Plan Review Details - Permit 03100590
| Plan Review Stops For Permit 03100590 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-14 |
Time |
13:32 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-14 |
Time |
13:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-14 |
Time |
13:12 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-14 |
Time |
19:25 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-14 |
Time |
19:25 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | ************ UNSAT ****************** | | | | | | 1)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | | AND CORRELATE WITH SUBMITTED PANEL | | | SCHEDULE. UNABLE TO VERIFY AT THIS TIME | | | IF CIRCUITS ARE SEPARATED FOR SUITES AS | | | REQ'D. 215.5 | | | | | | 2)NOTE: PLEASE SEE THAT EM/EXT LTS | | | APPEAR TO COMING FROM ONE PANEL ONLY? | | | PLEASE CIRCUIT EM/EXT LTS OER 700.12E | | | | | | 3)NOTE: PLEASE SHOW TRK LOADS PER 220.12 | | | B. | | | | | | 4)NOTE: PLEASE CLARIFY NOTE ON PANEL | | | SCHEDULE. NOTE MENTIONS, RELOCATE LTS TO | | | NEW TRANSFORMER LOCATIONS? PLEASE SEE | | | THAT THERE IS NOTHING SHOWN ON PLANS FOR | | | THIS?? | | | | | | PLEASE SEE NOTES FROM OTHER REVIEWERS | | | THAT MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-10-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-30 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-30 |
Time |
06:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-11-14 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2003-10-10 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2003-10-10 00:00:00 | TO COMM BD#1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-10-29 |
Time |
19:29 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-10-29 |
Time |
19:29 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | NO MECHANICAL PLANS.NO SIGNATURE FOR | | | MECHANICAL ON BACK OF THE PERMIT | | | APPLICATION. | | | PLAN REVIEW BY HAROLD MOSER |
|
|
|
Account Summary | Usage Policy | Privacy Policy