1, KEY NOTE 2. | | | THE VIEW PANEL IN THE NEW KITCHEN DOOR | | | WILL BE A 'HAZARDOUS LOCATION' AND IS | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS OR ANNOTATE | | | THE PLANS TO DEMONSTRATE COMPLIANCE. | | | | | | 3) FBC 11-5.1RESTAURANT SEATING.AT | | | LEAST 5% OF THE SEATING SHALL BE | | | ACCESSIBLE AND SHALL COMPLY WITH 11-4.32 | | | WITH RESPECT TO CLEAR FLOOR SPACE, KNEE | | | CLEARANCES AND TABLE HEIGHT.AMEND/ | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE. | | | | | | 4) FBC 11-5.2SERVICE BAR.A MINIMUM | | | 60" LENGTH OF THE BAR SHALL BETWEEN 28" | | | AND 34" ABOVE FINISHED FLOOR, TO COMPLY | | | WITH 11-4.32.4, OR SERVICE SHALL BE | | | AVAILABLE AT ACCESSIBLE TABLES WITHIN | | | THE SAME AREA.AMEND/ANNOTATE THE PLANS | | | TO DEMONSTRATE COMPLIANCE. | | | | | | 5)FBC 1010EXIT DISCHARGE.ANNOTATE | | | THE PLANS TO CLARIFY WHAT KIND OF SPACE | | | (ALLEY ETC) CORRIDOR 103 PROVIDES EXIT | | | TO, THROUGH THE EXISTING DOORS. | | | | | | 6) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-20 |
Time |
09:12 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-20 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-05 |
Time |
06:18 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-01-05 |
Time |
06:18 |
Sent To |
|
|
| Notes |
| 2004-01-05 00:00:00 | ****************** UNSAT ************** | | | | | | PLEASE SEE COMMENTS FROM FIRST REVIEW. | | | SAME NOTES. | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002. | | | PLEASE INCLUDE ALL LICENSE INFORMATION | | | ON TITLE BLOCKS PER FS 471 | | | PLEASE ALSO SEE THAT PLANS MAY HAVE ORIG | | | SEAL , HOWEVER SIGNATURE IS NOT ORIG AND | | | PLANS ARE SEALED COPIES. FS 471.025 | | | ONE SET IS BEING KEPT FOR RECORD FOR | | | ABOVE SAID VIOLATION. PLANS MAY BE KEPT | | | AND TURNED INTO THE FBPE'S FOR REVIEW. | | | | | | PLEASE SEE THAT ALL ELECTRICAL SHEETS | | | WERE AND ARE VOIDED. THIS ALSO IS NOTED | | | FOR OTHER TRADES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-15 |
Time |
14:03 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-12-15 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE INCLUDE ALL LICENSE # | | | INFORMATION ON TITLE BLOCK FOR ENGINEER | | | OF RECORD. PLEASE ALSO INCLUDE CA # | | | FOR ENG FIRM. PER FS 471.0025 AND FAC | | | 61G15-23.002 | | | PLEASE ALSO SEE PLANS ARE COPIES AND | | | NOT ORIGINAL SIGNED, DATED AND SEALED. | | | | | | PLEASE SEE THAT THIS PERTAINS TO ALL | | | TRADES AND NOT ONLY ELECTRICAL . | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-11-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2003-11-19 |
Time |
10:01 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2003-11-19 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-16 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-16 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-08 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-08 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR HOOD, DUCT, AND SUPPRESSION | | | SYSTEMS. | | | | | | 2) INTERIOR FINISH IN EXITS SHALL BE | | | CLASS A OR B. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-26 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-26 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2003-11-26 00:00:00 | 1) PLEASE INDICATE EXIT DISCHARGE | | | LOCATIONS FROM THE EXISTING DOORS | | | FROM CORRIDOR 103. | | | | | | 2) THE OCCUPANT LOAD IS TO BE DETERMINED | | | BY FIRE RESCUE. | | | | | | 3) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR THE REQUIRED HOOD, DUCT, AND | | | FIRE SUPPRESSION SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-23 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-23 |
Time |
08:48 |
Sent To |
B |
|
| Notes |
| 2004-03-23 00:00:00 | TO RB DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-01 |
Time |
09:02 |
Sent To |
P |
|
| Notes |
| 2004-03-01 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-15 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-15 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2004-01-15 00:00:00 | TO COMM BD#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-23 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-23 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | TO COMM BD#44 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-17 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2003-11-17 00:00:00 | TO COMM BD#61 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-21 |
Time |
15:28 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-01-21 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2004-01-21 00:00:00 | PROVISO: | | | ADDITIONAL PERMITS REQUIRED FOR HOOD & | | | FIRE SUPPRESSION.PLEASE PROVIDE PLANS | | | WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-01-13 |
Time |
12:50 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-01-13 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | PLAN DENIED | | | NEED FIRE DAMPERS IN RATED WALLS AT | | | ADJACENT TENANT SPACE.SEE SECTION | | | 607.1.2 2001 FLORIDA BUILDING CODE (M) | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-19 |
Time |
10:37 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2003-12-19 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2003-12-19 00:00:00 | CONVERSATION WITH MARK CONSOLIDATED | | | METALWORKS (HOOD CONTRACTOR) PLANS TO BE | | | SUBMITTED WITH THE BUILDING PLANS ON | | | 12-22-03. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-11 |
Time |
07:54 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2003-12-11 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2003-12-11 00:00:00 | DENIED: | | | 1. 61G1-16.004FL. ADMIN. CODE.PLANS | | | PREPARED BY A REGISTERED ARCHITECT SHALL | | | INCLUDE THE FOLLOWING WITH HIS TITLE | | | BLOCK: | | | - STATE DATE PREPARED | | | - INCLUDE AN ORIGINAL SIGNATURE AND | | | DATED SEAL | | | - INCLUDE THE PRINTED NAME OF THE | | | ARCHITECT SEALING THE PLANS | | | | | | 2.PLEASE CLARIFY DUCT REFERENCED IN | | | KEY NOTE 1.INIDCATE WHAT TYPE OF DUCT | | | THIS IS AND WHY DOES IT RUN THROUGH THE | | | ADJACENT TENANT WITH NO FIRE DAMPER | | | INDICATED. | | | | | | PLEASE NOTE ADDITIONAL PERMITS REQUIRED | | | FOR HOOD AND FIRE SUPPRESSION.PLEASE | | | PROVIDE THE FOLLOWING INFORMAITON ON | | | THE HOOD/GREASE DUCT FOR A REVIEW AT | | | THIS TIME OR PROVIDE COMPLETE PLANS WITH | | | HOOD PERMIT APPLICATION. | | | 1.INDICATE DUCT LAYOUT AND SIZING. | | | 2.AIR VELOCITY WITHIN DUCT SYSTEM | | | SHALL BE NOT LESS THAN 1,500 & NOT | | | GREATER THAN 2,500. | | | 3.CLEANOUTS REQUIRED AT CHANGE OF | | | DIRECTION. | | | 4.INDICATE CLEARANCE TO COMBUSTIBLES. | | | 5.EXHAUST OUTLETS SHALL BE LOCATED | | | NOT LESS THAN 10 FT HORIZONTALLY FROM | | | PROPERTY LINES AIR INTAKE OPENINGS OR | | | PARTS OF THE SAME OR CONTIGUOUS BUILDING | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2004-03-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-15 |
Time |
13:33 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-03-15 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2004-03-15 00:00:00 | REVISION OK _ CHANGED W/H TO TANKLESS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-02 |
Time |
11:00 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-03-02 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES. | | | FBC-2001 FUEL GAS | | | | | | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | MORE INFORMATION IS REQUIRED FOR THE | | | VENTING OF THE RINNAI TANKLESS WATER | | | HEATER. SUBMIT MANUF. INFO. FOR INSTALL- | | | ATION OF VENT AND SHOW HOW VENT EXHAUSTS | | | AND SUPPLIES COMBUSTION AIR. SECTION | | | 506.2.4 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
09:02 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-01-22 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2004-01-23 00:00:00 | NEED W/HEATER CUT SHEET WITH LISTING FOR | | | GAS PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-13 |
Time |
17:42 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-01-13 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: PLANS ROUTED TO | | | THE DEPT. OF BUSINESS REGULATION HOTEL | | | AND RESTURANT DIV. SHALL BE STAMPED BY | | | THEIR REVIEWER AND WORK SHEETS FROM RE- | | | VIEWER ATTACHED TO PLANS SUBMITTED FOR | | | REVIEW AT CITY OF WPB. | | | 2) FROM PREVIOUS REVIEW: FOR GAS REVIEW. | | | A. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 3) ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, ADDRESS, AND LICENSE NUMBER | | | ON EACH SHEET. IF PRACTICING THORUGH A | | | DULY AUTHORIZED ENGINEERING BUSINESS, | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER, AS WELL AS, THE | | | NAME, ADDRESS AND CERTIFICATE OF AUTHOR- | | | IZATION NUMBER OF THE ENGINEERING BUSIN- | | | ESS ON EACH SHEET. 61G15-23.002(2) AND | | | FS 471. | | | 4) SEE ATTACHED SHEET WITH STANDARD | | | GREESE TRAP DETAIL APPROVED BY CITY OF | | | WEST PALM BEACH. DETAIL ON SHEET P1.1 | | | NOT APPROVED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-13 |
Time |
08:23 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-12-12 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2003-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) ROUTE PLANS TO THE DEPT. OF BUSINESS | | | REGULATION HOTEL AND RESTURANT DIV. FOR | | | REVIEW PRIOR TO RESUBMITTING PLANS. | | | 2) CONTACT RODNEY COMPO, INDUSTRIAL PRE- | | | TREATMENT, ENVIRONMENTAL COMPLIANCE MGR. | | | FOR SIZING OF GREASE INTECPTOR. WASTE | | | ORD. 2938-96 - (561) 837-4074 | | | 3) SHT P1.1 PLUMBING NOTES: #1 CODE | | | ADOPTED AND IN AFFECT IS THE FLORIDA | | | BUILDING CODE PLUMBING NOT THE BOCA CODE | | | AMEND REFERNCE. | | | 4) SHT P1.1 PLUMBING NOTES: #3 AIR CHAM- | | | BERS ARE NOT APPROVED. DELETE REFERENCE. | | | SEC 604.9 | | | 5) SHT P1.1 GAS WATER HEATER DETAIL, THE | | | DRAINAGE PIPING FROM THE P/T (RELIEF) | | | VALVE SHALL DRAIN TO A FLOOR SINK OR A | | | HUB DRAIN. FLOOR SINKS ARE NOT APPROVED | | | INDIRECT WASTE RECEPTORS. SEC 802.3 - | | | ALL OTHER INDIRECT WASTE SHALL DRAIN TO | | | A FLOOR SINK. (IN KITCHEN FOOD PREP AREA | | | ECT.) - ALSO SEE SHEET P1.2 | | | 6) SHT P1.2 DOMESTIC WATER RISER, AIR | | | CHAMBERS NOT APPROVED. 604.9 DELETE | | | FROM RISER. WATER HAMMER ARRESTORS RE- | | | QUIRED BY SECTION 604.9 SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING. PDI-WH 201 AND MANUF | | | INSTALL. INSTRUCT. | | | 7) FOLLOWING INFORMATION REQUIRED FOR | | | GAS PERMIT. | | | A. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES. | | | B. TYPE OF GAS, (LP OR NATURAL) | | | C. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | D. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | G. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | H. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | I. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|