| Plan Review Stops For Permit 03110106 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-13 |
Time |
16:39 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-05-13 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2004-05-13 00:00:00 | ****CORRECTIONS**** | | | PROVISO SUBMITTALS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SHEET M1 HAS BEEN REVIEWED FOR | | | CODE COMPLIANCE AND STAMPED.ALSO | | | REVIEWED WERE THE PRODUCT APPROVALS FOR | | | GLASS BLOCK,FIXED WINDOW, GARAGE DOORS. | | | | | | 2.)IT IS UNCLEAR AS TO WHAT CHANGES | | | WERE MADE ON THE ARCHITECTURALS. CHANGES | | | ARE TO BE DATED AND CLEARLY INDICATED. | | | | | | 3.)THE CONNECTORS WHICH HAVE BEEN | | | APPROVED FOR USE IN A WOOD-TO-WOOD | | | APPLICATION CANNOT BE USED IN A WOOD-TO- | | | CONCRETE OR WOOD-TO-STEEL APPLICATION. | | | CONNECTORS CAN BE ENGINEERED.REVISE | | | STRUCTURAL SHEETS AS NECESSARY. | | | | | | 4.)SEPARATE PERMIT FOR SHUTTERS. | | | | | | 5.)SITE SPECIFIC PRODUCT APPROVAL | | | WAS SUBMITTED FOR THE ROYALL WALL.THE | | | PAPERWORK IS NOT IN COMPLIANCE WITH | | | RULE 9B-72.SEE ATTACHED POLICY IN | | | REGARDS TO ROYALL WALL. | | | | | | 6.)REVISIONS SHOULD BE SUBMITTED AS | | | SUCH, NOT AS SUBMITTALS.ADDITIONAL | | | FEES DUE. | | | | | | 7.)SEPARATE PERMIT FOR SHUTTERS. | | | | | | 8.)SUBMIT STATEWIDE, LOCAL OR SITE | | | SPECIFIC PRODUCT APPROVAL FOR THE | | | OUTSWING GLAZED DOORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-26 |
Time |
10:42 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2003-12-30 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | ****PROVISO***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)HHGT1 AND HHGT2, CONNECTOR KST260, | | | NAILING CONFLICTS WITH CATALOG AND | | | DESIGN UPLIFT ON PLAN EXCEEDS MAX | | | ALLOWED BY THE CATALOG.REVISE RF1. | | | | | | 2.)WOOD TO WOOD CONNECTORS ARE USED | | | IN WOOD TO MASONRY APPLICATION; ADDRESS. | | | REVISE RF1 OR SUBMIT CALCULATIONS. | | | | | | 3.)SUBMIT SITE SPECIFIC OR STATEWIDE | | | PRODUCT APPROVALS FOR THE FOLLOWING: | | | GARAGE DOOR | | | GLASS BLOCK | | | SHUTTERS | | | FIXED GLASS | | | | | | *****SUBMIT REVISIONS BEFORE FRAMING | | | INSPECTION****** |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-29 |
Time |
09:24 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2003-12-08 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2003-12-08 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE ENGINEER'S NAME AND LICENSE | | | NUMBER IS TO BE PRINTED ON THE PLAN, | | | FAC6115-23.002. | | | | | | 2.)THE GIRDER/WALL CONNECTION (SHEET | | | 3) SPECIFIES HUGHES CONNECTORS; HUGHES | | | IS NO LONGER IN BUSINESS. | | | | | | 3.)THE WOOD CONSTRUCTION NOTES, ITEM | | | #4, REFERS TO FBC3218.17.NOT IN THE | | | FBC CODE BOOK. | | | | | | 4.)HHGT1 AND HHGT2, CONNECTOR KST260 | | | SHEET RF1, NAILING CONFLICTS WITH | | | CATALOG AND DESIGN UPLIFT ON THE PLAN | | | EXCEEDS MAX ALLOWED BY THE CATALOT | | | (USE THE GREY BAR WITHOUT STRESS | | | INCRESE FOR STEEL, USP 2003 CATALOG). | | | CHECK ALL CONNECTORS. | | | | | | 5.)WOOD-TO-WOOD CONNECTORS ARE | | | SPECIFIED IN WOOD-TO-MASONRY | | | APPLICATIONS; FOR EXAMPLE, USP HTW. | | | ADDRESS. (SHEET RF1). | | | | | | 6.)PROVIDE A FIREBLOCK DETAIL FOR | | | THE DROPPED CEILINGS/SOFFITS, FBC | | | 705.3, 2305.1.4. | | | | | | 7.)STATEWIDE, LOCAL OR SITE | | | SPECIFIC APPROVALS REQUIRED FOR WINDOWS, | | | DOORS, TRUSS CONNECTORS, ROOF, SHUTTERS. | | | FOR MORE INFORMATION , | | | WWW.FLORIDABUILDING.ORG. | | | | | | 8.)ADDITIONAL FEES DUE (RADON). | | | | | | 9.)REMOVE THE TITLE BLOCK FOR AFFINITI | | | AS THEY ARE NOT THE DESIGNER OF | | | RECORD. | | | | | | 10.) SAFEGUARD (STORM SHUTTER SBCCI | | | REPORT) IS NO LONGER IN BUSINESS. | | | SUBMIT VALID PRODUCT APPROVALS. | | | | | | 11.) THE ARCHITECTURALS ARE GARAGE | | | LEFT, STRUCTURALS ARE GARAGE RIGHT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-18 |
Time |
07:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-18 |
Time |
07:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-05-25 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2004-05-25 00:00:00 | SENT TO SAMANTHA HILL, BUILDING PLAN | | | REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-14 |
Time |
09:19 |
Sent To |
M |
|
| Notes |
| 2004-04-14 00:00:00 | TO PK BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-29 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-29 |
Time |
09:24 |
Sent To |
B |
|
| Notes |
| 2003-12-29 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-24 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-24 |
Time |
09:22 |
Sent To |
Z |
|
| Notes |
| 2003-12-24 00:00:00 | TO Z/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-05 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2003-11-04 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | TO SFD RACK/E | | 2003-11-04 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-26 |
Time |
10:42 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-04-26 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-12-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-14 |
Time |
09:19 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-12-01 |
Time |
19:03 |
Sent To |
P |
|
| Notes |
| 2003-12-01 00:00:00 | 1) REFER TO SECTION 307.2.3 AUXILIARY | | | DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE | | | INSTALLED UNDER ALL COILS ON WITCH | | | CONDENSATION WILL OCCUR. | | | 2) RETURN AIR REQUIREMENTS TO COMPLY | | | WITH THE FLORIDA BUILDING CODE (M) 2003 | | | CHANGES.CHANGES WENT INTO EFFECT JULY 1 | | | 2003 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-12-01 |
Time |
19:04 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-12-03 |
Time |
19:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-24 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-12-24 |
Time |
15:27 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-24 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-11-05 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | 11/5/03 DENIED, NEED TO HAVE SURVEY/ | | | FLOOR PLAN/MECH PLAN MATCHING CALLED | | | VINCE LEFT MSG ON VOICE MAIL MM |
|
|