Plan Review Details - Permit 03100205
Plan Review Stops For Permit 03100205
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-11-14 Cont ID  
Sent By csiegber Date 2003-12-05 Time 16:15 Rev Time 0.00
Received By lsmith Date 2003-11-14 Time 08:27 Sent To  
Notes
2003-11-14 00:00:00PLANS TO BE TAKEN TO PALM BEACH COUNTY
 AND IMPACT FEES PAID.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-20 Cont ID  
Sent By btrobaug Date 2003-11-13 Time 17:31 Rev Time 2.00
Received By lsmith Date 2003-10-20 Time 13:22 Sent To  
Notes
2003-10-20 00:00:00SEE NOTES FROM OTHER PLAN REVIEWERS.
 BUILDING OKAY.WILL SIGN OFF WHEN OTHER
 REVIEWS ARE PASSED. LS

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-11-13 Cont ID  
Sent By btrobaug Date 2003-11-13 Time 17:31 Rev Time 0.50
Received By btrobaug Date 2003-11-13 Time 16:59 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-10-16 Cont ID  
Sent By jleech Date 2003-10-08 Time 19:49 Rev Time 1.00
Received By btrobaug Date 2003-10-15 Time 14:04 Sent To M
Notes
2003-10-16 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE ARE SEVERAL VIOLATIONS OF
 RECEPTACLE SPACING PER 210.52(A)(1) &
 (2) IN THE EXERCISE,STUDY,ENTRY AND
 BEDROOMS 2 & 3.
  
 2} THE KITCHEN NEEDS RECEPTACLES ADDED
 TO COMPLY WITH 210.52(C)(1).
  
 3} THE NOTE REGARDING THE SMOKE
 DETECTORS SHOULD BE CHANGED TO READ
 "BED ROOM" CIRCUIT PER 210.12 2002 NEC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-05 Cont ID  
Sent By csiegber Date 2003-12-05 Time 16:15 Rev Time 0.00
Received By csiegber Date 2003-12-05 Time 16:15 Sent To B
Notes
2003-12-05 00:00:00TO LS DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-08 Cont ID  
Sent By lsmith Date 2003-12-08 Time 09:59 Rev Time 0.00
Received By lsmith Date 2003-10-31 Time 08:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-20 Cont ID  
Sent By mmclean Date 2003-10-06 Time 16:10 Rev Time 0.00
Received By csiegber Date 2003-10-03 Time 12:21 Sent To  
Notes
2003-10-06 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-11-14 Cont ID  
Sent By pkrauss Date 2003-11-14 Time 07:52 Rev Time 0.20
Received By pkrauss Date 2003-11-14 Time 07:49 Sent To  
Notes
2003-11-14 00:00:00ALL RETURNS ARE DUCTED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-10-16 Cont ID  
Sent By jleech Date 2003-11-08 Time 08:40 Rev Time 0.50
Received By hmoser Date 2003-10-16 Time 18:55 Sent To B
Notes
2003-10-16 00:00:00PLAN DENIED
 REFER TO SECTION 601.4 BALANCED RETURN
 AIR.2001 FBC (M) GLITCH AS OF JULY 1
 2003.RETURN IN MASTER BED ROOM TO SMALL.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-11-08 Cont ID  
Sent By jleech Date 2003-11-08 Time 08:40 Rev Time 33.00
Received By jleech Date 2003-11-08 Time 08:40 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-10-08 Cont ID  
Sent By lsmith Date 2003-10-31 Time 08:57 Rev Time 0.33
Received By jleech Date 2003-10-08 Time 19:48 Sent To E
Notes
2003-10-08 00:00:00DENIED;
 SEE RED LINED RISER DIAGRAM ADD VENTS
 WERE REQUIRED. SIZE BUILDING DRAIN, 3"
 OR 4"?
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-06 Cont ID  
Sent By mmclean Date 2003-10-06 Time 16:10 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***