Plan Review Details - Permit 03110555
Plan Review Stops For Permit 03110555
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-24 Cont ID  
Sent By rmcdouga Date 2004-03-24 Time 13:29 Rev Time 0.50
Received By rmcdouga Date 2004-03-24 Time 13:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-16 Cont ID  
Sent By pkrauss Date 2004-03-24 Time 10:24 Rev Time 2.00
Received By rmcdouga Date 2004-03-16 Time 14:13 Sent To  
Notes
2004-03-16 00:00:00BUILDING PROVISO
  
 SUBMIT STATE OR LOCAL PRODUCT APPROVAL
 FOR THE STORM PANELS TO BE REVIEWED
 BEFORE THEY ARE INSTALLED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-22 Cont ID  
Sent By pkrauss Date 2004-03-10 Time 10:19 Rev Time 2.50
Received By rmcdouga Date 2003-12-22 Time 15:35 Sent To  
Notes
2003-12-22 00:00:00DENIED
  
 1) SUBMIT A COPY OF THE COVENANTS THAT
 HAS BEEN AMENDED AND RECORDED WITH PALM
 BEACH COUNTY TO CREATE AN EMERGENCY
 EGRESS THROUGH THE ADJOINING LOT ON THE
 ZERO LOT LINE SIDE OF THE STRUCTURE. THE
 DECLARATION OF COVENANTS THAT WAS
 SUBMITTED HAS NOT BEEN AMENDED TO
 SPECIFY AN UNOBSTRUCTED EGRESS EASEMENT
 FROM THE EGRESS WINDOWS ON THE ZERO LOT
 LINE SIDE OF THE HOUSE TO THE PUBLIC WAY
 IN FACT ITEM D SECTION 7 ALLOWS
 TRELLISES, BBQS, SCREEN ENCLOSURES AND
 DECORATIVE WATER FOUNTAINS TO BE WITHIN
 THE 3' EASEMENT. THIS IS NOT ACCEPTABLE.
 NOTE:
 1001.1.3/ 1005.4 ZERO LOT LINE EGRESS
 EGRESS:WHEN ACCESS TO OR FROM A RE-
 QUIRED EMERGENCY ESCAPE AND RESCUE OPEN-
 ING OF A STRUCTURE TO THE PUBLIC WAY,
 REQUIRES TRANSVERSING A PROPERTY
 (ADJOINING LOT) THAT IS NOT PART OF THE
 ONE WHICH THE STRUCTURE IS LOCATED, AN
 EGRESS EASEMENT THROUGH THE ADJOINING
 PROPERTY IS REQUIRED AND SHALL BE RECORD
 ED IN THE COUNTY RECORDS. THIS EASEMENT
 SHALL BE A MINIMUM OF 3' WIDE AND NOTH-
 ING SHALL BE PLACED WITHIN THE EASEMENT
 AREA WHICH WOULD BLOCK ACCESS TO THE
 EASEMENT AND OR IMPEDE EMERGENCY EGRESS
 FROM THE RESCUE OPENING TO THE PUBLIC
 WAY. NO LANDSCAPING, FENCES OR OTHER
 IMPEDIMENTS SHALL BE INSTALLED IN THIS
 EASEMENT.
  
 2) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL ON CITY
 FORM PER RULE 9B-72. SEE ATTACHMENT.
  
 3) SAFEGUARD STORM PANELS ARE NO LONGER
 IN BUSINESS AND DO NOT HAVE A VALID
 PRODUCT EVALUATION. SUBMIT STORM PANEL
 INFORMATION FROM A COMPANY WITH A STATE
 OR LOCAL PRODUCT APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-26 Cont ID  
Sent By btrobaug Date 2003-11-26 Time 09:41 Rev Time 0.50
Received By btrobaug Date 2003-11-26 Time 09:41 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-19 Cont ID  
Sent By csiegber Date 2004-03-19 Time 12:20 Rev Time 0.00
Received By csiegber Date 2004-03-19 Time 12:20 Sent To M
Notes
2004-03-19 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-03-01 Time 11:42 Rev Time 0.00
Received By csiegber Date 2004-03-01 Time 11:42 Sent To M
Notes
2004-03-01 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-22 Cont ID  
Sent By mmclean Date 2004-03-16 Time 14:12 Rev Time 0.00
Received By rmcdouga Date 2003-11-12 Time 16:24 Sent To  
Notes
2003-11-18 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-03-24 Cont ID  
Sent By pkrauss Date 2004-03-24 Time 10:23 Rev Time 0.33
Received By pkrauss Date 2004-03-24 Time 10:23 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-03-10 Cont ID  
Sent By csiegber Date 2004-03-19 Time 12:20 Rev Time 0.25
Received By pkrauss Date 2004-03-10 Time 10:16 Sent To B
Notes
2004-03-10 00:00:00DENIED:
 RETURN AIR JUMPER FROM THE MASTER
 BEDROOM IS NOT SIZED PROPERLY.PER THE
 REVISION TO THE 2001 FBC(M) 601.4
 EFFECTIVE JUNE 30, 2003, ALL SUPPLY AIR
 INTO THE MASTER SUITE (BATHROOM,
 CLOSET, ETC) IS TO BE INCLUDED IN THE
 CALCULATION FOR A "TOTAL" OF SUPPLY AIR
 TO THAT AREA.SEE THE ATTACHED
 SCHEDULE FOR PROPER SIZING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-12-03 Cont ID  
Sent By csiegber Date 2004-03-01 Time 11:42 Rev Time 0.50
Received By hmoser Date 2003-12-03 Time 18:23 Sent To P
Notes
2003-12-03 00:00:00PLAN DENIED
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 3) MECHANICAL PLAN AND FLOOR PLAN DO NOT
 MATCH
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-06 Cont ID  
Sent By hmoser Date 2003-12-03 Time 18:23 Rev Time 0.33
Received By jleech Date 2003-12-06 Time 06:10 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-11-17 Cont ID  
Sent By csiegber Date 2003-11-12 Time 16:24 Rev Time 0.00
Received By mmclean Date 2003-11-17 Time 14:03 Sent To I
Notes
***NONE***