| Plan Review Stops For Permit 03110633 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-07-20 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | DOOR SCHEDULE WAS REDLINED ON 7/20/04 BY | | | THE ARCHITECT TO CHANGE DOOR #107 FROM A | | | GLAZED INSWING DOOR TO A HOLLOW METAL | | | INSWING DOOR DUE TO LACK OF PRODUCT | | | APPROVAL FOR A GLAZED DOOR. IF THE SHEET | | | IS SUBMITTED AGAIN AFTER PERMIT ISSUE, | | | AS PART OF ANY REVISION, IT MUST | | | INCORPORATE THE REDLINED AMENDMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-05-19 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-05-19 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | PLAN REVIEW COMMENTS AMENDED AGAIN.SEE | | | BELOW. | | | . | | 2004-07-12 00:00:00 | PLAN REVIEW COMMENTS HAVE BEEN AMENDED | | | TO COVER THE ADDITIONAL PRODUCT | | | APPROVALS SUBMITTED BY WEST CONSTRUCTION | | | SEE AMENDED COMMENTS BELOW. | | | . | | 2004-06-30 00:00:00 | PLAN REVIEW COMMENTS LISTED AS 5/19/04 | | | HAVE BEEN AMENDED TO COVER THE PRODUCT | | | APPROVALS SUBMITTED AFTER THE INITIAL | | | PLAN REVIEW. | | | . | | 2004-05-19 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | WORKING DRAWING REVIEW ONLY.NO | | | PERMIT CAN BE ISSUED UNTIL THE PERMIT | | | APPLICATION AND FEES ARE SUBMITTED BY | | | THE SELECTED CONTRACTOR. | | | | | | ADDRESS INFORMATIVE: | | | OF THE PARCELS REFERENCED BY THE UNITY | | | OF TITLE, THE ONE ADDRESSED 525 49TH ST | | | HAS THE LOWEST PROPERTY CONTROL NUMBER | | | (74-43-43-04-04-003-0351).THAT IS THE | | | PROPERTY CONTROL NUMBER WHICH SHOULD BE | | | USED TO REFERENCE THE SITE.DUE TO THE | | | LOCATION OF THE ENTRANCE(S), THE DEFAULT | | | ADDRESS 525 49TH ST IS NOT SUITABLE. | | | NEW ADDRESSES MUST BE ASSIGNED.THE | | | ADDRESSES FOR THE COMMUNITY/TRAINING | | | ROOM AND THE FIRE RESCUE STATION MUST | | | BE EVEN NUMBERS BETWEEN 5000 AND 5098 | | | AND THE COMMUNITY/TRAINING ROOM ADDRESS | | | MUST BE NUMERICALLY LOWER THAN THE | | | FIRE RESCUE STATION ADDRESS.THE | | | COMMUNITY/TRAINING ROOM WILL BE A TENANT | | | ADDRESS OF THE FIRE RESCUE STATION. | | | **AS REQUESTED BY JEFF HALVERSON ON | | | 7/12/04 THE COMMUNITY/TRAINING ROOM | | | ADDRESS WILL BE 5000 BROADWAY AND THE | | | FIRE RESCUE STATION WILL BE | | | 5050 BROADWAY. | | | | | | PROVISO | | | ON 7/20/04 THE DOOR SCHEDULE WAS RED- | | | LINED BY ARCHITECT TO CHANGE DOOR #107 | | | FROM A GLAZED INSWING DOOR TO A HOLLOW | | | METAL INSWING DUE TO LACK OF PRODUCT | | | APPROVAL FOR THE GLAZED DOOR.IF THE | | | SHEET IS SUBMITTED AGAIN AFTER PERMIT | | | ISSUE, AS PART OF ANY REVISION, IT MUST | | | INCORPORATE THE RED-LINED AMENDMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-04-28 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-04-28 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2004-04-28 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 12/11/03: | | | | | | 3) FBC 13-103ENERGY CODE COMPLIANCE | | | (A) FBC 13-103.1.1.1IT IS NOTED THAT | | | THE MECHANICAL ENGINEER HAS SIGNED | | | SHEET 2 OF THE SUBMITTED ENERGY CODE | | | COMPLIANCE FORMS.THE PROFESSIONALS | | | RESPONSIBLE FOR THE DESIGN OF THE | | | BUILDING SHELL AND THE ELECTRICAL, | | | LIGHTING AND PLUMBING SYSTEMS SHALL EACH | | | SIGN SHEET 2 OF THE ENERGY CODE CODE | | | COMPLIANCE FORM, IN THE SPACE PROVIDED, | | | TO CERTIFY COMPLIANCE. | | | (B) FBC 13-103.1.2BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | | | 4) PRODUCT APPROVAL FOR THE PROPOSED | | | SPANISH 'S' TILE AND BUILT-UP ROOFING. | | | THE RESPONSE REFERING TO NOTE 1 ON | | | SHEET G-2 IS NOTED.PRODUCT APPROVALS | | | MUST BE SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | | | | 4) PRODUCT APPROVAL FOR THE PROPOSED | | | WINDOWS, GLASS BLOCK, EXTERIOR DOORS AND | | | SIDELITES, HURRICANE SHUTTERS AND ROLL- | | | UP DOORS.THE RESPONSE REFERING TO | | | NOTE 1 ON SHEET G-2 IS NOTED.PRODUCT | | | APPROVALS MUST BE SUBMITTED BEFORE A | | | PERMIT CAN ISSUED. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | 6) SHEET A6.1AMEND THE WINDOW SCHEDULE | | | TO STATE WINDOW TYPE AS FIXED, CASEMENT | | | ETC SO THAT THE APPLICABILITY OF THE | | | PRODUCT APPROVALS (SEE COMMENT #4) CAN | | | BE VERIFIED WHEN THEY ARE SUBMITTED. | | | | | | 13) SHEET S-2, ROOF FRAMING PLAN.THE | | | SPECIFIED ANCHOR TYPE FOR THE MONOSLOPE | | | ROOF IS TYPE J.THE TRUSS TIE DOWN | | | SCHEDULE, ON SHEET S-3, STATES THE | | | REFERENCE AS LUS26, WITH AN UPLIFT | | | CAPACITY OF 1140#.THIS DOES NOT | | | REFLECT THE 930# CAPACITY STATED IN THE | | | 2004 SIMPSON CATALOG.NEITHER CAPACITY | | | IS SUFFICIENT FOR THE EXPECTED UPLIFT ON | | | THE MONOSLOPE ROOF TRUSS.SPECIFY | | | ALTERNATIVE ANCHORS AND CORRECT THE | | | CAPACITY STATED ON THE SCHEDULE. | | | | | | 15) THE REVISIONS MADE SINCE THE LAST | | | REVIEW HAVE NOT BEEN HIGHLIGHTED BY | | | REVISION CLOUDS/MARKERS AND ONE COPY OF | | | THE OLD PLANS WAS NOT SUBMITTED.AS A | | | RESULT THE PLANS HAVE BEEN SUBJECT TO | | | ANOTHER FULL REVIEW, SEE COMMENTS | | | NUMBERED 16 AND UP. | | | NOTE:TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | | | | COMMENTS RESULTING FROM SECOND FULL | | | REVIEW OF PLANS PER COMMENT 15: | | | | | | 16) FBC 11-4.8.2RAMP.SHEET A2.1 DOES | | | NOT CLEARLY SHOW THE EXTENT OF THE RAMP | | | FROM THE FOUNTAIN UP TO THE ENTRY TOWER | | | AND THERE IS NO CROSS-SECTION SHOWING | | | THE CHANGE IN LEVEL.AMEND THE PLANS TO | | | PROVIDE THIS INFORMATION AND DEMONSTRATE | | | PROVISION OF THE REQUIRED HANDRAILS AND | | | A COMPLIANT RAMP SLOPE OF 1 IN 12 (OR | | | BETTER). | | | | | | 17) FBC 1608.2.1ALL HANDRAILS SHALL BE | | | DESIGNED AND CONSTRUCTED FOR A | | | CONCENTRATED LOAD OF 200 LB AND A LINE | | | LOAD OF 50 PLF.THESE LOADS SHALL NOT | | | BE APPLIED SIMULTANEOUSLY BUT SHALL BE | | | APPLIED INDIVIDUALLY AT ANY POINT, AND | | | IN ANY DIRECTION, TO PRODUCE MAXIMUM | | | STRESS IN EACH OF THE COMPONENTS OR | | | SUPPORTS.AMEND/ANNOTATE THE PLANS. | | | SEE ALSO FIRE PLAN REVIEW COMMENT. | | | | | | 18) FBC 705.1.3GENERATOR ROOM DOOR. | | | DOOR 147A IS IN A 2-HR FIRE-RATED WALL | | | BUT IS NOT SHOWN AS RATED ON THE DOOR | | | SCHEDULE (SHEET A6.1).AMEND THE DOOR | | | SCHEDULE. | | | | | | 19) BOUNDARY SURVEY SHT FP1977 (1 OF 2). | | | THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.SUBMIT A COPY OF THE 'UNITY | | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-11 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-11 |
Time |
14:24 |
Sent To |
Z |
|
| Notes |
| 2003-12-11 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) WHEN THE PLANS ARE SUBMITTED FOR | | | PERMIT, THE TITLE BLOCK ON EACH SHEET | | | SHALL INCLUDE THE SIGNATURE, SEAL AND | | | PRINTED LICENSE NUMBER OF ARCHITECT OR | | | ENGINEER OF RECORD. | | | | | | 2) THE PLANS ARE STATED AS BEING 90% | | | COMPLETE.THE FOLLOWING REVIEW COMMENTS | | | ARE BASED ON THE INCOMPLETE PLANS | | | SUBMITTED. | | | | | | 3) FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 4) SUBMIT PRODUCT APPROVALS FOR THE | | | SPANISH 'S' TILE AND FOR THE BUILT UP | | | ROOFING. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | 5) SUBMIT PRODUCT APPROVALS FOR THE | | | WINDOWS, GLASS BLOCK, EXTERIOR DOORS AND | | | SIDELITES, HURRICANE SHUTTERS AND ROLL- | | | UP DOORS. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | 6) SHEET A6.1THE WINDOW SCHEDULE IS | | | INCOMPLETE. | | | | | | 7) SHEET A2.5THE WALL TYPES PLAN | | | LEGEND SHOULD BE AMENDED TO REFER TO | | | SHEET A2.6 FOR THE WALL TYPE DETAILS. | | | ALSO THE PLAN DOES NOT SHOW A WALL TYPE | | | FOR MANY OF THE WALLS (JUST SHOWN AS | | | TYPE X). | | | | | | 8) FBC 2405.2SHEET A2.5 SHOWS A NUMBER | | | OF INTERIOR WALLS WHICH APPEAR TO BE | | | GLAZED WITHIN 24 INCHES OF DOORS.THESE | | | ARE'HAZARDOUS LOCATIONS' AND ARE | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 9) FBC 11-4.24.4SHEET A5.3, SECTION 6A | | | THE PANTRY SINK SHALL BE MAXIMUM 6-1/2" | | | DEEP.ANNOTATE THE PLANS ACCORDINGLY. | | | | | | 10) SHEET A6.4, SECTION 1.WHERE DOES | | | THIS DETAIL OCCUR?SHOULD IT BE CALLED | | | UP ON SHEET A4.3, SECTION 2?ANNOTATE | | | THE PLANS TO SHOW THE LOCATIONS WHERE | | | THIS DETAIL OCCURS. | | | | | | 11) FBC TABLE 1606SHEET S-3, CODES | | | AND STANDARDS NOTE #1.FOR A FIRE | | | RESCUE STATION, THE IMPORTANCE FACTOR | | | SHOULD BE 1.15 (NOT 1.0).AMEND THE | | | NOTE AND MAKE ANY NECESSARY DESIGN | | | CHANGES. | | | | | | 12) SHEET S-3, WIND LOAD SCHEDULE.THE | | | ZONE 3 ROOF WIND SUCTION LOAD SHOULD BE | | | -78.3 PSF (NOT -38.3 PSF).AMEND THE | | | PLAN. | | | | | | 13) SHEET S-4, SECTION 6.THE MONOSLOPE | | | TRUSSES FOR THE LOWER ROOF ARE SHOWN | | | SUPPORTED BY LEDGERS BOLTED INTO THE | | | BOND BEAM.SHEET S-2 (ROOF PLAN) SHOWS | | | THE TRUSSES TIED DOWN WITH TYPE N | | | ANCHORS WHICH ARE SIMPSON HHETA 20. THAT | | | TYPE OF ANCHOR IS NOT SUITABLE FOR | | | CONNECTION BETWEEN WOOD LEDGERS AND A | | | WOOD TRUSS SUBJECT TO UPLIFT.AMEND THE | | | PLAN TO SPECIFY A SUITABLE ANCHOR. | | | | | | 14) INFORMATIVE: | | | SHEET S-3, TRUSS TIE DOWN SCHEDULE.IT | | | IS NOTED THAT ONLY ANCHOR TYPES B,D & N | | | ARE SPECIFIED ON THE ROOF PLAN.NOTE | | | THAT ANCHOR TYPES J & K ARE LISTED AS | | | 'HUGHES' ANCHORS, AND THAT COMPANY NO | | | LONGER SUPPLIES TRUSS ANCHORS. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-19 |
Time |
17:49 |
Rev Time |
1.25 |
| Received By |
dpalmer |
Date |
2004-05-19 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2004-05-19 00:00:00 | REDLINED | | | | | | | | | FOOTER STEEL REQ'D FOR GROUNDING ELEC- | | | -TRODE 250.50 | | | | | | GFI PROTECTION FOR KITCHEN RECEPTS PER | | | 210.8B3 | | | | | | STAMPED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-21 |
Time |
16:38 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2004-04-18 |
Time |
19:00 |
Sent To |
|
|
| Notes |
| 2004-04-21 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 | | | PLEASE INCLUDE PRINTED NAME AND LICENSE | | | # OF ENGINEER ON TITLE BLOCK. | | | | | | 2)NOTE: PLEASE SEE SOME ITEMS ARE | | | WHITED OUT ON PLANS. WHITE OUT IS NOT | | | PERMITTED ON SIGNED AND SEALED PLANS. | | | FS 471/481 | | | | | | 3)NOTE: PLEASE SUBMIT SPECIFICATIONS | | | FOR GENERATOR/ATS/ ETC. | | | PLEASE INDICATE IF MCB IS LOCATED ON | | | THE OUTSIDE OF GENERATOR W/ OUT EXSPOS- | | | -URE OF LIVE PARTS IN VIOLATION OF | | | NEC 110.27 | | | | | | 4)NOTE: PLEASE SHOW/INDICATE POINTS | | | OF CONNECTION FOR GROUNDING OF TRANS- | | | -FORMERS PER 250.30 | | | | | | 5)NOTE: PLEASE SEE RISER, CONDUCTORS | | | FEEDING LPD ARE SHOWN AS 1/0'S TO A | | | 225A PANEL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-03 |
Time |
07:38 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2003-12-03 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2003-12-03 00:00:00 | ************* UNSAT ******************* | | | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED, DATED | | | AND SEALED BY THE ENGINEER OF RECORD. | | | PLEASE INCLUDE ALL LICENSE #`S ON TITLE | | | BLOCK FOR ENG FIRM AND INDIVIDUAL THAT | | | SEALS PLANS.:ABOVE PER: FS471.025 AND | | | 61G15-23.002 OF THE FAC. | | | | | | 2)NOTE: PLEASE BE AWARE THAT THERE MAY | | | BE OTHER COMMENTS TO FOLLOW AS PLANS/ | | | DRAWINGS ARE LABELED AS 90% COMPLETE AS | | | OF SUBMITTAL FOR REVIEW.?? | | | UNABLE TO DO A COMPLETE REVIEW AT THIS | | | DUE TO PLANS NOT BEING COMPLETE. | | | | | | PLEASE SUBMIT THE ABOVE INFOMATION FOR | | | REVIEW. IF THERE ARE ANYQUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-22 |
Time |
15:17 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-22 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-12-05 |
Time |
13:50 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-12-05 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2003-12-05 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE STORM WATER | | | CALCULATION FOR OUR REVIEW, INCLUDE | | | PERVIOUS AND IMPERVIOUS AREA FOR TOTAL | | | SITE. | | | 2. DCDA MUST BE INSTALLED ON PROPERTY | | | AT BACK OF THE SIDEWALK. | | | 3. A CLEAN-OUT MUST BE INSTALLED IN | | | SEWER LATERAL ON PROPERTY, BACK OF THE | | | SIDEWALK. | | | 4. PLEASE SUBMIT CIVIL PLANS ONLY TO THE | | | PUBLIC UTILITIES AND ENGINEERING FOR | | | ALL THE CONNECTIONS TO CITY SERVICES AND | | | THEIR REQUIREMENTS. | | | 5. PLEASE CONTACT RODNEY COMPO FOR | | | INSTALLATION OF GREASE/WATER SEPARATOR, | | | SIZE, LOCATION.TWO DETAILS SHOWN,SHEET | | | C-4.2. 837-4051 EX. 4074 | | | 6. ALL PARKING STALLS MUST BE PAINTED | | | WITH DOUBLE 4" WIDE STRIPES, PLEASE | | | REVISE DETAILS, SHEET C-4.3 | | | 7. DUMPSTER INCLOSURE MUST BE SIZED AT | | | MIN. 12'-6" OPENING BETWEEN THE POSTS | | | AND 12'-0" DEEP. | | | 8. PULLOTION PREVENTION PLANS MUST BE | | | INCLUDED IN CIVIL PLAN AND MUST BE | | | INSTALLED IN THE FEILD PRIOR TO ANY | | | EARTH/CONSTRUCTION WORK BEGINS. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-21 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-21 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2004-05-21 00:00:00 | 1) ENSURE THAT A MINIMUM OF AT LEAST | | | ONE FOOT CANDLE IS PROVIDED BY THE | | | EMERGENCY LIGHTING SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-09 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-09 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2004-04-09 00:00:00 | 1) ELECTRONIC SWITCHES, CHANIN AND | | | LOCK REQUIRED ON BACKFLOW DEVICE. | | | NO CHANGE NOTED TO PAGE C-4.2. | | | | | | 2) DOOR 147A IS NOT RATED PER THE DOOR | | | SCHEDULE. DOOR IS LOCATED IN RATED | | | WALL THEREFORE AN OPENING PROTECTIVE | | | IS REQUIRED. PLEASE REVISE PLANS | | | AS NECESSARY. | | | | | | 3) PRESCRIPTIVE STRENGTH REQUIREMENTS | | | FOR HANDRAILS AND GUARDRAILS SHALL | | | MEET THE FLORIDA BUILDING CODE AND | | | THE FLORIDA FIRE PREVENTION CODE. | | | | | | 4) THE ABOVE GROUND FUEL STORAGE TANK | | | SHALL BE PROTECTED BY BOLLARDS TO | | | PREVENT MECHANICAL DAMAGE, BE LABELED | | | AS TO ITS DEISEL CONTENT, AND BE | | | PLACARDED IN ACCORDANCE WITH NFPA | | | 704. ALSO NO SMOKING SIGNS SHALL | | | BE PROVIDED. | | | | | | 5) THE FIRE DEPARTMENT CONNECTION FOR | | | THE FIRE SPRINKLER SYSTEM SHALL BE | | | PROVIDED WITH CLEAR ACCESS AND BE | | | PROVIDED WITH SEVEN FEET, SIX INCHES | | | OF CLEARANCE. | | | | | | 6) WHAT PREVENTS THE GENERATOR EXHAUST | | | FROM BACKFEEDING INTO THE AIR EXHAUST | | | LOUVERS. | | | | | | 7) ALL SMOKE DETECTORS SHALL BE MOUNTED | | | A MINIMUM OF THREE FEET FROM AIR | | | CONDITIONER DIFFUSERS. | | | | | | 8) PLEASE CLEARLY IDENTIFY ALL | | | EMERGENCY LIGHT FIXTURES ON THE PLAN. | | | | | | 9) THE OPENING FROM 50TH STREET SHOULD | | | BE WIDER BECAUSE SERVICE VEHICLES WILL | | | HAVE TO ENTER THOUGH THE SEPARATED | | | OPENING. THESE INCLUDE SANITATION | | | TRUCKS AND FUEL TRUCKS. THE DIVIDER | | | SERVES NO REAL PURPOSE BUT WOULD | | | PROVIDE A POTENTIAL FOR MISHAPS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-26 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-26 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2003-11-26 00:00:00 | 1) SITE PLAN DOES NOT REFLECT | | | EXISTING FIRE HYDRANT LOCATIONS. | | | | | | 2) ELECTRONIC SWITCHES WILL BE REQUIRED | | | ON THE FIRE LINE BACKFLOW DEVICE. | | | | | | 3) THE AUTOMATIC GATE ON 50TH STREET | | | SHALL PROVIDE AT LEAST 20 FEET IN | | | CLEAR WIDTH. | | | | | | 4) PLEASE INDICATE ON PLANS WHICH | | | OFFICE WILL BE FOR THE FIRE | | | PREVENTION BUREAU. | | | | | | 5) NO FIRE EXTINGUISHER SHOWN | | | IN COMMUNITY/TRAINING ROOM. | | | | | | 6) ROOM NEAR RADIO EQUIPMENT IS | | | NOT LABELED. | | | | | | 7) PROVIDE DETAILS ON FUEL TANK. | | | PLEASE DISPLAY BARRIER PROTECTION, | | | WARNING LABELS, AND PROVIDE PRODUCT | | | APPROVALS. | | | | | | 8) ALL NEW STAIRS AND RAMPS SHALL | | | HAVE HANDRAILS ON BOTH SIDES. | | | | | | 9) ROOF PLAN DISPLAYS TWO KITCHEN | | | SUPPLIES AND NO EXHAUST. PLEASE CORRECT. | | | THE KITCHEN EXHAUST DUCT TERMINATION | | | SHALL HAVE AT LEAST 10 FEET SEPARATION | | | FROM KITCHEN SUPPLY. | | | | | | 10) THE BUILDING ADDRESS IS REQUIRED | | | ON THE CORRECT ELEVATION. A MINIMUM | | | OF AT LEAST 6" HIGH NUMBERS ARE | | | REQUIRED. | | | | | | 11) THE FIRE HYDRANT AND THE FIRE | | | DEPARTMENT CONNECTION SHALL BE | | | PROVIDED WITH 7'-6" OF CLEARANCE. | | | | | | 12) THE GENERATOR EXHAUST SHALL BE | | | A MINIMUM OF AT LEAST 10 FEET FROM | | | ANY BUILDING OPENINGS. | | | | | | 13) THE LIGHTING PLAN DOES NOT MATCH | | | THE LIFE SAFETY PLAN. | | | | | | 14) THE FIRE ALARM SYSTEM IS TO BE | | | UL LISTED FOR CENTRAL STATION SERVICE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
16:22 |
Sent To |
B |
|
| Notes |
| 2004-07-22 00:00:00 | TO RB DESK/TO ISSUE PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-02 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-18 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2004-05-18 00:00:00 | TO COMM BD#38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-08 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2004-04-08 00:00:00 | TO COMM BD#38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-25 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-14 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2003-12-11 00:00:00 | WILL CHECK WITH MICHELLE MCLEAN RE: | | | STATUS OF ZONING REVIEW (SEE FRONT | | | SCREEN NOTE DATED 11/25/03) | | 2003-11-25 00:00:00 | TO COMM BD#37 | | 2003-11-14 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-26 |
Time |
06:55 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-05-25 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2004-05-26 00:00:00 | PROVISO: | | | 1.ADDITIONAL PERMITS REQUIRED FOR THE | | | HOOD & FIRE SUPPRESSION.PLEASE PROVIDE | | | PLANS WITH PERMIT APPLICATION. | | | | | | 2.PROVIDE SUBMITTAL FOR TESTING OF | | | THE CO SENSORS PRIOR TO FINAL INSPECTION | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-10 |
Time |
08:25 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-04-10 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2004-04-10 00:00:00 | DENIED: | | | 1.PLAN SHEET M1.1 OUTSIDE AIR CALC FOR | | | AHU 4 INDICATES 1 CFM PER SQ FT.PER | | | 2001 FBC (M) 403.4.1 MINIMUM VENTILATION | | | SHALL BE 5 CFM PER PERSON OR 1.5 CFM PER | | | SQ FT. | | | | | | 2.PLAN SHEET M2.1 KEY NOTE #7 | | | INDICATES CO SENSOR SHALL BE SET AT 40 | | | PPM.PER 2001 FBC(M) 403.4 CO SENORS | | | SHALL BE SET AT 25 PPM.PLEASE CLARIFY. | | | | | | SEE ALSO COMMENTS FROM ASST FIRE | | | MARSHALL, MIKE CARSILLO. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-09 |
Time |
09:11 |
Rev Time |
4.00 |
| Received By |
pkrauss |
Date |
2003-12-09 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2003-12-09 00:00:00 | DENIED: | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | 1.OUTSIDE AIR CALCUALTIONS PER 2001 | | | FBC(M) 403.3, FOR ALL AREAS. | | | | | | 2.AHU #3 NOT LOCATION NOT SHOWN ON | | | THE PLAN (MECH RM 106?). | | | | | | 3.CU-5 INDICATED ON PLAN SHEET M2.1 | | | AND IS NOT LISTED ON THE EQUIPMENT | | | SCHEDULE ON SHEET M4.1.PLEASE CLARIFY. | | | | | | 4.VENTILATION FANS 6 & 7.PLEASE | | | CLARIFY WHEN THESE FANS ARE IN OPERATION | | | (WHILE ROLL-UP DOORS ARE CLOSED/OPEN?). | | | WILL THE APPARATUS BAY HAVE MECHANICAL | | | EXHAUST WHEN THE DOORS ARE CLOSED? | | | | | | 5.PLAN SHEET A2.3 INDICATES 2 KITCHEN | | | SUPPLY FANS AND NO KITCHEN EXHAUST. | | | PLEASE NOTE, 10 FT SEPARATION BETWEEN | | | EXHAUST TERMINATION & FRESH AIR INTAKES | | | OR HORIZONTALLY FROM PARTS FOR THE SAME | | | OR CONTIGUOUS BUILDINGS (REFERENCE A7.2 | | | EXHAUST FAN DETAIL). | | | | | | 6.ADDITIONAL PERMIT REQUIRED FOR HOOD | | | AND FIRE SUPPRESSION.PLEASE PROVIDE | | | THE FOLLOWING INFORMATION WITH PERMIT | | | APPLICATION. | | | A) PLANS INDICATING DUCT LAYOUT | | | B) TERMINATION OF EXHAUST | | | C) CLEARANCE TO COMBUSTIBLES PER NFPA | | | 96 1-3.2 & 2001 FBC(M)506.3.8. | | | D) MANUFACTURER SUBMITTAL FOR THE HOOD | | | E) EXHAUST FAN SHALL BE A HINGED | | | UPBLAST. (DETAIL M3.3) | | | F) SHOW COMPLIANCE WITH NFPA 96 & | | | FBC(M) 506. | | | | | | 7. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAS CODE | | | SECS. 502 THRU 506. | | | | | | 8.PLAN SHEET P2.1 INDICATES FUEL OIL | | | DAY TANK.SHEET E4.1 INDICATES THE DAY | | | TANK IS A SUBBASE TO THE GENERATOR - | | | PLEASE CLARIFY. | | | | | | 9.ADDITIONAL PERMIT REQUIRED FOR FUEL | | | OIL. | | | | | | 10. PROVIDE PIPING DETAIL FOR THE | | | CONDENSATE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-25 |
Time |
10:06 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2004-05-22 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-12 |
Time |
13:45 |
Rev Time |
5.00 |
| Received By |
kstevens |
Date |
2004-04-12 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2004-04-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: CONTACT RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE, INDUST- | | | RIAL PRETREATMENT FOR SIZING OF OIL/ | | | WASTE INTERCEPTOR. WASTE ORD. #2938-96. | | | (561) 837-4074. - RESPONSE NOTED BUT NOT | | | SURE WHAT WAS REVISED. PLEASE CLARIFY. | | | 2) CLARIFICATION OF RESPONSE CONCERNING | | | THE WATER SUPPLY TO FOUNTAIN. PLEASE IN- | | | DICATE IF THE WATER SUPPLY TO FOUNTAIN | | | WILL BE DIRECT TO FOUNTAIN OR WILL IT BE | | | FILLED BY HOSE FROM A HOSE BIBB. IF | | | DIRECTLY TIED IN A BACKFLOW WILL BE RE- | | | QUIRED ON THE SUPPLY LINE. | | | 3) IRRIGATION SHEETS, A CERTIFICATE OF | | | AUTHORIZATION NUMBER IS REQUIRED ON THE | | | TITLE BLOCK PER FS 481.219(2)(3) | | | 4) SHTS P2.1, P2.3, (DETAIL 7), & P3.1 | | | THE TRIAGE SINK SHALL NOT DRAIN THROUGH | | | THE WET VENTED HORIZONTAL DRAIN FOR THE | | | BATHROOM FIXTURES. SECTION 909.1 THE | | | SINK SHALL DISCHARGE DOWNSTREAM OF THE | | | BATHROOM FIXTURES. | | | 5) SHTS P2.1, & P3.1 (SANITARY RISER | | | DIAGRAM), THE FLOOR DRAIN IN ROOM #145 | | | BY THE COMPRESSOR REQUIRES A VENT. | | | SECTION 901.2.1 | | | 6) SHTS P2.1, P2.3 (DETAIL 5), & P3.1 | | | SANITARY RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN. FLOOR DRAIN OUTSIDE THE | | | SHOWERS IS NOT SHOWN ON RISER DIAGRAM. | | | 7) SHT 3.2 WATER RISER DIAGRAM. WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9 (AT WASH MACHINE, ICE MAKERS, AND | | | DISH WASHER), OR ANY OTHER QUICK CLOSING | | | VALVES SHALL BE SHOWN ON RISER DIAGRAM. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES IN AN "EFFECTIVE RANGE | | | NOT IN THE CEILING. PDI-WH 201 AND MANUF | | | INSTALLATION INSTRUCTIONS. | | | 8) SHT P3.2 GAS ISOMETRIC RISER DIAGRAM, | | | 2" PIPE REQUIRED UP TO WHERE THE LINE TO | | | THE STOVE/RANGE CONNECTS TO THE GAS MAIN | | | (INFORMATIONAL - 1" MINIMUM REQUIRED TO | | | WATER HEATER "2 - SHOWS 1-1/4" NOW). | | | 9-ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-08 |
Time |
06:08 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-12-08 |
Time |
06:08 |
Sent To |
|
|
| Notes |
| 2003-12-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 FUEL GAS | | | FLA. ADMIN. CODE | | | FLA STATUTES | | | | | | 1) SHTS C-2.1 & C-4.1 WATER SERVICE IN- | | | DICATES A PRESSURE VAC BREAKER ON THE | | | WATER SERVICE. AN RPZ BACKFLOW IS REQ- | | | UIRED. 608.13.2 | | | 2) CONTACT RODNEY COMPO, ENVIRONMENTAL | | | COMPLIANCE, INDUSTRIAL PRETREATMENT FOR | | | SIZING OF OIL/WATER INTECEPTOR. WASTE | | | ORD. #2938-96. (561) 837-4074 | | | 3) SHT L1 MORE INFORMATION REQUIRED ON | | | THE FOUNTAIN. WILL THERE BE DRAINAGE OR | | | WATER SUPPLIED TO THE FOUNTAIN? | | | 4) SEPARATE PLANS/PERMIT REQUIRED FOR | | | IRRIGATION. | | | 5) SHT A2.4 EQUIPMENT & ACCESSORIES SHC- | | | EDULE. CLAIRFY #42 GAS LINE OUTLET, IS | | | THIS NATURAL GAS, OR A FUEL LINE FOR THE | | | TRUCKS? | | | 6) SHT A5.1 TOILET ROOMS #113 & 122 | | | SHOWER STALLS SHALL BE ACCESSIBLE. SHOW | | | BENCH REQUIRED IN STALLS. | | | 7) SHT A5.1 DRINKING FOUNTAIN SHALL BE | | | ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH 11-4.15 AND ALL SUB- | | | SECTIONS. ALSO SHOW COMPLIANCE WITH | | | 11-4.1.3(10)(A) PROVISI0NS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | 8) SHT P2.2 THE FOLLOWING INFORMATION | | | WILL BE REQUIRED FOR GAS PERMIT APPLIC- | | | ATION. (SEPARATE PERMIT REQUIRED) | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | C. TYPE OF GAS, (LP OR NATURAL) | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | I. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | J. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | 9) SHT P2.3 INDIRECT WASTE FOR ICE MAKER | | | SHALL BE A FLOOR SINK. FLOOR DRAINS ARE | | | NOT APPROVED FOR INDIRECT WASTE. 802.3 | | | 10) SHT P2.3 KITCHEN/DINING ROOM. IN- | | | DIRECT WASTE REQUIRED FOR ICE MAKER ON | | | THE COUNTER. SUBMIT A DETAIL. 802.1.1 | | | 11) PLANS SHALL BE SIGNED. SEALED, AND | | | DATED BY THE ENGINEER/ARCHITECT OF REC- | | | ORD. INCLUDE ALL LICENSE NUMBERS ON | | | TITLE BLOCK AND CERTIFICATE OF AUTHOR- | | | IZATION IF APPLICABLE. 61G15-23.002/FS | | | 471.025 - 61G1-16.003-.004/FS481.2055 | | | 12) OTHER COMMENTS MAY FOLLOW AS THIS | | | PLAN REVIEW SHOWS THAT PLANS ARE ONLY | | | 90% COMPLETE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-02 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-02 |
Time |
15:27 |
Sent To |
I |
|
| Notes |
| 2004-06-02 00:00:00 | APPROVED BY ROBIN SINGER, PLANNING & | | | ZONING ADMINISTRATOR 659-8031 MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-04-22 |
Time |
15:59 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-04-22 00:00:00 | 2ND CHECKLIST | | | 1. PERCENTAGE OF OPENING IN FACADE ARE | | | REQUIRED TO BE BETWEEN 25 & 45%. | | | CALCULATION INDICATE 12.85% | | | 2. PLEASE DIMENSION FULL WIDTH OF S/W | | | UPUBLIC & PRIVATE) MIN. 8' REQUIRED | | | 3. INDICATE PARKING CALCULATIONS ON PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-11 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-13 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | DENIED BY ROBIN SINGER - NEED A FULLY | | | DIMENSIONED SITEPLAN TO COMPLETE REVIEW. | | | PARKING SPACES, DRIVE ASLES & LANDSCAPE | | | BUFFERS NOT DIMENSION. | | | - PARKING SPACES MUST BE DOUBLE STRIPED | | | DETAIL C4.3 SHOWS SINGLE STRIPING | | | -FENCE GATE EXCEEDS ALLOWABLE HEIGHT | | | (72"+10% OF HEIGHT FOR DECOATIVE ELEMENT | | | -34 PARKING SPACES REQUIRED, 30SHOWN. | | | PLEASE PROVIDE PARKING CALCUATIONS | | | -MAIN PEDESTIAN ENTRY MUST FACE THE | | | SHEET. SUGGEST OPENING UP ENTRY NEXT TO | | | OFFICE @ TOWER.RAILING SHOWN ON | | | ELEVATION BUT DOES NOT SHOW UPON SITE OR | | | FLOORPLAN PLEASE CLARIFY. | | | -NEED CALCULATIONS FOR % OF OPENINGS IN | | | FACADE | | | -PLEASE PROVIDE LANDSCAPE CALCULATIONS. | | | BASED ON OPEN SPACE & LINEAR BUFFER 101- | | | 118 TREES.PLANS SHOWS 79 TREES | | | -BUFFER WALL NEXT TO RESIDENTIAL SHOULD | | | DROP TO 30", 20FT FRON 49TH & 50TH ST | | | -VARIANCES TO NUMMERIAL & DIMENSIONAL | | | REQUIREMENTS ARE POSSIBLE NEED THE | | | ABOVE INFORMATION TO DETERMINE WHAT | | | VARIANCE ARE NECESSARY | | | - MECHANICAL EQUIPMENT MUST BE SCREENED | | | BACK IS NOT | | | -8FT SIDEWALK REQ'D ALONG BROADWAY | | 2003-11-25 00:00:00 | 11/25/03 ZONING WILL REVIEW LAST MM |
|
|