| Plan Review Stops For Permit 03100126 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-12-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2003-12-15 |
Time |
15:45 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2003-12-15 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | PROVISO - SUBMIT STATE PRODUCT APPROVAL | | | OR SITE SPECIFIC BEFORE INSTALLATION | | | OF THERMATRU DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-08 |
Time |
08:55 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-10-22 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2003-10-27 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)THE PLAN SHOWS A SINGLE ASSEMBLY | | | FOR THE NEW A/C AREA, ENERGY CALCS | | | INDICATE UNDER ATTIC (10A).THE PLANS | | | SHOW INSULATION LESS THAN R VALUES ON | | | THE ENERGY CALCS. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 4.)ADDITIONAL FEES DUE (RADON), $1.56. | | | SEE ATTACHED BZ231384. | | | | | | 5.)THE LICENSE NUMBER FOR THE | | | ARCHITECT IS REQUIRED TO BE ON THE PLAN, | | | FAC61G1-16.004. | | | | | | 6.)ADDRESS THE MECHANICAL PROVISO ON | | | THE PLAN.MECHANICAL VENTILATION IS NOT | | | SHOWN ON THE PLAN.THE ELEVATIONS SHOW | | | THE WINDOW AS A SINGLE HUNG, THE FLOOR | | | PLAN SHOWS A CASEMENT, AND THE PRODUCT | | | APPROVAL IS FOR A FIXED WINDOW. | | | | | | 7.)IMPACT PROTECTION REQUIRED FBC | | | 1606.1.4.PROVIDE PRODUCT APPROVALS | | | AND AN ANCHOR SCHEDULE, SEE ATTACHED. | | | | | | 8.)SPECIFY ANCHORING, NOT "HURRICANE | | | STRAP".SEE DCA WEBSITE IN REGARDS TO | | | PRODUCT APPROVALS FOR STRUCTURAL | | | COMPONENTS. | | | | | | 9.)EFFECTIVE OCTOBER 1, STATEWIDE | | | PRODUCT APPROVALS ARE REQUIRED FOR | | | DOORS, WINDOWS, ROOFING PRODUCTS, | | | SHUTTERS, AND STRUCTURAL COMPONENTS, | | | FAC9B-72 DCA.SEE THE DCA WEBSITE FOR | | | MORE INFORMATION: | | | WWW.DCA.STATE.FL.US/FHCD/FBC/ | | | COMMITTEES/PRODUCT_APPROVAL/1_PRODUCT_ | | | APPROVAL.HTM |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-12-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-08 |
Time |
08:53 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-12-08 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2003-12-08 00:00:00 | REDLINED BATH GFI/ 20A/#12 210.11.C3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-10 |
Time |
16:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-10-10 |
Time |
17:02 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-11-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-21 |
Time |
16:53 |
Sent To |
M |
|
| Notes |
| 2003-11-21 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-10 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-10 |
Time |
16:40 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-10 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
16:12 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-03 |
Time |
07:06 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-12-03 |
Time |
07:06 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
16:53 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-10-15 |
Time |
09:44 |
Sent To |
B |
|
| Notes |
| 2003-10-15 00:00:00 | PROVISO: | | | 2001 FBC(M)402.3.1(REVISED JUNE 30,2003) | | | BATHROOMS SHALL HAVE A WINDOW WITH A | | | MINIMUM OF 3 SQ FT CLEAR OPENING OR HAVE | | | MECHANICAL VENTILATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-12-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2003-12-06 |
Time |
16:09 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
2003-12-06 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
| 2003-12-06 00:00:00 | ALL WORK SUBJECT TO FIELD INSPECTOR | | | APPROVAL. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-03 |
Time |
07:07 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-11 |
Time |
14:13 |
Sent To |
M |
|
| Notes |
| 2003-10-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMIN. CODE | | | | | | 1) SECTION 909.1 LAUNDRY SINK AND WASH | | | MACHINE SHALL CONNECT DOWNSTREAM OF THE | | | BATHROOM GROUP WET VENT. | | | 2) SECTION 802.4 WASH MACHINE REQUIRES | | | A STANDPIPE. | | | 3) SECTION 708.10 CLEANOUT FOR WASH | | | MACHINE SHALL BE 4' ABOVE THE FLOOR FOR | | | ACCESS. | | | 4) SECTION 104.2.1 SANITARY RISER DIA- | | | GRAM DOES NOT REFLECT THE FLOOR PLAN. | | | FLOOR PLAN SHOWS A TUB AND RISER SHOWS | | | A SHOWER. PLEASE CLAIRFY. | | | 5) SEE ATTACHED SHEET ABOUT DESIGN PRO- | | | FESSIONALS. 61G1-16.004(2) LICENSE NUM- | | | BER REQUIRED ON TITLE BLOCK. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|