Plan Review Details - Permit 03110653
Plan Review Stops For Permit 03110653
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-02 Cont ID  
Sent By rbrown Date 2004-03-02 Time 16:11 Rev Time 0.00
Received By rbrown Date 2004-03-02 Time 16:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-02-09 Cont ID  
Sent By rbrown Date 2004-02-09 Time 16:17 Rev Time 0.00
Received By rbrown Date 2004-02-09 Time 09:39 Sent To  
Notes
2004-02-09 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 12/5/03:
  
 3) FBC 13-103.1.2BEFORE A BUILDING
 PERMIT CAN BE ISSUED, THE SUBMITTED
 ENERGY CODE COMPLIANCE FORMS SHALL BE
 SIGNED BY THE BUILDING OWNER, THE
 OWNER'S ARCHITECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
 NOTE: ONLY ONE COPY WAS SUBMITTED.
 SUBMIT A SECOND COPY.
  
 4) SINGLE PLY MEMBRANE ROOFING PRODUCT
 APPROVAL.THE CORRESPONDING STATE
 APPROVAL COVER SHEET WITH REFERENCE #
 HAS BEEN PRINTED AND ATTACHED TO THE
 SUBMITTED MIAMI-DADE NOTICE OF
 ACCEPTANCE.MARK THE PRODUCT APPROVAL
 SHEETS, AS APPROPRIATE, TO IDENTIFY
 WHICH PRODUCT SYSTEM/OPTIONS/MATERIALS
 ARE BE USED.
  
 5) FL. ADMIN CODE RULE 9B-72.
 A SEARCH AT THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 SHOWS NO MATCHING STATEWIDE PRODUCT
 APPROVAL FOR THE SUBMITTED ARCH ALUMINUM
 FIXED WINDOW WALL PRODUCT APPROVAL
 (NOA# 01-0329.02) OR CECO DOOR PRODUCTS'
 OUTSWING STEEL DOOR PRODUCT APPROVALS
 (NOA#'S 00-0315.03 & 01-0118.01). EITHER
 SPECIFY ALTERNATIVES THAT HAVE STATEWIDE
 APPROVAL OR APPLY FOR SITE SPECIFIC
 PRODUCT APPROVAL BY HAVING THE
 MANUFACTURER COMPLETE THE FORM
 'APPLICATION FOR SITE SPECIFIC PRODUCT
 APPROVAL' (AVAILABLE FROM THIS OFFICE).
  
 7) FBC 1606.1TRUSS ANCHOR WIND UPLIFT.
 AMEND SHEET S-1 TO SPECIFY THE ANCHOR
 FASTENERS REQUIRED TO ACHIEVE THE STATED
 UPLIFTS FOR THE SIMPSON H16 AND HUS26
 TIES.
  
 9) FBC 11-4.16.4SHEET A-5, REVISED
 GRAB BAR ON ACCESSIBLE W.C. DETAIL 11.
 THE GRAB BAR SHALL EXTEND AT LEAST 12"
 ON EACH SIDE OF THE W.C. CENTER LINE
 (REF. FIG. 29A)
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-05 Cont ID  
Sent By rbrown Date 2003-12-05 Time 16:44 Rev Time 0.00
Received By rbrown Date 2003-12-05 Time 16:41 Sent To  
Notes
2003-12-05 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) FBC 13-103.0ENERGY CODE COMPLIANCE
 SHALL BE DEMONSTRATED BY SUBMITTAL OF
 APPROPRIATE ENERGY CODE COMPLIANCE FORMS
  
 4) SUBMIT PRODUCT APPROVALS FOR THE
 NEW ROOF COVERING SYSTEM.
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
  
 5) SUBMIT PRODUCT APPROVALS FOR THE
 WINDOWS AND EXTERIOR DOORS.
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
  
 6) FBC 1606.2.5DESIGN WIND PRESSURES.
 THE PLANS SHALL BE AMENDED TO SHOW THE
 POSITIVE AND NEGATIVE DESIGN WIND
 PRESSURES ACTING ON THE WINDOWS,
 EXTERIOR DOORS AND ROOF COVERING, FOR
 CROSS-REFERENCE WITH THE PRODUCT
 APPROVALS TO ESTABLISH SUITABILITY OF
 THE SPECIFIED PRODUCTS.
  
 7) FBC 1606.1TRUSS ANCHOR WIND UPLIFT.
 SHEET S-1, ROOF FRAMING PLAN SPECIFIES
 SIMPSON HU65 ANCHORS AT THE NEW TRUSSES.
 THIS IS NOT A VALID SIMPSON REFERENCE.
 AMEND THE PLAN.
  
 8) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-01-20 Cont ID  
Sent By dpalmer Date 2004-01-20 Time 13:14 Rev Time 0.75
Received By dpalmer Date 2004-01-20 Time 11:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-20 Cont ID  
Sent By jleahy Date 2003-11-20 Time 10:22 Rev Time 0.55
Received By jleahy Date 2003-11-20 Time 10:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-06-23 Time 14:14 Rev Time 0.00
Received By mcarsill Date 2004-01-16 Time 15:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-12-08 Cont ID  
Sent By mcarsill Date 2003-12-08 Time 12:35 Rev Time 0.00
Received By mcarsill Date 2003-12-08 Time 12:35 Sent To  
Notes
2003-12-08 00:00:001) EXIT SIGN ON PAGE E-2 IS NOT
 LOCATED OVER DOUBLE DOORS.
  
 2) SEPARATE PLANS AND PERMITS REQUIRED
 FOR NEW FIRE ALARM EQUIPMENT PLANNED
 FOR USE.
  
 3) ELECTRIC DOOR LOCK NOTED ON EXIT
 DOOR. LOCKING DEVICES ON EXIT DOORS
 SHALL COMPLY WITH SPECIAL LOCKING
 ARRANGEMENTS.
  
 4) ALL NEW STAIRS AND HANDRAILS SHALL
 BE EQUIPPED WITH HANDRAILS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-08-20 Cont ID  
Sent By csiegber Date 2004-08-20 Time 16:32 Rev Time 0.00
Received By csiegber Date 2004-08-20 Time 16:32 Sent To M
Notes
2004-08-20 00:00:00TO PK BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-06 Cont ID  
Sent By csiegber Date 2004-07-06 Time 15:53 Rev Time 0.00
Received By csiegber Date 2004-07-06 Time 15:53 Sent To M
Notes
2004-07-06 00:00:00TO PK DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-25 Cont ID  
Sent By rbrown Date 2004-02-25 Time 10:53 Rev Time 0.00
Received By rbrown Date 2004-02-25 Time 10:53 Sent To  
Notes
2004-02-25 00:00:001ST RESUB.PLANS AND APPLICATION TO
 R BROWN'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-01-15 Time 16:19 Rev Time 0.00
Received By csiegber Date 2004-01-15 Time 16:17 Sent To  
Notes
2004-01-15 00:00:00TO COMM BD#15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-08 Cont ID  
Sent By mmclean Date 2004-02-09 Time 09:38 Rev Time 0.00
Received By rbrown Date 2003-11-14 Time 14:21 Sent To  
Notes
2003-11-18 00:00:0011/14/03TO Z
 TO COMM BD#23

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2004-09-01 Cont ID  
Sent By pkrauss Date 2004-09-01 Time 07:29 Rev Time 0.25
Received By pkrauss Date 2004-09-01 Time 07:29 Sent To  
Notes
2004-09-01 00:00:00SUBMITTAL/ENGINEER DETAIL FOR THE
 MOUNTING OF CONDENSING UNIT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-07-08 Cont ID  
Sent By csiegber Date 2004-08-20 Time 16:32 Rev Time 0.40
Received By pkrauss Date 2004-07-08 Time 12:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-26 Cont ID  
Sent By csiegber Date 2004-07-06 Time 15:53 Rev Time 0.40
Received By pkrauss Date 2004-01-26 Time 10:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-11-25 Cont ID  
Sent By hmoser Date 2003-11-25 Time 18:15 Rev Time 1.00
Received By hmoser Date 2003-11-25 Time 18:15 Sent To  
Notes
2003-11-25 00:00:00PLAN DENIED
 1) NO FRESH AIR CALCULATIONS
 2) REFER TO SECTION 601.4 BALANCED
 RETURN AIR
 3) REFER TO SECTION 606 SMOKE DETECTION
 SYSTEMS
 PLAIN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-01-24 Cont ID  
Sent By kstevens Date 2004-01-24 Time 07:45 Rev Time 0.33
Received By kstevens Date 2004-01-24 Time 07:45 Sent To  
Notes
2004-01-24 00:00:00PASSED/PROVISO
  
 ABANDONED GREASE TRAP, (SHT A-1), SHALL
 BE CLEANED, AND THE BOTTOM BROKEN SO THE
 WATER WILL DRAIN.

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-12-08 Cont ID  
Sent By kstevens Date 2003-12-08 Time 18:47 Rev Time 1.00
Received By kstevens Date 2003-12-08 Time 18:47 Sent To  
Notes
2003-12-08 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLA. ADMIN. CODE
 FLA. STATUTES
  
 1) SHT A-1 TOILET ROOM 103, SHOW CLEAR
 FLOOR SPACE AND TURNING AREA PER SECTION
 11-4.22.3
 2) SHT P-1 KEYNOTE #2, SINK IN SACRISTY
 SHALL DRAIN INTO SANITARY. DRYWELL NOT
 APPROVED. SECTION 701.2
 3) SIGNATURE REQUIRED ON SEAL OF ENGIN-
 EER PER FAC 61G15-23.002(1) & FLA. STAT-
 UTES. INITIALS NOT APPROVED PER FBPE &
 BLDG. OFFICIAL.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-11-18 Cont ID  
Sent By csiegber Date 2003-11-14 Time 14:21 Rev Time 0.00
Received By mmclean Date 2003-11-18 Time 09:20 Sent To I
Notes
***NONE***