Plan Review Details - Permit 03110106
Plan Review Stops For Permit 03110106
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-05-13 Cont ID  
Sent By shill Date 2004-05-13 Time 16:39 Rev Time 1.00
Received By shill Date 2004-05-13 Time 16:39 Sent To  
Notes
2004-05-13 00:00:00****CORRECTIONS****
 PROVISO SUBMITTALS
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SHEET M1 HAS BEEN REVIEWED FOR
 CODE COMPLIANCE AND STAMPED.ALSO
 REVIEWED WERE THE PRODUCT APPROVALS FOR
 GLASS BLOCK,FIXED WINDOW, GARAGE DOORS.
  
 2.)IT IS UNCLEAR AS TO WHAT CHANGES
 WERE MADE ON THE ARCHITECTURALS. CHANGES
 ARE TO BE DATED AND CLEARLY INDICATED.
  
 3.)THE CONNECTORS WHICH HAVE BEEN
 APPROVED FOR USE IN A WOOD-TO-WOOD
 APPLICATION CANNOT BE USED IN A WOOD-TO-
 CONCRETE OR WOOD-TO-STEEL APPLICATION.
 CONNECTORS CAN BE ENGINEERED.REVISE
 STRUCTURAL SHEETS AS NECESSARY.
  
 4.)SEPARATE PERMIT FOR SHUTTERS.
  
 5.)SITE SPECIFIC PRODUCT APPROVAL
 WAS SUBMITTED FOR THE ROYALL WALL.THE
 PAPERWORK IS NOT IN COMPLIANCE WITH
 RULE 9B-72.SEE ATTACHED POLICY IN
 REGARDS TO ROYALL WALL.
  
 6.)REVISIONS SHOULD BE SUBMITTED AS
 SUCH, NOT AS SUBMITTALS.ADDITIONAL
 FEES DUE.
  
 7.)SEPARATE PERMIT FOR SHUTTERS.
  
 8.)SUBMIT STATEWIDE, LOCAL OR SITE
 SPECIFIC PRODUCT APPROVAL FOR THE
 OUTSWING GLAZED DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-12-30 Cont ID  
Sent By pkrauss Date 2004-04-26 Time 10:42 Rev Time 1.00
Received By shill Date 2003-12-30 Time 08:32 Sent To  
Notes
2003-12-30 00:00:00****PROVISO*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)HHGT1 AND HHGT2, CONNECTOR KST260,
 NAILING CONFLICTS WITH CATALOG AND
 DESIGN UPLIFT ON PLAN EXCEEDS MAX
 ALLOWED BY THE CATALOG.REVISE RF1.
  
 2.)WOOD TO WOOD CONNECTORS ARE USED
 IN WOOD TO MASONRY APPLICATION; ADDRESS.
 REVISE RF1 OR SUBMIT CALCULATIONS.
  
 3.)SUBMIT SITE SPECIFIC OR STATEWIDE
 PRODUCT APPROVALS FOR THE FOLLOWING:
 GARAGE DOOR
 GLASS BLOCK
 SHUTTERS
 FIXED GLASS
  
 *****SUBMIT REVISIONS BEFORE FRAMING
 INSPECTION******

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-08 Cont ID  
Sent By csiegber Date 2003-12-29 Time 09:24 Rev Time 2.00
Received By shill Date 2003-12-08 Time 15:24 Sent To  
Notes
2003-12-08 00:00:00*****CORRECTIONS******
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE ENGINEER'S NAME AND LICENSE
 NUMBER IS TO BE PRINTED ON THE PLAN,
 FAC6115-23.002.
  
 2.)THE GIRDER/WALL CONNECTION (SHEET
 3) SPECIFIES HUGHES CONNECTORS; HUGHES
 IS NO LONGER IN BUSINESS.
  
 3.)THE WOOD CONSTRUCTION NOTES, ITEM
 #4, REFERS TO FBC3218.17.NOT IN THE
 FBC CODE BOOK.
  
 4.)HHGT1 AND HHGT2, CONNECTOR KST260
 SHEET RF1, NAILING CONFLICTS WITH
 CATALOG AND DESIGN UPLIFT ON THE PLAN
 EXCEEDS MAX ALLOWED BY THE CATALOT
 (USE THE GREY BAR WITHOUT STRESS
 INCRESE FOR STEEL, USP 2003 CATALOG).
 CHECK ALL CONNECTORS.
  
 5.)WOOD-TO-WOOD CONNECTORS ARE
 SPECIFIED IN WOOD-TO-MASONRY
 APPLICATIONS; FOR EXAMPLE, USP HTW.
 ADDRESS. (SHEET RF1).
  
 6.)PROVIDE A FIREBLOCK DETAIL FOR
 THE DROPPED CEILINGS/SOFFITS, FBC
 705.3, 2305.1.4.
  
 7.)STATEWIDE, LOCAL OR SITE
 SPECIFIC APPROVALS REQUIRED FOR WINDOWS,
 DOORS, TRUSS CONNECTORS, ROOF, SHUTTERS.
 FOR MORE INFORMATION ,
 WWW.FLORIDABUILDING.ORG.
  
 8.)ADDITIONAL FEES DUE (RADON).
  
 9.)REMOVE THE TITLE BLOCK FOR AFFINITI
 AS THEY ARE NOT THE DESIGNER OF
 RECORD.
  
 10.) SAFEGUARD (STORM SHUTTER SBCCI
 REPORT) IS NO LONGER IN BUSINESS.
 SUBMIT VALID PRODUCT APPROVALS.
  
 11.) THE ARCHITECTURALS ARE GARAGE
 LEFT, STRUCTURALS ARE GARAGE RIGHT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-18 Cont ID  
Sent By btrobaug Date 2003-11-18 Time 07:56 Rev Time 0.50
Received By btrobaug Date 2003-11-18 Time 07:56 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pkrauss Date 2004-05-25 Time 12:08 Sent To  
Notes
2004-05-25 00:00:00SENT TO SAMANTHA HILL, BUILDING PLAN
 REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 09:19 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 09:19 Sent To M
Notes
2004-04-14 00:00:00TO PK BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-29 Cont ID  
Sent By csiegber Date 2003-12-29 Time 09:24 Rev Time 0.00
Received By csiegber Date 2003-12-29 Time 09:24 Sent To B
Notes
2003-12-29 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-24 Cont ID  
Sent By mmclean Date 2003-12-24 Time 15:27 Rev Time 0.00
Received By csiegber Date 2003-12-24 Time 09:22 Sent To Z
Notes
2003-12-24 00:00:00TO Z/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-08 Cont ID  
Sent By csiegber Date 2003-11-05 Time 16:17 Rev Time 0.00
Received By shill Date 2003-11-04 Time 12:25 Sent To  
Notes
2003-11-05 00:00:00TO SFD RACK/E
2003-11-04 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-04-26 Cont ID  
Sent By pkrauss Date 2004-04-26 Time 10:42 Rev Time 0.40
Received By pkrauss Date 2004-04-26 Time 10:42 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-12-01 Cont ID  
Sent By csiegber Date 2004-04-14 Time 09:19 Rev Time 0.50
Received By hmoser Date 2003-12-01 Time 19:03 Sent To P
Notes
2003-12-01 00:00:001) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-03 Cont ID  
Sent By hmoser Date 2003-12-01 Time 19:04 Rev Time 0.33
Received By jleech Date 2003-12-03 Time 19:00 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-12-24 Cont ID  
Sent By mmclean Date 2003-12-24 Time 15:27 Rev Time 0.00
Received By mmclean Date 2003-12-24 Time 15:27 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-11-05 Cont ID  
Sent By csiegber Date 2003-12-24 Time 09:22 Rev Time 0.00
Received By mmclean Date 2003-11-05 Time 16:11 Sent To  
Notes
2003-11-05 00:00:0011/5/03 DENIED, NEED TO HAVE SURVEY/
 FLOOR PLAN/MECH PLAN MATCHING CALLED
 VINCE LEFT MSG ON VOICE MAIL MM