| Plan Review Stops For Permit 03110015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-01-30 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-30 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-30 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-13 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-13 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2) CONTRARY TO THE COMMENT RESPONSE, | | | THIS COMMENT HAS NOT BEEN ADDRESSED: | | | FBC 13-103.1.1.1THE ARCHITECT SHALL | | | ENTER HIS NAME AND LICENSE NUMBER ON | | | SHEET TWO OF THE SUBMITTED ENERGY CODE | | | COMPLIANCE FORM, TO CERTIFY COMPLIANCE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-04 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-04 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-04 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2003-12-04 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2) FBC 13-103.1.1.1THE ARCHITECT SHALL | | | ENTER HIS NAME AND LICENSE NUMBER ON | | | SHEET TWO OF THE ENERGY CODE COMPLIANCE | | | FORM, TO CERTIFY COMPLIANCE. | | | | | | 3) FBC 11-4.15DRINKING FOUNTAIN. | | | ADD DETAILS TO SHOW THE CODE REQUIRED | | | ACCESSIBLE APPROACH, SPOUT HEIGHT AND | | | LEG CLEARANCES FOR THE DRINKING FOUNTAIN | | | | | | 4) INCORPORATE THE NOTES REDLINED ON | | | SHEETS A-1 AND A-3. | | | | | | 5) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-25 |
Time |
11:59 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-25 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
12:55 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-03-05 |
Time |
05:36 |
Sent To |
|
|
| Notes |
| 2004-03-05 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANELS. | | | PANEL "P1A" NOT SHOWN ON RISER. | | | PANEL "L1A" IS SHOWN ON RISER AND NO | | | PANEL SCHEDULE AND IS NOT INCLUDED ON | | | "H1A". | | | | | | 2)NOTE; PLEASE CORRELATE LOAD CALCULAT- | | | -IONS. LOAD SUMMARY AND PANELS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
13:31 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-20 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-30 |
Time |
07:36 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-12-30 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | *********** UNSAT ****************** | | | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED BY | | | ENGINEER OF RECORD AS REQUESTED ON | | | PREVIOUS REVIEW. PER FS 471.025 AND | | | FAC 61G15-23.002 | | | ONCE AGAIN ONE SET OF ELECTRICAL AND | | | FIRE ALARM PLANS ARE BEING RETAINED FOR | | | RECORD FOR SAID CORRECTIONS. | | | | | | 2)NOTE: PLEASE ALSO SEE COPY OF | | | FS 553.80(2)(B) FOR CORRECTIONS TO BE | | | MADE WITH THE SAME COMMENTS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-04 |
Time |
14:33 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-11-04 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | PLEASE SEE THAT ONE SET IS BEING KEPT | | | FOR RECORD OF SAID CORRECTIONS. | | 2003-11-04 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 215.3, 230.42 ETC. | | | | | | 2)NOTE: PLEASE HAVE PLANS "SIGNED" | | | BY THE ENGINEER OF RECORD. IN ORDER TO | | | VERIFY AUTHENTICITY OF ENGINEER'S WORK, | | | AND SIGNATURE PER FS 471.025 PLANS AND | | | REVISIONS WILL BE REQ'D TO BE SIGNED | | | WITH A COMPLETE SIGNATURE INSTEAD OF | | | INITIALS. PLEASE ALSO SEE FAC 61G15-23. | | | 002. | | | THE ABOVE MAY BE SUBMITTED TO THE FBPE | | | FOR REVIEW AND INTERPERTAION. | | | BLDG OFFICAL HAS ALSO RULED THAT PLANS | | | MUST BE SIGNED AND NOT A PRINTED | | | INITIALS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-29 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-29 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-14 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-14 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2003-11-14 00:00:00 | 1) FIRE ALARM NOTES # 17 IS INCORRECT. | | | WHEN ACTIVATED, THE DUCT SMOKE DETECTOR | | | SHALL CAUSE AN ALARM NOT A SUPERVISORY | | | SIGNAL. | | | | | | 2) FIRE ALARM NOTES # 19 IS INCORRECT. | | | FIRE ALARM CIRCUITS SHALL BE CLASS A, | | | STYLE D, OR FULLY ADDRESSABLE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
12:55 |
Sent To |
E |
|
| Notes |
| 2004-03-11 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
13:31 |
Sent To |
E |
|
| Notes |
| 2004-02-27 00:00:00 | TO COMM BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-16 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-16 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | TO COMM BD#29 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-17 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2003-12-17 00:00:00 | TO COMM BD#30 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-01-30 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-03 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | TO COMM BD#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-11 |
Time |
12:38 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-03-11 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-06 |
Time |
07:51 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-01-06 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-05 |
Time |
07:12 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-12-05 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2003-12-05 00:00:00 | ONLY ONE SET OF PLANS - | | | 1.SEE COMMENT 1 FROM FIRE DEPARTMENT | | | IN REGARDS TO THE DUCT SMOKE DETECTOR. | | | | | | 2.THE ENERGY CALCULATIONS SUBMITTED | | | INDICATE 0 FOR THE MAXIMUM TONNAGE. | | | | | | PLEASE REVISE AND RESUBMIT 2 COPIES FOR | | | APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-11-25 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2003-11-25 00:00:00 | NEED TWO SETS OF PLANS | | | PLAN PRVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-09 |
Time |
16:49 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-09 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-12-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-06 |
Time |
05:45 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-12-06 |
Time |
05:45 |
Sent To |
|
|
| Notes |
| 2003-12-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHTS A-1 & A-3 SHOW TURNING RADIUS IN | | | TOILET ROOMS. 11-4.22.3 | | | 2) SHT A-1 & A-3 DOORS SHALL NOT SWING | | | INTO THE CLEAR FLOOR SPACE REQUIRED FOR | | | ANY FIXTURE. | | | 3) SHTS A-1 & A-3 SHOW CLEAR FLOOR SPACE | | | FOR BREAK ROOM SINK. | | | 4) SHT A-3 SUBMIT A DETAIL FOR DRINKING | | | FOUNTAIN SHOWING WITH 11-4.15 AND ALL | | | SUBSECTIONS. | | | 5) SHT P0.1 DOMESTIC WATER ISOMETRIC. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES IN AN "EFFECTIVE RANGE | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | AND MANUF INSTALLATION INSTRUCTIONS. | | | 6) SHTS P0.1 & P2.1 SANT. RISER AND | | | FLOOR PLAN. BREAK ROOM SINK SHALL TIE IN | | | DOWNSTREAM OF BATHROOM FIXTURES. 909.1 | | | 7) SIGNATURE REQUIRED ON SEAL PER FAC | | | 61G15-23.002(1). INITALS NOT APPROVED | | | PER BUILDING OFFICIAL & FBPE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|