Plan Review Details - Permit 03101736
Plan Review Stops For Permit 03101736
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By dpalmer Date 2004-04-27 Time 05:39 Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-03-19 Cont ID  
Sent By kstevens Date 2004-03-18 Time 17:20 Rev Time 0.33
Received By alange Date 2004-03-19 Time 11:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2004-05-26 Cont ID  
Sent By btrobaug Date 2004-05-26 Time 15:37 Rev Time 0.00
Received By btrobaug Date 2004-05-26 Time 15:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-27 Cont ID  
Sent By alange Date 2004-05-24 Time 14:50 Rev Time 0.25
Received By dpalmer Date 2004-04-27 Time 05:31 Sent To B
Notes
2004-04-27 00:00:00NO POOL HEATER SHOWN ON RISER/PLANS.
 ELECTRICAL SHEET STAMPED HOWEVER,
 PLUMB STILL SHOWS FAIL.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-03-18 Cont ID  
Sent By pschmitz Date 2004-04-26 Time 08:52 Rev Time 0.50
Received By btrobaug Date 2004-03-18 Time 13:54 Sent To P
Notes
2004-03-18 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 ALL CHANGES TO AN ENGINEERED DRAWING
 MUST BE MADE BY THE ENGINEER OF RECORD
 ART. 471 F.S..
  
 THE HEATER THAT WAS SCRATCHED OFF THE
 SPECIFICATION SHEET STILL APPEARS ON
 THE ELECTRICAL DIAGRAM. PLEASE
 CORRELATE PLANS WITH THE ENGINEER AND
 RESUBMIT FOR REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-03-11 Time 11:59 Rev Time 0.50
Received By btrobaug Date 2004-02-27 Time 10:58 Sent To B
Notes
2004-02-27 00:00:00 
 PLEASE PROVIDE LOAD CALCULATIONS SHOWING
 11K POOL HEATER AND VERIFY THE
 ELECTRICAL SERVICE IS ADEQUATE FOR ALL
 ADDED LOADS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-05-24 Cont ID  
Sent By alange Date 2004-05-24 Time 14:50 Rev Time 0.00
Received By alange Date 2004-05-24 Time 14:50 Sent To E
Notes
2004-05-24 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:21 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 11:21 Sent To P
Notes
2004-04-14 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-03-11 Cont ID  
Sent By csiegber Date 2004-03-11 Time 11:59 Rev Time 0.00
Received By csiegber Date 2004-03-11 Time 11:59 Sent To E
Notes
2004-03-11 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-02-20 Cont ID  
Sent By csiegber Date 2004-02-20 Time 09:09 Rev Time 0.00
Received By csiegber Date 2004-02-20 Time 09:08 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-11 Cont ID  
Sent By mmclean Date 2004-02-19 Time 14:44 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 14:12 Sent To Z
Notes
2004-02-11 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 16:55 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 16:55 Sent To Z
Notes
2004-01-21 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-02 Cont ID  
Sent By csiegber Date 2003-12-02 Time 16:33 Rev Time 0.00
Received By csiegber Date 2003-12-02 Time 16:33 Sent To Z
Notes
2003-12-02 00:00:00TO Z/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-29 Cont ID  
Sent By csiegber Date 2003-10-29 Time 09:52 Rev Time 0.00
Received By csiegber Date 2003-10-29 Time 09:52 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-04-26 Cont ID  
Sent By btrobaug Date 2004-05-26 Time 15:37 Rev Time 1.00
Received By pschmitz Date   Time   Sent To E
Notes
2004-04-25 00:00:00PLUMBING PLAN REVIEW, DENIED 3RD TIME.
 PREVIOUS NOTES 2,3 NOT ADDRESSED DATED
 03-08-04
 END OF COMMENTS, QUESTIONS 561--805-6692

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-03-18 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:21 Rev Time 0.33
Received By kstevens Date 2004-03-18 Time 17:19 Sent To B
Notes
2004-03-18 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA STATUTES.
 FBC-2001 CHAPTER 1
  
 1) ALL CHANGES TO A SIGNED AND SEALED
 SET OF PLANS SHALL BE SIGNED AND DATED
 BY ENGINEER OF RECORD.
 2) HEATER IS STILL SHOWN ON POOL PIPING
 SCHEMATIC. PIPING SCHEMATIC SHALL RE-
 FLECT THE POOL SPECIFICATIONS AND POOL
 LAYOUT. SECTION 104.2.1
 3) INFORMATIONAL - ALL POOL WORK SHALL
 NOT COMMENCE UNTIL AN RPZV BACKFLOW IS
 INSTALLED AND INSPECTED. SEPARATE PERMIT
 REQUIRED BY LICENSED PLUMBING CONTRACTOR
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-02-26 Cont ID  
Sent By btrobaug Date 2004-03-18 Time 13:59 Rev Time 0.50
Received By kstevens Date 2004-02-26 Time 17:23 Sent To B
Notes
2004-02-26 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 2) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 5 Status P Date 2004-02-19 Cont ID  
Sent By mmclean Date 2004-02-19 Time 14:44 Rev Time 0.00
Received By mmclean Date 2004-02-19 Time 14:44 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2004-02-11 Cont ID  
Sent By mmclean Date 2004-02-17 Time 15:23 Rev Time 0.00
Received By mmclean Date 2004-02-11 Time 15:23 Sent To  
Notes
2004-02-17 00:00:00DENIED, NEED CLARIFICATION ON THE
 SETBACKS FOR POOL & DECK CALLED PETER
 LEFT MSG FILE MM
 CALLED PETER FOR CLARIFICATION ON
 THE SETBACKS FOR POOL & DECK LEFT MSG

Review Stop Z ZONING
Rev No 3 Status F Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-02-11 Time 14:12 Rev Time 0.00
Received By mmclean Date 2004-01-27 Time 11:26 Sent To  
Notes
2004-01-27 00:00:00DENIED, NEED TO MEET THE REQUIRED
 SETBACKS CALLED PETER LEFT MSG MM

Review Stop Z ZONING
Rev No 2 Status F Date 2003-12-05 Cont ID  
Sent By csiegber Date 2004-01-21 Time 16:55 Rev Time 0.00
Received By mmclean Date 2003-12-05 Time 12:41 Sent To  
Notes
2003-12-05 00:00:00DENIED, POOL MUST BE 5' ON THE ZERO &
 NON-ZERO SIDE/DECK MUST BE 2' ON THE
 ZERO & NON-ZERO SIDE CALLED PETER FILE
 M MM

Review Stop Z ZONING
Rev No 1 Status F Date 2003-11-03 Cont ID  
Sent By csiegber Date 2003-12-02 Time 16:33 Rev Time 0.00
Received By mmclean Date 2003-10-29 Time 16:58 Sent To  
Notes
2003-11-03 00:00:0011/03 DENIED, SETBACKS ON POOL & DECK
 NOT CLEAR ON SURVEY. CALLED CONTR JOYCE
 10/31/03 & NO RETURN INFO FILE M MM


Account Summary | Usage Policy | Privacy Policy