Plan Review Details - Permit 03110111
Plan Review Stops For Permit 03110111
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-05-24 Cont ID  
Sent By alange Date 2004-05-24 Time 09:03 Rev Time 0.50
Received By alange Date 2004-05-24 Time 09:03 Sent To  
Notes
2004-05-24 00:00:00RECEIVED SUBMITTALS OK...ALANGE

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-04-23 Cont ID  
Sent By csiegber Date 2004-05-21 Time 13:21 Rev Time 2.00
Received By shill Date 2004-04-23 Time 09:02 Sent To  
Notes
2004-04-23 00:00:00****CORRECTIONS****
 REVISION & PRODUCT APPROVALS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)REVISED SHEETS ADDRESSING PROVISOS
 #1 AND 2 WERE REVIEWED, FOUND TO
 BE CODE COMPLIANT AND STAMPED.
  
 2.)SEPARATE PERMIT FOR SHUTTERS.
  
 3.)THE PRODUCT APPROVALS FOR THE
 CONNECTORS ARE DIFFICULT TO REVIEW.
 PLEASE PROVIDE A LIST OF THE CONNECTORS
 USED AND PROVIDE STATEWIDE PRODUCT
 APPROVAL FOR THOSE CONNECTORS.
  
 4.)SEE THE PREVIOUS LIST IN REGARDS
 TO THE ENGINEER'S COMPLIANCE WITH
 FAC61G15-23.002.ALTHOUGH HE ADDED THIS
 INFORMATION TO THE SHEETS AS REQUESTED,
 OTHER DOCUMENTS HAVE BEEN SUBMITTED
 WHICH ARE NOT IN COMPLIANCE.THIS IS
 A REQUIREMENT FOR DOCUMENTS PREPARED
 BY AN ENGINEER.THIS APPLIES TO THE
 RESPONSE TO PREVIOUS COMMENT #3, THE
 ALTERNATE FASTENER CALCULATIONS.
  
 5.)SITE SPECIFIC PRODUCT APPROVALS
 WERE SUBMITTED FOR THE ROYALL WALL
 PRODUCT.THE PAPERWORK WAS NOT IN
 COMPLIANCE WITH FAC9B-72.HOWEVER, MY
 UNDERSTANDING IS THAT THIS PRODUCT CAN
 BE APPROVED UNDER FBC103.7.ADDRESS.
  
 6.)ADDITIONAL FEES DUE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-12-29 Cont ID  
Sent By pkrauss Date 2004-04-19 Time 13:05 Rev Time 1.00
Received By shill Date 2003-12-29 Time 16:44 Sent To  
Notes
2003-12-29 00:00:00*****PROVISO*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE ENGINEER'S NAME AND LICENSE
 NUMBER IS TO BE PRINTED ON THE PLAN
 FAC61G15-23.002.REVISE SHEETS
 1,3,4,6,RF1, 1,SD1,SD2.
  
 2.)HHGT1 AND HHGT2, CONNECTOR KST260,
 NAILING CONFLICTS WITH CATALOG AND
 DESIGN UPLIFT ON PLAN EXCEEDS MAX
 ALLOWED BY THE CATALOG.REVISE RF1.
  
 3.)WOOD TO WOOD CONNECTORS ARE
 USED IN WOOD TO MASONRY APPLICATION;
 ADDRESS.REVISE RF1 OR SUBMIT
 CALCULATIONS.
  
 4.)SUBMIT SITE SPECIFIC OR STATEWIDE
 PRODUCT APPROVAL FOR THE FOLLOWING:
 GARAGE DOOR
 GLASS BLOCK
 SHUTTERS
 FIXED GLASS
  
 ******SUBMIT REVISIONS BEFORE FRAMING
 INSPECTION********

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-05 Cont ID  
Sent By csiegber Date 2003-12-29 Time 10:46 Rev Time 1.50
Received By sthyng Date 2003-12-04 Time 11:21 Sent To  
Notes
2003-12-04 00:00:00*****CORRECTIONS*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE ENGINEER'S NAME AND LICENSE
 NUMBER IS TO BE PRINTED ON THE PLAN,
 FAC61G15-23.002.
  
 2.)THE GIRDER/WALL CONNECTION (SHEET
 3) SPECIFIES HUGHES CONNECTORS; HUGHES
 IS NO LONGER IN BUSINESS.
  
 3.)THE WOOD CONSTRUCTION NOTES, ITEM
 #4, REFERS TO FBC3218.17.NOT IN THE
 FBC CODE BOOK.
  
 4.)HHGT1 AND HHGT2, CONNECTOR KST260
 SHEET RF1, NAILING CONFLICTS WITH
 CATALOG AND DESIGN UPLIFT ON THE PLAN
 EXCEEDS MAX ALLOWED BY THE CATALOG
 (USE THE GREY BAR WITHOUT STRESS
 INCREASE FOR STEEL, USP2003 CATALOG).
  
 5.)WOOD-TO-WOOD CONNECTORS ARE
 SPECIFIED IN WOOD-TO MASONRY
 APPLICATIONS; FOR EXAMPLE, USP HTW.
 ADDRESS (SHEET RF1).CHECK ALL
 CONNECTORS.
  
 6.)PROVIDE A FIREBLOCK DETAIL FOR THE
 DROPPED CEILINGS/SOFFITS, FBC705.3,
 2305.1.4.
  
 7.)STATEWIDE, LOCAL OR SITE SPECIFIC
 PRODUCT APPROVALS REQUIRED FOR THE
 FOLLOWING:
 GARAGE DOOR
 GLASS BLOCK
 SHUTTERS
 TRUSS CONNECTORS
 FIXED GLASS
 FIXED GLASS IMPACT
 FOR THE ABOVE ITEMS, PROVIDE COVER SHEET
 OF THE STATEWIDE PRODUCT APPROVAL, IF
 AVAILABLE, WITH THE NOA OR SBCCI REPORT.
 PRODUCT APPROVAL ALSO REQUIRED FOR
 CONNECTORS.PROVIDE A SCHEDULE OF
 CONNECTORS WITH THE STATE APPROVAL
 NUMBER LISTED.
  
 FOR MORE INFORMATION,
 WWW.FLORIDABUILDING.ORG.
  
 8.)THE ARCHITECTURALS ARE FOR A
 GARAGE LEFT, SITE PLAN AND STRUCTURALS
 FOR GARAGE RIGHT.
  
 9.)ADDITIONAL FEES DUE, RADON, SEE
 ATTACHED BZ231386.
  
 10.) AFFINITI ARCHITECTS SHOULD NOT BE
 ON THE PLAN IF THE PLAN IS SEALED BY
 ANOTHER ARCHITECT.REMOVE AFFINITI'S
 TITLE BLOCK FROM THE PLAN.
  
 11.)SAFEGUARD (STORM SHUTTER SBCCI
 REPORT) IS NO LONGER IN BUSINESS. SUBMIT
 VALID PRODUCT APPROVALS FOR STORM
 SHUTTERS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-13 Cont ID  
Sent By btrobaug Date 2003-11-13 Time 18:28 Rev Time 0.50
Received By btrobaug Date 2003-11-13 Time 18:17 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-05-21 Cont ID  
Sent By csiegber Date 2004-05-21 Time 13:21 Rev Time 0.00
Received By csiegber Date 2004-05-21 Time 13:21 Sent To B
Notes
2004-05-21 00:00:00TO SH DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 10:08 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 10:08 Sent To M
Notes
2004-04-14 00:00:00TO PK BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-29 Cont ID  
Sent By csiegber Date 2003-12-29 Time 10:46 Rev Time 0.00
Received By csiegber Date 2003-12-29 Time 10:46 Sent To B
Notes
2003-12-29 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-24 Cont ID  
Sent By mmclean Date 2003-12-24 Time 15:32 Rev Time 0.00
Received By csiegber Date 2003-12-24 Time 09:44 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-04 Cont ID  
Sent By sthyng Date 2003-12-04 Time 11:27 Rev Time 0.00
Received By sthyng Date 2003-11-04 Time 13:53 Sent To  
Notes
2003-11-05 00:00:00TO SFD RACK/E
2003-11-04 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-04-19 Cont ID  
Sent By pkrauss Date 2004-04-19 Time 13:05 Rev Time 0.30
Received By pkrauss Date 2004-04-19 Time 12:41 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-12-03 Cont ID  
Sent By csiegber Date 2004-04-14 Time 10:08 Rev Time 0.50
Received By hmoser Date 2003-12-03 Time 15:54 Sent To P
Notes
2003-12-03 00:00:00PROVISO
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-03 Cont ID  
Sent By hmoser Date 2003-12-03 Time 15:55 Rev Time 0.33
Received By jleech Date 2003-12-03 Time 16:55 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-12-24 Cont ID  
Sent By mmclean Date 2003-12-24 Time 15:32 Rev Time 0.00
Received By mmclean Date 2003-12-24 Time 15:32 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-11-05 Cont ID  
Sent By csiegber Date 2003-12-24 Time 09:44 Rev Time 0.00
Received By mmclean Date 2003-11-05 Time 16:02 Sent To  
Notes
2003-11-05 00:00:0011/5/03 DENIED, NEED TO HAVE SURVEY/
 MECH/FLOOR PLAN MATCHING CALLED VINCE
 & LEFT MSG ON VOICE MAIL MM