Plan Review Details - Permit 03100126
Plan Review Stops For Permit 03100126
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-12-15 Cont ID  
Sent By shill Date 2003-12-15 Time 15:45 Rev Time 1.00
Received By shill Date 2003-12-15 Time 15:45 Sent To  
Notes
2003-12-15 00:00:00PROVISO - SUBMIT STATE PRODUCT APPROVAL
 OR SITE SPECIFIC BEFORE INSTALLATION
 OF THERMATRU DOOR

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-27 Cont ID  
Sent By dpalmer Date 2003-12-08 Time 08:55 Rev Time 2.00
Received By sthyng Date 2003-10-22 Time 07:50 Sent To  
Notes
2003-10-27 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEPARATE PERMITS REQUIRED.
  
 2.)THE PLAN SHOWS A SINGLE ASSEMBLY
 FOR THE NEW A/C AREA, ENERGY CALCS
 INDICATE UNDER ATTIC (10A).THE PLANS
 SHOW INSULATION LESS THAN R VALUES ON
 THE ENERGY CALCS.
  
 3.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 4.)ADDITIONAL FEES DUE (RADON), $1.56.
 SEE ATTACHED BZ231384.
  
 5.)THE LICENSE NUMBER FOR THE
 ARCHITECT IS REQUIRED TO BE ON THE PLAN,
 FAC61G1-16.004.
  
 6.)ADDRESS THE MECHANICAL PROVISO ON
 THE PLAN.MECHANICAL VENTILATION IS NOT
 SHOWN ON THE PLAN.THE ELEVATIONS SHOW
 THE WINDOW AS A SINGLE HUNG, THE FLOOR
 PLAN SHOWS A CASEMENT, AND THE PRODUCT
 APPROVAL IS FOR A FIXED WINDOW.
  
 7.)IMPACT PROTECTION REQUIRED FBC
 1606.1.4.PROVIDE PRODUCT APPROVALS
 AND AN ANCHOR SCHEDULE, SEE ATTACHED.
  
 8.)SPECIFY ANCHORING, NOT "HURRICANE
 STRAP".SEE DCA WEBSITE IN REGARDS TO
 PRODUCT APPROVALS FOR STRUCTURAL
 COMPONENTS.
  
 9.)EFFECTIVE OCTOBER 1, STATEWIDE
 PRODUCT APPROVALS ARE REQUIRED FOR
 DOORS, WINDOWS, ROOFING PRODUCTS,
 SHUTTERS, AND STRUCTURAL COMPONENTS,
 FAC9B-72 DCA.SEE THE DCA WEBSITE FOR
 MORE INFORMATION:
 WWW.DCA.STATE.FL.US/FHCD/FBC/
 COMMITTEES/PRODUCT_APPROVAL/1_PRODUCT_
 APPROVAL.HTM

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-12-08 Cont ID  
Sent By dpalmer Date 2003-12-08 Time 08:53 Rev Time 0.33
Received By dpalmer Date 2003-12-08 Time 08:55 Sent To B
Notes
2003-12-08 00:00:00REDLINED BATH GFI/ 20A/#12 210.11.C3

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-10 Time 16:41 Rev Time 0.50
Received By btrobaug Date 2003-10-10 Time 17:02 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 16:53 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 16:53 Sent To M
Notes
2003-11-21 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-10 Time 16:40 Rev Time 0.00
Received By csiegber Date 2003-10-10 Time 16:40 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-09 Cont ID  
Sent By mmclean Date 2003-10-10 Time 15:25 Rev Time 0.00
Received By csiegber Date 2003-10-09 Time 16:12 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-12-03 Cont ID  
Sent By pkrauss Date 2003-12-03 Time 07:06 Rev Time 0.33
Received By pkrauss Date 2003-12-03 Time 07:06 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-10-15 Cont ID  
Sent By csiegber Date 2003-11-21 Time 16:53 Rev Time 0.33
Received By pkrauss Date 2003-10-15 Time 09:44 Sent To B
Notes
2003-10-15 00:00:00PROVISO:
 2001 FBC(M)402.3.1(REVISED JUNE 30,2003)
 BATHROOMS SHALL HAVE A WINDOW WITH A
 MINIMUM OF 3 SQ FT CLEAR OPENING OR HAVE
 MECHANICAL VENTILATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-12-06 Cont ID  
Sent By pschmitz Date 2003-12-06 Time 16:09 Rev Time 1.50
Received By pschmitz Date 2003-12-06 Time 16:08 Sent To B
Notes
2003-12-06 00:00:00ALL WORK SUBJECT TO FIELD INSPECTOR
 APPROVAL. PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-10-11 Cont ID  
Sent By pkrauss Date 2003-12-03 Time 07:07 Rev Time 0.50
Received By kstevens Date 2003-10-11 Time 14:13 Sent To M
Notes
2003-10-11 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMIN. CODE
  
 1) SECTION 909.1 LAUNDRY SINK AND WASH
 MACHINE SHALL CONNECT DOWNSTREAM OF THE
 BATHROOM GROUP WET VENT.
 2) SECTION 802.4 WASH MACHINE REQUIRES
 A STANDPIPE.
 3) SECTION 708.10 CLEANOUT FOR WASH
 MACHINE SHALL BE 4' ABOVE THE FLOOR FOR
 ACCESS.
 4) SECTION 104.2.1 SANITARY RISER DIA-
 GRAM DOES NOT REFLECT THE FLOOR PLAN.
 FLOOR PLAN SHOWS A TUB AND RISER SHOWS
 A SHOWER. PLEASE CLAIRFY.
 5) SEE ATTACHED SHEET ABOUT DESIGN PRO-
 FESSIONALS. 61G1-16.004(2) LICENSE NUM-
 BER REQUIRED ON TITLE BLOCK.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-09 Time 16:12 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***