Plan Review Details - Permit 03101769
Plan Review Stops For Permit 03101769
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-19 Cont ID  
Sent By rmcdouga Date 2004-03-19 Time 16:00 Rev Time 0.50
Received By rmcdouga Date 2004-03-19 Time 16:00 Sent To  
Notes
2004-03-19 00:00:00RESTAMP PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-03-19 Time 12:11 Rev Time 1.00
Received By rmcdouga Date 2004-01-15 Time 15:28 Sent To  
Notes
2004-01-15 00:00:00PROVISO
  
 1) SUBMIT STATE PRODUCT APPROVAL FOR
 DOUBLE AND SINGLE OUTSWING GLAZED DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-19 Cont ID  
Sent By pkrauss Date 2004-01-15 Time 07:05 Rev Time 3.00
Received By rmcdouga Date 2003-11-19 Time 07:35 Sent To M
Notes
2003-11-19 00:00:00UNSAT
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE PERCENT OF WALL AREA ALLOWED AS
 OPENINGS BY FBC TABLE 600 IS EXCEEDED BY
 THE SLIDING GLASS DOOR AND TRANSOM IN
 THE BREAKFAST ROOM.
  
 4) THE ANCHOR SCHEDULE ON A5 LISTS USP
 TA20 CONNECTORS WITH (9) 10D X 1-1/2"
 NAILS. THE UPLIFT VALUES GIVEN IN THE
 SCHEDULE ARE FOR (9) 10D X 3" NAILS OR
 (10) 10D X 1-1/2" NAILS PER 2003 USP
 CATALOG. PLEASE CORRECT.
  
 5) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATIONS AFTER OCTOBER 1,2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE PRODUCT APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL
 FORM PER RULE 9B-72. SEE ATTACHMENT.
  
 6) SUBMIT PRODUCT APPROVAL FOR THE
 SINGLE OUTSWING GLAZED FRENCH DOOR.
  
 7) THE PRODUCT APPROVAL FOR THE 16'
 GARAGE DOOR IS EXPIRED.
  
 8) THE STORM PANELS ARE REQUIRED BY THE
 PRODUCT APPROVAL TO BE A MINIMUM OF 46"
 IN LENGTH. PLEASE REVISE THE ITEMS ON
 THE SCHEDULE THAT LIST SHUTTER SPANS OF
 LESS THAN 46" AS REQUIRED BY TABLE 5 ON
 PAGE 9 OF 9 OF THE DRAWINGS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-09 Cont ID  
Sent By dpalmer Date 2004-03-09 Time 11:42 Rev Time 0.33
Received By dpalmer Date 2004-03-09 Time 11:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-06 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:02 Rev Time 0.33
Received By dpalmer Date 2003-11-06 Time 15:04 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-03-19 Cont ID  
Sent By csiegber Date 2004-03-19 Time 12:11 Rev Time 0.00
Received By csiegber Date 2004-03-19 Time 12:11 Sent To B
Notes
2004-03-19 00:00:00TO RM DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-03 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:02 Rev Time 0.00
Received By csiegber Date 2004-03-03 Time 10:02 Sent To E
Notes
2004-03-03 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-12 Cont ID  
Sent By csiegber Date 2004-01-12 Time 09:21 Rev Time 0.00
Received By csiegber Date 2004-01-12 Time 09:21 Sent To M
Notes
2004-01-12 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-11-22 Cont ID  
Sent By mmclean Date 2003-10-31 Time 15:12 Rev Time 0.00
Received By csiegber Date 2003-10-29 Time 15:24 Sent To  
Notes
2003-11-03 00:00:00TO SFD RACK/E
2003-10-29 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-15 Cont ID  
Sent By pkrauss Date 2004-01-15 Time 07:04 Rev Time 0.33
Received By pkrauss Date 2004-01-15 Time 06:50 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-11-22 Cont ID  
Sent By csiegber Date 2004-01-12 Time 09:21 Rev Time 0.50
Received By hmoser Date 2003-11-22 Time 10:54 Sent To B
Notes
2003-11-22 00:00:00PLAN DENIED
 1) REFER TO RETURN AIR REQUIREMENTS
 FLORIDA BUILDING CODE 2003 CHANGES WENT
 INTO EFFECT JULY 1 2003.
 2) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PANS
 PLAM REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-11-08 Cont ID  
Sent By jleech Date 2003-11-08 Time 09:45 Rev Time 0.33
Received By jleech Date 2003-11-08 Time 09:45 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-31 Cont ID  
Sent By mmclean Date 2003-10-31 Time 15:12 Rev Time 0.00
Received By mmclean Date 2003-10-31 Time 15:12 Sent To I
Notes
***NONE***