| Plan Review Stops For Permit 03100653 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
53 |
Status |
P |
Date |
2005-08-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-22 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-22 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2005-08-22 00:00:00 | SATISFIED PROVISO - SUBMITTED TITLE | | | BLOCK FOR ENGINEER'S SHEETS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
52 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-27 |
Time |
16:04 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-27 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2005-07-27 00:00:00 | QUICK TIE SUBMITTAL | | | LOCAL PRODUCT APPROVAL ISSUED PREVIOUSLY | | | REVOKED AS THIS PRODUCT NOW HAS STATE | | | APPROVAL, FL3557 | | | | | | | | | ****PROVISO**** | | | | | | SAMANTA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)MR. R.F.OLECK IS TO PROVIDE A TITLE | | | BLOCK FOR THE PLANS WE HAVE ON FILE. | | | THE TITLE BLOCK IS TO BE IN COMPLIANCE | | | WITH FAC61G15-23.002 FOR ENGINEERING | | | SERVICES GROUP, INC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
51 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-27 |
Time |
11:54 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-27 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2005-07-27 00:00:00 | STAIR BASE PLATE CALCS PREPARED BY MARK | | | ASKEW, PE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
50 |
Status |
F |
Date |
2005-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-24 |
Time |
14:21 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-07-24 |
Time |
14:21 |
Sent To |
PC |
|
| Notes |
| 2005-07-24 00:00:00 | ****CORRECTIONS**** | | | QUICK TIE ENGINEERING, REVISION | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)PLEASE CLARIFY WHO ENGINEER OF | | | RECORD IS FOR THIS PROJECT (IN THE FORM | | | OF A SIGNED AND SEALED LETTER).THERE | | | WAS NO TITLE BLOCK FOR ROBERT OLECK, PE | | | ON THE SHEETS THAT HE SEALED.PLEASE | | | PROVIDE A TITLE BLOCK FOR OUR | | | ENGINEERING SHEETS, PREFERABLY IN THE | | | FORM OF A STICKER.FAC61G15-23.002. | | | | | | ROBERT OLECK, PE SEALED THE PLAN. | | | ENGINEERING SERVICES GROUP, INC. IS | | | REVIEWING SUBMITTALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
49 |
Status |
P |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-22 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-07-22 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2005-07-22 00:00:00 | TRUSS SUBMITTALS | | | MAINTENANCE | | | BUS SHELTER | | | MAIL KIOSK | | | TYPE 1A 2ND FLOOR | | | TYPE 1C BLDG 1 ROOF | | | TYPE 1B 3RD FLOOR & ROOF | | | CLUBHOUSE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
48 |
Status |
F |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-30 |
Time |
11:17 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-06-30 |
Time |
11:17 |
Sent To |
PC |
|
| Notes |
| 2005-06-30 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)ALL SUBMITTALS TO BE REVIEWED BY | | | DOR AND/OR EOR AS APPLICABLE. | | | | | | 2.)ONLY ONE COPY SUBMITTED.PLEASE | | | PROVIDE THREE COPIES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
47 |
Status |
F |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-03 |
Time |
09:43 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-06-03 |
Time |
09:43 |
Sent To |
PC |
|
| Notes |
| 2005-06-03 00:00:00 | ****CORRECTIONS**** | | | STAIR SHOPS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE HANDRAIL EXTENSION AT THE TOP | | | OF THE STAIRS IS TO COMPLY WITH FBC11 | | | FIGURE 19, FBC11-4.94(6). | | | | | | 2.)DELEGATED ENGINEERING AND | | | SUBMITTALS TO BE REVIEWED BY ARCHITECT | | | OR ENGINEER OF RECORD. | | | | | | 3.)THE GUARDRAIL IS TO COMPLY WITH | | | FBC1015.2. | | | | | | 4.)A TITLE BLOCK IS REQUIRED FOR THE | | | ENGINEER WHO SEALED THE PLAN, | | | FAC61G15-23.002.A SEAL ON EACH SHEET | | | IS REQUIRED, NOT ONLY THE COVER SHEET. | | | | | | 5.)WHAT IS UNDER THE STAIRS? | | | FBC1006.1.4. | | | | | | 6.)PLEASE RESUBMIT PREVIOUSLY DENIED | | | RAILING SHOPS AND CALCS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
46 |
Status |
F |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-04-12 |
Time |
08:15 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2005-04-12 |
Time |
08:15 |
Sent To |
PC |
|
| Notes |
| 2005-04-12 00:00:00 | ****CORRECTIONS**** | | | HURRICANE MISSILE IMPACT PROTECTION PLAN | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE NOTE THAT ALTHOUGH THE SCOPE | | | IS CONSIDERABLY SMALLER THAN THE | | | PREVIOUS PLAN SUBMITTED, ALL PERTIN ENT | | | INFORMATION/DOCUMENTATION IS STILL | | | REQUIRED. | | | | | | 2.)PROVIDE A FLOOR PLAN SHOWING WHERE | | | THE SHUTTERS WILL BE STORED.INDICATE | | | WHETHER THEY WILL BE STORED VERTICALLY | | | OR HORIZONTALLY.IF THEY ARE STORED | | | VERTICALLY, PROVIDE A RACK DETAIL | | | SHOWING HOW THEY WILL BE SECURED. | | | | | | 3.)THE PARAGRAPH ON THE PLAN MARKED | | | "STORAGE" INDICATES THAT YOU ARE STORING | | | SHUTTERS FOR THE DOORS.ARE YOU GOING | | | TO SHUTTER THE WINDOWS AS WELL?PLEASE | | | ALSO STATE WHERE THE SHUTTERS WILL BE | | | STORED. | | | | | | 4.)NOTE THAT THE CITY PREFERS THAT THE | | | SHUTTERS BE STORED AT THE LOCATION WHERE | | | THEY ARE GOING TO BE INSTALLED (AT THE | | | CLUBHOUSE). | | | | | | 5.)THE PARAGRAPH "TRANSPORTATION" | | | INDICATES THAT THE SHUTTES WILL BE | | | STORED AT THE MAINTENANCE BUILDING.IF | | | IT IS IMPOSSIBLE TO STORE THE SHUTTERS | | | AT THE CLUBHOUSE, PROVIDE A SITE PLAN | | | SHOWING THE LOCATION OF THE MAINTENANCE | | | BUILDING IN RELATION TO THE CLUBHOUSE. | | | | | | 6.)HOW WILL THE SHUTTERS BE | | | TRANSPORTED FROM THE MAINTENANCE | | | BUILDING TO THE CLUBHOUSE? | | | | | | 7.)ORIGINAL SIGNED, NOTARIZED OR | | | SEALED (WITH CORPORATE SEAL) DOCUMENTS | | | REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
45 |
Status |
F |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-17 |
Time |
08:47 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-17 |
Time |
08:47 |
Sent To |
PC |
|
| Notes |
| 2005-03-17 00:00:00 | ****CORRECTIONS**** | | | STAIR SHOPS AND HANDRAIL CALCS | | | PREPARED BY DR COWAN, PE 2/16/05 | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)DETAIL B-E1 SHOWS "VARIES" FOR | | | RISER HEIGHTS.RISERS ARE TO BE IN | | | COMPLIANCE WITH FBC1007.3 AND ARE | | | LIMITED IN THE AMOUNT OF VARIATION BY | | | FBC1007.3.3. | | | | | | 2.)FBC1007.5.5, THE HANDRAIL IS TO | | | EXTEND AT LEAST 12" AT THE TOP OF THE | | | FLIGHT; NOTE DIMENSION ON A-E1. | | | | | | 3.)THE CALCULATIONS REFER TO THE WRONG | | | BUILDING CODE (IBC).PLANS ARE TO BE | | | COMPLIANT WITH THE GOVERNING CODE, | | | FBC2001. | | | | | | 4.)PLEASE SEE FBC1608.2.HANDRAILS | | | ARE TO COMPLY WITH FBC1608.2.1 (NO | | | HANDRAIL CALCS PROVIDED) AND GUARDRAILS | | | ARE TO COMPLY WITH FBC1608.2.2 (HANDRAIL | | | DESIGN CRITERIA CALCS PROVIDED FOR | | | GUARDRAILS). | | | | | | 5.)A TITLE BLOCK IS REQUIRED FOR ALL | | | SHEETS IN COMPLIANCE WITH | | | FAC61G15-23.002.SOME INFORMATION | | | MISSING; CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR DR COWAN & ASSOC, PRINTED | | | LICENSE NUMBER FOR THE PERSON SEALING | | | THE DOCUMENT, TITLE BLOCK ON SHEETS E1 | | | AND E2.PLEASE READ THE FAC FOR | | | REQUIREMENTS AND INCLUDE ALL INFORMATION | | | REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
44 |
Status |
P |
Date |
2005-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-09 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-03-09 |
Time |
14:42 |
Sent To |
PC |
|
| Notes |
| 2005-03-09 00:00:00 | DAYBAR 4' DOOR NOA02090401, FL1987, SAME | | | DOOR AS PREVIOUSLY SUBMITEED BUT | | | DIFFERENT INSTALLATION DETAIL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
43 |
Status |
N |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-02 |
Time |
11:43 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-03-02 |
Time |
11:43 |
Sent To |
PC |
|
| Notes |
| 2005-03-02 00:00:00 | DUPLICATE PRODUCT APPROVALS | | | NOA 01-0730.01, STAMPED (ORIG APPROVED | | | 1/11/05) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
42 |
Status |
F |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-11 |
Time |
11:52 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-02-11 |
Time |
11:52 |
Sent To |
PC |
|
| Notes |
| 2005-02-11 00:00:00 | ****CORRECTIONS**** | | | TEST REPORTS FOR DOORS, DOUBLE & SINGLE, | | | CLUBHOUSE ONLY | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)IMPACT PROTECTION REQUIRED FOR | | | GLAZING, FBC1606.1.4.PROVIDE TEST | | | REPORTS AND FLORIDA STATE OR LOCAL | | | PRODUCT APPROVAL, FAC9B72 AND AN | | | INSTALLATION SCHEDULE, SEE ATTACHED. | | | | | | 2.)AN INSTALLATION PLAN FOR HURRICANE | | | PROTECTION APPROVED BY THE BUILDING | | | OFFICIAL IS REQUIRED FOR NON IMPACT | | | GLAZING ON LARGE OR COMMERCIAL | | | BUILDINGS.PLEASE SUBMIT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
41 |
Status |
P |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-11 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-02-11 |
Time |
11:30 |
Sent To |
PC |
|
| Notes |
| 2005-02-11 00:00:00 | NOA 01-0314.02, FL 19 (UNIT) | | | FL 18 (UNIT) | | | | | | FL 19 (CLUBHOUSE) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
40 |
Status |
F |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-25 |
Time |
09:57 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-01-25 |
Time |
09:57 |
Sent To |
PC |
|
| Notes |
| 2005-01-25 00:00:00 | ****CORRECTIONS**** | | | STUCCO SUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)HAVE ALL SUBMITTALS REVIEWED BY DOR | | | OR EOR AS APPLICABLE BEFORE SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
39 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-24 |
Time |
14:54 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-01-24 |
Time |
14:54 |
Sent To |
PC |
|
| Notes |
| 2005-01-24 00:00:00 | REVISED APS4.01 (CORRECT MEAN ROOF | | | HEIGHT) REV 15 DATED 1/5/05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
38 |
Status |
F |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-12 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-01-24 |
Time |
11:09 |
Sent To |
PC |
|
| Notes |
| 2005-01-12 00:00:00 | ****CORRECTIONS**** | | | STUCCO SUBMITTALS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)INCLUDE THE CONTRACTOR'S | | | CERTIFICATE OF APPROVAL FOR THE MAGNA | | | WALL (REQUIRES AN APPROVED APPLICATOR) | | | IN THE SUBMITTAL PACKAGE. | | | | | | 2.)HAVE THE SUBMITTAL REVIEWED BY | | | DOR. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
37 |
Status |
F |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-12 |
Time |
08:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-01-12 |
Time |
08:24 |
Sent To |
PC |
|
| Notes |
| 2005-01-12 00:00:00 | ****CORRECTIONS**** | | | QUICK TIE ENGINEERING PREPARED BY | | | A.BREVNIK, PE | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE TIE DOWN PLAN SUBMITTED | | | CONFLICTS WITH THE STRUCTURAL DETAILS ON | | | THE PLAN.REVISE THE PLAN. | | | | | | 2.)THE TIE DOWN PLAN IS TO BE REVIEWED | | | BY ENGINEER OF RECORD (OLECK). | | | | | | 3.)PLANS PREPARED BY AN ENGINEER ARE | | | REQUIRED TO HAVE A TITLE BLOCK WITH | | | INFORMATION LISTED IN FAC61G15-23.002. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
36 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-11 |
Time |
13:17 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-01-11 |
Time |
13:17 |
Sent To |
PC |
|
| Notes |
| 2005-01-11 00:00:00 | FIRECAULK SUBMITTAL | | | EXTERIOR DOOR NOA01-0730.01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
35 |
Status |
F |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-11 |
Time |
11:32 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-01-11 |
Time |
11:32 |
Sent To |
PC |
|
| Notes |
| 2005-01-11 00:00:00 | ****CORRECTIONS**** | | | HANDRAIL (GUARDRAIL) CALCS PREPARED BY | | | DE COWAN & ASSOCIATES, GEORGIA | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE SEE FS 471 AND FAC61G15; | | | ENGINEERS PRACTICING IN FLORIDA ARE TO | | | HAVE A FLORIDA PE, ENGINEERING COMPANIES | | | ARE TO HAVE A CERTIFICATE OF | | | AUTHORIZATION, DOCUMENTS SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED SEALED | | | AND DATED, TITLE BLOCK IS TO INCLUDE CA | | | NUMBER, DOCUMENT TO INCLUDE PRINTED NAME | | | AND LICENSE NUMBER OF PERSON SEALING THE | | | DOCUMENT. | | | | | | 2.)THIS IS A GUARDRAIL (NOT HANDRAIL), | | | TO BE IN COMPLIANCE WITH FBC1608.2.2 (1) | | | THROUGH (4). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
34 |
Status |
F |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-30 |
Time |
11:30 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-30 |
Time |
11:30 |
Sent To |
PC |
|
| Notes |
| 2004-12-30 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE SPECIFY WHERE THE MAGNA | | | WALL | | | AND THE BROCO STUCCO MIX WILL BE USED. | | | | | | 2.)IT APPEARS THAT YOU ARE CHANGING | | | THE SPECIFICATION FOR THE 1 HR WALL. | | | SUBMIT THIS PACKAGE AS A REVISION. | | | | | | 3.)ONE OF THE COPIES IS FOR A | | | DIFFERENT PROJECT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
33 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-29 |
Time |
16:19 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-29 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2004-12-29 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SHEET APS4.01 DECLARES A MEAN ROOF | | | HEIGHT OF 35'.IT IS MY UNDERSTANDING | | | THAT THE ARCHITECT HAS REVISED THE MEAN | | | ROOF HEIGHT.PLEASE PROVIDE THIS | | | INFORMATION EITHER AS A REVISION TO THE | | | AFFECTED SHEETS OR AS A SIGNED AND | | | SEALED LETTER. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
32 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-29 |
Time |
16:05 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-12-29 |
Time |
16:05 |
Sent To |
PC |
|
| Notes |
| 2004-12-29 00:00:00 | MULLION PRODUCT APPROVALS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
31 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-23 |
Time |
07:41 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-23 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2004-12-23 00:00:00 | FIRESTOP SUBMITTAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
30 |
Status |
F |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-20 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-20 |
Time |
11:12 |
Sent To |
PC |
|
| Notes |
| 2004-12-20 00:00:00 | ****CORRECTIONS**** | | | HURRICANE PROTECTION PLAN | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | PLEASE RESUBMIT ADDRESSED TO NEIL K. | | | MELICK, DIRECTOR/BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
29 |
Status |
P |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-20 |
Time |
07:44 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-20 |
Time |
07:44 |
Sent To |
PC |
|
| Notes |
| 2004-12-20 00:00:00 | SUBMITTALS | | | | | | DOOR SUBMITTAL | | | FIRESSTOP (3 SUBMITTALS) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
28 |
Status |
P |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-13 |
Time |
15:30 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-13 |
Time |
15:30 |
Sent To |
PC |
|
| Notes |
| 2004-12-13 00:00:00 | FIRESTOP SUBMITTAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
27 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-03 |
Time |
09:28 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-12-03 |
Time |
09:28 |
Sent To |
PC |
|
| Notes |
| 2004-12-03 00:00:00 | LOCAL PRODUCT APPROVAL FOR QUIK-TIE | | | APPROVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
26 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-30 |
Time |
09:58 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-30 |
Time |
09:58 |
Sent To |
PC |
|
| Notes |
| 2004-11-30 00:00:00 | ****CORRECTIONS**** | | | TIE DOWN SUBMITTAL | | | | | | 1.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED FAC9B-72.SEE | | | ATTACHED; STATE APPLICATION IS PENDING. | | | I HAVE CONTACTED THE TECHNICAL REP VIA | | | EMAIL REQUESTING THAT HE APPLY FOR A | | | LOCAL PRODUCT APPROVAL.SEE ATTACHED. | | | | | | | | | 2.)A TITLE BLOCK FOR THE ENGINEER IS | | | REQUIRED FAC61G15-23.002. | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
25 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-23 |
Time |
17:40 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-23 |
Time |
17:40 |
Sent To |
PC |
|
| Notes |
| 2004-11-23 00:00:00 | ****CORRECTIONS**** | | | SF2 TRUSS SUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE HAVE THIS SUBMITTAL REVIEWED | | | BY DOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
24 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-17 |
Time |
15:00 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-17 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2004-11-17 00:00:00 | FORM BOARD SURVEY, BLDGS A,D,E,F,G D | | | DATED 10/11/04 | | | AND FORM BOARD SURVEY ALL BLDGS, | | | 10/11/04 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
23 |
Status |
F |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-17 |
Time |
13:38 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-17 |
Time |
13:38 |
Sent To |
PC |
|
| Notes |
| 2004-11-17 00:00:00 | ****CORRECTIONS**** | | | | | | INSTALLATION PLAN FOR HURRICANE | | | PROTECTION | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE CALCULATIONS TO SHOW HOW | | | THE TOTAL NUMBER OF SHUTTERS WAS | | | DETERMINED.INCLUDE THE CLUBHOUSE AND | | | MAINTENANCE BUILDINGS. | | | | | | 2.)INCLUDE THE CLUBHOUSE AND | | | MAINTENANCE BUILDING IN THE | | | CALCULATIONS FOR TIME. | | | | | | 3.)TRAVEL TIME TO LOAD THE WINDOWS | | | AND DISTRIBUTE TO THE BUILDING WAS | | | CALCULATED FOR THE APARTMENT BUILDINGS. | | | INCLUDE THE CLUBHOUSE AND MAINTENANCE | | | BUILDING.ADD THIS TIME TO THE TOTAL | | | INSTALLATION TIME. | | | | | | 4.)BREAKS AND LUNCH HAVE NOT BEEN | | | ACCOUNTED FOR IN THE TIME ANALYSIS. | | | INCLUDING THE TIME FOR THE TWO OTHER | | | BUILDINGS AND SHUTTER TRANSPORT TIME, | | | THE 6 MEN ESTIMATED APPEARS TO BE | | | INSUFFICIENT. | | | | | | 5.)WHERE ARE THE FULL-TIME EMPLOYEES | | | LOCATED?WHERE WILL THEY BE TRAVELLING | | | FROM? | | | | | | 6.)NOTARIZED ORIGINAL SIGNATURES | | | REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
22 |
Status |
F |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-15 |
Time |
15:50 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-15 |
Time |
15:50 |
Sent To |
PC |
|
| Notes |
| 2004-11-15 00:00:00 | ****CORRECTIONS**** | | | TRUSS SUBMITTALS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SUBMITTALS ARE TO BE REVIEWED BY | | | THE DESIGNER OF RECORD. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
21 |
Status |
P |
Date |
2004-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-13 |
Time |
11:37 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-13 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2004-11-13 00:00:00 | CONCRETE SUBMITTAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
20 |
Status |
N |
Date |
2004-11-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-04 |
Time |
07:14 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-11-04 |
Time |
07:14 |
Sent To |
Z |
|
| Notes |
| 2004-11-04 00:00:00 | NOT AN ISSUE WITH MECHANICAL DEPTARTMENT | | | FORWARDED THE PLANS TO ZONING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-03 |
Time |
10:40 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-03 |
Time |
10:40 |
Sent To |
M |
|
| Notes |
| 2004-11-03 00:00:00 | ****CORRECTIONS**** | | | CONDENSER PAD FOUNDATION PLAN | | | | | | 1.)THE SEAL IS REQUIRED TO BE DATED, | | | FAC61G15-23.002. | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-03 |
Time |
08:01 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-03 |
Time |
07:58 |
Sent To |
PC |
|
| Notes |
| 2004-11-03 00:00:00 | ****CORRECTIONS**** | | | PAD DENSITY SUBMITTALS, BLDGS G, H AND | | | I | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | ORIGINALS REQUIRED.PLEASE NOTE THAT | | | ALTHOUGH THE COVER LETTER IS AN | | | ORIGINAL, THE FIELD DENSITY REPORT IS A | | | COPY. | | | | | | SEE ATTACHED IN REGARDS TO PROCEDURES | | | FOR SUBMITTALS FOR THIS PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-02 |
Time |
16:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-02 |
Time |
16:24 |
Sent To |
PC |
|
| Notes |
| 2004-11-02 00:00:00 | REVISION - CHANGE FROM PGT IMPACT TO | | | SUNSHINE IMPACT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
F |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-02 |
Time |
16:07 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2004-11-02 |
Time |
10:58 |
Sent To |
PC |
|
| Notes |
| 2004-11-02 00:00:00 | ****CORRECTIONS**** | | | REVISION - WINDOW/HURRICANE SHUTTERS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
F |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-02 |
Time |
10:11 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-02 |
Time |
09:58 |
Sent To |
PC |
|
| Notes |
| 2004-11-02 00:00:00 | ****CORRECTIONS**** | | | SUBMITTALS - INSPECTION REPORTS | | | ELEVATION CERTIFICATES | | | | | | RE:INSPECTION REPORTS | | | NOT REQUIRED TO BE SUBMITTED FOR PLAN | | | REVIEW.PLEASE CONTACT HAROLD PISKURA | | | FOR PROCEDURES. | | | | | | RE:ELEVATION CERTIFICATES | | | PLEASE PROVIDE A LEGIBLE SEAL, FAC | | | 61G15-23.002. | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-02 |
Time |
09:54 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-02 |
Time |
09:27 |
Sent To |
PC |
|
| Notes |
| 2004-11-02 00:00:00 | CONCRETE SUBMITTALS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2004-10-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-29 |
Time |
15:45 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-10-28 |
Time |
10:24 |
Sent To |
PC |
|
| Notes |
| 2004-10-28 00:00:00 | ****CORRECTIONS**** | | | SOILS REPORTS PREPARED BY ARDAMAN & | | | ASSOCIATES DATED 8/3/04 | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.) ORIGINALS REQUIRED, FAC61G15-23.002. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
N |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
15:34 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-10-13 |
Time |
11:20 |
Sent To |
PC |
|
| Notes |
| 2004-10-13 00:00:00 | WINDOW PRODUCT APPROVALS | | | | | | THE PRODUCT APPROVALS HAVE ALREADY BEEN | | | REVIEWED.IF THIS IS A DIFFERENT | | | PRODUCT (A CHANGE FROM THE ORIGINAL | | | PLAN), PLEASE SUBMIT AS A REVISION. | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:06 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-10-12 |
Time |
13:16 |
Sent To |
PC |
|
| Notes |
| 2004-10-12 00:00:00 | REVISION #10, GNA1.01,APS3.02, APA5.01, | | | APA9.01, APM15.02,APE16.02 DATED | | | 8/24/04 | | | | | | PROVISO - CONTRACTOR TO UPDATE | | | INSPECTION SETS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2004-09-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
16:17 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-09-21 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2004-09-21 00:00:00 | CONCRETE SUBMITTAL | | | LUMBER/FRAMING SPECS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-14 |
Time |
14:09 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-08-17 |
Time |
10:15 |
Sent To |
PC |
|
| Notes |
| 2004-08-17 00:00:00 | POST TENSION TENDON SHOPS | | | PREPARED BY HOSSHANG PRESSWALIA, PE | | | 7/7/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-12 |
Time |
16:43 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-08-12 |
Time |
16:43 |
Sent To |
PC |
|
| Notes |
| 2004-08-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)STUCCO IN A VERTICAL APPLICATION | | | OVER WIRE LATH IS TO BE 3 COAT, 7/8" | | | MINIMUM, FBC2504.2.2, ASTM C926. | | | REVISE AM A1.04, DETAIL W8, AND ANY | | | OTHER DETAILS AFFECTED. | | | | | | 2.)THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT IS TO BE ON THE | | | SHEET.ALSO, SOME SHEETS WERE NOT | | | SEALED. | | | | | | 3.)IN REGARDS TO FORMAT FOR | | | RESUBMITTAL, PLEASE CALL TO DISCUSS | | | (NUMBER OF COPIES, UNDER WHICH PERMIT | | | NUMBER) BEFORE RESUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-07-08 |
Time |
14:03 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-07-08 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-08 |
Time |
11:55 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-05-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2004-05-13 00:00:00 | ****PROVISO**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 3.)ADDITIONAL PERMIT FEES DUE. | | | | | | 4.)SEPARATE PERMITS REQUIRED FOR THE | | | POOL, FENCES AND SIGN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-06 |
Time |
14:49 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-05-06 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2004-05-06 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE A COPY OF THE DEED SHOWING | | | OWNERSHIP. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 4.)SIGN THE OWNER/AGENT LINE OF THE | | | FORM 400A ENERGY CALC. | | | | | | 5.)ENERGY CALC FOR B1-3L-END &B1-3L DO | | | NOT INDICATE FLOOR INSULATION (8A) AS | | | REQUIRED FBC605.1.ABC.1.1. (R11 MIN.) | | | ALSO APPLIES TO UNIT B1-2L, C1-2L. NOTE- | | | NOT A STEM WALL AS INDICATED ON LINE 8A. | | | | | | 6.)SHUTTER PRODUCT APPROVAL REQUIRED | | | FOR THE LOUVERED DOOR. | | | | | | 7.)SEPARATE PERMITS REQUIRED FOR THE | | | POOL, FENCES AND SIGN. | | | | | | 8.)MASTERS CANNOT BE REDLINED.PLEASE | | | REVISED AFFECTED SHEETS AND RESUBMIT. | | | | | | 9.)SEE ATTACHED MUNICIPAL CODE 78-6 IN | | | REGARDS TO SIGNS.THIS IS A COMMENT | | | ONLY, TO BE ADDRESSED WHEN THE SIGN | | | PERMIT IS APPLIED FOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:19 |
Rev Time |
12.00 |
| Received By |
shill |
Date |
2004-04-13 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2004-04-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)AS DISCUSSED WITH OWNER'S | | | REPRESENTATIVE, THE ARCHITECTURAL SITE | | | PLAN WILL BE REMOVED FROM THE PLAN AND | | | SUBSTITUTED WITH THE SITE PLAN PREPARED | | | BY JON E. SCHMIDT AND ASSOCIATES.WE | | | WILL FOLLOW THE NAMING CONVENTION ON | | | THAT SITE PLAN (BUILDINGS A-I, WITH | | | THE CLUBHOUSE AS BUILDING A) AND | | | DISREGARD THE NAMING CONVENTION ON THE | | | CIVILS AND ARCHITECTURALS AS PER OWNER'S | | | REPRESENTATIVE.**SUBJECT TO ZONING** | | | HAVE THE SITE PLAN REVIEWED AND APPROVED | | | BY THE DESIGNER OF RECORD.HAVE A NOTE | | | PROVIDED ON THE SITE PLAN REFERRING TO | | | THE CIVIL PAVING PLAN FOR SIDEWALK | | | ELEVATIONS. | | | | | | 2.)PROVIDE A COPY OF THE DEED SHOWING | | | OWNERSHIP. | | | | | | 3.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 5.)THE ENERGY CALCS SUBMITTED ARE NOT | | | CORRECT.THERE SHOULD BE A DIFFERENT | | | EN CALCS FOR THE 1ST, 2ND AND 3RD FLOOR | | | UNITS AS THE INSULATION IS DIFFERENT FOR | | | EACH.THERE SHOULD BE FLOOR INSULATION | | | INDICATED FOR 2ND AND 3RD FLOOR, NOT NA. | | | THERE SHOULD BE UNDER ATTIC INSULATION | | | FOR THE 3RD AND 2ND FLOOR UNITS AS | | | APPLICABLE, BUT 1ST FLOOR HAVE A SINGLE | | | ASSEMBLY.SUBMIT CORRECTED ENERGY | | | CALCS.PLEASE PROVIDE A PRINTED NAME, | | | ADDRESS, LICENSE NUMBER FOR THE PERSON | | | PREPARING THE ENERGY CALC ON THAT SHEET. | | | REFER TO THE PERMIT NUMBERS AND PROVIDE | | | ONE EXTRA COPY OF THE FIRST SHEET OF | | | EACH ENERGY CALC FOR SUBMITTAL TO THE | | | STATE, FBC13. | | | | | | 6.)LINE 9B, UNIT C1, INDICATES 0 | | | INSULATION, NONCOMPLIANT WITH FBC13 | | | CHAPTER 6 (METHOD 600A, ENERGY CALC). | | | | | | 7.)THE FORM 400A INDICATES A NET AREA | | | OF 2979; THE PLAN (CH A5.01) INDICATES | | | AN A/C AREA OF 3546 (METHOD 400A | | | ENERGY CALC). | | | | | | 8.)THE MEDIAN ROOF HEIGHT IS GIVEN AS | | | 35', AP S4.01.TABLES 1606.2B AND | | | TABLE 1606.2C ARE LIMITED TO BUILDINGS | | | WITH A MEAN ROOF HEIGHT OF LESS THAN | | | 30'. ADDRESS.THE PRODUCT APPROVALS FOR | | | THE WINDOWS AND DOORS CANNOT BE | | | REVIEWED UNTIL DESIGN PRESSURES ARE | | | PROVIDED. (APARTMENT BUILDINGS) | | | | | | 9.)DESIGN PRESSURES FOR THE APARTMENT | | | AND CLUBHOUSE ROOFS HAVE NOT | | | BEEN PROVIDED.TABLE 1606.2C INDICATES | | | PRESSURES IN THE -50S; NOA 02-0328.05 | | | SUBMITTED (ROOF TILE, CLUBHOUSE) HAS | | | A LIMITATION OF 45.8.PROVIDE A ROOF | | | DESIGN PRESSURE FOR BOTH BUILDINGS. | | | PROVIDE COMPLIANT PRODUCT APPROVALS OR | | | SEPARATE PERMITS FOR THE ROOFS WILL | | | BE REQUIRED. | | | | | | 10.)DETAIL 7, SHEET CH S4.01 LACKS A | | | ZONE 3 FOR THE HIP ROOF, SEE FBC FIG. | | | 1606.2. (SEE PREVIOUS LIST, ITEM 18). | | | | | | 11.) THE PRODUCT APPROVAL FOR THE ROOF | | | SHINGLES SUBMITTED (NOA02-1216.05) HAS | | | A LIMITATION (4.2), "SHALL NOT BE | | | INSTALLED ON ROOF MEAN HEIGHTS IN | | | EXCESS OF 33 FT."THIS PRODUCT APPROVAL | | | IS ACCEPTABLE FOR THE MAIL KIOSK BUT | | | NOT THE APARTMENT BUILDINGS.ADDRESS. | | | | | | 12.) A PROVISO HAS BEEN ADDED TO YOUR | | | PRODUCT APPROVALS THAT ALL WINDOWS | | | ARE TO BE IMPACT GLASS AS PER YOUR | | | ARCHITECT'S LETTER. | | | | | | 13.) THE PRODUCT APPROVALS SUBMITTED | | | PREVIOUSLY NEED FLORIDA STATEWIDE, LOCAL | | | OR SITE SPECIFIC PRODUCT APPROVALS | | | FAC9B-72. | | | | | | 14.) SUBMIT THE FOLLOWING PRODUCT | | | APPROVALS: | | | GARAGE DOOR (MAINT BLDG) | | | LOUVERED DOOR (MAIL KIOSK) | | | | | | 15.)SEPARATE PERMITS REQUIRED FOR THE | | | POOL, FENCES AND SIGN. | | | | | | 16.)PRODUCT APPROVALS NOT SUBMITTED | | | PROPERLY FOR REVIEW BEFORE PERMIT | | | ISSUANCE WILL REQUIRE SEPARATE PERMITS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-03-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-12 |
Time |
16:07 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2004-03-12 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2004-03-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)DUE TO THE SCOPE AND NATURE OF THE | | | PROPOSED WORK THE BUILDING OFFICIAL WILL | | | REQUIRE A RESIDENT INSPECTOR AS PROVIDED | | | FOR IN FBC 105.3 AS AMENDED BY THE CITY | | | OF WEST PALM BEACH.CONTACT HAROLD | | | PISKURA FOR MORE INFORMATION, | | | 561-805-6711.THIS MUST BE DONE BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 2.)NOTE 10, LUMBER AND FRAMING, SHEET | | | AP/A1.03 HAS BEEN REVISED TO STATE | | | "NON BEARING", BUT PER OUR CONVERSATION | | | MUST BE ALSO FOR INTERIOR WALLS ONLY. | | | | | | 3.)SEE PREVIOUS LISTS IN REGARDS TO | | | THE REQUEST FOR TOPOGRAPHICAL | | | AND DIMENSIONAL INFORMATION PERTINENT | | | TO BUILDING LOCATION AND ACCESSIBILITY. | | | THE TRANSMITTAL LETTER INDICATES THAT | | | THE CIVIL DRAWINGS HAVE BEEN REVISED. | | | AS CIVIL DRAWINGS ARE NOT A PART OF THIS | | | PACKAGE, PLEASE REVISE THE | | | ARCHITECTURALS TO PROVIDE THIS | | | INFORMATION AS REQUIRED BY FBC TABLE | | | 600 AND CHAPTER 11. | | | | | | 4.)BEFORE A PERMIT TO CONSTRUCT CAN | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 5.)DUMPSTER REQUIRES A SEPARATE | | | PERMIT. | | | | | | 6.)THE FOLLOWING PRODUCT APPROVALS | | | WERE NOT SUBMITTED: | | | ROOF | | | SHUTTERS, IF APPLICABLE | | | SINGLE HUNG WINDOWS | | | MULLIONS | | | | | | FLORIDA STATEWIDE, LOCAL OR SITE | | | SPECIFIC PRODUCT APPROVAL REQUIRED. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.)SEE PREVIOUS LIST, PROVIDE A COPY | | | OF THE RECORDED PLAT FOR ADDRESSING | | | PURPOSES. | | | | | | 8.)ADDITIONAL FEES DUE. | | | | | | 9.)SEE PREVIOUS LIST, ITEM #11, | | | THERE ARE STILL REFERENCES ON THE | | | PLAN TO THE EXPIRED MAGNA WALL 1997 (FOR | | | INSTANCE, W-10 AP A1.04, W-1 AM A1.04). | | | | | | 10.) SEE PREVIOUS LIST, ITEM #12. | | | IMPACT PROTECTION REQUIRED.2ND AND 3RD | | | FLOOR REQUIRES IMPACT GLASS.SEE | | | ATTACHED POLICY IN REGARDS TO MISSILE | | | IMPACT PROTECTION, ITEM #13.THE | | | INSTALLATION PLAN FOR HURRICANE | | | PROTECTION IS REQUIRED TO BE APPROVED | | | BEFORE PERMIT ISSUANCE. | | | | | | 11.)SEE PREVIOUS LIST, PROVIDE | | | FIRE RATING INFORMATION FOR DOOR TYPE | | | D, AP9.01. | | | | | | 15.)SEE PREVIOUS LIST, FASTENING FOR | | | SIMPSON CS16 (AP S4.01) CONFLICTS WITH | | | THE CATALOG.ADDRESS - EITHER CHANGE | | | TO BE CONSISTENT WITH THE MFGR SPEC OR | | | SUBMIT CALCULATIONS.CHECK ALL | | | CONNECTORS. | | | | | | 16.)SEE PREVIOUS LIST, PROVIDE A | | | SOILS INVESTIGATION REPORT, FBC104.3.1.1 | | | (8). | | | | | | 17.)PROVIDE A SURVEY FOR THIS | | | PROPERTY. | | | | | | 18.)S4.01, THE HIP ROOF DOES NOT | | | INDICATE A ZONE 3. | | | | | | 19.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | | | | 20.)THE PRINTED NAME AND LICENSE # | | | OF THE PERSON SEALING THE PLAN IS | | | REQUIRED TO BE ON EACH SHEET, FAC | | | 61G1-16.003, 004. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-20 |
Time |
10:16 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2004-01-20 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2004-01-20 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)DUE TO THE SCOPE AND NATURE OF THE | | | PROPOSED WORK THE BUILDING OFFICIAL WILL | | | REQUIRE A RESIDENT INSPECTOR AS PROVIDED | | | FOR IN FBC 105.3 AS AMENDED BY THE CITY | | | OF WEST PALM BEACH.CONTACT HAROLD | | | PISKURA AT 561-805-6711 FOR MORE | | | INFORMATION. | | | | | | 2.)SEE PREVIOUS LIST, ITEM #3.THE | | | CODE REFERENCED IS LIMITED TO 100 MPH | | | WIND ZONE.ALTHOUGH YOU STATE IN THE | | | RESPONSE LETTER THAT THIS IS FOR NON | | | CRITICAL AREAS, THE SPECIFICATION ON | | | THE PLAN IS NOT CODE COMPLIANT. | | | | | | 3.)SEE PREVIOUS LIST, ITEM #5. | | | PROVIDE INFORMATION AS PER FBC103.7 | | | FOR SUBMITTAL TO THE BUILDING OFFICIAL | | | FOR APPROVAL OR PROVIDE A RATED SHAFT | | | ENCLOSURE COMPLYING WITH FBC705.2.2 | | | AS REQUESTED. | | | | | | 4.)SEE PREVIOUS LIST, ITEM #6. | | | THE RESPONSE SHEET INDICATED THAT CIVIL | | | DRAWINGS WITH TOPOGRAPHICAL AND | | | DIMENSIONAL INFORMATION PERTINENT TO | | | BUILDING LOCATIONS AND HANDICAP | | | ACCESSIBILITY WOULD BE PROVIDED.NONE | | | HAS BEEN PROVIDED AT THIS TIME. | | | | | | 5.)SEE PREVIOUS LIST, ITEM #10. | | | INFORMATION WAS GIVEN FOR HANDRAILS BUT | | | NOT FOR THE GUARDRAILS, FBC1608.2.2. | | | (A1.03) | | | | | | 6.)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 7.)SEPARATE PERMIT REQUIRED FOR EACH | | | STRUCTURE.FYI, THE DUMPSTER HAS NOT | | | BEEN APPLIED FOR.UNTIL ALL PLAN | | | REVIEWS HAVE BEEN PASSED, IT IS | | | RECOMMENDED (BUT NOT REQUIRED) THAT | | | A RESUBMITTAL BE DONE ON ONE PERMIT ONLY | | | TO AVOID RESUBMITTAL FEES.AFTER THIS | | | PLAN HAS PASSED ALL TRADES, ONE PLAN | | | FOR EACH BUILDING MUST BE SUBMITTED AS | | | WELL THREE FOR THE FIRST BUILDING | | | (MASTER).THE CLUBHOUSE, MAINTENANCE | | | BUILDING AND SITE AMENITIES PERMITS | | | ARE TO HAVE THREE SETS OF PLANS | | | SUBMITTED WITH THE PLANS FOR THAT PERMIT | | | ONLY INCLUDED.PLEASE CALL 805-6724 IF | | | YOU HAVE ANY QUESTIONS ABOUT THIS | | | PROCEDURE. | | | | | | BEFORE THE PERMIT IS ISSUED, ALL OLD/ | | | VOIDED SHEETS ARE TO BE REMOVED FROM | | | THE PLANS. | | | | | | 8.)SEE PREVIOUS LIST, ITEM #14.IF | | | PRODUCT APPROVALS ARE NOT SUBMITTED, | | | SEPARATE PERMITS FOR THE DOORS, WINDOWS, | | | IMPACT PROTECTION, ROOF COVERING WILL | | | BE REQUIRED.SOME PRODUCT APPROVALS | | | WERE SUBMITTED BUT NOT ALL THAT ARE | | | REQUIRED. | | | | | | FLORIDA STATEWIDE OR SITE SPECIFIC | | | APPROVALS REQUIRED, RULE 9B-72.SEE | | | THE DCA WEBSITE AT WWW.FLORIDABUILDING. | | | ORG FOR MORE INFORMATION.SUBMIT THE | | | FLORIDA PRODUCT APPROVAL WITH THE | | | NOA. | | | | | | A SEPARATE PACKAGE OF PRODUCT APPROVALS | | | WILL BE REQUIRED FOR THE MAINTENANCE | | | BUILDING, CLUBHOUSE, AND AMENITIES. | | | | | | 9.)PROVIDE A COPY OF THE RECORDED | | | PLAT FOR ADDRESSING PURPOSES. | | | | | | 10.) ADDITIONAL FEES DUE (VALUE | | | ADJUSTMENT, RADON). | | | | | | 11.) THERE ARE REFERENCES ON THE PLAN | | | TO THE EXPIRED MAGNA WALL 1997 (FOR | | | INSTANCE, W-10 AP A1.04, W-1 AM A1.04). | | | | | | 12.) IMPACT PROTECTION REQUIRED FOR | | | GLAZING FBC1606.1.4.HURRICANE SHUTTER | | | SCHEDULE REQUIRED WITH TEST REPORTS AND | | | FLORIDA PRODUCT APPROVAL TO BE A PART | | | OF THIS PERMIT; OTHERWISE WILL REQUIRE | | | SEPARATE PERMITS. SEE ATTACHED | | | SCHEDULE FOR INSTALLATION OF OPENING | | | PROTECTIVE DEVICES OR ASSEMBLIES. | | | | | | 13.)SEE ATTACHED POLICY IN REGARDS | | | TO MISSILE IMPACT PROTECTION, ITEM #13. | | | THE PLAN REFERRED TO IS TO BE SUBMITTED | | | AND APPROVED BEFORE PERMIT ISSUANCE. | | | | | | 14.)PROVIDE TEST REPORT, FLORIDA | | | STATEWIDE OR SITE SPECIFIC, AND FIRE | | | RATING INFORMATION FOR DOOR TYPE D | | | (AP9.01). | | | | | | 15.)FASTENING FOR SIMPSON CS16 (SHEET | | | AP S4.01) CONFLICTS WITH THE CATALOG. | | | ADDRESS - EITHER CHANGE TO BE CONSISTENT | | | WITH MFGR SPEC, OR SUBMIT CALCULATIONS. | | | CHECK ALL CONNECTORS. | | | | | | 16.)PROVIDE A SOILS INVESTIGATION | | | REPORT, FBC104.3.1.1(8). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-11-24 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-11-24 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2003-11-24 00:00:00 | PLAN REVIEW ONLY, NOT A PERMIT | | | APPLICATION.AT TIME OF PERMIT | | | APPLICATION THE FOLLOWING COMMENTS MAY | | | BE ADDRESSED ON THE PLANS. | | | | | | DUE TO THE SCOPE AND NATURE OF THE | | | PROPOSED WORK THE BUILDING OFFICIAL | | | WILL REQUIRE A RESIDENT INSPECTOR AS | | | PROVIDED FOR IN FBC 105.3 AS AMENDED BY | | | THE CITY OF WEST PALM BEACH.CONTACT | | | HAROLD PISKURA AT 561-805-6665 FOR MORE | | | INFORMATION. | | | | | | SHEET A1.03 DOES NOT CITE THE CORRECT | | | EDITION OF THE STANDARDS INVOKED BY THE | | | 2001 FBC.EXAMPLE, ACI 318-02 NOT THE | | | 1995 EDITION.PLEASE REVISE AND ENSURE | | | COMPLIANCE AS NECESSARY, INCLUDING | | | CONCRETE COVERAGE AND LAP.SEE FBC | | | 3500. | | | | | | THE CITY OF WEST PALM BEACH HAS AMENDED | | | FBC TABLE -2307.6B.THE MINIMUM | | | THICKNESS STRUCTURAL PANEL IS 19/32" | | | FOR 16" OC SPACING, NOT THE DECLARED | | | 7/16".SEE ALSO FBC 2301.1.2 AND THE | | | 100 MPH LIMITATION WITH REGARDS TO THE | | | NAILINGSCHEDULE ON SHEET A1.03 NOTE | | | #10. | | | | | | SHEET A1.05. THE NER -459 REPORT FOR | | | THE MAGNA WALL SHOWN IS EXPIRED. | | | PROVIDE AN ACCEPTANCE REPORT SUITABLE | | | FOR THE FBC. | | | | | | THE BATH EXHAUST PENETRATION DETAIL ON | | | SHEET A1.06 AND DETAIL 3/A7.03 IS NOT | | | AN ACCEPTABLE ALTERNATE METHOD UNDER | | | FBC 103.7 GIVEN THE 30 GA DUCT | | | MATERIAL.PLEASE PROVIDE A FIRE RATED | | | SHAFT ENCLOSLURE COMPLYING WITH FBC 705. | | | 2.2. | | | | | | SHEET A2.01.PLEASE PROVIDE DIMENSIONS | | | ON THE SITE PLANS SHOWING THE DISTANCE | | | BETWEEN BUILDINGS AND PROPERTY LINES. | | | ALSO SHOW THE PERITNENT TOPOGRAPHIC | | | FEATURES SOTHAT HANDI CAP ACCESSIBILITY | | | MAY BE DETERMINED. | | | | | | THE PLANS AS SHOWN DO NOT MEET THE | | | MINIMUM EGRESS REQUIREMENTS.FBC | | | 1004.1.4 REQUIRES THE EXITS TO BE A | | | DISTANCE APART EQUAL TO OR GREATER THAN | | | 1/2 THE DIAGONAL DISTANCE SERVED.TWO | | | INDEPENDENT EXITS ARE REQUIRED FROM THE | | | THIRD FLOOR, SEE FBC 1004.2.1 AND | | | 1026.1.1, #4. | | | | | | THE STAIRS ARE REQUIRED TO BE ENCLOSED | | | IN FIRE RATED CONSTRUCTION, SEE FBC | | | 1006.1.THEY DO NOT MEET THE CRITERIA | | | FOR ESXTERIOR STAIRS IN FBC 1006.2 AND | | | FBC 1014.SEE ALSO, FBC 1007.1.2 RE: | | | CLOSED RISERS. | | | | | | SHEET A7.02, SHOW A SPECIFIC METHOD FOR | | | INSTALLATION OF THE FIRE BLOCKING. DO | | | NOT QUOTE THE CODE SECTION, SEE FBC 104. | | | 2.1. | | | | | | SEE FBC 1608.2 FOR THE MINIMUM DESIGN | | | LOADS FOR HAND AND GUARD RAILS. | | | | | | SHOW THE FIRE SPRINKLER DESIGN ON THE | | | PERMIT PLANS, INCLUDE THE MINIMUM | | | INFORMATION IN CHAPTER TWO OF NFPA | | | 13R-99. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO THE | | | COUNTY, THE PERMIT PLANS STAMPED BY | | | THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. | | | | | | SEPARATE PERMITS WILL BE REQUIRED FOR | | | EACH STRUCTURE. | | | | | | IF NOTICE OF ACCEPTANCE REPORTS ARE NOT | | | INCLUDED FOR THE DOORS, WINDOWS AND ROOF | | | COVERINGS, SEPARATE PERMIT INFORMATION | | | AND FEES WILL BE REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-16 |
Time |
09:59 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-05-16 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2005-05-16 00:00:00 | ****** REV UNSAT ********** | | | | | | 1)NOTE: PLANS CAME IN FOR REVISION UNDER | | | MASTER/PROJECT. | | | PLEASE SEE REVSIONS CAN NOT BE MADE TO A | | | PROJECT/MASTER. PLEASE SUBMIT REVSIONS | | | UNDER EACH BLDG PERMIT. | | | | | | 2)NOTE: PLEASE SEE ELECTRICAL PLANS NOT | | | SIGNED AND SEALED BY THE ENGINEER OF | | | RECORD. | | | FS 471.025 | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
N |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-23 |
Time |
05:34 |
Rev Time |
0.05 |
| Received By |
dpalmer |
Date |
2004-12-23 |
Time |
05:34 |
Sent To |
B |
|
| Notes |
| 2004-12-23 00:00:00 | SUBMITTAL FOR BLDG FIRE STOPPING | | | SUBMITTED TO ELECTRICAL, THIS HAS BEEN | | | SENT TO BLDG REVIEWER SHILL. | | | THIS IS NOT AN ELECTRICAL SUBMITTAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-28 |
Time |
17:34 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-28 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE PLANS ARE COMING IN | | | AS A REVISION FOR MASTER. | | | MAY NOT REVISE MASTER. | | | PLEASE ALSO SEE ONLY TWO SETS OF PLANS | | | WERE SUBMITTED. | | | E-SHEETS STAMPED IN ERROR. VOIDED SHEETS | | | | | | | | | PLEASE SUBMIT REVISION UNDER BLDG/CH | | | PERMIT #. | | | PLEASE SEE ARCG SHEES NOT SEALED. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
13:05 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-05-13 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
16:02 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2004-05-08 00:00:00 | *********** UNSAT ******************* | | | | | | 1)NOTE: NO EQUIPMENT GROUNDING CONDUCTOR | | | FROM METER TO MAIN/ FIRST MEANS OF | | | DISCONNECT. 250.6,250.24 | | | | | | 2)NOTE: PLEASE SHOW/INDICATE ALL RECCEPT | | | -S SHOWN IN GARAGE AS GFI/GFI PROTECTED | | | 210.8 | | | | | | 3 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | PLEASE SEE ALL SHEETS, ADJUST ALL LOADS | | | CALCS. | | | | | | 4)NOTE: PLANS INDICATE NOTE FOR EM LTS | | | TO BE WIRED AHEAD OF LOCAL CIRCUITS, | | | PLEASE SHOW CIRCUIT #'S. | | | | | | 5)NOTE: PLEASE SEE LOADS SHOWN FOR HP | | | E16.02 PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42,210.19A,210.20A ETC | | | | | | 6)NOTE: PLEASE SEE E16-.02, NOTE MENTION | | | -S NO ALUM FOR GROUNDING OR BONDING, | | | YET FEEDER SCHEDULE STILLS NOTES AND | | | DEATILS ALUM AS EQUIPMENT GRNDS. | | | | | | 7)NOTE: PLEASE SEE AP E16.00. | | | PLEASE INDICATE RATING OF POLES AND LTS | | | TO BE RATED FOR FBC 140 MPH. | | | | | | PLANS HAVE NOW BEEN CHANGED TO BE A | | | MASTER. ALL CORRECTIONS MUST BE DONE, | | | NO REDLINES CAN BE DONE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-08 |
Time |
11:00 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-03-08 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | *** REDLINED ** | | | | | | MAINT BLDG RISER, NO EQUIPMENT GROUNDING | | | FROM METER TO MAIN. 250.24, 250.6 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-05 |
Time |
12:12 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2004-01-05 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2004-01-05 00:00:00 | ************** UNSAT ********** | | | | | | PLEASE SEE THAT SOME NOTES FROM FIRST | | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE THAT IT APPEARS | | | SOME OF THE CORRECTIONS WERE MADE TO | | | SOME SHEETS AND THOSE SHEETS WERE | | | INSERTED, HOWEVER A NEW AP16.02 WAS NOT | | | SUBMITTED. PLEASESEE THE FOLLOWING | | | COMMENTS. | | | | | | 2)NOTE: PLEASE SEE RESPONSE #1 , | | | MENTIONS SHOWN ON AP E16.01, COMMENT | | | HAD TO DO WITH CLUBHOUSE PLANS. | | | COMMENT HAS NOT BEEN ADDRESSED, PLEASE | | | SEE 700.12E. | | | | | | 3)NOTE: PLEASE SEE THE REVISED NEW | | | SHEETS FOR APE16.02 WAS NOT SUBMITTED, | | | OTHER REVISED RISER DIAGRAMS DID MAKE | | | SOME OF THE CHANGES, BUT UNABLE TO | | | VERIFY ON AP SHEET. | | | 250.50 | | | PLEASE ALSO SEE MIN SIZE OF CONDUCTORS | | | FOR ALUM AND ALSO FOR GROUNDING/BONDING. | | | 310.2 | | | | | | 4)NOTE: PLEASE SEE NOTE ON AP E16.02, | | | STILL NOTES, RECEPTS TO BE ARC FAULT | | | PROTECTED. IT HAS BEEN NOTED ON AP E-16. | | | 01. | | | | | | 5)NOTE: PLEASE PROVIDE AWG ON PANEL | | | SCHEDULES AND CORRELATE WITH OCP. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS FOR 3 COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-23 |
Time |
06:37 |
Rev Time |
3.00 |
| Received By |
dpalmer |
Date |
2003-10-23 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2003-10-23 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULES. | | | PLEASE SEE 700.12 FOR CIRCUITING OF | | | EM/EXT LTS. | | | | | | 2)NOTE: PLEASE CLARIFY LIGHTING IN ELEC | | | RM PER 700.16 | | | | | | 3)NOTE: PLEASE SEE SERVICE SHOWN ON | | | PLAN LAYOUT. SHOWS FPL TRANSFORMER | | | MOUNTED IN BETWEEN METER AND MAINS? | | | PLEASE CORRELATEWITH RISER. | | | | | | 4)NOTE: PLEASE INCLUDE FOOTER STEEL | | | AS PART OF THE GROUNDING ELECTRODE | | | SYSTEM AS REQ'D PER 250.50. THIS IS FOR | | | THE MAINT BLDG AND CLUBHOUSE. | | | | | | 5)NOTE: PLEASE SEE PANEL SCHEDULE FOR | | | PANEL "A", SHOWN AS MCB AND RISER SHOWS | | | MLO. PLEASE CORRELATE. A MCB IS PERMITT- | | | -EDBU T NOT REQ'D. IF SHOWN THEN IT | | | WILL BE REQ'D TO BE INSTALLED. | | | | | | 6)NOTE: PLEASE INCREASE SEC'S TO NEXT | | | SIZE UP. NEXT SIZEUP FOR SEC'S WOULD | | | BE 700A (240.6) AND SERVICE IS SHOWN | | | AS BEING "800A'S". 240.42,230.43, SIZE | | | PER 310.16 | | | | | | 7)NOTE: PLEASE PROVIDEAIC RATINGS FOR | | | ALL SERVICE EQUIPMENT. MAINS/ PANELS/ | | | BRKRS ARE ALL TO BE RATED FOR THE | | | AVAILABLE FAULT CURRENT. 110.9 | | | PLEASE ALSO INCLUDE FOR EQUIP ON E16.01 | | | | | | 8)NOTE: PLEASE SEE THAT MAIL KIOSK WILL | | | REQUIRE A MEANS OF DISC PER 225.31 | | | | | | 9)NOTE:PLEASE SEE MISSING SDE'S INSIDE | | | AND OUTSIDE ALL SLEEPING RMS. NFPA-72 | | | 8-1.4.2 | | | | | | 10)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | APTS UNITS ALSO AND CORRELATE. | | | | | | 11)NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%. 215.3/230.42 ETC | | | | | | 12)NOTE: PLEASE NOTE, PER LOCAL AMEND- | | | -MENTS. ALUMINUM CONDUCTORS ARE NOT TO | | | BE USED FOR GROUNDING OR BONDING.310.2 | | | NONE SMALLER THAN #2 FOR ALL OTHERS. | | | | | | 13)NOTE: PLEASE SEE 250.50 FOR REQ'D | | | ATTACHMENTS FOR GROUNDING ELECTRODE | | | SYSTEM. | | | | | | 14)NOTE: PLEASE SEE NOTE ON PLAN MENTION | | | (S) TO PROTECT BEDROOM RECEPTS FOR ARC | | | FAULT. PER 210.12 | | | PLEASE SEE THAT WE ARE NOW UNDER THE | | | 2002 NEC AND REQUIREMENTS FOR 210.12 | | | HAS CHANGED. | | | | | | 15)NOTE: PLEASE PROVIDE WIRE SIZES ON | | | PANEL SCHEDULE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | PLEASE SEE NOTES FROM OTHER REVIEWERS | | | AS COMMENTS MAY AFFECT ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-04-14 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-04-14 00:00:00 | PASSED : | | | 1. SEE # 04040584 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-02-23 |
Time |
09:11 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-02-23 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2004-02-23 00:00:00 | FAILED: | | | 1. PLEASE SEE PREVIOUS REVIEW COMMENTS | | | DATED 10-15-03. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-12-18 |
Time |
10:47 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-12-18 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2003-12-18 00:00:00 | FAILED: | | | 1. PLEASE SEE THE PREVIOUS REVIEW | | | COMMENTS DATED 10-15-03. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-10-15 |
Time |
10:27 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-10-15 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2003-10-15 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE CIVIL/SITE ENGINEERING | | | PLANS FOR OUR REVIEW AND APPROVAL, ALSO | | | SUBMIT TWO SETS TO PUBLIC UTILITIES AND | | | ENGINEERING FOR THEIR REVIEW AND ALL THE | | | CONNECTION TO CITY SERVICES, ATT: MANNY | | | GONZALEZ, 659-8040 EX 2306. | | | 2. PLEASE SUBMIT STORM WATER CALCULATION | | | ,IT SHOULD INCLUDE PERVIOUS, IMPERVIOUS | | | AND TOTAL SITE AREA. | | | 3. PLEASE SUBMIT A COPY OF THE SFWMD | | | PERMIT. | | | 4. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR "UNDERGROUND | | | UTILITIES AND SITE WORK" PERMIT IS | | | REQUIRED, PLEASE SUBMIT TWO SETS OF | | | CIVIL PLANS ONLY, SIGNED & SEALED. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-02-24 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-02-24 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-01-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-15 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-15 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2004-01-15 00:00:00 | PLAN WAS ORIGINALLY REVIEWED ON | | | 12.24.03. | | | | | | 1) SITE PLAN DOES NOT SHOW REQUIRED | | | FIRE HYDRANTS. | | | | | | 2) FIRE EXTINGUISHERS IN CABINETS SHALL | | | BE A MINIMUM OF 5 LBS. NOT 4 LBS. | | | AS SHOWN ON THE PLANS. | | | | | | 3) TACTILE SIGNAGE REQUIRED AT | | | STAIRWAYS. | | | | | | 4) BUILDING ADDRESS IS REQUIRED ON | | | CLUBHOUSE. | | | | | | 5) AUDIBLE AND VISUAL FIRE ALARM | | | DEVICES ARE REQUIRED IN HANDICAP | | | APARTMENTS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-10-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-30 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-30 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2003-10-30 00:00:00 | 1) SITE PLAN DOES NOT INDICATE FIRE | | | HYDRANTS OR FIRE LINES. | | | | | | 2) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 3) BUILDING ADDRESSES SHALL BE A | | | MINIMUM OF 6" HIGH. | | | | | | 4) PLEASE INDICATE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR HANDRAILS | | | AND GUARDRAILS. | | | | | | 5) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING AND AFTER CONSTRUCTION. | | | | | | 6) SUITABLE ROADS ARE TO BE PROVIDED | | | DURING CONSTRCTION FOR FIRE AND | | | PARAMEDICAL ACCESS. | | | | | | 7) BUILDING ADDRESS REQUIRED ON | | | CLUBHOUSE. | | | | | | 8) ALL FIRE ALARM SYSTEMS THAT SUPERVISE | | | AUTOMATIC FIRE SPRINKLER SYSTEMS SHALL | | | BE LISTED FOR CENTRAL STATION SERVICE. | | | | | | 9) SMOKE DETECTORS WERE NOTED TO BE | | | MISSING FROM THE BEDROOMS. | | | | | | 10) NO FIRE SPRINKLER SYSTEM DRAWINGS | | | PROVIDED WITH PLANS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
50 |
Status |
N |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-20 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-20 |
Time |
09:27 |
Sent To |
B |
|
| Notes |
| 2005-07-20 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
49 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
16:36 |
Sent To |
B |
|
| Notes |
| 2005-06-01 00:00:00 | TO "SHILL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
48 |
Status |
N |
Date |
2005-05-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-10 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-10 |
Time |
15:55 |
Sent To |
E |
|
| Notes |
| 2005-05-10 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
47 |
Status |
N |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-20 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-20 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2005-04-20 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
46 |
Status |
N |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-06 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-06 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2005-04-06 00:00:00 | TO "SHILL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
45 |
Status |
N |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-16 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-16 |
Time |
16:22 |
Sent To |
B |
|
| Notes |
| 2005-03-16 00:00:00 | TO SHILL DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
44 |
Status |
N |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-16 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-16 |
Time |
14:37 |
Sent To |
E |
|
| Notes |
| 2005-03-16 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
43 |
Status |
N |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-28 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-28 |
Time |
12:26 |
Sent To |
B |
|
| Notes |
| 2005-02-28 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
42 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2005-02-04 00:00:00 | TO SHILL DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
41 |
Status |
N |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-25 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-25 |
Time |
07:46 |
Sent To |
B |
|
| Notes |
| 2005-01-25 00:00:00 | TO "SH" DESK/SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
40 |
Status |
N |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-18 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-18 |
Time |
16:03 |
Sent To |
M |
|
| Notes |
| 2005-01-18 00:00:00 | TO "M/AC" BOX./REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
39 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-11 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-11 |
Time |
14:09 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | TO "SH" DESK./SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
38 |
Status |
N |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-07 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-07 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
| 2005-01-07 00:00:00 | TO "SH" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
37 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
14:02 |
Sent To |
B |
|
| Notes |
| 2004-12-29 00:00:00 | TO "SH" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
36 |
Status |
N |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-27 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-27 |
Time |
09:19 |
Sent To |
B |
|
| Notes |
| 2004-12-27 00:00:00 | TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
35 |
Status |
N |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-23 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-23 |
Time |
09:20 |
Sent To |
B |
|
| Notes |
| 2004-12-23 00:00:00 | SENT TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
34 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-21 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-21 |
Time |
13:39 |
Sent To |
M |
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "M/AC" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
33 |
Status |
N |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-17 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-17 |
Time |
15:55 |
Sent To |
B |
|
| Notes |
| 2004-12-17 00:00:00 | SENT TO "SH" DESK.ALSO ONE SUBMITTAL TO | | | "DP" DESK, AND ONE SET TO "M/AC" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
32 |
Status |
N |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-16 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-16 |
Time |
07:45 |
Sent To |
B |
|
| Notes |
| 2004-12-16 00:00:00 | SENT TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-13 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-13 |
Time |
08:47 |
Sent To |
B |
|
| Notes |
| 2004-12-13 00:00:00 | SENT TO "SH" DESK/SUBMITTAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-22 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-22 |
Time |
15:56 |
Sent To |
B |
|
| Notes |
| 2004-11-22 00:00:00 | SENT TO "SH" DESK/SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-18 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-18 |
Time |
15:50 |
Sent To |
B |
|
| Notes |
| 2004-11-18 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-16 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-16 |
Time |
14:15 |
Sent To |
B |
|
| Notes |
| 2004-11-16 00:00:00 | SENT TO "B" TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-15 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-15 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2004-11-15 00:00:00 | TO SH DESK/4 SUBMITTALS/ | | | ELEVATION CERTS | | | 1 SUBMITTAL/TRUSS BEAM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-02 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-02 |
Time |
16:45 |
Sent To |
B |
|
| Notes |
| 2004-11-02 00:00:00 | TO SH DESK/2 TRUSS DRAWS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2004-10-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-29 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-29 |
Time |
15:45 |
Sent To |
B |
|
| Notes |
| 2004-10-29 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2004-10-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-29 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-29 |
Time |
15:28 |
Sent To |
B |
|
| Notes |
| 2004-10-29 00:00:00 | TO SH DESK/3 SUBMITTALS | | | CONCRETE MIX ALTERNATE SUPPLIER | | | ELEVATION CERTIFICATE | | | FORUM BOARDS SURVEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
| 2004-10-25 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
16:45 |
Sent To |
B |
|
| Notes |
| 2004-10-20 00:00:00 | TO SH DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-18 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-18 |
Time |
15:21 |
Sent To |
B |
|
| Notes |
| 2004-10-18 00:00:00 | TO SH DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-12 |
Time |
16:37 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-12 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-12 |
Time |
16:06 |
Sent To |
B |
|
| Notes |
| 2004-10-12 00:00:00 | TO SH DESK/SUBMITTAL/ELEVATION CERT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-07 |
Time |
16:17 |
Sent To |
B |
|
| Notes |
| 2004-10-07 00:00:00 | TO SH DESK/2 SUBMITTALS | | | CONCRETE SUBMITTAL | | | SOIL BEARING & TESTS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-07 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
| 2004-10-07 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
10:56 |
Sent To |
B |
|
| Notes |
| 2004-10-05 00:00:00 | TO SH DESK/SUBMITTAL | | | ROOF TRUSS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
10:55 |
Sent To |
B |
|
| Notes |
| 2004-10-05 00:00:00 | TO SH DESK/SUBMITTAL | | | FIRESTOPPING SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2004-10-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-04 |
Time |
11:00 |
Sent To |
B |
|
| Notes |
| 2004-10-04 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2004-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-23 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-23 |
Time |
10:22 |
Sent To |
B |
|
| Notes |
| 2004-09-23 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-14 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-14 |
Time |
14:09 |
Sent To |
B |
|
| Notes |
| 2004-09-14 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-14 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-14 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
| 2004-09-14 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-26 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2004-07-26 00:00:00 | TO COMM BD#44 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-08 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-08 |
Time |
11:54 |
Sent To |
B |
|
| Notes |
| 2004-07-08 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-12 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2004-05-12 00:00:00 | TO COMM BD#5/BOX ON SHELF |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-05-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-06 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-06 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2004-05-06 00:00:00 | TO COMM BD#10 | | | PER SH NEW SHEETS FOR B,E,M, Z INCL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-04 |
Time |
15:19 |
Sent To |
B |
|
| Notes |
| 2004-05-04 00:00:00 | TO SH/BOX W/ROLLS ON SHELF |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-16 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-16 |
Time |
16:18 |
Sent To |
B |
|
| Notes |
| 2004-04-16 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-08 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2004-04-08 00:00:00 | TO COMM BD#19 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-20 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-20 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2004-02-20 00:00:00 | TO COMM BD#46/PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-12 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2003-12-12 00:00:00 | TO COMM BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
kmcvey |
Date |
2003-10-10 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2003-10-10 00:00:00 | TO COMM BD#59 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-24 |
Time |
11:16 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-01-24 |
Time |
11:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-01-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-01-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-12-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-31 |
Time |
06:38 |
Rev Time |
1.25 |
| Received By |
pkrauss |
Date |
2004-12-31 |
Time |
06:19 |
Sent To |
|
|
| Notes |
| 2004-12-31 00:00:00 | PROVISO: | | | 1.PLAN SHEET AP/M15.03 DETAIL OF THE | | | WALL HUNG UNIT.PER 2001 FBC(M)603.1.3, | | | 4" MINIMUM IS REQUIRED AROUND THE AHU. | | | | | | 2.PLAN SHEET AP/M15.01, PLAN DOES NOT | | | INDICATE RADIATION DAMPERS THAT ARE | | | REQUIRED DUE TO THE BUILDING TYPE.SEE | | | PLAN SHEET AP/15.03 FOR INSTALLATION | | | DETAIL FOR THE REQUIRED DAMPERS.THIS | | | IS REQUIRED AT EACH GRILLE. | | | | | | 3.PLAN SHEET CH/M15.01 IS NOT | | | APPROVED.FIRE DAMPERS ARE REQUIRED AT | | | THE DUCT PENETRATIONS THROUGH THE WALL | | | AT THE LAUNDRY ROOM.REFERENCE PLAN | | | SHEET AM/A1.04(REVISED 10/4/04), DETAIL | | | FOR THE WALL ASSEMBLY FOR THE "INTERIOR | | | RATED WALL @ CLUBHOUSE LAUNDRY" (W-3), | | | THIS REQUIRES FIRE DAMPERS FOR THE | | | PENTRATIONS. | | | | | | EXCEPTION TO FIRE DAMPERS ARE AS | | | FOLLOWS: | | | 1.DUCT SHALL NOT EXCEED 100 SQ | | | INCHES. | | | 2.THE DUCT SHALL BE OF .0217" MINIMUM | | | STEEL. | | | 3.DUCT SHALL CONTINUE A MINIMUM OF 5 | | | FT FROM RATED WALL ON HAVE NO OPENINGS | | | WITHIN 5 FT OF THE PENETRATION. | | | 4.DUCT SHALL BE INSTALLED ABOVE THE | | | CEILING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | E-MAIL:[email protected]. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-19 |
Time |
11:47 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-04-19 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2004-04-19 00:00:00 | PROVISO: | | | SEE COMMENTS FROM SAMANTHA HILL, | | | BUILDING PLAN REVIEW; ENERGY | | | CALCULATIONS ARE INCORRECT.PLEASE | | | REVISE & RESUBMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-09 |
Time |
06:39 |
Rev Time |
1.40 |
| Received By |
pkrauss |
Date |
2004-03-09 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | DENIED: | | | 1.REFERENCE RESPONSE LETTER DATED | | | 2-19-04; RESPONSE #1 - "REVISE AP/M15.01 | | | TO INCLUDE OUTSIDE AIR DUCTS TO AHU'S. | | | PLEASE INDICATE ON THE PLAN AN OUTSIDE | | | AIR SCHEDULE SHOWING COMPLIANCE WITH | | | TABLE 403.3. | | | | | | 2.RESPONSE #2 - "REFER TO DETAIL ON | | | AP/A15.01". DETAIL INDICATES A RATED | | | WALL AND NOT A VENTED SHAFT AS REQUIRED | | | IN ASHRAE 15-92 SECTIOIN 11.12.3 (A) | | | THROUGH (C). | | | | | | 3.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | PER CONVERSATION WITH GIL (ENGINEER), | | | WAITING STATE RULING ON WHICH ASHRAE | | | STANDARD WE ARE UNDER.CHAPTER 15 | | | INDICATES 15-94 & NOT 15-2001. | | | | | | COMMENT #3 WILL BE ADDRESSED/PLAN WILL | | | INDICATE A 4" CLEARANCE AROUND THE AHU. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-31 |
Time |
07:43 |
Rev Time |
1.50 |
| Received By |
pkrauss |
Date |
2003-12-31 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2003-12-31 00:00:00 | DENIED: | | | APARTMENTS | | | 1.PER 2001 FBC(M) 403.3, OCCUPANCY | | | TYPE R-2 (MULTI-FAMILY) REQUIRES | | | OUTSIDE AIR.ONLY ONE & TWO FAMILY | | | DWELLINGS (R-3) ARE EXEMPT FROM 403.3. | | | PLEASE REVISE AND SHOW COMPLIANCE WITH | | | TABLE 403.3. | | | | | | 2.PLEASE NOTE, REFRIGERANT LINES | | | INSTALLED VERTICALLY THROUGH FLOORS | | | SHALL COMPLY WITH ASHRAE 15-92 SECTION | | | 11.12.3 (A) THROUGH (C). | | | | | | CLUBHOUSE: | | | NO COMMENTS | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-17 |
Time |
12:41 |
Rev Time |
6.00 |
| Received By |
pkrauss |
Date |
2003-11-17 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2003-11-17 00:00:00 | DENIED: | | | APARTMENTS: | | | 1.PLEASE PROVIDE O.A. CALCULATIONS FOR | | | THE DWELLING UNITS AS PER 2001 FBC(M) | | | 403.3. | | | | | | 2.AUXILIARY DRAIN PAN REQUIRED WITH | | | OVERFLOW PROTECTION OR A SEPARATE DRAIN | | | LINE PER 2001 FBC(M) 307.2.3. | | | | | | 3.PLEASE NOTE, RETURN AIR GRILLES TO | | | BE SIZED AS FOLLOWS - 50 SQ IN (OF | | | GRILLE AREA) TO 100 CFM OF SUPPLY AIR | | | WHEN SIZING THROUGH THE WALL TRANSFER | | | GRILLES. 2001 FBC(M) 601.4 EXCEPTION #2. | | | | | | 4.PLAN SHEET 15.01 NOTE #12, SEE DRYER | | | DUCT ROUTING AND CONNECTION ON THE ARCH | | | PLANS.PLEASE INDICATE ARCH PLAN SHEET | | | FOR QUICK REFERENCE. PLAN SHEET AP A1.06 | | | SHOWS A DETAIL & AP A7.01 SHOWS THE | | | TERMINATION AT OUTSIDE WALL WITH CAP. | | | PLEASE NOTE IF SPECIFIC DRYERS ARE TO | | | BE INSTALLED FOR THE CAPABILITY OF | | | LONGER DUCT RUNOUTS, PROVIDE SUBMITTAL | | | ON DRYER & DRYERS MUST BE INSTALLED | | | PRIOR TO FINAL INSPECTION. | | | | | | CLUBHOUSE: | | | 1. AS PER 2001 FBC(M) 601.4 EXCEPTION | | | #1 TRANSFER DUCTS SHALL BE SIZED 1 1/2 | | | TIMES THE CROSS SECTIONAL AREA (SQ IN) | | | OF THE SUPPLY ENETERING THE ROOM OR | | | SPACE.SEE ATTACHED. | | | | | | 2.PLAN SHEET CH M15.01 INDICATES R/A | | | GRILLES AS "E".PLAN SHEET CH M15.02 | | | GRILLE & DIFFUSER SCHEDULE INDICATES | | | RETURNS AS "B".PLEASE CLARIFY | | | | | | 3.PLAN SHEET CH M-15.01 INDICATES A | | | TRANSFER DUCT FROM THE LAUNDRY ROOM TO | | | THE CLUBROOM.ROOMS THAT EMIT HEAT OR | | | EQUIPMENT OR PROCESSES THAT PRODUCE OR | | | THROW OFF DUST OR PARTICLES LIGHT ENOUGH | | | TO FLOAT IN THE AIR SHALL NOT BE RE- | | | CICULATED. 2001 FBC(M) 401.7 & 502.1. | | | | | | 4.DRYER INSTALLATIONS EXHAUSTING MORE | | | THAN 200 CFM SHALL BE PROVIDED WITH MAKE | | | UP AIR. 2001 FBC(M) 504.5. | | | | | | MAINTENANCE BUILDING: | | | 1.PLEASE INDICATE WHAT TYPE MAITENANCE | | | WILL BE DONE IN THIS AREA.WORKING ON | | | VECHICLES, MACHINES (COMBUSTION ENGINES) | | | LAWN EQUIPMENT? | | | | | | 2.PROVIDE OUTSIDE AIR CALCULATIONS. | | | | | | 3.INDICATE IF THE OFFICE IN THE | | | MAINTENANCE BUILDING WILL BE OCCUPIED | | | FULL TIME PART TIME?PLEASE CLARIFY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-14 |
Time |
08:50 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-05-14 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | PASSED/PROVISO | | | REVISION REQUIRED FOR SHEET CH/P14.02 | | | | | | 1) SHT CH/P14.02 WATER HAMMER ARRESTORS | | | SHALL BE LOCATED NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS | | | SHOWN. PDI-WH 201 AND MANUF. INSTALLAT- | | | ION INSTRUCTIONS. WATER HAMMER ARRESTOR | | | REQUIRED AT EACH WASH MACHINE. | | | | | | 2) INDICATE ON PLANS THAT AN RPZ BACK- | | | FLOW IS REQUIRED ON THE WATER SERVICE TO | | | THE CLUBHOUSE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-05 |
Time |
15:47 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-05 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-24 |
Time |
09:57 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-12-22 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2003-12-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | | | | 1) SPECIFICATION "A" OR"B" SHALL BE IN- | | | DICATED ON PLANS PER REQUIREMENT 7B OF | | | THE FHA DESIGN MANUAL. - RESPONSE NOTED, | | | BUT NOT REVISED SHEET AP/A5.04 FOUND. | | | 2) SHTS AP/P14.02 & AP/P14.04 CLEANOUTS | | | SHALL BE LOCATED IN THE BREEZEWAYS IN | | | ORDER TO COMPLY WITH SECTION 708.3.2 | | | LOCATED NOT MORE THAN 100' APART. 2 WAY | | | CLEANOUT WILL WORK. | | | 3) SHT AP/P1404 THE DISCHARGE PIPE SHALL | | | NOT HAVE ANY TRAPPED SECTIONS AND SHALL | | | HAVE A VISIBLE AIR GAP OR AIR GAP FITT- | | | ING LOCATED IN THE SAME ROOM AS THE | | | WATER HEATER. RESPONSE STATES T & P TO | | | DISCHARGE INTO DRAIN PAN BUT RELIEF | | | VALVE PIPING DIAGRAM STILL SHOWS T&P | | | PIPED UNDER SLAB. PLEASE CLAIRFY. SEC. | | | 504.7.1 | | | 4) AN RPZ BACKFLOW IS REQUIRED FOR EACH | | | BUILDING. RESPONSE NOTED, BUT SHOW ON | | | PLANS AS TYPICAL FOR EACH BLDG ON THE | | | INLET OF BLDG. FOR REFERENCE. | | | 5) SHT AP/P14.01 WATER RISER DIAGRAMS, | | | THE WATER HAMMER ARRESTORS ARE STILL | | | SHOWN IN CEILING. SHOW WATER HAMMER | | | ARRESTORS NEAR THE FIXTURES AS REQUIRED | | | BY PDI-WH 201 AND MANUF. INSTALL. INSTR. | | | 6) SEE ATTACHED SHEET CONCERNING FS | | | 533.80(2)(B) DESIGN PROFESSIONAL DOC- | | | UMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-03 |
Time |
17:11 |
Rev Time |
4.50 |
| Received By |
kstevens |
Date |
2003-11-03 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | | | | 1) SPECIFICATION "A" OR "B" SHALL BE IN- | | | DICATED ON PLANS PER REQUIREMENT 7B OF | | | THE FHA DESIGN MANUAL. | | | 2) SHT AP/P14.002 CLEANOUTS REQUIRED IN | | | BLDG DRAIN PER SECTIONS 708.3.1, 708.3.3 | | | 3) SHT AP/P14.04 SANT. RISERS 3S/P14.5, | | | AND3SA/P14.5 TUBS NOT VENTED. 901.2 | | | 4) SHT AP/P14.04 THE DISCHARGE PIPE | | | SHALL NOT HAVE ANY TRAPPED SECTIONS AND | | | SHALL HAVE A VISIBLE AIR GAP OR AIR GAP | | | FITTING LOCATED IN THE SAME ROOM AS THE | | | WATER HEATER. | | | 5) SHT AP/P14.04 WATER HEATER PIPING DE- | | | TAIL, DIELECTRIC UNIONS NOT APPROVED FOR | | | WATER PIPING. DELETE REFERENCE. | | | 6) AN RPZ BACKFLOW IS REQUIRED FOR EACH | | | BLDG. SECTION 608.13.2 | | | 7) SUBMIT A SANITARY ISOMETRIC BUILDING | | | DRAIN. SHOW ALL PIPE SIZES AND SHOW ALL | | | DFU'S AS THEY ACCUMULATE IN THE SYSTEM. | | | SHOW C/O'S REQUIRED IN COMMENT #2. SEC | | | 104.3.1.1 | | | 8) SHT AP/P14.05 WATER HEATER DETAIL. | | | THERMAL EXPANSION CONTROL REQUIRED. IF | | | 530 VALVE IS USED FOR THIS PURPOSE, THE | | | DRAINAGE LINE SHALL NOT BE CONNECTED TO | | | THE PRESSURE/TEMP. RELIEF DISCHARGE LINE | | | - ALSO EMERGENCY PAN SIZE SHALL COMPLY | | | WITH SECTION 504.8.1. | | | 9) SUBMIT A WATER RISER DIAGRAM SHOWING | | | HORIZONTAL PIPING WITH PIPE SIZES AND | | | PIPING FOR TYPICAL UNITS SHOWING PIPE | | | SIZES AND WATER HAMMER ARRESTORS REQUIR- | | | ED BY SECTION 604.9. LOCATION OF WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | | THE FIXTURES IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INST. INSTRUCT. | | | 10) FULL OPEN VALVES RQURED ON THE BASE | | | OF EVERY WATER RISER PER SEC. 606.1(3), | | | AND ON TOP OF EVERY WATER DOWN FEED PIPE | | | PER SEC. 606.1(4). ACCESS WILL BE PRO- | | | VIDED PER SEC. 606.3. PROVIDE DETAIL. | | | 11) SHTS CH/P14.01 & CH/P14.02 CLEANOUTS | | | ARE REQUIRED NEAR THE BUILDING DRAIN AND | | | BUILDING SEWER JUNCTION AND MAY BE TWO | | | WAY TO CLEAN OUT BOTH BLDG. DRAIN AND | | | BLDG. SEWER. SEC. 708.3.5 | | | 12) SHT CH/P14.02 WATER RISER DIAGRAM. | | | WATER HAMMERS SHALL BE LOCATED PER PDI- | | | WH 201 AND MANUF. INSTALL. INSTRUCTIONS. | | | 13) AN RPZ BACKFLOW IS REQUIRED FOR | | | CLUBHOUSE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-10 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-05-10 00:00:00 | OK PER JOYCE, SEE PERMITS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-11-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-11-25 |
Time |
10:11 |
Sent To |
PC |
|
| Notes |
| 2003-11-25 00:00:00 | 11/25/03 GRACE OK MM |
|
|