Plan Review Stops For Permit 03101853
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-12-29 Cont ID  
Sent By shill Date 2003-12-29 Time 18:08 Rev Time 1.00
Received By shill Date 2003-12-29 Time 18:08 Sent To  
Notes
2003-12-29 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)SEE PREVIOUS LIST.THE LICENSE
 NUMBER OF SJE (ENGINEERING
 AUTHORIZATION NUMBER) IS TO BE ON THE
 PLAN, BOTH ENGINEERING NUMBER AND THE
 GENERAL CONTRACTOR NUMBER ARE
 DELINQUENT.ADDRESS.
  
 3.)SEE PREVIOUS LIST, ITEM #5.HOW
 IS THE "NEW DEN" NEW?ENCLOSED PORCH,
 PARTITION WALL, ADDITION?ENERGY CALCS
 AND IMPACT FEES (233-5025) MAY BE
 REQUIRED.
  
 4.)PREINSPECT REQUIRED, 805-6666 TO
 SCHEDULE.
  
 5.)SEE PREVIOUS LIST, ITEM #7 IN
 REGARDS TO WORK ON THE "FRONT ROOF" NOT
 SHOWN ON THE PLAN.
  
 6.)SEE PREVIOUS LIST, SUBMIT TWO
 COPIES OF PRODUCT APPROVALS FOR THE
 WOOD DOOR.STATEWIDE OR SITE SPECIFIC
 REQUIRED IN ADDITION TO TEST REPORT,
 WWW.FLORIDABUILDING.ORG.
  
 7.)THE FLOOR PLAN DOES NOT MATCH THE
 SURVEY.ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-13 Cont ID  
Sent By pkrauss Date 2003-12-29 Time 16:21 Rev Time 1.00
Received By sthyng Date 2003-11-13 Time 18:30 Sent To  
Notes
2003-11-13 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG (HILL)
 BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)SUBMIT TWO COPIES OF ALL PLANS
 AND SPECIFICATIONS FOR PERMITTING.
  
 3.)THE LICENSE NUMBERS OF SJE ARE
 REQUIRED TO BE ON THE PLAN.BOTH
 LICENSE NUMBERS, ENGINEERING AND
 CONTRACTING, ARE DELINQUENT.ADDRESS.
  
 4.)PROVIDE A WALL SECTION SHOWING
 HOW THE REPAIR WILL BE DONE, FBC104.3.1.
 1, WALL SECTION FROM THE FOUNDATION
 THROUGH THE ROOF INCLUDING ASSEMBLY
 AND MATERIALS.
  
 5.)THE PLAN SHOWS A "NEW DEN".HOW IS
 THIS ROOM "NEW"?ENCLOSED PORCH,
 PARTITION WALL, ADDITION?SHOW ON THE
 PLAN.
  
 6.)PREINSPECT REQUIRED, CALL 805-6666
 TO SCHEDULE.
  
 7.)THE APPLICATION REFERS TO RED TAGS
 FOR "FRONT ROOF", BUT NO WORK TO THE
 FRONT ROOF IS SHOWN ON THE PLAN.IF IT
 INVOLVES STRUCTURAL WORK, SHOW ON THE
 PLAN.IF IT IS ROOF WORK, A SEPARATE
 ROOFING PERMIT IS REQUIRED AND WILL NOT
 BE A PART OF THIS PERMIT.
  
 8.)SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR THE WOOD DOOR.FOR A
 STATEWIDE LIST OF APPROVED PRODUCTS,
 SEE WWW.FLORIDABUILDING.ORG.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-01-21 Cont ID  
Sent By btrobaug Date 2004-01-21 Time 11:49 Rev Time 0.50
Received By btrobaug Date 2004-01-21 Time 11:31 Sent To M
Notes
2004-01-21 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} 61G15-23.002 FAC REQUIRES AN ADDRESS
 ON THE TITLE BLOCK.
  
 2} PLEASE NOTE THAT LOAD CALCULATIONS
 MUST COMPLY WITH 220.31(B) WHEN USING
 THE OPTIONAL METHOD FOR AN EXISTING
 RESIDENCE.
  
 3} PLEASE LIST ALL THE REQ'D
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3
 20AMP & #12 WIRE,SEE ARTICLE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-12-17 Cont ID  
Sent By csiegber Date 2004-01-15 Time 14:54 Rev Time 0.50
Received By btrobaug Date 2003-12-17 Time 08:33 Sent To M
Notes
2003-12-17 00:00:00 
 FAILED
 ~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 SEE NOTES FROM PREVIOUS REVIEW THAT
 WERE NOT ADDRESSED.
  
 1} LOAD CALCULATIONS PER 230.31(B).NOTE
 #2.
  
 2} SMOKE DETECTORS MUST COMPLY WITH 210.
 12,MUST BE ARC FAULT PROTECTED. SEE NOTE
 #4.
  
 3} REFERRENCE TO "SPARK ARRESTOR DOES
 NOT COMPLY WITH 210.12,SEE NOTE #5.
  
 4} PLEASE NOTE KITCHEN COUNTER-
 -SPACE RECEPT SPACING SHALL MEET ART;
 210-52C 1,2,3,4,AND 5.SEE NOTE #6.
  
 5} PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S). PER 210.11.(C)(3)
 MUST BE 20A AND #12AWG.SEE NOTE #7
  
 6} PLEASE NOTE FRONT AND REAR
 RECEPTS REQ`D PER 210.52E,SEE NOTE #8.
  
 7} SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 IN THE VICINITY OF BEDROOMS AND CLOSE
 PROXIMITY OF STAIRWAYS. 2-5.2.1.3
 3'FT FROM BATHS/KITCHENS.2-5.2.1.6
  
 NOTE THAT THE KITCHEN IS LABELED AS
 "EXISTING BEDROOM".
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
 PREVIOUS NOTES ARE ATTACHED.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-11-06 Cont ID  
Sent By csiegber Date 2003-12-16 Time 12:28 Rev Time 1.00
Received By btrobaug Date 2003-11-06 Time 13:50 Sent To M
Notes
2003-11-06 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 1} PLEASE NOTE THAT ALL PLANS THAT ARE
 SIGNED AND SEALED BY AN ENGINEER ARE
 REQUIRED PER 61G15-23.002 FAC TO HAVE A
 TITLE BLOCK COMPLYING WITH SAID
 ARTICLE.THIS HAS BEEN AN ISSUE ON
 PREVIOUS PLANS THAT WERE SUBMITTED FOR
 REVIEW.WE ARE RETAINING A SET OF PLANS
 TO BE FILED AND TURNED INTO THE FBPE
 FOR DISCIPLINARY ACTION.
  
 2} NOTE THAT THE LOAD CALCULATIONS MUST
 BE AS PER 230.31(B) WHEN USING THE
 OPTIONAL METHOD FOR AN EXISTING
 RESIDENCE.
  
 3} THE AIC RATING ON THE PANEL IS 10000
 AND THE NOTE ON THE RISER INDICATES
 22000. PLEASE CLARIFY.
  
 4} THE NOTE INDICATING SMOKE DETECTORS
 BEING FED FROM KITCHEN OR BATH CIRCUITS
 DOES NOT COMPLY WITH ART.210.12 2002
 NEC. MUST BE ARC FAULT PROTECTED IN THE
 BEDROOMS.
  
 5} THE REFERENCE TO "SPARK ARRESTOR"IS
 INCORRECT AND NOT IN COMPLIANCE WITH
 210.12.
  
 6} PLEASE NOTE KITCHEN COUNTER-
 -SPACE RECEPT SPACING SHALL MEET ART;
 210-52C 1,2,3,4,AND 5,AND GFI PER
 210.8(A)(6),INDICATE SAME ON PLANS.
  
 7} PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S). PER 210.11.(C)(3).
 MUST BE 20A AND #12AWG.
  
 8} PLEASE NOTE FRONT AND REAR
 RECEPTS REQ`D PER 210.52E
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-01-15 Time 14:54 Rev Time 0.00
Received By csiegber Date 2004-01-15 Time 14:54 Sent To E
Notes
2004-01-15 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-16 Cont ID  
Sent By csiegber Date 2003-12-16 Time 12:28 Rev Time 0.00
Received By csiegber Date 2003-12-16 Time 12:28 Sent To E
Notes
2003-12-16 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-31 Cont ID  
Sent By lsmith Date 2003-10-31 Time 09:29 Rev Time 0.00
Received By lsmith Date 2003-10-31 Time 09:29 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-12-29 Cont ID  
Sent By btrobaug Date 2004-01-21 Time 12:25 Rev Time 0.33
Received By pkrauss Date 2003-12-29 Time 16:17 Sent To B
Notes
2003-12-29 00:00:00DENIED:
 1.RETURN AIR NOT INDICATED FROM 2 OF
 THE EXISTING BEDROOM AREAS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-11-07 Cont ID  
Sent By kstevens Date 2003-12-29 Time 14:08 Rev Time 0.33
Received By pkrauss Date 2003-11-07 Time 06:38 Sent To P
Notes
2003-11-07 00:00:00DENIED:
 1.RETURN AIR REQUIRED FROM BEDROOM
 AREAS AS PER REVISION TO THE 2001 FBC(M)
 601.4.SEE ATTACHED FOR PROPER SIZING
 OF RETURN AIR OR TRANSFER GRILLES.
  
 2.PLEASE NOTE, PLAN INDICATES THE
 KITCHEN AREA AS A BEDROOM.
  
 3.SEE COMMENT #1 BY ELECTRICAL PLAN
 REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status N Date 2003-12-29 Cont ID  
Sent By btrobaug Date 2004-01-21 Time 12:25 Rev Time 0.25
Received By kstevens Date 2003-12-29 Time 14:07 Sent To M
Notes
2003-12-29 00:00:00NO PLUMBING PLANS SUBMITTED

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-11-07 Cont ID  
Sent By pkrauss Date 2003-11-07 Time 06:43 Rev Time 0.25
Received By kstevens Date 2003-11-07 Time 17:48 Sent To B
Notes
2003-11-07 00:00:00NO PLUMBING PLANS SUBMITTED