| Plan Review Stops For Permit 03101500 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-01-16 |
Time |
16:13 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
2004-01-16 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | SUBMITTED STATE AND LOCAL PORDUCT | | | PRODUCT APPROVALS FOR WINDOWS.DOORS. | | | MULLIONS AND OH GARAGE DOOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-16 |
Time |
07:46 |
Rev Time |
2.50 |
| Received By |
rmcdouga |
Date |
2003-12-16 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | PROVISO | | | | | | 1) STORM PANELS TO BE UNDER SEPARATE | | | PERMIT. | | | | | | 2) SUBMIT STATEWIDE OR LOCAL PRODUCT | | | APPROVAL IN ACCORDANCE WITH FAC RULE 9B- | | | 72, FOR EXTERIOR WINDOWS, DOORS, GARAGE | | | DOOR AND MULLIONS FOR REVIEW PRIOR TO | | | THEIR INSTALLATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-12-04 |
Time |
11:39 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2003-12-04 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2003-12-04 00:00:00 | DENIED | | | | | | 1) THE PRODUCT APPROVAL FOR THE STORM | | | PANELS CONTAINS A PAGE OF SPAN TABLES | | | THAT STATES IT IS NOT VALID WITHOUT THE | | | RAISED SEAL OF THE ENGINEER (BENNARDO). | | | THE SPAN FOR A 3" EDGE DISTANCE IS NOT | | | IS NOT INDICATED IN THE LAST COLUMN OF | | | THE SPAN TABLE. SOME OF THE ANCHORS THAT | | | HAVE BEEN HIGHLIGHTED REQUIRE CLOSER | | | SPACING OF ANCHORS THAN INDICATED ON THE | | | INSTALLATION SCHEDULE. | | | | | | 2)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | SUBMIT STATE PRODUCT APPROVALS OR | | | APPLICATION FOR LOCAL SITE SPECIFIC | | | PRODUCT APPROVAL FOR WINDOWS AND DOORS. | | | | | | 3) ADDRESS MECHANICAL ISSUES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-03 |
Time |
14:31 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-11-18 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2003-11-18 00:00:00 | UNSAT | | | | | | 1) THE UPLIFT VALUES LISTED IN THE | | | CONCRETE TO TRUSS CONNECTOR SCHEDULE ON | | | SHEET A5A ARE INCORRECT FOR MULTIPLE | | | STRAPS. THE VALUES DO NOT DOUBLE FOR 2 | | | STRAPS OR TRIPLE FOR THREE DUE TO THE | | | PROXIMITY OF THE STRAPS AND CONE PULLOUT | | | OF THE CONCRETE. SEE THE SIMPSON CATALOG | | | EXAMPLE: (2) HETA 20 STRAPS EMBEDDED IN | | | A CONCRETE TIE BEAM HAS A UPLIFT VALUE | | | OF 2710# NOT 3030# LISTED IN THE SCHED. | | | ON THE PLANS. PLEASE REVISE. | | | | | | 2) PROVIDE A DETAIL INDICATING THE | | | ATTACHMENT OF THE WOOD FRAME INTERIOR | | | BEARING WALLS TO THE EXTERIOR MASONRY OR | | | CONCRETE WALLS. | | | | | | 3) AN (A5) CONCRETE TO TRUSS CONNECTOR | | | IS INCORRECTLY SPECIFIED AT THE WOOD | | | FRAME INTERIOR BEARING WALL AT THE | | | DINING ROOM ON SHEET A5A. PLEASE CORRECT | | | | | | 4) ON SHEET A5A SECTION 11 ON A8 IS | | | INDICATED AT THE INTERIOR KITCHEN WALL. | | | PLEASE CLARIFY. | | | | | | 5) PROVIDE (2) PRODUCT APPROVALS, KEY | | | PLANS AND INSTALLATION SCHEDULES | | | INDICATING THE SPECIFIC TYPES OF ANCHORS | | | TO BE USED FOR STORM PANELS. A SEPARATE | | | PERMIT WILL BE REQUIRED IF NOT SUBMITTED | | | AT THIS TIME. | | | | | | 6) PRODUCT APPROVALS FOR APPLICATIONS | | | SUBMITTED AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCT WITH | | | STATE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT A COMPLETED | | | APPLICATION FOR LOCAL PRODUCT APPROVAL | | | PER RULE 9B-72. SEE ATTACHMENT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-04 |
Time |
17:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-04 |
Time |
17:32 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-16 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-16 |
Time |
07:46 |
Sent To |
B |
|
| Notes |
| 2004-01-16 00:00:00 | TO RM DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-08 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-08 |
Time |
09:02 |
Sent To |
M |
|
| Notes |
| 2003-12-08 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-11-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-21 |
Time |
16:58 |
Sent To |
M |
|
| Notes |
| 2003-11-21 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-29 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | TO SFD RACK/E | | 2003-10-24 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-18 |
Time |
15:39 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-12-18 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2003-12-18 00:00:00 | APPROVED 12-15-03 PROVISO ON PLAN |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-08 |
Time |
09:03 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-12-03 |
Time |
13:44 |
Sent To |
B |
|
| Notes |
| 2003-12-03 00:00:00 | DENIED: | | | RETURN AIR SHALL COMPLY WITH REVISION | | | TO 2001 FBC(M) 601.4 EFFECTIVE JUNE 30, | | | 2003.(SEE ATTACHED FOR PROPER SIZING) | | | | | | PLEASE NOTE RETURN AIR DUCT FOR THE | | | MASTER BEDROOM SHALL BE 1 1/2 TIMES | | | THE TOTAL OF SUPPLY AIR TO THAT SPACE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
16:58 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-11-06 |
Time |
16:57 |
Sent To |
P |
|
| Notes |
| 2003-11-06 00:00:00 | PLAN DENIED | | | 1) RETURN REQUIREMENTS TO COMPLY WITH | | | THE F.B.C.(M) 2003 CHANGES.THE CHANGES | | | WENT INTO EFFECT JULY 1 2003. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-11-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-11-06 |
Time |
17:03 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-11-08 |
Time |
06:28 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-29 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-12-18 |
Time |
15:32 |
Sent To |
I |
|
| Notes |
| 2003-12-18 00:00:00 | PLEASE SEE PLANS FOR ZONING APPROVAL | | | BY MICHELLE M.SH |
|
|