| Plan Review Stops For Permit 03101246 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-21 |
Time |
13:07 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2004-01-21 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-21 |
Time |
12:34 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-01-15 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2004-01-15 00:00:00 | 1 SET OF NEW PLANS REVISIONS ON A2,A4 | | | 1 SET OF OLD DRAWINGSJ WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-12-11 |
Time |
12:27 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-12-11 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2003-12-11 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03101246 | | | ADD: 777 S FLAGLER DR/ SUITE # 218 | | | CONT: DEWHURST ASSOC | | | TEL: (561)241-1540 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | BUILDING PROVISO: | | | OFFICE # 13 ENTRY: TO COMPLY WITH FL BLD | | | CODE 11-4.13.6 MANEUVERING CLEARENCE AT | | | DOORS, PULL SIDE 18" FOR DOORS THAT ARE | | | NOT AUTOMATIC OR POWER-ASSISTED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-11-14 |
Time |
14:03 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2003-11-14 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2003-11-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03101246 | | | ADD: 777 S FLAGLER SUITE# 128 | | | PHILLIPS POINT WEST TOWER | | | CONT: DEWHURST ASSOC | | | TEL: (561)241-1540 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) FBC 1004.1.2 EVERY ROOM OR TENANT | | | SPACE SHALL BE PROVIDED WITH A MINIMUM | | | OF ONE MEANS OF EGRESS. EVERY ROOM OR | | | TENANT SPACE WHICH HAS AN OCCUPANT LOAD | | | OF 50 OR PERSONS OR IN WHICH THE TRAVEL | | | DISTANCE FROM THE MOST REMOTE POINT TO | | | THE EXIT ACCESS FROM THE ROOM OR TENANT | | | SPACE EXCEEDS 75 FT SHALL HAVE NOT LESS | | | THAN TWO EGRESS DOORS. | | | | | | 2) THE COMMON PATH OF TRAVEL SHALL NOT | | | EXCEED 75 FT. EXCEPTION: AS MODIFIED BY | | | SECTION 1018. 1020.1(4) MAXIMUM TRAVEL | | | DISTANCE SINGLE EXIT 75 FT. | | | | | | 3)1004.1.4 WHERE 2 OR MORE EXITS OR | | | EXIT ACCESS DOORS ARE REQUIED, AT LEAST | | | 2 OF THE EXIT OR EXIT ACCESS DOORS SHALL | | | BE PLACED A DISTANCE APART EQUAL TO NOT | | | LESS THAN 1/2 OF THE LENGTH OF THE MAX- | | | IMUM OVERALL DIAGONAL DIMENSION OF THE | | | BUILDING OR AREA TO BE SERVED. | | | EXCEPTION (2) 1/3RD DISTANCE FOR FULLY | | | SPRINKLERED BUILDINGS. | | | | | | 4) OFFICE# 13 ENTRY DOOR MUST MEET: | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 5)1204.2 SURROUNDING MATERIALS; | | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | | ROOMS SHALL BE LINED WITH NONABSORBANT | | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | | FLOOR. | | | | | | 6) 609.2.1 TYPE I & II CONSTRUCTION: | | | WOOD BACKING TO BE FIRE RESISTANT TREAT- | | | ED WOOD. | | | | | | 7)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-03 |
Time |
08:04 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-03-03 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | *** UNSAT **** | | | | | | 1)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. | | | 215.3,230.42 ETC. | | | | | | PLEASE SEE PLUMB REVIEW COMMENTS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
15:42 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-01-09 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-01-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-07 |
Time |
06:08 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-07 |
Time |
06:08 |
Sent To |
|
|
| Notes |
| 2004-01-07 00:00:00 | *********** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE THAT OLD/VOIDED SHEET | | | -S WERE RESIGNED BY ENGINEER. THESE | | | SHEETS HAVE BEEN MARKED OUT AND VOIDED, | | | PLEASE BRING IN NEW SHEETS AND INSERT | | | INTO SETS FOR STAMPING. THERE WAS NOT | | | TWO COMPLETE SETS SUBMITTED FOR STAMPING | | | FOR BLDG. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | ' | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-12 |
Time |
15:23 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-12-12 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2003-12-12 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE COMMENT FROM PREVIOUS | | | REVIEW. MUST CONTAIN A COMPLETE | | | SIGNATURE CONTAINING A MIN OF FIRST AND | | | LAST NAME AS DIRECTED BY THE FBPE'S. | | | FS 471.025 AND FAC 61G15-23.002 | | | PLEASE SEE THAT ONE SET OF PLANS ARE | | | BEING KEPT TO BE PLACED IN FILE. | | | IF COMMENTS CONTINUE THEN WE WILL HAVE | | | NO CHOICE BUT TO TURN FILE OVER TO THE | | | FBPE'S. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANYQUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-28 |
Time |
10:04 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-28 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | *********** UNSAT ***************** | | | | | | PLEASE NOTE; ELECTRICAL PLANS HAVE BEEN | | | VOIDED AND CROSSED OUT. | | | | | | 1)NOTE: PLANS MUST BE SIGNED BY THE | | | ENGINEER OF RECORD. PER FS 471.025 AND | | | FAC 61G15-23.002. INITIALED PLANS ARE | | | NO LONGER ACCEPTABLE. PLANS/COMMENTS | | | MAY BE TURNED IN TO THE FBPE'S FOR | | | REVIEW IF REQUESTED. PLEASE SEE THAT | | | WILL BE NOW KEEPING A RECORD/COPY OF | | | ONE SHEET OR SET FOR TRACKING OF | | | SIGNATURE AND OR INTERPERTAION/ REVIEW | | | BY FBPE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2003-10-28 00:00:00 | PASSED, PENDING ANY COMMENTS FROM OTHER | | | REVIEWS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-03-04 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-03-04 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | DENIED********************************** | | | PLEASE SEE COMMENTS AND NOTES BY | | | PLUMBING PLAN REVIEW. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-12-12 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-12 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-11-05 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-11-05 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | ************DENIED********************** | | | | | | 1) PLEASE SHOW EXISTING OR NEW EMERGENCY | | | LIGHTS. | | | | | | 2) ON SHEET FA0.1 NOTE #16 FIRE ALARM | | | CIRCUITS AND DEVICES SHALL BE CLASS "A" | | | STYLE "C". SHOULD AND SHALL BE FIRE | | | ALARM CIRCUITS AND DEVICES SHALL BE | | | CLASS "A" STYLE "D". | | | | | | 3) ALSO PLEASE SEE COMMENTS FROM OTHER | | | PLAN REVIEW PROFESSIONALS. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2004-02-25 00:00:00 | TO COMM BD#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-21 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-21 |
Time |
12:34 |
Sent To |
B |
|
| Notes |
| 2004-01-21 00:00:00 | TO JW DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-30 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-30 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | TO COMM BD#51 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-02 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-02 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2003-12-02 00:00:00 | TO COMM BD#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-18 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2003-10-21 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2003-10-21 00:00:00 | TO COMM BD#12 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-03 |
Time |
16:12 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-03-03 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | DENIED: | | | SEE COMMENTS BY PLUMBING PLAN REVIEW, | | | REFERENCE FS 471.025.PLANS ARE OTHER- | | | WISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-01-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-07 |
Time |
09:53 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-01-07 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2004-01-07 00:00:00 | PROVISO: | | | FAN SHUTDOWN BY DUCT SMOKE DETECTORS ARE | | | REQUIRED FOR SYSTEMS THAT SHARE A COMMON | | | RETURN AIR PLENUM.PLEASE PROVIDE DUCT | | | SMOKE DETECTORS FOR THE SUPPLY AND | | | RETURN AIR SYSTEM, PER 2001 FBC(M) | | | 606.2.2. | | | | | | FAN SHUTDOWN REQUIRED AT FINAL | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-19 |
Time |
12:32 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-12-19 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2003-12-19 00:00:00 | DENIED: | | | ONLY ONE SET OF PLANS SUBMITTED PER | | | 2001 FBC 104.2.1, TWO OR MORE COPIES | | | OF PLANS AND SPECIFICATIONS SHALL BE | | | SUBMITTED FOR REVIEW.PLANS ARE OTHER- | | | WISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-18 |
Time |
06:56 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-11-18 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2003-11-18 00:00:00 | DENIED: | | | PLEASE NOTE SIGNATURE REQUIRED BY THE | | | ENGINEER OF RECORD AS PER FS 471.025 & | | | FAC 61G15-23.002. | | | | | | MECHANICAL PLANS ARE OTHERWISE CODE | | | COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2004-02-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-28 |
Time |
08:39 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-02-28 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2004-02-28 00:00:00 | REVISION DENIED | | | REFERENCE: FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) - FS 471. | | | 025. | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 - INITIALS NOT ACCEPTABLE | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. | | | | | | 2) ONE SET OF REVISIONS WILL BE HELD FOR | | | FILE FOR FBPE REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-14 |
Time |
18:07 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-01-14 |
Time |
18:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-17 |
Time |
09:01 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-12-17 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2003-12-17 00:00:00 | DENIED | | | REFERENCE: FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | COMMENT #3 FROM PREVIOUS REVIEW HAS NOT | | | BEEN ADDRESSED. A SIGNATURE IS REQUIRED | | | ON THE ENGINEERS SEAL ALONG WITH THE | | | DATE. FAC 61G15-23.002(1) & FS 471.025 | | | SIGNATURE REQUIRED PER FBPE & BLDG. OFF- | | | ICIAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-05 |
Time |
11:24 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-11-05 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHT P2.1 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN. THE FLOOR | | | DRAIN IN ROOM #23 IS NOT SHOWN ON THE | | | RISER DIAGRAM. | | | 2) SHT P3.1 WATER HAMMER ARRESTORS SHALL | | | BE LOCATED NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. | | | PDI-WH 201 AND MANUF. INSTALL. INSTRUCT. | | | (SEE NOTE #13 PLUMBING NOTES SHT P0.1) | | | 3) A PROFESSIONAL ENGINEER SHALL SIGN | | | HIS NAME AND AFFIX HIS SEAL TO ALL PLANS | | | PER 61G15-23.002(1) & FS471.025. A CALL | | | TO THE FBPE CONFIRMED THAT A SIGNITURE | | | IS REQUIRED. | | | 4) THE SHEETS FOR PLUMBING HAVE BEEN | | | SEALED BY ONE ENGINEER AND SIGNED AND | | | DATED BY ANOTHER ENGINEER. | | | 5) ONE SET OF PLANS SHALL BE RETAINED | | | FOR OUR FILE FOR REVIEW BY THE FBPE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|