| Plan Review Stops For Permit 03101273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2003-12-17 |
Time |
18:15 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2003-12-17 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | **OK TO REPLACE EX. BEDROOM WINDOWS | | | WITH SAME SIZE/TYPE PER NMK, SEE LETTER | | | IN FILE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-11-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-17 |
Time |
14:15 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-11-29 |
Time |
13:50 |
Sent To |
M |
|
| Notes |
| 2003-11-29 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)PROVIDE THE RECEIPT FOR IMPACT | | | FEES. | | | | | | 2.)SEE PREVIOUS LIST, ITEM #6, ATTIC | | | ACCESS REQUIRED.SHEET A2.0 SHOWS AN | | | EXISTING ATTIC ACCESS SERVING THE | | | EXISTING HOUSE.IF THE TRUSSES ARE TO | | | REMAIN, ACCESS TO THE NEW ATTIC AREA | | | (ADDITION) WILL NOT BE POSSIBLE.PLEASE | | | CALL ME TO CLARIFY IF NECESSARY. | | | | | | 3.)THE PRODUCT APPROVALS SUBMITTED, | | | KINCO SINGLE HUNG IMPACT WINDOW, ARE | | | ACCEPTABLE FOR SOME WINDOWS ON THE PLAN | | | BUT NOT FOR THE LARGER WINDOWS.THE | | | DESIGN PRESSURE FOR THE WINDOWS EXCEED | | | THE MAXIMUM DESIGN LOAD CAPACITY (SEE | | | THE PRODUCT APPROVAL, HIGHLIGHTED). | | | | | | 4.)THE THERMA-TRU DOOR HAS A STATUS | | | OF "PENDING" ON THE DCA WEBSITE.PER | | | THE FLORIDA BUILDING COMMISSION, WE | | | CANNOT ACCEPT PRODUCTS ON THE PENDING | | | LIST.THIS PERMIT CAN BE ISSUED WITH A | | | PROVISO THAT A SEPARATE PERMIT BE | | | OBTAINED FOR THE DOOR.THERE AREN'T ANY | | | EXTERIOR DOORS ON THE PLAN; IF YOU ARE | | | REPLACING AN EXISTING DOOR AND WISH FOR | | | IT TO BE COVERED UNDER THIS PERMIT, | | | REVISE YOUR PERMIT APPLICATION, | | | INDICATING WHICH DOOR IS BEING REPLACED. | | | | | | 5.)THE PLANS SHOW WINDOWS WHICH ARE | | | "EXISTING", BUT YOUR PERMIT APPLICATION | | | INDICATES "WINDOW REPLACEMENT".ARE | | | YOUR REPLACING ALL OF THE WINDOWS IN | | | THE HOUSE?IF YOU ARE, EXISTING | | | BEDROOMS WITH WINDOW BEING REPLACED | | | MUST COMPLY WITH FBC1005.4, EMERGENCY | | | EGRESS.THE SIZES SHOWN DO NOT COMPLY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-11-24 |
Time |
13:46 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-11-13 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2003-11-13 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG (HILL), BUILDING PLANS | | | EXMINER561-805-6724 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 3.)PROVIDE A COPY OF THE SURVEY FOR | | | THIS PROPERTY. | | | | | | 4.)ADDITIONAL FEES DUE, $3.38.SEE | | | ATTACHED BZ233268.(RADON FEES) | | | | | | 5.)PROVIDE ATTIC VENTILATION TO | | | COMPLY WITH FBC2309.7. | | | | | | 6.)ATTIC ACCESS REQUIRED, FBC2309. | | | | | | 7.)THE WINDOW SCHEDULE, A2.0, REFERS | | | TO THE STRUCTURAL DRAWINGS FOR DESIGN | | | PRESSURES.THEY ARE NOT ON THE | | | STRUCTURAL DRAWINGS; PROVIDE. | | | | | | 8.)EFFECTIVE OCTOBER 1, STATEWIDE | | | PRODUCT APPROVALS ARE REQUIRED.THE | | | LIST IS AVAILABLE ONLINE, PLEASE PROVIDE | | | THE STATEWIDE PRODUCT APPROVAL AS A | | | COVER SHEET TO THE PRODUCT APPROVALS | | | ALREADY REVIEWED BY HISTORIC | | | PRESERVATION DEPARTMENT. | | | WWW.FLORIDABUILDING.ORG (PRODUCT | | | APPROVAL, PRODUCT SEARCH). | | | | | | FOR MORE INFORMATION IN REGARDS TO THE | | | PROGRAM, SEE THE DCA WEBSITE AT: | | | WWW.DCA.STATE.FL.US/FHCD/FBC/COMMITTEES/ | | | PRODUCT_APPROVAL/1_PRODUCT_APPROVAL.HTM | | | | | | IN ADDITION TO THE STATEWIDE PRODUCT | | | APPROVAL REQUIRED FOR THE WINDOW, ALSO | | | SUBMIT PRODUCT APPROVALS FOR THE ROOF, | | | WINDOW MULLION, AND STRUCTURAL | | | COMPONENTS (WOOD CONNECTORS). | | | | | | ANY PRODUCT APPROVALS NOT SUBMITTED | | | BEFORE THE PERMIT IS ISSUED WILL | | | REQUIRE THAT A SEPARATE PERMIT BE | | | OBTAINED FOR THAT ITEM WITH ADDITIONAL | | | FEES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
11:22 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2004-04-23 00:00:00 | ** REDLINED ** | | | | | | COLD WATER PIPE | | | SUBMIT AIC RATING.110.9 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-17 |
Time |
13:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-11-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-21 |
Time |
15:29 |
Sent To |
P |
|
| Notes |
| 2003-11-21 00:00:00 | | | | DENIED | | | ~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | NOTE: PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, DATED | | | AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | ONLY ONE SET SIGNED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
11:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-10-27 |
Time |
12:19 |
Sent To |
P |
|
| Notes |
| 2003-10-27 00:00:00 | UNSAT | | | ~~~~~ | | | PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, DATED | | | AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
11:04 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-12 |
Time |
13:40 |
Sent To |
E |
|
| Notes |
| 2003-12-12 00:00:00 | TO BT DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-11-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-21 |
Time |
11:39 |
Sent To |
E |
|
| Notes |
| 2003-11-21 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
14:53 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-24 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-21 |
Time |
16:30 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-12-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-02 |
Time |
13:32 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-12-02 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-11-29 |
Time |
15:46 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-11-14 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2003-11-14 00:00:00 | SPOKE WITH OWNER BUILDER | | | #1 A/C PLAN ON THE ME SHEET. | | | #2 ENERGY CALCS ARE FOR THE SECOND FLOOR | | | #3 OKAY | | | #4 LOCATION OF THE AHU IS ON THE SECOND | | | FLOOR IN A CLOSET. | | | OWNER BUILDER WILL MAKE CORRECTIONS & | | | RESUBMIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-10-28 |
Time |
17:27 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-11-05 |
Time |
07:10 |
Sent To |
B |
|
| Notes |
| 2003-11-05 00:00:00 | DENIED: | | | 1.NO MECHANICAL PLANS SUBMITTED. | | | | | | 2.ENERGY CALCULATIONS INDICATE AN | | | ADDITION BUT WITH 1038 SQ FT OF | | | CONDITION SPACE. WILL THE A/C SYSTEM BE | | | INSTALLED FOR THE ENTIRE HOUSE OR JUST | | | THE ADDITION?MANUAL J CALCULATIONS ARE | | | FOR THE SECOND FLOOR ONLY. | | | | | | 3.PLEASE PROVIDE EQUIPMENT INFORMATION | | | (MAKE, MODEL, BTU'S AND SEER OF THE | | | CONDENSER). | | | | | | 4.INDICATE LOCATION OF EQUIPMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2003-11-24 |
Time |
13:37 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2003-11-24 00:00:00 | PROVISO: | | | SEE SHT PE1.0, SEC 909 WET VENTING. | | | PASSED PER PSCHMITZ |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-21 |
Time |
15:54 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-10-28 |
Time |
17:26 |
Sent To |
M |
|
| Notes |
| 2003-10-28 00:00:00 | DENIED; | | | SANITARY RISER DIAGRAM IS NOT THE SAME | | | AS FLOOR PLAN. SHOW HOW 2ND BATHROOM AND | | | WASHING MACHINE ARE TO BE PIPED AND SIZE | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-21 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|