Plan Review Details - Permit 03101544
| Plan Review Stops For Permit 03101544 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
11:34 |
Sent To |
M |
|
| Notes |
| 2003-11-06 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
16:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-07 |
Time |
07:41 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-11-07 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | PROVISO: | | | AUXILIARY DRAIN PAN REQUIRED PER 2001 | | | FBC(M) 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
11:34 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-10-29 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | DENIED: | | | 1.PLAN DOES NOT INDICATE MAIN OR BRANC | | | H DUCT SIZES. | | | | | | 2.RETURN AIR REQUIRED FROM BEDROOM | | | AREAS.PLEASE SIZE RETURN AS PER | | | REVISION TO THE 2001 FBC(M) 601.4, | | | EFFECTIVE JUNE 30,2003: | | | | | | RETURN AIR JUMPER SHALL BE SIZED 1 1/2 | | | TIMES THE CROSS SECTIONAL AREA OF THE | | | SUPPLY DUCT FOR THE ROOM ITS SERVING | | | WITH THE DOOR HAVING AN UNRESTRICTED 1" | | | UNDERCUT. (ALL SUPPLY AIR TO THE ROOM | | | SHALL BE CALCULATED) | | | | | | AIR TRANSFER GRILLES SHALL BE SIZED 50 | | | SQ INCHES PER 100 CFM SUPPLY AIR. | | | | | | 3.EMERGENCY DRAIN PAN REQUIRED AS PER | | | 2001 FBC(M) 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
|