| Plan Review Stops For Permit 03100570 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-06-21 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-06-21 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2004-06-21 00:00:00 | REVISION SUBMITTED 6/3/04 FOR SHEETS | | | A-1, A-4, A-6 AND A-7. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-03-16 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-03-16 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2004-03-16 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | SEPARATE PERMIT APPLICATION IS REQUIRED | | | FOR DOORS AND WINDOWS (EXCEPT THE | | | ROLL-UP DOORS FOR WHICH VALID PRODUCT | | | APPROVAL HAS ALREADY BEEN SUBMITTED). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-02-02 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-01-30 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2004-01-30 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 12/19/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | THE RESPONSE LETTER DATED 1/15/04 IS | | | FROM R.C.T. ENGINEERING.THE COMMENT IS | | | ABOUT THE ARCHITECTURAL PLANS SEALED BY | | | THE ARCHITECT AND SHOULD HAVE BEEN | | | ADDRESSED BY STEPHEN BORUFF, ARCHITECT'S | | | AND PLANNERS INC.THE LICENSE NUMBER | | | PRINTED ON SHEETS A-1 THROUGH A-11 IS | | | THAT OF THE ARCHITECTURAL BUSINESS ONLY. | | | PLANS PREPARED BY A REGISTERED ARCHITECT | | | SHALL INCLUDE THE PRINTED NAME AND | | | LICENSE NUMBER OF THE ARCHITECT SEALING | | | THE PLANS, NOT JUST THE ARCHITECTURAL | | | BUSINESS.FOR YOUR REFERENCE THE | | | FOLLOWING IS A SUMMARY EXTRACT FROM THE | | | FLORIDA ADMINISTRATIVE CODE: | | | 61G1-16.004FL. ADMIN. CODE. - PLANS | | | PREPARED BY A REGISTERED ARCHITECT | | | SHALL INCLUDE A TITLE BLOCK WHICH MUST: | | | - STATE THE FIRM NAME, ADDRESS AND | | | TELEPHONE NUMBER | | | - STATE THE FIRM LICENSE NUMBER | | | - STATE PROJECT NAME OR IDENTIFICATION | | | - STATE DATE PREPARED | | | - INCLUDE AN ORIGINAL SIGNATURE AND | | | DATED SEAL | | | - INCLUDE THE PRINTED NAME OF THE | | | ARCHITECT SEALING THE PLANS | | | ADD THE PRINTED NAME AND LICENSE NUMBER | | | OF THE ARCHITECT ON SHEETS A-1 THRU A-11 | | | | | | 8) PRODUCT APPROVALS. | | | (A) WALL/ROOF PANELS, A VALID PRODUCT | | | APPROVAL OR SITE SPECIFIC ENGINEERING IS | | | REQUIRED FOR THE PANEL SYSTEM BEFORE A | | | PERMIT IS ISSUED. | | | (B) WINDOWS AND DOORS, SUBMITTAL OF A | | | PRODUCT APPROVAL FOR ROLL-UP DOORS IS | | | ACKNOWLEDGED BUT NO VALID PRODUCT | | | APPROVAL HAS BEEN SUBMITTED FOR THE | | | WINDOWS AND EXTERIOR DOORS.SEPARATE | | | PERMIT APPLICATIONS WILL BE REQUIRED. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-19 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-18 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2003-12-19 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) 61G1-16.004FL. ADMIN. CODE.PLANS | | | PREPARED BY A REGISTERED ARCHITECT SHALL | | | INCLUDE THE PRINTED NAME OF THE | | | ARCHITECT SEALING THE PLANS. | | | | | | 2) FBC 1005.7.1EGRESS FROM THE | | | MEZZANINE.THE TRAVEL DISTANCE FROM THE | | | MOST REMOTE POINT ON THE MEZZANINE TO | | | THE CLOSEST BUILDING EXIT EXCEEDS 75 FT | | | (FBC TABLE 1005.7) SO TWO MEANS OF | | | EGRESS ARE REQUIRED FROM THE MEZZANINE. | | | AMEND THE PLANS. | | | | | | 3) FBC 704.1.4MATERIALS STORAGE ROOM. | | | ANNOTATE SHEET A-1 TO SPECIFY THE | | | REQUIRED 2-HOUR FIRE-RATED WALLS AND | | | CEILING/ROOF TO THIS ROOM. | | | | | | 4) FBC 705.1.3SHEET A-7, DETAIL 10. | | | FIRE DOOR JAMB.WHERE DOES THIS DETAIL | | | APPLY?IT SPECIFIES A 1-HOUR FIRE-RATED | | | DOOR FRAME AND 45-MINUTE FIRE-RATED DOOR | | | WHICH DO NOT CORRELATE WITH ANY DOOR ON | | | THE DOOR SCHEDULE. | | | | | | 5) FBC 1608.2SHEET S-3 AND S-5.AMEND | | | THE PLANS TO SPECIFY THE CODE | | | REQUIREMENT FOR THE HANDRAILS AND | | | GUARDRAIL TO SUPPORT A 200LB | | | CONCENTRATED LOAD AND 50 PLF LINE LOAD | | | (APPLIED AS PER THE CODE) ACTING IN ANY | | | DIRECTION. | | | | | | 6) FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL. | | | | | | 7) A SEPARATE PERMIT APPLICATION WILL BE | | | REQUIRED FOR THE AWNINGS. | | | | | | 8) SUBMIT PRODUCT APPROVALS FOR THE | | | WINDOWS, EXTERIOR DOORS, ROLL-UP DOORS | | | AND WALL/ROOF PANELS. | | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | | PRODUCT APPROVAL NUMBER (FL###), | | | AVAILABLE FROM THE DEPT OF COMMUNITY | | | AFFAIRS PRODUCT APPROVAL WEBSITE | | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | | | 9) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-15 |
Time |
14:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-06-15 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | *** NOTES REDLINED **** | | | | | | SOME SORT OF LIGHTNING PROTECTION SHOWN | | | ON PLANS. | | | THIS IS NOT PART OF THIS PERMIT AND MUST | | | BE SUBMITTED UNDER SEPARATE PERMIT APPL. | | | | | | ALL LIGHTNING PROTECTION SYSTEMS TO BE | | | SUBMITTED UNDER SEPARATE PERMIT AND | | | MUST MEET NFPA-780 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-26 |
Time |
11:23 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-01-26 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | NOT ENOUGH INFORMATION ON LIGHTNING | | | PROTECTION, UNDER SEPARATE PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-15 |
Time |
19:36 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-10-15 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2003-10-16 00:00:00 | ************* UNSAT ****************** | | | | | | 1)NOTE: PLEASE CORRELATE PLANS AND | | | RISER/PANEL DIAGRAM. PLANS SHOW CIRCUITS | | | FOR A PANEL "H". PLEASE SEE RISER, SHOWS | | | WHAT APPEARS TO BE A PANEL "M"? | | | PLEASE CORRELATE. | | | | | | 2)NOTE: PLEASE CLARIFY LOCATION OF PANEL | | | "LA" AND PANEL "H/M" ON PLANS. PANEL LB | | | WAS LOCATED. | | | | | | 3)NOTE: PLEASE SEE 61G15-23.002 FOR ALL | | | REQ'D LICENSE INFORMATION ON TITLE BLOCK | | | FAC,FS 471. | | | THIS WOULD INCLUDE CA#'S. | | | PLEASE SEE THAT THIS REQ'D ON ALL SHEETS | | | FOR ALL TRADES EVEN A COMMENT IS NOT | | | MADE BY ADDTIONAL PLAN REVIEWERS. | | | | | | PLEASE SEE OTHER REVIEWERS COMMENTS,AS | | | THEY MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS FOR REVIEW AND STAMP- | | | -ING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | PLEASE SEE THAT WE ARE NOW UNDER THE | | | 2002 NEC AS OF 7/1/03 | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2003-10-15 00:00:00 | REVIEW IN PROGRESS, NOTES TO FOLLOW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-10-21 |
Time |
09:45 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-10-21 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2003-10-21 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03090886 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 895-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-06-21 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-06-21 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2004-06-21 00:00:00 | REVISION O.K. PER M. CARSILLO.SIGNED | | | OFF 6/4/04 ON RESUBMITTAL SHEET. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-22 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-22 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-31 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-31 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2003-10-31 00:00:00 | 1) A HAZARDOUS MATERIALS KNOX-BOX | | | WILL BE REQUIRED. PLEASE SEE CITY | | | ORDINANCE 3206-99 FOR FURTHER DETAILS. | | | | | | 2) EXIT SIGN SYMBOL APPEARS IN THE | | | WRONG LOCATION FOR EXTERIOR DOOR OF | | | LAB 116. | | | | | | 3) PLEASE EXPLAIN PURPOSE OF HOLD-OPEN | | | DEVICES ON DOUBLE DOORS FOR MATERIALS | | | STORAGE ROOM 118. SHOULD THESE DOORS | | | REMAIN CLOSED DUE TO THE MATERIALS | | | BEING STORED WITHIN IT. | | | | | | 4) NO EXIT SIGNAGE OR EMERGENCY LIGHTING | | | SHOWN FOR THE MEZZANINE. | | | | | | 5) WHAT WILL THE FUME HOOD BE USED FOR. | | | | | | 6) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | 7) NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. | | | | | | 8) BUILDING ADDRESS REQUIRED ON | | | PROPER ELEVATION. | | | | | | 9) PLEASE PROVIDE PRODUCT APPROVALS | | | FOR THE FIRE SHUTTERS ON PAGE A-6. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2004-06-03 00:00:00 | TO COMM BD#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-10 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-03-10 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-03-10 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2004-03-10 00:00:00 | TO RB DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-21 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-21 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2004-01-21 00:00:00 | TO COMM BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-14 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-10-14 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | TO COMM BD#39 | | 2003-10-10 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-03 |
Time |
07:25 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2004-02-03 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-14 |
Time |
07:21 |
Rev Time |
1.20 |
| Received By |
pkrauss |
Date |
2003-11-14 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2003-11-14 00:00:00 | DENIED: | | | 1.PLEASE NOTE PLAN SHEET AC-2 NOTE 6 | | | E REFERS TO PLAN SHEET FP-2. PLAN NOT | | | SUBMITTED. | | | | | | 2.PLEASE PROVIDE ELEVATION FOR THE | | | TERMINATION OF THE EXHAUST HOOD THROUGH | | | THE SIDE WALL.TERMINATION SHALL COMPLY | | | WITH 2001 FBC(M) 506.3.14.2 & 506.3.14.3 | | | | | | 3.PLANS DO NOT INCLUDE ANY INFORMATION | | | ON THE HOOD OR FIRE SUPPRESSION SYSTEM. | | | PLEASE PROVIDE MANUFACTURER SUBMITTAL | | | DATA AND ALL PERTINENT INFORMATION WITH | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-17 |
Time |
08:25 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-06-17 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | REVISION OK - ADDED A LAV IN TOILET ROOM | | | SHEETS P-1, P-2, P-3, P-4. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-16 |
Time |
09:53 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-03-16 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-02 |
Time |
18:41 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-02-02 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2004-02-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) FROM PREVIOUS REVIEW: AN RPZ BACKFLOW | | | IS REQUIRED ON THE WATER SERVICE FOR THE | | | BUILDING. SECTION 608.13.2. - COMMENT | | | RESPONSE NOTED, BUT A BACKFLOW IS STILL | | | REQUIRED FOR THIS BUILDING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-21 |
Time |
09:55 |
Rev Time |
1.50 |
| Received By |
mamini |
Date |
2003-10-21 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2003-10-21 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | | | | 1) G6G15-23.002(2) SEE ATTACHED SHEET | | | CONCERNING INFORMATION REQUIRED ON TITLE | | | BLOCK. | | | 2) SHT P-4 SANITARY RISER DIAGRAM, THE | | | TRAPS ON MANY FIXTURES SHOW "S" TRAPS. | | | TRAPS SHALL BE VENTED AS SHOWN BY RED | | | LINE CORRECTIONS. PLEASE SHOW PROPER | | | VENTS. 1002.3(5) | | | 3) WATER SERVICE TO BLDG SHALL HAVE | | | BACKFLOW PREVENTIONS. 608.13.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-14 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-10-14 00:00:00 | 10/14/03 PASS ZONING MM |
|
|