Plan Review Details - Permit 03100621
Plan Review Stops For Permit 03100621
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2004-01-23 Cont ID  
Sent By lmartine Date 2004-01-23 Time 12:31 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2004-01-23 00:00:00ENTRY DOOR SUBMITTALOKLM

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-01-08 Cont ID  
Sent By csiegber Date 2004-01-23 Time 07:40 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2004-01-08 00:00:00APPROVED HARDYBOARD REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-12-22 Cont ID  
Sent By csiegber Date 2004-01-06 Time 13:49 Rev Time 3.00
Received By lmartine Date   Time   Sent To  
Notes
2003-12-22 00:00:00 
 BUILDING REVISION COMMENTS
 --------------------------
  
  
 REVISION APPROVED :
  
 ALL STRUCTURAL WORK IS APPROVED EXCEPT
 FOR THE MODIFICATION OF THE FRONT ENTRY
 DOORS AND SIDELIGHTS.
  
  
  
  
 L. MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-12-11 Cont ID  
Sent By lmartine Date 2003-12-11 Time 13:52 Rev Time 3.00
Received By lmartine Date   Time   Sent To  
Notes
2003-12-11 00:00:00 
 BUILDING REVISION COMMENTS
 --------------------------
  
  
 REVISIONS AS SUBMITTED ARE DENIED.
 CHANGES SHOWN EXCEED THE STATES LIMITATI
 ONS FOR REVISIONS TO STATE APPROVED MODU
 LAR BUILDIGS.
  
 SEE RULES ATTACHED 9B-1.011
  
  
  
  
  
 L. MARTINEZ
 561-805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-30 Cont ID  
Sent By hpiskura Date 2003-10-30 Time 08:29 Rev Time 0.00
Received By hpiskura Date 2003-10-30 Time 08:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-22 Cont ID  
Sent By hpiskura Date 2003-10-22 Time 11:13 Rev Time 0.00
Received By hpiskura Date 2003-10-22 Time 11:12 Sent To  
Notes
2003-10-22 00:00:00FBC 1804.1.3 REQUIRES THE BOTTOM OF
 FOUNDATIONS TO BE AT LEAST 12" BELOW
 GRADE. SHEET 4 OF 4 OF THE RESUN
 LEASING/BODZIAK PLANS SHOWS THE PIERS
 ON TOP OF GRADE. PLEASE REVISE AS
 NECESSARY.
  
 ALSO, SHOW THE TOPOGRAPHY TO PROVIDE
 THESLOPING DRAINAGE IN ACCORDANCE WITH
 FBC 1804.1.7.
  
 SHOW THE METHOD OF TERMITE PROTECTION
 AS REQUIRED BY FBC 1816.
  
 SHEETS 1 AND 2 OF 6 ARE MISSING FROM
 THEEDUARDO VAZQUEZ, PE PLANS.
  
 SHEET 3 OF 6 OF THE VAZQUEZ PLANS SHOWS
 STRUCTURAL ALTERATIONS TO THE EXTERIOR
 WALLS OF THE BUILDING THAT WILL
 INVALIDATE THE DCA INSIGNIA AND MANDATE
 COMPLIANCE WITH THE CURRENT FBC.
  
 GIVEN THE ABOVE, PROVIDE DETAILS FOR
 THEINSTALLATION OF THE NEW DOORS AND
 WINDOWS, HURRICANE MISSLE IMPACT
 PROTECTION, AND TEST AND NOTICE OF
 ACCEPTANCE REPORTS.PROVIDE STRUCTURAL
 CALCULATIONS DEMONSTRATINGCOMPLIANCE
 WITH THE FBC FOR A 140 MPH WIND REGION.
  
 PROVIDE DETAILS FOR THE PLUMBING AND
 ELECTRICAL FOR THE NEW KITCHENETTE AREA
 AND THE ADDED PARTITIONS.
  
 THE FOLLOWING REGARDS THE PROPOSED
 PATIO, RAMP AND STAIR CONSTRUCTION.
  
 PLEASE PROVIDE STRUCTURAL CALCULATIONS
 FOR THE 2X2 GUARD RAIL AND 3/4" PICKETS
 SHOWN IN SECTIONS 4/P4 AND 5/P4.SEE
 FBC 1608.2 FOR MINIMUM DESIGN LOADS.
  
 SHOW THE STAIR TREAD AND RISER
 DIMENSIONS. SEE FBC 1007.2 AND 1007.3.
  
 HANDRAILS ARE REQUIRED ON BOTH SIDES OF
 STAIRS, EAST ELEVATION, FBC 1007.5.2
 ANDWITHIN 30" OF EGRESS STAIR WIDTH,
 1007. 5.7.PLEASE REVISE AS NECESSARY.
  
 SHEET 5 OF 6.PLEASE PROVIDE THE FIRE
 SPRINKLER DESIGN INFORMATION AS
 PROVIDED FOR IN NFPA 13-99 CHAPTER 8;
 AND CHAPTER 61G15-32 OF THE FL
 ADMINISTRATIVE CODE.
  
 THE DECLARED PERMIT VALUATION OF
 $20,000.00 IS TOO LOW FOR THE SCOPE OF
 WORK DECLARED ON SHEET 3 OF 6 OF THE
 VAZQUEZ PLANS.PLEASE PROVIDE A SIGNED
 CONTRACT(S) ANDDETAILED TAKEOFFS,
 INCLUDING EXTENSIONS, TO ESTABLISH THE
 ACTUAL COSTS OF THE WORK FOR THIS
 PERMIT.

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2003-12-22 Cont ID  
Sent By lmartine Date 2003-12-22 Time 17:18 Rev Time 1.00
Received By lmartine Date 2003-12-19 Time 08:06 Sent To  
Notes
2003-12-22 00:00:00ELECTRIC APPROVED UNDER SEPERATE PERMIT

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-12-08 Cont ID  
Sent By dpalmer Date 2003-12-08 Time 12:05 Rev Time 1.00
Received By dpalmer Date 2003-12-08 Time 12:05 Sent To  
Notes
2003-12-08 00:00:00*************** UNSAT ***************
  
 1)NOTE: PLEASE SUBMIT ALL ELECTRICAL
 REVISIONS UNDER ELECTRICAL PERMIT AS
 REVIEW WAS NOT DONE UNDER THIS PERMIT
 AS PER REQUEST BY OWNER/ARCH.
  
 2)NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FROM MAIN TO SUB
 PANELS. 250.110/250.122/250.24
  
 3)NOTE: PLEASE SEE FIRE REVIEW COMMENTS
 AND PLEASE SHOW ALL EM/EXT LTS PER
 700.12E
  
 4)NOTE: PLEASE SIZE GEC PER 250.66.
  
 5)NOTE: PLEASE SEE FS 471.025 AND FAC
 61G15-23.002. PLANS ARE REQ'D TO HAVE
 A COMPLETE SIGNATURE BY ENG OF RECORD.
 INITIALS ARE NOT ACCEPTABLE PER THE
 ABOVE AND DIRECTION FROM FL BOARD OF PE.
 'S.
  
 6)NOTE: PLEASE SUBMIT AIC RATING FOR ALL
 NEW EQUIPMENT BEING INSTALL. MAINS/ BRKR
 'S/ AND PANELS ARE ALL TO BE RATED FOR
 THE AVAILABLE FAULT CURRENT. 110.9/215.5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REIVEW 561-805-6717
 [email protected]
 561-805-6717

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2003-10-16 Cont ID  
Sent By dpalmer Date 2003-10-16 Time 10:40 Rev Time 0.50
Received By dpalmer Date 2003-10-16 Time 10:40 Sent To  
Notes
2003-10-16 00:00:00******** NOTE *********
  
  
 SEPARATE PLAN/RISER DIAGRAM TO BE
 SUBMITTED WITH APPLICATION FROM ELEC-
 -TRICAL CONTRACTOR.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-10-15 Cont ID  
Sent By dpalmer Date 2003-10-15 Time 17:48 Rev Time 0.33
Received By dpalmer Date 2003-10-15 Time 17:48 Sent To  
Notes
2003-10-15 00:00:00********** UNSAT *************
  
 1)NOTE: PLEASE SUBMIT AN ELECTRICAL
 RISER DIAGRAM FOR ELECTRICAL HOOK UP
 OF ENTIRE SYSTEM.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2003-10-16 Cont ID  
Sent By mamini Date 2003-10-16 Time 11:02 Rev Time 0.00
Received By mamini Date 2003-10-16 Time 11:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-12-11 Cont ID  
Sent By mcarsill Date 2003-12-11 Time 14:16 Rev Time 0.00
Received By mcarsill Date 2003-12-11 Time 14:16 Sent To  
Notes
2003-12-11 00:00:001) ENSURE THAT EXIT SIGNS AND EMERGENCY
 LIGHTS ARE INSTALLED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-10-29 Cont ID  
Sent By nmccray Date 2003-10-29 Time 14:42 Rev Time 0.00
Received By nmccray Date 2003-10-29 Time 14:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-10-17 Cont ID  
Sent By mcarsill Date 2003-10-17 Time 17:35 Rev Time 0.00
Received By mcarsill Date 2003-10-17 Time 17:35 Sent To  
Notes
2003-10-17 00:00:001) FIRE PROTECTION BACKFLOW DEVICE
 IS REQUIRED TO BE EQUIPPED WITH
 TAMPER SWITCHES, CHAIN AND LOCK.
  
 2) FIRE HYDRANT DETAIL SHOWS BOLLARD
 BEHIND FIRE HYDRANT. NO ITEMS ALLOWED
 WITHIN 4 FEET TO THE REAR OF FIRE
 HYDRANT. NEW FIRE HYDRANT SHALL MEET
 FIRE RESCUE AND UTILITY STANDARDS.
 PLEASE OBTAIN CITY DETAILS.
  
 3) ALL FIRE SPRINKLER SYSTEMS ARE
 REQUIRED TO BE MONITORED BY UL LISTED
 FOR CENTRAL STATION SERVICE.
  
 4) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER SYSTEM.
  
 5) NO ILLUMINATED EXIT SIGNS OR
 EMERGENCY LIGHTS SHOWN ON PLANS.
  
 6) MODULAR UNIT LOCATED IN FIRE LIMITS.
 SEE CBAA CASE # 1247.
  
 7) BUILDING ADDRESS REQUIRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-01-23 Cont ID  
Sent By csiegber Date 2004-01-23 Time 07:40 Rev Time 0.00
Received By csiegber Date 2004-01-23 Time 07:40 Sent To B
Notes
2004-01-23 00:00:00TO LM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-01-06 Cont ID  
Sent By csiegber Date 2004-01-06 Time 13:48 Rev Time 0.00
Received By csiegber Date 2004-01-06 Time 13:48 Sent To B
Notes
2004-01-06 00:00:00TO
 TO LM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-12-02 Cont ID  
Sent By csiegber Date 2003-12-01 Time 16:53 Rev Time 0.00
Received By csiegber Date 2003-12-02 Time 16:52 Sent To  
Notes
2003-12-01 00:00:00TO COMM BD#4

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-29 Cont ID  
Sent By csiegber Date 2003-10-29 Time 10:01 Rev Time 0.00
Received By csiegber Date 2003-10-29 Time 09:58 Sent To  
Notes
2003-10-29 00:00:00TO COMM BD#13

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-15 Cont ID  
Sent By csiegber Date 2003-10-15 Time 08:27 Rev Time 0.00
Received By csiegber Date 2003-10-15 Time 08:27 Sent To  
Notes
2003-10-15 00:00:00TO COMM BD#

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-10 Cont ID  
Sent By mmclean Date 2003-10-14 Time 16:54 Rev Time 0.00
Received By csiegber Date 2003-10-10 Time 11:19 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-10-16 Cont ID  
Sent By pkrauss Date 2003-10-16 Time 11:27 Rev Time 0.20
Received By pkrauss Date 2003-10-16 Time 11:27 Sent To  
Notes
2003-10-16 00:00:00 
 SALES TRAILERS/(3) 3.0 TON WALL HUNG
 HVAC UNIT.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-10-16 Cont ID  
Sent By kstevens Date 2003-10-16 Time 12:20 Rev Time 0.50
Received By kstevens Date 2003-10-16 Time 12:20 Sent To  
Notes
2003-10-16 00:00:00PASSED/PROVISO
  
 RPZ BACKFLOW SHALL BE CONNECTED DOWN-
 STREAM OF THE WATER METER

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-10-10 Time 11:19 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
2003-10-14 00:00:0010/14/03 OK PER ANTHA LITTLES & ANA
 MARIE PROVISO: PARKING ON FERN STREET
 MUST BE SETBACK 20' SHIFT PARKING 10'
 NORTH MM