| Plan Review Stops For Permit 03101853 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2003-12-29 |
Time |
18:08 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2003-12-29 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2003-12-29 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)SEE PREVIOUS LIST.THE LICENSE | | | NUMBER OF SJE (ENGINEERING | | | AUTHORIZATION NUMBER) IS TO BE ON THE | | | PLAN, BOTH ENGINEERING NUMBER AND THE | | | GENERAL CONTRACTOR NUMBER ARE | | | DELINQUENT.ADDRESS. | | | | | | 3.)SEE PREVIOUS LIST, ITEM #5.HOW | | | IS THE "NEW DEN" NEW?ENCLOSED PORCH, | | | PARTITION WALL, ADDITION?ENERGY CALCS | | | AND IMPACT FEES (233-5025) MAY BE | | | REQUIRED. | | | | | | 4.)PREINSPECT REQUIRED, 805-6666 TO | | | SCHEDULE. | | | | | | 5.)SEE PREVIOUS LIST, ITEM #7 IN | | | REGARDS TO WORK ON THE "FRONT ROOF" NOT | | | SHOWN ON THE PLAN. | | | | | | 6.)SEE PREVIOUS LIST, SUBMIT TWO | | | COPIES OF PRODUCT APPROVALS FOR THE | | | WOOD DOOR.STATEWIDE OR SITE SPECIFIC | | | REQUIRED IN ADDITION TO TEST REPORT, | | | WWW.FLORIDABUILDING.ORG. | | | | | | 7.)THE FLOOR PLAN DOES NOT MATCH THE | | | SURVEY.ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-29 |
Time |
16:21 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-11-13 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2003-11-13 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG (HILL) | | | BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)SUBMIT TWO COPIES OF ALL PLANS | | | AND SPECIFICATIONS FOR PERMITTING. | | | | | | 3.)THE LICENSE NUMBERS OF SJE ARE | | | REQUIRED TO BE ON THE PLAN.BOTH | | | LICENSE NUMBERS, ENGINEERING AND | | | CONTRACTING, ARE DELINQUENT.ADDRESS. | | | | | | 4.)PROVIDE A WALL SECTION SHOWING | | | HOW THE REPAIR WILL BE DONE, FBC104.3.1. | | | 1, WALL SECTION FROM THE FOUNDATION | | | THROUGH THE ROOF INCLUDING ASSEMBLY | | | AND MATERIALS. | | | | | | 5.)THE PLAN SHOWS A "NEW DEN".HOW IS | | | THIS ROOM "NEW"?ENCLOSED PORCH, | | | PARTITION WALL, ADDITION?SHOW ON THE | | | PLAN. | | | | | | 6.)PREINSPECT REQUIRED, CALL 805-6666 | | | TO SCHEDULE. | | | | | | 7.)THE APPLICATION REFERS TO RED TAGS | | | FOR "FRONT ROOF", BUT NO WORK TO THE | | | FRONT ROOF IS SHOWN ON THE PLAN.IF IT | | | INVOLVES STRUCTURAL WORK, SHOW ON THE | | | PLAN.IF IT IS ROOF WORK, A SEPARATE | | | ROOFING PERMIT IS REQUIRED AND WILL NOT | | | BE A PART OF THIS PERMIT. | | | | | | 8.)SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR THE WOOD DOOR.FOR A | | | STATEWIDE LIST OF APPROVED PRODUCTS, | | | SEE WWW.FLORIDABUILDING.ORG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-21 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-01-21 |
Time |
11:31 |
Sent To |
M |
|
| Notes |
| 2004-01-21 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} 61G15-23.002 FAC REQUIRES AN ADDRESS | | | ON THE TITLE BLOCK. | | | | | | 2} PLEASE NOTE THAT LOAD CALCULATIONS | | | MUST COMPLY WITH 220.31(B) WHEN USING | | | THE OPTIONAL METHOD FOR AN EXISTING | | | RESIDENCE. | | | | | | 3} PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | 20AMP & #12 WIRE,SEE ARTICLE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-15 |
Time |
14:54 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-17 |
Time |
08:33 |
Sent To |
M |
|
| Notes |
| 2003-12-17 00:00:00 | | | | FAILED | | | ~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | SEE NOTES FROM PREVIOUS REVIEW THAT | | | WERE NOT ADDRESSED. | | | | | | 1} LOAD CALCULATIONS PER 230.31(B).NOTE | | | #2. | | | | | | 2} SMOKE DETECTORS MUST COMPLY WITH 210. | | | 12,MUST BE ARC FAULT PROTECTED. SEE NOTE | | | #4. | | | | | | 3} REFERRENCE TO "SPARK ARRESTOR DOES | | | NOT COMPLY WITH 210.12,SEE NOTE #5. | | | | | | 4} PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210-52C 1,2,3,4,AND 5.SEE NOTE #6. | | | | | | 5} PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S). PER 210.11.(C)(3) | | | MUST BE 20A AND #12AWG.SEE NOTE #7 | | | | | | 6} PLEASE NOTE FRONT AND REAR | | | RECEPTS REQ`D PER 210.52E,SEE NOTE #8. | | | | | | 7} SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | IN THE VICINITY OF BEDROOMS AND CLOSE | | | PROXIMITY OF STAIRWAYS. 2-5.2.1.3 | | | 3'FT FROM BATHS/KITCHENS.2-5.2.1.6 | | | | | | NOTE THAT THE KITCHEN IS LABELED AS | | | "EXISTING BEDROOM". | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | PREVIOUS NOTES ARE ATTACHED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:28 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-11-06 |
Time |
13:50 |
Sent To |
M |
|
| Notes |
| 2003-11-06 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | 1} PLEASE NOTE THAT ALL PLANS THAT ARE | | | SIGNED AND SEALED BY AN ENGINEER ARE | | | REQUIRED PER 61G15-23.002 FAC TO HAVE A | | | TITLE BLOCK COMPLYING WITH SAID | | | ARTICLE.THIS HAS BEEN AN ISSUE ON | | | PREVIOUS PLANS THAT WERE SUBMITTED FOR | | | REVIEW.WE ARE RETAINING A SET OF PLANS | | | TO BE FILED AND TURNED INTO THE FBPE | | | FOR DISCIPLINARY ACTION. | | | | | | 2} NOTE THAT THE LOAD CALCULATIONS MUST | | | BE AS PER 230.31(B) WHEN USING THE | | | OPTIONAL METHOD FOR AN EXISTING | | | RESIDENCE. | | | | | | 3} THE AIC RATING ON THE PANEL IS 10000 | | | AND THE NOTE ON THE RISER INDICATES | | | 22000. PLEASE CLARIFY. | | | | | | 4} THE NOTE INDICATING SMOKE DETECTORS | | | BEING FED FROM KITCHEN OR BATH CIRCUITS | | | DOES NOT COMPLY WITH ART.210.12 2002 | | | NEC. MUST BE ARC FAULT PROTECTED IN THE | | | BEDROOMS. | | | | | | 5} THE REFERENCE TO "SPARK ARRESTOR"IS | | | INCORRECT AND NOT IN COMPLIANCE WITH | | | 210.12. | | | | | | 6} PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210-52C 1,2,3,4,AND 5,AND GFI PER | | | 210.8(A)(6),INDICATE SAME ON PLANS. | | | | | | 7} PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S). PER 210.11.(C)(3). | | | MUST BE 20A AND #12AWG. | | | | | | 8} PLEASE NOTE FRONT AND REAR | | | RECEPTS REQ`D PER 210.52E | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-15 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-15 |
Time |
14:54 |
Sent To |
E |
|
| Notes |
| 2004-01-15 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-16 |
Time |
12:28 |
Sent To |
E |
|
| Notes |
| 2003-12-16 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-10-31 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-10-31 |
Time |
09:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-21 |
Time |
12:25 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-12-29 |
Time |
16:17 |
Sent To |
B |
|
| Notes |
| 2003-12-29 00:00:00 | DENIED: | | | 1.RETURN AIR NOT INDICATED FROM 2 OF | | | THE EXISTING BEDROOM AREAS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-29 |
Time |
14:08 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-11-07 |
Time |
06:38 |
Sent To |
P |
|
| Notes |
| 2003-11-07 00:00:00 | DENIED: | | | 1.RETURN AIR REQUIRED FROM BEDROOM | | | AREAS AS PER REVISION TO THE 2001 FBC(M) | | | 601.4.SEE ATTACHED FOR PROPER SIZING | | | OF RETURN AIR OR TRANSFER GRILLES. | | | | | | 2.PLEASE NOTE, PLAN INDICATES THE | | | KITCHEN AREA AS A BEDROOM. | | | | | | 3.SEE COMMENT #1 BY ELECTRICAL PLAN | | | REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-21 |
Time |
12:25 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-12-29 |
Time |
14:07 |
Sent To |
M |
|
| Notes |
| 2003-12-29 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-07 |
Time |
06:43 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-11-07 |
Time |
17:48 |
Sent To |
B |
|
| Notes |
| 2003-11-07 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|