| Plan Review Stops For Permit 03100205 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-05 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-11-14 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2003-11-14 00:00:00 | PLANS TO BE TAKEN TO PALM BEACH COUNTY | | | AND IMPACT FEES PAID. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-13 |
Time |
17:31 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2003-10-20 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2003-10-20 00:00:00 | SEE NOTES FROM OTHER PLAN REVIEWERS. | | | BUILDING OKAY.WILL SIGN OFF WHEN OTHER | | | REVIEWS ARE PASSED. LS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-11-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-13 |
Time |
17:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-13 |
Time |
16:59 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-10-08 |
Time |
19:49 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-10-15 |
Time |
14:04 |
Sent To |
M |
|
| Notes |
| 2003-10-16 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THERE ARE SEVERAL VIOLATIONS OF | | | RECEPTACLE SPACING PER 210.52(A)(1) & | | | (2) IN THE EXERCISE,STUDY,ENTRY AND | | | BEDROOMS 2 & 3. | | | | | | 2} THE KITCHEN NEEDS RECEPTACLES ADDED | | | TO COMPLY WITH 210.52(C)(1). | | | | | | 3} THE NOTE REGARDING THE SMOKE | | | DETECTORS SHOULD BE CHANGED TO READ | | | "BED ROOM" CIRCUIT PER 210.12 2002 NEC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-05 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-05 |
Time |
16:15 |
Sent To |
B |
|
| Notes |
| 2003-12-05 00:00:00 | TO LS DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-12-08 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-10-31 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-06 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2003-10-06 00:00:00 | TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-14 |
Time |
07:52 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-11-14 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2003-11-14 00:00:00 | ALL RETURNS ARE DUCTED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-11-08 |
Time |
08:40 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-10-16 |
Time |
18:55 |
Sent To |
B |
|
| Notes |
| 2003-10-16 00:00:00 | PLAN DENIED | | | REFER TO SECTION 601.4 BALANCED RETURN | | | AIR.2001 FBC (M) GLITCH AS OF JULY 1 | | | 2003.RETURN IN MASTER BED ROOM TO SMALL. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-11-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-11-08 |
Time |
08:40 |
Rev Time |
33.00 |
| Received By |
jleech |
Date |
2003-11-08 |
Time |
08:40 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-10-31 |
Time |
08:57 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-10-08 |
Time |
19:48 |
Sent To |
E |
|
| Notes |
| 2003-10-08 00:00:00 | DENIED; | | | SEE RED LINED RISER DIAGRAM ADD VENTS | | | WERE REQUIRED. SIZE BUILDING DRAIN, 3" | | | OR 4"? | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-06 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|