Plan Review Details - Permit 03100703
Plan Review Stops For Permit 03100703
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-05-05 Cont ID  
Sent By shill Date 2004-05-05 Time 14:36 Rev Time 2.00
Received By shill Date 2004-05-05 Time 14:36 Sent To  
Notes
2004-05-05 00:00:00PROVISO - SEPARATE PERMITS REQUIRED FOR
 SLIDING GLASS DOOR, WINDOW AND ROOF
  
 GFCI & SD IN EXISTING HOUSE FBC3401.7.
 1.2.1

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-05-04 Time 08:56 Rev Time 2.50
Received By shill Date 2004-03-23 Time 08:45 Sent To Z
Notes
2004-03-23 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED, FS713.13.
  
 2.)SEE THE PREVIOUS LIST.THE SURVEY
 SHOWS A SCREEN ENCLOSURE AND AN
 EXISTING SLAB.YOU ARE BUILDING THROUGH
 HALF OF IT.ARE YOU DEMOLISHING THE
 SCREEN ROOM, CONCRETE SLAB?SHOW ON
 THE PLAN.(ITEMS #3 AND 8)
  
 3.)SEPARATE PERMITS REQUIRED.
  
 4.)SEE PREVIOUS LIST, ITEM #6.AREA
 CALCULATIONS WERE PROVIDED, AND THE
 ADDITION IS AN OVER 25% IMPROVEMENT.
 SHOW COMPLIANCE WITH FBC3401.7.2, 2003
 AMENDMENT.
  
 5.)THE ENERGY CALC IS MISSING THE
 INFORMATION FOR ITEM #8 ON PAGE ONE,
 AND IS NOT FILLED OUT ON PAGE TWO.
 ALSO SIGN THE OWNER/AGENT LINE.FBC
 13-103.1.
  
 6.)SEE THE PREVIOUS LIST, ITEM #19.
 THE CONNECTORS SPECIFIED ARE NOT IN
 THE USP 2003 CATALOG (EXAMPLE, RTPGA836,
 RT24). CHECK ALL CONNECTORS ON THE PLAN.
  
 7.)SEE PREVIOUS LIST, ITEM #20.THE
 WINDOW/DOOR BUCK DETAIL IS FOR MASONRY,
 WALL SECTION IS FRAME. (D1)
  
 8.)SEE PREVIOUS LIST, STATEWIDE, LOCAL
 OR SITE SPECIFIC PRODUCT APPROVALS
 REQUIRED IN ADDITION TO THE TEST
 REPORTS.THE TEST REPORT SUBMITTED FOR
 THE SHUTTERS WERE ILLEGIBLE.I HAVE
 PRINTED NEW TEST REPORTS AS WELL AS
 THE FLORIDA STATEWIDE PRODUCT APPROVAL
 FOR THE SHUTTERS.PRODUCT APPROVALS
 FOR THE SLIDING GLASS DOOR, WINDOW AND
 ROOF, AND CONNECTORS ARE REQUIRED.
 WWW.FLORIDABUILDING.ORG
  
 9.)THE APPROVED ZONING SITE PLAN IS
 NOT IN THE PACKAGE.PROVIDE A SITE
 PLAN FOR ZONING APPROVAL.
  
 10.) THE PRINTED LICENSE NUMBER OF THE
 PERSON SEALING THE PLAN IS TO BE ON
 EACH SHEET, INCLUDING THE 8 1/2 X 11",
 FAC61G15-23.002.
  
 11.)ADDITIONAL FEES DUE (VALUE
 ADJUSTMENT AND RADON), SEE ATTACHED
 BZS 238893 AND 238894.PLEASE RETURN
 THE BZ WHICH WAS IN THE PACKAGE
 PREVIOUSLY SO THAT IT CAN BE VOIDED.
  
 12.)S2 INDICATES THE EXISTING
 STRUCTURE AS WOOD FRAME, BUT NOTE #4,
 D2 INDICATES CBS WALLS.ALSO IT STATES
 "ALL EXISTING"; PLANS SHOW AN
 ADDITION.
  
 13.)WHEN RESUBMITTING, PLEASE INCLUDE
 A TRANSMITTAL SHEET EXPLAINING HOW
 EACH ITEM WAS ADDRESSED.REPLACE ONLY
 SHEETS WHICH HAVE CHANGED AND SUBMIT
 THE OLD SHEETS SEPARATELY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-09 Cont ID  
Sent By btrobaug Date 2004-02-05 Time 16:58 Rev Time 1.50
Received By sthyng Date 2003-11-09 Time 16:42 Sent To  
Notes
2003-11-09 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED, FS713.13.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 3.)THE SURVEY SHOWS A SCREEN
 ENCLOSURE.YOU ARE BUILDING THROUGH
 HALF OF IT.ARE YOU DEMOLISHING THE
 ENTIRE SCREEN ROOM?SHOW ON THE PLAN.
  
 4.)THE NAME AND SIGNATURE TO THE
 PERSON RESPONSIBLE FOR THE DESIGN IS
 REQUIRED TO BE ON THE PLAN (EACH SHEET),
 FBC104.2.
  
 5.)SEPARATE PERMITS REQUIRED.
  
 6.)SHOW AREA CALCULATIONS ON THE PLAN,
 EXISTING, PROPOSED, NEW TOTAL. ADDITIONS
 OF OVER 25% OF EXISTING BUILDING AREA
 ARE REQUIRED TO COMPLY WITH FBC3401.7.2
 (SMOKE DETECTORS AND GFCIS IN EXISTING
 HOUSE), SHOW COMPLIANCE ON THE PLAN IF
 APPLICABLE.
  
 7.)ENERGY CALCS REQUIRED, FBC13-103.1.
 2.SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 8.)AN EXISTING SLAB IS IN THE AREA
 WHERE YOU ARE PROPOSING AN ADDITION.IT
 IS NOT SHOWN OR ADDRESSED ON THE PLAN.
 PROVIDE A FOUNDATION PLAN.
  
 9.)THE WALL SECTION SHOWS A PITCHED
 ROOF, THE ELEVATIONS SHOW A FLAT ROOF.
 IF IT IS PITCHED, SPECIFY THE PITCH.
 THE WALL SECTION MUST MATCH THE
 ELEVATIONS.
  
 10.) ALL DRAWINGS ARE TO BE TO SCALE
 FBC104.2.SHOW SCALE ON THE PLAN.
  
 11.)ADDITIONAL FEES (RADON), $5.12,
 SEE ATTACHED BZ233266.
  
 12.)THE ELEVATIONS DO NOT MATCH THE
 SITE/FLOOR PLANS, APPEARS THAT EAST AND
 WEST ARE LABELED INCORRECTLY.
  
 13.)MARK ROOMS BY USE (EX: BEDROOM,
 KITCHEN).
  
 14.)ON THE EXISTING FLOOR PLAN, YOU
 ARE BLOCKING ALL WINDOWS AND DOORS TO A
 ROOM WHICH APPEARS TO BE A BEDROOM.
 BEDROOMS ARE REQUIRED TO HAVE EMERGENCY
 EGRESS TO COMPLY WITH FBC1005.4.
  
 15.)IMPACT PROTECTION REQUIRED FOR
 GLAZING, FBC1606.1.7.PROVIDE A
 HURRICANE SHUTTER INSTALLATION SCHEDULE
 PER WPB POLICY.
  
 16.)THE WALL SECTION IS TO INCLUDE
 ASSEMBLY AND MATERIALS.IT REFERS TO A
 ROOF PLAN WHICH IS NOT ON THE PLAN.
 PROVIDE A ROOF FRAMING PLAN.SHOW
 ALL CONNECTIONS.
  
 17.)THE BOTTOM OF THE FOOTER IS
 REQUIRED TO BE A MINIMUM OF 12" BELOW
 GRADE, FBC1804.1.3.
  
 18.)THE CONNECTOR SPECIFIED "SIMPSON
 ETA16" IS NOT IN THE SIMPSON 2003
 CATALOG.
  
 19.)THE FRAMING DETAIL AT THE WINDOW
 SPECIFIES A HUGHES STRAP, NO LONGER IN
 BUSINESS.IT ALSO SPECIFIES "USP RTPGA
 824", NOT IN THE USP 2003 CATALOG.
 REVISE.
  
 20.)THE WINDOW/DOOR BUCK DETAIL IS FOR
 MASONRY, THE WALL SECTION IS WOOD FRAME.
 CLARIFY.
  
 21.)PROVIDE DESIGN INFORMATION ON THE
 PLAN FBC1606.1.7, 2003 AMENDMENT.
  
 22.)SMOKE DETECTORS REQUIRED FOR
 BEDROOMS, FBC905.2.2.
  
 23.)PROVIDE A FOUNDATION PLAN.
  
 24.)STATEWIDE OR LOCAL PRODUCT
 APPROVALS ARE REQUIRED.ANY PRODUCT
 APPROVALS NOT SUBMITTED AT THE TIME OF
 PERMIT ISSUANCE WILL NOT INCLUDE THOSE
 ITEMS AS PART OF THIS PERMIT AND WILL
 REQUIRE A SEPARATE APPLICATION WITH
 ADDITIONAL FEES.THIS DOES NOT APPLY
 TO STRUCTURAL COMPONENTS, WHICH ARE
 REQUIRED FOR THIS PERMIT.SEE THE
 DCA WEBSITE FOR MORE INFORMATION:
  
 WWW.DCA.STATE.FL.US/FHCD/FBC/COMMITTEES/
 PRODUCT_APPROVAL/1_PRODUCT_APPROVAL.HTM
  
 FAC9B-72.050, EFFECTIVE OCTOBER 1, 2003

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-12 Cont ID  
Sent By btrobaug Date 2004-03-12 Time 17:27 Rev Time 0.50
Received By btrobaug Date 2004-03-12 Time 17:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-05 Cont ID  
Sent By csiegber Date 2004-03-08 Time 10:22 Rev Time 0.50
Received By btrobaug Date 2004-02-05 Time 16:08 Sent To B
Notes
2004-02-05 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 PLEASE NOTE ON PLAN.
  
 2} A RECEPTACLE IS REQUIRED ON THE WALL
 BETWEEN THE DOORS IN THE NORTH EAST
 CORNER IN THE BEDROOM PER 210.52(A)(2).
  
 3} SMOKE DETECTORS ARE REQUIRED PER
 8-1.4.1.6.2 NFPA-72,AND WIRED PER
 905.2.5 FBC.
  
 4} CHANGES TO THE PLAN MUST BE DONE BY
 THE DESIGNER OF RECORD (ARCHITECT).
  
 5} PLEASE PROVIDE A CALCULATION
 INCLUDI-NG ALL ADDED LOADS IMPOSED,ALL
 EXISTING LOADS AND THE EXISTING OR
 PROPOSED
 SERVICE SPECIFICATIONS PER 215.15.ALSO
 SEE 220.3(A)(4) REGARDING RECESSED
 LUMINAIRS.
  
 6} PLEASE NOTE, ALL PLANS DRAWN
 BY AN ARCHITECT/ENGINEER CONTAIN-
 -ING A TITLE BLOCK: MUST BE SIGNED,
 DATED AND SEALED BY THAT ARCH/ENG.
 PER FS 481.221 471.025
 FAC 61G15-23.002, 61G1-16.004
  
 7} PLEASE NOTE THAT A SEPARATE
 ELECTRICAL PERMIT IS REQUIRED FOR THIS
 WORK.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-05-04 Cont ID  
Sent By csiegber Date 2004-05-04 Time 08:56 Rev Time 0.00
Received By csiegber Date 2004-05-04 Time 08:56 Sent To B
Notes
2004-05-04 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-04-19 Cont ID  
Sent By mmclean Date 2004-05-03 Time 12:31 Rev Time 0.00
Received By csiegber Date 2004-04-19 Time 11:47 Sent To Z
Notes
2004-04-19 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-03-08 Cont ID  
Sent By csiegber Date 2004-03-08 Time 10:22 Rev Time 0.00
Received By csiegber Date 2004-03-08 Time 10:22 Sent To E
Notes
2004-03-08 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-02-05 Cont ID  
Sent By shill Date 2004-02-05 Time 13:06 Rev Time 0.00
Received By shill Date 2004-02-05 Time 13:06 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-01-29 Cont ID  
Sent By csiegber Date 2004-01-29 Time 10:55 Rev Time 0.00
Received By csiegber Date 2004-01-29 Time 10:55 Sent To B
Notes
2004-01-29 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-16 Cont ID  
Sent By csiegber Date 2003-10-16 Time 16:47 Rev Time 0.00
Received By csiegber Date 2003-10-16 Time 16:47 Sent To B
Notes
2003-10-16 00:00:00TO RES BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-16 Cont ID  
Sent By mmclean Date 2003-10-16 Time 16:03 Rev Time 0.00
Received By csiegber Date 2003-10-16 Time 11:18 Sent To Z
Notes
2003-10-16 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-10-14 Time 14:10 Rev Time 0.00
Received By csiegber Date 2003-10-14 Time 14:10 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2004-05-03 Cont ID  
Sent By mmclean Date 2004-05-03 Time 12:31 Rev Time 0.00
Received By mmclean Date 2004-05-03 Time 12:31 Sent To I
Notes
2004-05-03 00:00:00APPROVED REV MM

Review Stop Z ZONING
Rev No 3 Status F Date 2004-03-25 Cont ID  
Sent By csiegber Date 2004-04-19 Time 11:47 Rev Time 0.00
Received By mmclean Date 2004-03-25 Time 11:49 Sent To  
Notes
2004-03-25 00:00:00DENIED, SITE PLAN MISSING CALLED OWNER
 FILE H MM

Review Stop Z ZONING
Rev No 2 Status P Date 2003-10-16 Cont ID  
Sent By shill Date 2004-03-23 Time 11:38 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-10-15 Cont ID  
Sent By csiegber Date 2003-10-16 Time 11:18 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-10-15 00:00:0010/15/03 DENIED, NEED TO PROVIDE 2 COPY
 OF SURVEY SHOWING THE ADDITION CALLED
 OWNER FILE H MM