Plan Review Details - Permit 03100200
Plan Review Stops For Permit 03100200
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-11-17 Cont ID  
Sent By lsmith Date 2003-11-17 Time 09:40 Rev Time 0.50
Received By lsmith Date 2003-11-17 Time 09:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-11-12 Cont ID  
Sent By csiegber Date 2003-11-17 Time 08:34 Rev Time 0.50
Received By lsmith Date 2003-11-12 Time 14:41 Sent To  
Notes
2003-11-12 00:00:00PRODUCT APPROVALS FOR CASEMENT WINDOWS
 SUBMITTED FOR PROVISO & FIXED GLASS
 WINDOW ADDED RIGHT ELEVATION. LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-11-07 Cont ID  
Sent By csiegber Date 2003-11-12 Time 14:13 Rev Time 1.00
Received By lsmith Date 2003-11-07 Time 09:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-07 Cont ID  
Sent By dpalmer Date 2003-11-07 Time 08:16 Rev Time 0.00
Received By lsmith Date 2003-10-23 Time 14:15 Sent To  
Notes
2003-10-23 00:00:00**************BUILDING REVIEW NOTES*****
  
 1. ENERGY EFFICIENCY CODE FORM MUST BE
 SIGNED BY OWNER/AGENT.
 2. AN EXTRA COPY OF THE FIRST PAGE OF
 THE ENERGY SHOULD BE SUBMITTED (WE ARE
 REQUIRED TO SEND IT TO THE STATE OF
 FLORIDA).
 3. FYI: THE PRODUCT APPROVAL FOR THE
 SLIDING GLASS DOOR (PGT SGD-2500) HAS
 EXPIRED.I WAS ABLE TO DOWNLOAD THE
 NEW ONE FROM THE INTERNET.FUTURE
 PERMITS WILL NEED THE NEW PRODUCT
 APPROVAL EXPIRING 5/29/2008.
 4. FYI: VALUE OF PERMIT IS BASED ON
 SBCCI EVALUATION:74.88 PER SQ. FT. OF
 LIVING SPACE & 41.60 FOR ALL OTHER
 SPACE UNDER ROOF.
 ITEMS 2,3 & 4 ARE FOR YOUR INFORMATION
 ONLY FOR FUTURE SUBMITTALS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH BUIDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-18 Cont ID  
Sent By dpalmer Date 2004-04-18 Time 13:31 Rev Time 0.25
Received By dpalmer Date 2004-04-18 Time 13:27 Sent To  
Notes
2004-04-18 00:00:00REDLINED EQUIPMENT GRND FROM PANEL TO
 SUB PANEL. 250.122

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-11-07 Cont ID  
Sent By csiegber Date 2004-04-14 Time 12:17 Rev Time 0.33
Received By dpalmer Date 2003-11-07 Time 08:15 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-10-20 Cont ID  
Sent By pkrauss Date 2003-11-07 Time 06:54 Rev Time 0.50
Received By dpalmer Date 2003-10-20 Time 13:08 Sent To M
Notes
2003-10-20 00:00:00*********** UNSAT *****************
  
 1)NOTE: PLEASE SEE FAC 61G1-16.004 AND
 PLACE ALL LICENSE INFORMATION ON TITLE
 BLOCKS. FS 471
 PLEASE SEE THAT THIS IS REQ'D FOR ALL
 TRADES WEATHER OR NOT THE COMMENT MAY
 OR MAY NOT COME FROM OTHER REVIEWERS.
  
 2)NOTE: PLEASE LIST THE REQ'D ARC FAULT
 PROTECTED CIRCUITS. PLEASE SEE THAT WE
 ARE NOW UNDER 2002 NEC AND ARC FAULT
 PROTECTTION HAS CHANGED FROM 99 NEC.
  
 PLEASE SUBMI THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 12:17 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 12:17 Sent To E
Notes
2004-04-14 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-17 Cont ID  
Sent By csiegber Date 2003-11-17 Time 08:34 Rev Time 0.00
Received By csiegber Date 2003-11-17 Time 08:34 Sent To B
Notes
2003-11-17 00:00:00TO LS DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-11-12 Cont ID  
Sent By csiegber Date 2003-11-12 Time 14:13 Rev Time 0.00
Received By csiegber Date 2003-11-12 Time 14:13 Sent To B
Notes
2003-11-12 00:00:00TO LS DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-30 Cont ID  
Sent By lsmith Date 2003-10-30 Time 16:28 Rev Time 0.00
Received By lsmith Date 2003-10-30 Time 16:28 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-23 Cont ID  
Sent By mmclean Date 2003-10-06 Time 16:09 Rev Time 0.00
Received By csiegber Date 2003-10-03 Time 12:19 Sent To  
Notes
2003-10-06 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-02-18 Cont ID  
Sent By pkrauss Date 2004-02-18 Time 07:07 Rev Time 0.30
Received By pkrauss Date 2004-02-18 Time 06:59 Sent To  
Notes
2004-02-18 00:00:00RE-STAMP

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-11-07 Cont ID  
Sent By pkrauss Date 2003-11-07 Time 06:54 Rev Time 0.25
Received By pkrauss Date 2003-11-07 Time 06:50 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-10-22 Cont ID  
Sent By lsmith Date 2003-10-30 Time 16:28 Rev Time 0.25
Received By pkrauss Date 2003-10-22 Time 07:12 Sent To B
Notes
2003-10-22 00:00:00DENIED:
 RETURN AIR REQUIRED FROM BEDROOMS 2,3 AS
 WELL AS THE LIBRARY.
  
 PLEASE NOTE, REVISION TO THE 2001
 FBC(M) 601.4, EFFECTIVE JUNE 30,2003:
  
 BALANCED AIR RETURN - RETURN/TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM ITS SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-10-14 Cont ID  
Sent By jleech Date 2003-10-14 Time 17:47 Rev Time 0.25
Received By jleech Date 2003-10-14 Time 17:47 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-06 Time 10:14 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***