Plan Review Details - Permit 03100556
Plan Review Stops For Permit 03100556
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-11-14 Cont ID  
Sent By jwitmer Date 2003-11-14 Time 13:05 Rev Time 0.50
Received By jwitmer Date 2003-11-14 Time 13:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-30 Cont ID  
Sent By jwitmer Date 2003-10-30 Time 13:45 Rev Time 0.95
Received By jwitmer Date 2003-10-30 Time 13:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-21 Cont ID  
Sent By jwitmer Date 2003-10-21 Time 15:06 Rev Time 2.25
Received By jwitmer Date 2003-10-21 Time 15:06 Sent To PC
Notes
2003-10-21 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03100556
 ADD: 1500 CLARE AVE
 CONT: O/B IVANCEVIC, DANILO
 TEL: (561)493-1975
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1)TABLE 704.1 OCCUPANCY SEPERATION
 REQUIREMENTS; PLEASE INDICATE THE USAGE
 OF EACH AREA. WILL THE LARGER AREA BE US
 ED FOR INDUSTRIAL, FACTORY OR STORAGE?
 IF STORAGE WHAT TYPE OF MATERIALS WILL
 BE STORED THERE?
 2) STORAGE INDICATE (2) MEANS OF EGRESS,
 MUST BE SWING DOORS, NOT OVERHEAD DOORS?
 SEE 1027.1.1.
 3)1004.1.4 WHERE 2 OR MORE EXITS OR
 EXIT ACCESS DOORS ARE REQUIED, AT LEAST
 2 OF THE EXIT OR EXIT ACCESS DOORS SHALL
 BE PLACED A DISTANCE APART EQUAL TO NOT
 LESS THAN 1/2 OF THE LENGTH OF THE MAX-
 IMUM OVERALL DIAGONAL DIMENSION OF THE
 BUILDING OR AREA TO BE SERVED.
 4) DEPENDING ON THE TYPE OF STORAGE A
 OCCUPANCY SEPERATION WALL WILL BE RE-
 QUIRED. 1HR VS 2 HR WALL.TABLE 704.1.
 5) THE PROPOSED OFFICE EXSPANSION, IS
 STORAGE TO BE CONSIDERED ABOVE THIS NEW
 CEILING?
 6) FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 2405.2.1(3) GLAZING IN AN INDIVIDUAL FIX
 ED OR OPERABLE PANEL ADJACENT TO A DOOR
 WHERE THE NEAREST VERTICAL EDGE IS WITH-
 IN A 24" RADIUS OF THE DOOR IN A CLOSED
 POSITION.
 7) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY/ SPRINKLERED VS
 NONSPRINKLERED?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-11-07 Cont ID  
Sent By dpalmer Date 2003-11-07 Time 11:43 Rev Time 0.25
Received By dpalmer Date 2003-11-07 Time 11:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-10-31 Cont ID  
Sent By dpalmer Date 2003-10-31 Time 06:54 Rev Time 0.33
Received By dpalmer Date 2003-10-31 Time 06:54 Sent To  
Notes
2003-10-31 00:00:00********* UNSAT ***************
  
 1)NOTE: PLEASE SEE PLANS SUBMITTED,
 PLANS SHOW TOTAL OF FOUR ELECTRICAL
 PANELS, TWO 3-PHASE AND TWO SINGLE -
 PHASE. COPY OF PREVIOUS PERMIT/ELECTRI-
 -CAL RISER DOES NOT CORRELATE WITH PLANS
  
 2)NOTE:PLANS ARE NOW SHOWING MOST
 CIRCUITING HOWEVER NO PANEL SCHEDULE(S)
 WERE SUBMITTED TO CORRELATE?
 PLEASE ALSO SEE 700.12E FOR EM/EXT LTS
 CIRCUITING.
  
 3)NOTE: PLEASE SEE FIRE REVIEW COMMENTS
 FOR POSSIBLE EM LTS. PLEASE CLARIFY
 MIN LTS REQ'D PER LS 101 5-8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-10-14 Cont ID  
Sent By dpalmer Date 2003-10-14 Time 18:45 Rev Time 0.50
Received By dpalmer Date 2003-10-14 Time 18:45 Sent To  
Notes
2003-10-14 00:00:00*********** UNSAT *****************
  
 1)NOTE: PLEASE SEE 104.6.5, VALUE OF
 SCOPE OF WORK IS TO INCLUDE ALL LABOR
 PLUS MATERIALS. VALUED TO BE BASED ON
 WHAT MARKET VALUE BASED ON WHAT IT WOULD
 COST IF ALL WORK WAS TO BE PERFORMED
 BY LICENSED CONTRACTORS.
  
 2)NOTE: PLEASE PROVIDE ALL CIRCUITING ON
 PLANS AND CORRELATE WITH A SUBMITTED
 PANEL SCHEDULE.
  
 3)NOTE: PLEASE PROVIDE INFORMATION ON
 TYPE OF OCCUPANCY. MERC,BUS ETC.
 THERE MAY BE ADDITIONAL ELECTRICAL REQ'D
 DEPENDING ON OCCP.
  
 4)NOTE: PLEASE PROVIDE INFORMATION ON
 EXISTING PANEL/SERVICE ETC.215.5
  
 5)NOTE: PLEASE SHOW NEW OR EXISTING
 MIN LIGHTING REQ'D UNDER LS 101 5-8.
 PLEASE ALSO SHOW ALL NEW AND /OR EXIST-
 -ING EXIT/ EMERG LTS. CIRCUIT PER 700.12
 -E.
  
 6)NOTE: PLEASE SEE THAT PLANS MAY NOT
 BE SUBMITTED WRITTEN IN PENCIL.
 PLEASE SEE 104.2 FOR SPEC FOR PLANS.
  
 PLEASE SEE POSSIBLE COMMENTS FROM OTHER
 REVIEWERS THAT MAY HAVE AN AFFECT ON
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMAITON FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-10-31 Cont ID  
Sent By mcarsill Date 2003-10-31 Time 16:21 Rev Time 0.00
Received By mcarsill Date 2003-10-31 Time 16:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-10-21 Cont ID  
Sent By nmccray Date 2003-10-21 Time 12:24 Rev Time 0.00
Received By nmccray Date 2003-10-21 Time 12:24 Sent To  
Notes
2003-10-21 00:00:00DENIED*****************************
 1) WHAT TYPE OF OCCUPANY CLASSIFICATION
 INDUSTRIAL,BUSINESS, ETC.
  
 2) PLEASE SHOW ALL NEW AND OR EXISTING
 EXIT SIGNS AND EMERGENCY LIGHTS.
  
 3) PLEASE SHOW ALL EXIT DOORS.(TWO MEANS
 OF EGRESS ARE REQUIRED)
  
 4) WHAT IS THE INTERIOR FINISH FOR THE
 WALL AND CEILING. ( CLASS "A", CLASS "B"
 OR CLASS "C")
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-11-18 Cont ID  
Sent By sthyng Date 2003-11-18 Time 11:34 Rev Time 0.00
Received By sthyng Date 2003-10-09 Time 11:13 Sent To  
Notes
2003-11-06 00:00:00TO COMM BD#23
2003-10-27 00:00:00TO COMM BD#61
2003-10-09 00:00:00TO COMM BD#61