| Plan Review Stops For Permit 03100659 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-02 |
Time |
14:33 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-02 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-02 |
Time |
10:34 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-05-25 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2004-05-25 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)ONLY ONE SEALED SET SUBMITTED. | | | SUBMIT A SECOND SIGNED AND SEALED SET | | | OF PLANS FOR THE PERMIT TO BE ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-14 |
Time |
10:20 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-05-14 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE THE SOILS ENGINEER'S | | | RECOMMENDATIONS IN REGARDS TO FOOTINGS. | | | ALSO THE SOILS REPORT IS FOR SINGLE | | | STORY ADDITIONS; REVISE THE SOILS | | | REPORT TO CORRECTLY REFLECT THE SCOPE | | | OF WORK.REVISE WALL SECTIONS/FOUND. | | | PLAN AS NECESSARY. | | | | | | 2.)THE NOTICE OF COMMENCEMENT IS FOR | | | A GARAGE ADDITION.REVISE TO MORE | | | ACCURATELY REFLECT THE SCOPE OF WORK. | | | | | | 3.)PROVIDE A MORE COMPLETE TRAY | | | CEILING DETAIL.THE FRAMING APPEARS | | | SUSPENDED; WHERE IS THE OUTSIDE WALL? | | | IT IS NOT CLEAR HOW THE FIRESTOPS SHOWN | | | WILL PERFORM AS FIRESTOPS.SEE ATTACHED | | | AS AN EXAMPLE OF ONE WAY TO SHOW | | | COMPLIANCE FOR FRAMED WALLS. | | | | | | 4.)HANDRAIL REQUIRED AT STAIRS FBC | | | 1007.5, PROVIDE DETAILS; SHOW COMPLIANCE | | | WITH FBC CHAPTER 10 AND FBC 1608. | | | | | | 5.)THE 7/8 STUCCO (WALL SECTION) IS | | | TO BE A 3 COAT VERTICAL, NOT A 2 COAT | | | HORIZONTAL, APPLICATION FBC2504.2.2, | | | ASTM C926.THIS APPLIES ONLY TO STUCCO | | | IN A VERTICAL APPLICATION OVER WIRE | | | LATH. | | | | | | 6.)SEE PREVIOUS LISTS, FLORIDA STATE, | | | LOCAL OR SITE SPECIFIC PRODUCT APPROVALS | | | REQUIRED IN ADDITION TO THE TEST REPORTS | | | PROVIDED.WWW.FLORIDABUILDING.ORG | | | (PRODUCT APPROVAL, SEARCH PRODUCT | | | APPROVALS). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-24 |
Time |
08:20 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-02-24 |
Time |
08:20 |
Sent To |
M |
|
| Notes |
| 2004-02-24 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LIST, ITEM #1, PROVIDE | | | A SURVEY FOR THIS JOB. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 4.)THE ENGINEER IS TO DATE THE SEAL, | | | FAC61G-23.002. | | | | | | 5.)ADDITIONAL FEES DUE (VALUE | | | INCREASE), $660.11.BZ235302 | | | | | | 6.)SEE PREVIOUS LIST, ITEM 6, STILL | | | REFERS TO SBC, BUT NOW THE SHEET IS A15. | | | | | | 7.)SEE PREVIOUS LIST, ITEM #9.DESIGN | | | IS FOR A SIMPLE DIAPHRAGM WHICH SHOULD | | | BE SYMMETRICAL.THIS STRUCTURE IS NOT | | | SYMMETRICAL.ADDRESS. | | | | | | 8.)PROVIDE A DETAIL FOR THE TRAY | | | CEILING INCLUDING FIREBLOCKING. | | | | | | 9.)SEE PREVIOUS LIST, ITEM #13, | | | PROVIDE A GUARDRAIL DETAIL TO COMPLY | | | WITH FBC1608.2.2 AND FBC1015. | | | | | | 10.)STAIR RAIL IS TO COMPLY WITH | | | FBC1608 AND 1007. | | | | | | 11.)SEE PREVIOUS LIST, PROVIDE A SOILS | | | INVESTIGATION REPORT. | | | | | | 12.)SEE PREVIOUS LIST, ITEM #18, IN | | | REGARDS TO WALL SECTIONS TO COMPLY WITH | | | FBC1804.1.3 AND FBC1804.1.7 CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | | | | 13.)SEE PREVIOUS LIST, ITEM #21, | | | PROVIDE STATEWIDE PRODUCT APPROVALS IN | | | ADDITION TO THE TEST REPORTS PROVIDED. | | | | | | 14.)SEE PREVIOUS LIST, ITEM #27, | | | STUCCO IS REQUIRED TO BE 7/8"VERTICAL | | | APPLICATION, FBC2504.2.2, ASTM C926. | | | THIS APPEARS IN SEVERAL PLACES; CHECK | | | ALL DETAILS. | | | | | | 15.)PROVIDE MULLION PRODUCT APPROVALS, | | | AS WELL AS ANY OTHER PRODUCT APPROVALS | | | REQUIRED.ANY PRODUCT APPROVALS | | | REQUIRED BUT NOT SUBMITTED WILL REQUIRE | | | SEPARATE PERMITS. | | | | | | 16.)THERE ARE TWO 2-STORY WALL | | | SECTIONS, ONE BLOCK AND ONE FRAME ON | | | THE 2ND FLOOR.IT APPEARS THAT THE | | | 2ND FLOOR IS TO BE FRAME (FLOOR PLAN), | | | BUT THE HURRICANE SHUTTER SCHEDULE | | | INDICATES BLOCK FASTENING FOR ALL | | | OPENINGS.PLEASE CLARIFY. | | | | | | 17.)STORM SHUTTER PRODUCT APPROVAL IS | | | ILLEGIBLE. | | | | | | 18.)WHEN RESUBMITTING, REPLACE SHEETS | | | WHICH HAVE CHANGED AND SUBMIT OLD | | | SHEETS SEPARATELY.INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED TO EXPEDITE PLAN | | | REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-12 |
Time |
11:05 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-11-09 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2003-11-09 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)PROVIDE A SURVEY FOR THIS JOB. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 FOR MORE | | | INFORMATION. | | | | | | 4.)THIS IS AN ADDITION OF GREATER | | | THAN 25% AND MUST COMPLY WITH 3401.7.2. | | | FBC, 2003 AMENDMENT (GFCI AND SMOKE | | | DETECTORS IN EXISTING HOUSE). | | | | | | 5.)SHEET A1, SITE PLAN, PROVIDE | | | DIMENSIONS. | | | | | | 6.)SHEET C1, SITE PLAN NOTE #14, | | | REFERS TO SBC103.THE GOVERNING CODE | | | IS FBC; SECTION 103 REFERS TO POWERS & | | | DUTIES OF THE BUILDING OFFICIAL. | | | | | | 7.)SHEET C1, TRUSS NOTES #9, ROOF | | | SHEATHING SCHEDULE MUST COMPLY WITH | | | CITY OF WEST PALM BEACH AMENDMENTS TO | | | THE FBC, TABLE 2306.1. | | | | | | 8.)SHEET C1, WINDOW AND DOOR NOTES, | | | THE MIN DESIGN PRESSURE IS +-34; | | | CONFLICTS WITH DESIGN PRESSURES ON | | | DOOR AND WINDOW SCHEDULES. | | | | | | 9.)SHEET A2, WIND DESIGN INFORMATION | | | INDICATES THAT THE DESIGN OF THE | | | BUILDING IS BASED ON THE SIMPLIFIED | | | PROVISIONS OF FBC1606.2.THIS IS FOR | | | A SIMPLE DIAPHRAGM BUILDING.THE | | | BREEZEWAY IS NOT ALLOWED PER ZONING; | | | THE BUILDING NO LONGER QUALIFIES AS A | | | SIMPLE DIAPHRAGM. | | | | | | 10.) FIRESTOP REQUIRED FOR STAIRS, | | | FBC2305.1.4. | | | | | | 11.) WIND DESIGN INFORMATION IS | | | INCOMPLETE, SEE FBC1606.1.7 2003 | | | AMENDMENT, SHEET A2. | | | | | | 12.) PROVIDE A STRUCTURAL DETAIL FOR | | | THE STAIRS. | | | | | | 13.) PROVIDE A GUARDRAIL DETAIL, COMPLY | | | WITH FBC1015, 1608. | | | | | | 14.) STAIR RAIL TO COMPLY WITH FBC1608. | | | | | | 15.) DESIGN GRAVITY LOADS, A3 & A7(UNDER | | | THE WALL SCHEDULE), REQUIRES A BOTTOM | | | CHORD LIVE LOAD OF 10 FOR ATTICS WITHOUT | | | STORAGE, 30 FOR ATTICS WITH STORAGE, | | | FBC TABLE 1604.1. | | | | | | 16.) WINDOW G, 2ND FLOOR OF DETACHED | | | BUILDING, A3, TO COMPLY WITH FBC2405.1 | | | (SAFETY GLASS). | | | | | | 17.) PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 18.) SHEETS A4, A5, A6, WALL SECTION | | | REQUIRES THE FINISHED FLOOR TO BE MIN | | | 4" ABOVE FINISHED GRADE, CITY OF WEST | | | PALM BEACH AMEND. TO THE FBC1804.1.7. | | | 12" MIN BELOW GRADE REQUIRED FOR THE | | | FOOTER, FBC1804.1.3. | | | | | | 19.)SHEET A10, HEAD AND SILL DETAILS | | | FOR WINDOWS, NOTE THAT HURRICANE | | | SHUTTERS MUST BE INSTALLED HORIZONTALLY | | | FOR THOSE OPENINGS BASED ON THIS DETAIL. | | | | | | 20.)PROVIDE A HURRICANE SHUTTER | | | INSTALLATION SCHEDULE, SEE ATTACHED, | | | PER CITY OF WEST PALM BEACH POLICY. | | | | | | 21.) STATEWIDE OR LOCAL PRODUCT | | | APPROVAL IS REQUIRED FOR ALL PRODUCTS, | | | INCLUDING STRUCTURAL, FAC 9B-72.050, | | | EFFECTIVE OCTOBER 1, 2003.FOR MORE | | | INFORMATION, SEE THE DCA WEBSITE AT | | | WWW.DCA.STATE.FL.US/FHCD/FBC/COMMITTEES/ | | | PRODUCT_APPROVAL/1_PRODUCT_APPROVAL.HTM | | | | | | 22.) THE PRODUCT APPROVAL FOR THE PGT | | | SINGLE HUNG WINDOW IS ILLEGIBLE.THE | | | CASEMENT PRODUCT APPROVAL IS FOR A | | | DOUBLE (OPERABLE MULLED TO FIXED),SINGLE | | | WINDOW IS NOT COVERED BY THIS PRODUCT | | | APPROVAL.THE 6'X6' PICTURE WINDOW | | | EXCEEDS THE MAXIMUM RECTANGULAR WINDOW | | | SIZE COVERED BY THE PRODUCT APPROVAL | | | SUBMITTED (OK FOR ARCHED WINDOW). | | | | | | 23.)THE FOLLOWING PRODUCT APPROVALS | | | ARE NEEDED: | | | STATEWIDE PRODUCT APPROVAL FOR ALL | | | DADE COUNTY NOAS SUBMITTED AND | | | CONDITIONALLY APPROVED (SPANISH S, | | | 16X8 GAR DOOR, STORM PANELS, PGT | | | OUTSWING FR DOOR,STANLEY OUTSWING | | | GLAZED DOOR, ALUM FG WINDOW) | | | INSWING FRENCH DOOR | | | SINGLE HUNG WINDOW | | | MULLION | | | OUTSWING METAL DOOR | | | 6'X6' FIXED GLASS WINDOW | | | CASEMENT WINDOW | | | | | | 24.)PROVIDE A DRAFTSTOP DETAIL AND | | | SCHEDULE, BOTH BUILDINGS, FBC705.3. | | | | | | 25.)WALL SECTION, SHEETS A4, A5, A6, | | | FIRESTOP REQUIRED FBC705.3. | | | | | | 26.) WALL SCHEDULES, A3, A7, A8, | | | SPECIFIES R30 INSULATION FOR A 4"OR6" | | | WALL.IS THIS CORRECT?CONFLICTS WITH | | | WALL SECTION. | | | | | | 27.) WALL SECTION, A6, STUCCO IS | | | REQUIRED TO BE 7/8" HORIZONTAL | | | APPLICATION OVER WIRE LATH, FBC2504.2.2, | | | ASTM C926. | | | | | | 28.) ADDITIONAL FEES DUE (VALUE | | | ADJUSTMENT, RADON), $125.18, SEE | | | ATTACHED BZ233272. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-02 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2004-06-02 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
| 2004-06-02 00:00:00 | LETTER FAXED IN FROM OWNER. | | | NO ELECTRICAL REVIEW TO BE DONE ON THESE | | | PLANS. WILL SUBMIT SEPARATE PLANS, | | | PERMIT APPLICATION AND FEES AT A LATER | | | DATE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
13:05 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-05-05 |
Time |
19:29 |
Sent To |
P |
|
| Notes |
| 2004-05-05 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002, | | | FS 471.023. PLEASE SEE MISSING REQ'D | | | LICENSE #'S ON TITLE BLOCKS. THIS IS | | | REQ'D FOR ALL TRADES WEATHER OR NOT | | | COMMENT IS MADE FROM OTHER REVIEWERS | | | THIS HAS BEEN REQUESTED ON PREVIOUS | | | REVIEW. | | | THE STATE DOES NOT HAVE ANY LISTING OF | | | A REQ'D LICENSE / CA#?? | | | PLEASE VERIFY LICENSING W/ FBPE'S, DBPR. | | | | | | | | | 2)NOTE: PLEASE SEE AN "ALUMINUM" EQUIP- | | | -MENT GROUNDING CONDUCTOR HAS NOW BEEN | | | ADDED. PLEASE SEE ALUM GRNDING CONDUCTOR | | | -S ARE NOT PERMITTED. | | | | | | 3)NOTE: PLEASE CORRELATE RISER DIAGRAM, | | | PANEL SCHEDULE AND LOAD CALCULATIONS. | | | RISER SHOWS 200A SERVICE ALONG WITH | | | PANEL SCHEDULE, YET PANEL SCHEDULE | | | ALSO INDICATES A 150 MCB???? | | | | | | 4)NOTE: PLEASE PROVIDE LOAD CALCULATIONS | | | TO MEET NEC 220. | | | | | | 5)NOTE: PLEASE CORRELATE LOAD CALCULAT- | | | -IONS WITH PANEL SCHEDULE. THERE ARE | | | MANY ITEMS THAT DO NOT CORRELATE. | | | PLEASE SEE ONE SET REDLINED. | | | | | | 6)NOTE: PLEASE SEE 220.18 FOR MIN 5KW | | | FOR DRYER. | | | | | | 7)NOTE: PLEASE SEE OCP SHOWN FOR AHU'S | | | 7.5KW W/ 60A BRKRS. PLEASE VERIFY OCP. | | | TOO HIGH. | | | | | | 8)NOTE: PLEASE SEE 110.26, DISC FOR A/C | | | UNIT DOES NOT MEET ABOVE. | | | | | | 9)NOTE: PLEASE SEE WALKWAY/HALL BETWEEN | | | NEW AND ADDITION. MEANS OF EGRESS | | | CONTROL FOR LTS. 210.70 FROM MAIN HOUSE. | | | | | | 10)NOTE:PLEASE SEE NFPA-72 8-1.4.2, NO | | | SD'S TO BE W/IN 3' FROM BATH DOOR. | | | | | | 11)NOTE: PLEASE SEE PREVIOUS COMMENT | | | ABOUT CHAPTER 34 FBC. 3401.7.2.6 | | | SHOW EXSITING LAYOUT OF EXIST HOUSE, | | | ITEMS MUST BE SHOWN FOR BRING UP TO | | | 2002 NEC. | | | BLDG IS OVER 50%. | | | | | | 12)NOTE: PLEASE SHOW CONDUCTORS AND | | | CONDUIT SIZE FROM MAIN DISC TO PANEL. | | | 215.5, 310.15B6 | | | | | | 13)NOTE: PLEASE SUBMIT AIC RATING FOR | | | NEW MAIN. 110.9,215.5 | | | | | | PLEASE SEE COPY OF FS 553.80(2)(B) | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-02-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
08:17 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-02-10 |
Time |
07:22 |
Sent To |
P |
|
| Notes |
| 2004-02-10 00:00:00 | ************** UNSAT ***************** | | | | | | **** PLEASE SEE ZONING NOTES, AS THEY | | | WILL HAVE A DIRECT AFFECT ON ELETCRICAL, | | | MECHANICAL, AND PLUMB PLANS*********** | | | | | | *PLEASE SEE ELECTRICAL NOTE FROM FRIST | | | REVIEW. PLEASE SEE MOST NOTES STILL | | | NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE 230.2,230.70,230.72, | | | TWO SERVICES ARE NOT PERMITTED AND MAINS | | | MUST BE GROUPED PER 230.72 | | | | | | 2)NOTE: PLEASE SHOW LOCATIONS OF ALL | | | ELECTRICAL SERVICE EQUIPMENT ON PLANS. | | | | | | 3)NOTE: PLANS SHOW TWO SEPARATE RISERS, | | | HOWEVER THESE ITEMS ARE NOT SHOWN ON | | | PLANS? IF INDEED THIS IS ONLY ONE SERV- | | | -ICE, PLEASE CORRELATE LOAD CALCS. | | | PLEASE SEE THAT A/C SYSTEMS ARE SHOWN ON | | | EACH SERVICE AND DO NOT COME FROM ONE. | | | SMALL APPL, DRYERS, WASHER ETC. | | | PANEL SCHEDULES WERE NOT SUBMITTED AS | | | REQUESTED ON FIRST REVIEW, UNABLE TO | | | VERIFY. | | | | | | 4)NOTE: PLEASE SEE 310.15B6/310.16 FOR | | | SIZING OF SERVICE ENTRANCE CONDUCTORS | | | AND FEEDERS. PLANS SHOW 1/0'S, THESE | | | ARE NOT OF SUFF SIZE FOR 200A SERVICE. | | | RISER IS MISSING CONDUCTORS FROM MAIN(S) | | | TO PANELS. | | | PLEASE ALSO SEE MISSING EQUIPMENT GROUND | | | -ING CONDUCTOR FROM MAIN TO PANEL. PER | | | 250.110,250.24, SIZE PER 250.122 | | | | | | 5)NOTE: PLEASE SEE MISSING COLD WATER | | | PIPE TO BE PART OF THE GROUNDING ELECT- | | | -RODE SYSTEM. 250.50 | | | | | | 6)NOTE: PLEASE SEE RISER, INDICATES | | | MAIN, YET 200A PANEL IS ALSO SHOWN AS | | | MCB? PLEASE NOTE, THIS IS PERMITTED, | | | HOWEVER NOT REQUIRED. IF PLANS SHOW, | | | THEN THEY WILL BE REQ'D TO BE INSTALLED, | | | UNLESS PLANS ARE REVISED. | | | | | | 7)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | MISSING SOME. | | | SD'S ARE ALSO REQ'D TO BE A MIN OF 3' | | | FROM BATHROOM DOORS AND KITCHENS. SD'S | | | ARE ALSO NOT PEMITTED IN KITCHENS. | | | | | | 8)NOTE: PLEASE SEE COMMENTS FROM FIST | | | REVIEW, PANEL SCHEDULE(S)OCP,AWG, ETC | | | ALONG WITH ALL MIN REQ'D DEDICATED | | | CIRCUITS MUST BE SUBMITTED. 210.52D, | | | 210.11C3,210.11, 210.12ETC. | | | | | | 9)NOTE: PLEASE SHOW/INDICATE ALL ROOM | | | DESIGNATIONS ON ELECTRICAL PLANS. 1ST | | | REVIEW. | | | | | | 10)NOTE: PLEASE SEE FAC 61G15-23.002, | | | FS 471.023. PLEASE INCLUDE ALL INFORMAT- | | | -ION AS REQUIRED FOR TITLE BLOCK. | | | PLEASE INCLUDE ALL LICENSE #'S. | | | PLEASE SEE ADDRESS DOES NOT CORRELATE | | | WITH FILE OF ACTUAL ADDRESS. PLANS SHOW | | | 257 AND PROPERTY IS LISTED AS 253. | | | | | | 11)NOTE: PLEASE SEE COPY OF FS 553.80(2) | | | (B) WITH RESPECT TO DESIGN PROFESSIONAL. | | | | | | 12)NOTE: UNABLE TO DUE A COMPLETE REVIEW | | | FOR CODE COMPLIANCE TO 2002NEC DUE TO | | | MISSING REQUIRED INFORMATION. | | | | | | 13)NOTE: PLEASE SEE FBC CHAPTER 34 FOR | | | ADDITIONS TO EXSITNG BLDGS. | | | PLEASE SEE THAT MORE THAN 25% IS BEING | | | ADDED AND WILL REQUIRE EXISTING ELECTRIC | | | -AL TO BE UPGRADED TO MEET 2002 NEC | | | PLEASE PROVIDE PLANS/ LAYOUT FOR EXSIT- | | | -ING ELECTRICAL AND LOCATION OF ALL | | | DEVICES. PLEASE ALSO SEE THAT SD'S WILL | | | BE REQUIREDFOR EXISTING, DEDICATED | | | CIRCUITS, GFI'S, ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-05 |
Time |
10:49 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-10-27 |
Time |
10:11 |
Sent To |
P |
|
| Notes |
| 2003-10-27 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE ZONING COMMENTS THAT | | | WILL AFFECT ELECTRICAL PLANS. | | | | | | 2)NOTE: PLEASE SEE THAT SEPARATE SERVICE | | | IS NOT PERMITTED. 230.2, 230.72, 230.70 | | | | | | 3)NOTE: PLEASE SEE 210.52C1-5 | | | | | | 4)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | | ON ELECTRICAL PLANS. | | | | | | 5)NOTE: PLEASE CLARIFY IF RISER DIAGRAM | | | SHOWN FOR MAIN HOUSE IS NEW OR EXISTING? | | | | | | 6)NOTE: PLEASE PROVIDE PANEL SCHEDULE(S) | | | WITH AWG/ OCP ETC. | | | PLEASE LIST ALL THE MIN REQ'D CIRCUITS | | | PLEASE LIST THE ARC FAULT PROETCTED | | | CIRCUITS PER 210.12. | | | 2002 NEC | | | | | | PLEASE SEE THAT A FULL REVIEW FOR | | | ELECTRICAL CODE COMPLIANCE CAN NOT BE | | | DONE AT THIS TIME DUE TO MAJOR ELECTRIC- | | | -AL CHANGES. | | | | | | PLEASE SUBMIT FOR REVIEW .IF THERE ARE | | | ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
17:11 |
Sent To |
P |
|
| Notes |
| 2004-10-20 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-27 |
Time |
13:05 |
Sent To |
E |
|
| Notes |
| 2004-05-27 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-24 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-24 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-05 |
Time |
08:16 |
Sent To |
E |
|
| Notes |
| 2004-05-05 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-04 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-30 |
Time |
14:50 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-05 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-05 |
Time |
10:49 |
Sent To |
E |
|
| Notes |
| 2004-02-05 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-04 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-02 |
Time |
10:48 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-27 |
Time |
10:25 |
Sent To |
E |
|
| Notes |
| 2004-01-27 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
12:39 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-22 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-14 |
Time |
09:00 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-07 |
Time |
10:37 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-03-02 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | NO CHANGES FROM 2-12-04 SUBMITTAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-24 |
Time |
10:28 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-02-12 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
| 2004-02-12 00:00:00 | PLAN WAS APPROVED NOV 5, 2003 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-02-10 |
Time |
14:56 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-11-05 |
Time |
11:38 |
Sent To |
B |
|
| Notes |
| 2003-11-05 00:00:00 | PLEASE NOTE RETURN AIR REQUIREMENTS AS | | | REVISION TO THE 2001 FBC(M) 601.4 | | | EFFECTIVE JUNE 30,2003. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-02 |
Time |
15:44 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-11-02 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2004-11-02 00:00:00 | REVISION OK - ADD SHOWER - CHANGE TUB | | | TO JACUZZI |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-02-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
17:12 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-02-10 |
Time |
14:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-10 |
Time |
12:41 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-28 |
Time |
13:35 |
Sent To |
M |
|
| Notes |
| 2003-10-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT RE- | | | FLECT THE FLOOR PLAN, NOR DOES IT MEET | | | CODE REQUIREMENTS. THE LAUNDRY ROOM | | | HAS A W/M AND A LAUNDRY SINK. NO SINK | | | IS SHOWN ON RISER. 104.2.1 - THE WASH | | | MACHINE REQUIRES A STANDPIPE. SECTION | | | 1002.1 & 802.4. - A CLEANOUT IS REQUIRED | | | 4' ABOVE THE FLOOR AT THE WASH MACHINE | | | SECTION 708.10. - THE RISER SHOWS SHOW- | | | ERS AND THE FLOOR PLAN SHOWS TUBS. SECT- | | | ION 104.2. SEE RED LINE CORRECTIONS TO | | | BE MADE TO RISER AND RESUBMIT FOR REVIEW | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-04 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-04 |
Time |
15:29 |
Sent To |
I |
|
| Notes |
| 2004-05-04 00:00:00 | NO KITCHEN ALLOWED IN PHASE "B" MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-30 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-04 |
Time |
16:35 |
Sent To |
I |
|
| Notes |
| 2004-02-04 00:00:00 | DENIED, CANNOT HAVE PHASE B CONNECT TO | | | HOUSE WITH KITCHEN.CAN REMOVE KITCHEN. | | | MAX FOR 1 UNIT IS 800SQ FT AND 200SQ FT | | | FOR GARAGE.CALLED MIKE GARRISON MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-02 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-10-15 00:00:00 | 10/14/03 DENIED CANNOT HAVE A BREEZEWAY | | | NEED TO BE 5FT SEPERATION/GARAGE APT | | | CAN ONLY BE 750SQ FT & CAN ONLY BE BUILT | | | BEHIND THE MAIN STRUCTURE.SEE SEC 94- | | | 74 & SEC 94-146 OF ZONING CODE CALLED | | | OWNER FILE Z MM |
|
|